24
Galleon Pro 6KVA/10KVA
Split phase Online UPS
Galleon 2 phase in / 2 phase out 6KVA and 10KVA UPSs provide 208/120 output voltage without the need of adding transformers. Designed in small footprints, this most powerful online series integrates true double conversion design, DSP technology, and active input power factor correction design to ensure better output voltage conditions, power quality and power performance at all times. Besides, easy-configurable program via LCD panel enhances the flexibility to meet ever-increasing power demand of IT and networked environment.


Main Features
- True double-conversion
- DSP technology guarantees high performance
- Output Power Factor 0.8
- Wide input voltage range (60-150 VAC)
- Active input power factor correction 0.99
- 50Hz/60Hz frequency converter mode
- Eco mode operation for energy saving (ECO)
- Emergency power off function (EPO)
- Generator compatible
- Charger capacity expansion to 8A for long-run models
- SNMP/USB/RS-232 communications
- 3-stage extendable charging design for optimized battery performance
- Maintenance bypass available
- Adjustable battery numbers
MODEL | Galleon 2/2 6K(L) | Galleon 2/2 6KR(L) | Galleon 2/2 10K(L) | Galleon 2/2 10KR(L) | |
CAPACITY | 6000 VA / 4800 W | 6000 VA / 4800 W | 10000 VA / 8000 W | 10000 VA / 8000 W | |
PHASE | 2 phase in / 2 phase out | 2 phase in / 2 phase out | 2 phase in / 2 phase out | 2 phase in / 2 phase out | |
INPUT | |||||
Voltage Range | 60-150 VAC (Phase-N) @ 50% load; 80-140 VAC (Phase-N) @ 100% load | 60-150 VAC (Phase-N) @ 50% load; 80-140 VAC (Phase-N) @ 100% load | 60-150 VAC (Phase-N) @ 50% load; 80-140 VAC (Phase-N) @ 100% load | 60-150 VAC (Phase-N) @ 50% load; 80-140 VAC (Phase-N) @ 100% load | |
Nominal Voltage | 100/110/115/120/127 VAC (L-N) | 100/110/115/120/127 VAC (L-N) | 100/110/115/120/127 VAC (L-N) | 100/110/115/120/127 VAC (L-N) | |
Frequency Range | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz | |
Power Factor | ≧ 0.99 @ 100% load | ≧ 0.99 @ 100% load | ≧ 0.99 @ 100% load | ≧ 0.99 @ 100% load | |
Phase Angle | 0°/120°/180°/240° | 0°/120°/180°/240° | 0°/120°/180°/240° | 0°/120°/180°/240° | |
OUTPUT | |||||
Output Voltage | 100/110/115/120/127 VAC (L-N) | 100/110/115/120/127 VAC (L-N) | 100/110/115/120/127 VAC (L-N) | 100/110/115/120/127 VAC (L-N) | |
AC Voltage Regulation (Batt. Mode) | ± 1% | ± 1% | ± 1% | ± 1% | |
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |
Transfer Time | AC Mode to Battery Mode | Zero | Zero | Zero | Zero |
Transfer Time | Inverter to Bypass | Zero | Zero | Zero | Zero |
Transfer Time | Inverter to ECO | < 10ms | < 10ms | < 10ms | < 10ms |
Waveform (Batt. Mode) | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | |
Current Crest Ratio | 3:1 (max.) | 3:1 (max.) | 3:1 (max.) | 3:1 (max.) | |
Harmonic Distortion | ≦ 2% THD (Linear Load), ≦ 5% THD (Non-linear Load) | ≦ 2% THD (Linear Load), ≦ 5% THD (Non-linear Load) | ≦ 2% THD (Linear Load), ≦ 5% THD (Non-linear Load) | ≦ 2% THD (Linear Load), ≦ 5% THD (Non-linear Load) | |
Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz | |
Phase Angle | 0°/120°/180°/240° | 0°/120°/180°/240° | 0°/120°/180°/240° | 0°/120°/180°/240° | |
EFFICIENCY | |||||
Battery Mode | 87.0% | 87.0% | 88.0% | 88.0% | |
ECO Mode | 96.0% | 96.0% | 96.0% | 96.0% | |
AC Mode | 90.5% | 90.5% | 91.0% | 91.0% | |
BATTERY | |||||
Long-run Model | Battery Type | Depending on applications | Depending on applications | Depending on applications | Depending on applications |
Long-run Model | Charging Current (max.) | 8.0 A | 8.0 A | 8.0 A | 8.0 A |
Long-run Model | Float Charging Voltage | 136.5 VDC | 136.5 VDC | 136.5 VDC | 136.5 VDC |
Long-run Model | Numbers | Depending on applications | Depending on applications | Depending on applications | Depending on applications |
Standard Model | Battery Type | 12 V / 7 AH | 12 V / 7 AH | 12 V / 9 AH | 12 V / 9 AH |
Standard Model | Charging Current (max.) | 2.0 A | 2.0 A | 2.0 A | 2.0 A |
Standard Model | Float Charging Voltage | 136.5 VDC | 136.5 VDC | 136.5 VDC | 136.5 VDC |
Standard Model | Numbers | 10 pcs x 2 strings | 10 pcs x 2 strings | 10 pcs x 2 strings | 10 pcs x 2 strings |
Standard Model | Typical Recharge Time | 5 hours recover to 90% capacity | 5 hours recover to 90% capacity | 7 hours recover to 90% capacity | 7 hours recover to 90% capacity |
INDICATORS | |||||
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | |
ALARM | |||||
Battery Mode | Sounding every 4 seconds | Sounding every 4 seconds | Sounding every 4 seconds | Sounding every 4 seconds | |
Low Battery | Sounding every second | Sounding every second | Sounding every second | Sounding every second | |
Overload | Sounding twice every second | Sounding twice every second | Sounding twice every second | Sounding twice every second | |
Fault | Continuously sounding | Continuously sounding | Continuously sounding | Continuously sounding | |
ENVIRONMENT | |||||
Operating Humidity | 0~95% RH @ 0- 40°C (non-condensing) | 0~95% RH @ 0- 40°C (non-condensing) | 0~95% RH @ 0- 40°C (non-condensing) | 0~95% RH @ 0- 40°C (non-condensing) | |
Noise Level | Less than 60dB @ 1 Meter | Less than 60dB @ 1 Meter | Less than 60dB @ 1 Meter | Less than 60dB @ 1 Meter | |
PHYSICAL | |||||
Standard Model | Dimension, D X W X H (mm) | 592 x 250 x 576 | UPS unit:668 x 438 x 133(3U); Battery pack: 580 x 438 x 133(3U) | 592 × 250 × 826 | UPS unit:668 x 438 x 266(6U); Battery pack: 580 x 438 x 133(3U) |
Standard Model | Net Weight (kgs) | 83 | UPS unit: 22; Battery pack: 63 | 100 | UPS unit: 45; Battery pack: 63 |
Long-run Model | Dimension, D X W X H (mm) | 592 x 250 x 576 | 668 x 438 x 133(3U) | 592 x 250 x 576 | 668 x 438 x 266(6U) |
Long-run Model | Net Weight (kgs) | 28 | 22 | 38 | 45 |
MANAGEMENT | |||||
Optional SNMP | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | |
Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
General
CAPACITY
Galleon 2/2 6K(L) | 6000 VA / 4800 W |
---|---|
Galleon 2/2 6KR(L) | 6000 VA / 4800 W |
Galleon 2/2 10K(L) | 10000 VA / 8000 W |
Galleon 2/2 10KR(L) | 10000 VA / 8000 W |
PHASE
Galleon 2/2 6K(L) | 2 phase in / 2 phase out |
---|---|
Galleon 2/2 6KR(L) | 2 phase in / 2 phase out |
Galleon 2/2 10K(L) | 2 phase in / 2 phase out |
Galleon 2/2 10KR(L) | 2 phase in / 2 phase out |
INPUT
Voltage Range
Galleon 2/2 6K(L) | 60-150 VAC (Phase-N) @ 50% load; 80-140 VAC (Phase-N) @ 100% load |
---|---|
Galleon 2/2 6KR(L) | 60-150 VAC (Phase-N) @ 50% load; 80-140 VAC (Phase-N) @ 100% load |
Galleon 2/2 10K(L) | 60-150 VAC (Phase-N) @ 50% load; 80-140 VAC (Phase-N) @ 100% load |
Galleon 2/2 10KR(L) | 60-150 VAC (Phase-N) @ 50% load; 80-140 VAC (Phase-N) @ 100% load |
Nominal Voltage
Galleon 2/2 6K(L) | 100/110/115/120/127 VAC (L-N) |
---|---|
Galleon 2/2 6KR(L) | 100/110/115/120/127 VAC (L-N) |
Galleon 2/2 10K(L) | 100/110/115/120/127 VAC (L-N) |
Galleon 2/2 10KR(L) | 100/110/115/120/127 VAC (L-N) |
Frequency Range
Galleon 2/2 6K(L) | 46~54 Hz or 56~64 Hz |
---|---|
Galleon 2/2 6KR(L) | 46~54 Hz or 56~64 Hz |
Galleon 2/2 10K(L) | 46~54 Hz or 56~64 Hz |
Galleon 2/2 10KR(L) | 46~54 Hz or 56~64 Hz |
Power Factor
Galleon 2/2 6K(L) | ≧ 0.99 @ 100% load |
---|---|
Galleon 2/2 6KR(L) | ≧ 0.99 @ 100% load |
Galleon 2/2 10K(L) | ≧ 0.99 @ 100% load |
Galleon 2/2 10KR(L) | ≧ 0.99 @ 100% load |
Phase Angle
Galleon 2/2 6K(L) | 0°/120°/180°/240° |
---|---|
Galleon 2/2 6KR(L) | 0°/120°/180°/240° |
Galleon 2/2 10K(L) | 0°/120°/180°/240° |
Galleon 2/2 10KR(L) | 0°/120°/180°/240° |
OUTPUT
Output Voltage
Galleon 2/2 6K(L) | 100/110/115/120/127 VAC (L-N) |
---|---|
Galleon 2/2 6KR(L) | 100/110/115/120/127 VAC (L-N) |
Galleon 2/2 10K(L) | 100/110/115/120/127 VAC (L-N) |
Galleon 2/2 10KR(L) | 100/110/115/120/127 VAC (L-N) |
AC Voltage Regulation (Batt. Mode)
Galleon 2/2 6K(L) | ± 1% |
---|---|
Galleon 2/2 6KR(L) | ± 1% |
Galleon 2/2 10K(L) | ± 1% |
Galleon 2/2 10KR(L) | ± 1% |
Frequency Range (Batt. Mode)
Galleon 2/2 6K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
---|---|
Galleon 2/2 6KR(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon 2/2 10K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon 2/2 10KR(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Transfer Time AC Mode to Battery Mode
Galleon 2/2 6K(L) | Zero |
---|---|
Galleon 2/2 6KR(L) | Zero |
Galleon 2/2 10K(L) | Zero |
Galleon 2/2 10KR(L) | Zero |
Transfer Time Inverter to Bypass
Galleon 2/2 6K(L) | Zero |
---|---|
Galleon 2/2 6KR(L) | Zero |
Galleon 2/2 10K(L) | Zero |
Galleon 2/2 10KR(L) | Zero |
Transfer Time Inverter to ECO
Galleon 2/2 6K(L) | < 10ms |
---|---|
Galleon 2/2 6KR(L) | < 10ms |
Galleon 2/2 10K(L) | < 10ms |
Galleon 2/2 10KR(L) | < 10ms |
Waveform (Batt. Mode)
Galleon 2/2 6K(L) | Pure Sine Wave |
---|---|
Galleon 2/2 6KR(L) | Pure Sine Wave |
Galleon 2/2 10K(L) | Pure Sine Wave |
Galleon 2/2 10KR(L) | Pure Sine Wave |
Current Crest Ratio
Galleon 2/2 6K(L) | 3:1 (max.) |
---|---|
Galleon 2/2 6KR(L) | 3:1 (max.) |
Galleon 2/2 10K(L) | 3:1 (max.) |
Galleon 2/2 10KR(L) | 3:1 (max.) |
Harmonic Distortion
Galleon 2/2 6K(L) | ≦ 2% THD (Linear Load), ≦ 5% THD (Non-linear Load) |
---|---|
Galleon 2/2 6KR(L) | ≦ 2% THD (Linear Load), ≦ 5% THD (Non-linear Load) |
Galleon 2/2 10K(L) | ≦ 2% THD (Linear Load), ≦ 5% THD (Non-linear Load) |
Galleon 2/2 10KR(L) | ≦ 2% THD (Linear Load), ≦ 5% THD (Non-linear Load) |
Frequency Range (Synchronized Range)
Galleon 2/2 6K(L) | 46~54 Hz or 56~64 Hz |
---|---|
Galleon 2/2 6KR(L) | 46~54 Hz or 56~64 Hz |
Galleon 2/2 10K(L) | 46~54 Hz or 56~64 Hz |
Galleon 2/2 10KR(L) | 46~54 Hz or 56~64 Hz |
Phase Angle
Galleon 2/2 6K(L) | 0°/120°/180°/240° |
---|---|
Galleon 2/2 6KR(L) | 0°/120°/180°/240° |
Galleon 2/2 10K(L) | 0°/120°/180°/240° |
Galleon 2/2 10KR(L) | 0°/120°/180°/240° |
EFFICIENCY
Battery Mode
Galleon 2/2 6K(L) | 87.0% |
---|---|
Galleon 2/2 6KR(L) | 87.0% |
Galleon 2/2 10K(L) | 88.0% |
Galleon 2/2 10KR(L) | 88.0% |
ECO Mode
Galleon 2/2 6K(L) | 96.0% |
---|---|
Galleon 2/2 6KR(L) | 96.0% |
Galleon 2/2 10K(L) | 96.0% |
Galleon 2/2 10KR(L) | 96.0% |
AC Mode
Galleon 2/2 6K(L) | 90.5% |
---|---|
Galleon 2/2 6KR(L) | 90.5% |
Galleon 2/2 10K(L) | 91.0% |
Galleon 2/2 10KR(L) | 91.0% |
BATTERY
Long-run Model Battery Type
Galleon 2/2 6K(L) | Depending on applications |
---|---|
Galleon 2/2 6KR(L) | Depending on applications |
Galleon 2/2 10K(L) | Depending on applications |
Galleon 2/2 10KR(L) | Depending on applications |
Long-run Model Charging Current (max.)
Galleon 2/2 6K(L) | 8.0 A |
---|---|
Galleon 2/2 6KR(L) | 8.0 A |
Galleon 2/2 10K(L) | 8.0 A |
Galleon 2/2 10KR(L) | 8.0 A |
Long-run Model Float Charging Voltage
Galleon 2/2 6K(L) | 136.5 VDC |
---|---|
Galleon 2/2 6KR(L) | 136.5 VDC |
Galleon 2/2 10K(L) | 136.5 VDC |
Galleon 2/2 10KR(L) | 136.5 VDC |
Long-run Model Numbers
Galleon 2/2 6K(L) | Depending on applications |
---|---|
Galleon 2/2 6KR(L) | Depending on applications |
Galleon 2/2 10K(L) | Depending on applications |
Galleon 2/2 10KR(L) | Depending on applications |
Standard Model Battery Type
Galleon 2/2 6K(L) | 12 V / 7 AH |
---|---|
Galleon 2/2 6KR(L) | 12 V / 7 AH |
Galleon 2/2 10K(L) | 12 V / 9 AH |
Galleon 2/2 10KR(L) | 12 V / 9 AH |
Standard Model Charging Current (max.)
Galleon 2/2 6K(L) | 2.0 A |
---|---|
Galleon 2/2 6KR(L) | 2.0 A |
Galleon 2/2 10K(L) | 2.0 A |
Galleon 2/2 10KR(L) | 2.0 A |
Standard Model Float Charging Voltage
Galleon 2/2 6K(L) | 136.5 VDC |
---|---|
Galleon 2/2 6KR(L) | 136.5 VDC |
Galleon 2/2 10K(L) | 136.5 VDC |
Galleon 2/2 10KR(L) | 136.5 VDC |
Standard Model Numbers
Galleon 2/2 6K(L) | 10 pcs x 2 strings |
---|---|
Galleon 2/2 6KR(L) | 10 pcs x 2 strings |
Galleon 2/2 10K(L) | 10 pcs x 2 strings |
Galleon 2/2 10KR(L) | 10 pcs x 2 strings |
Standard Model Typical Recharge Time
Galleon 2/2 6K(L) | 5 hours recover to 90% capacity |
---|---|
Galleon 2/2 6KR(L) | 5 hours recover to 90% capacity |
Galleon 2/2 10K(L) | 7 hours recover to 90% capacity |
Galleon 2/2 10KR(L) | 7 hours recover to 90% capacity |
INDICATORS
LCD Panel
Galleon 2/2 6K(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
---|---|
Galleon 2/2 6KR(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon 2/2 10K(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon 2/2 10KR(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
ALARM
Battery Mode
Galleon 2/2 6K(L) | Sounding every 4 seconds |
---|---|
Galleon 2/2 6KR(L) | Sounding every 4 seconds |
Galleon 2/2 10K(L) | Sounding every 4 seconds |
Galleon 2/2 10KR(L) | Sounding every 4 seconds |
Low Battery
Galleon 2/2 6K(L) | Sounding every second |
---|---|
Galleon 2/2 6KR(L) | Sounding every second |
Galleon 2/2 10K(L) | Sounding every second |
Galleon 2/2 10KR(L) | Sounding every second |
Overload
Galleon 2/2 6K(L) | Sounding twice every second |
---|---|
Galleon 2/2 6KR(L) | Sounding twice every second |
Galleon 2/2 10K(L) | Sounding twice every second |
Galleon 2/2 10KR(L) | Sounding twice every second |
Fault
Galleon 2/2 6K(L) | Continuously sounding |
---|---|
Galleon 2/2 6KR(L) | Continuously sounding |
Galleon 2/2 10K(L) | Continuously sounding |
Galleon 2/2 10KR(L) | Continuously sounding |
ENVIRONMENT
Operating Humidity
Galleon 2/2 6K(L) | 0~95% RH @ 0- 40°C (non-condensing) |
---|---|
Galleon 2/2 6KR(L) | 0~95% RH @ 0- 40°C (non-condensing) |
Galleon 2/2 10K(L) | 0~95% RH @ 0- 40°C (non-condensing) |
Galleon 2/2 10KR(L) | 0~95% RH @ 0- 40°C (non-condensing) |
Noise Level
Galleon 2/2 6K(L) | Less than 60dB @ 1 Meter |
---|---|
Galleon 2/2 6KR(L) | Less than 60dB @ 1 Meter |
Galleon 2/2 10K(L) | Less than 60dB @ 1 Meter |
Galleon 2/2 10KR(L) | Less than 60dB @ 1 Meter |
PHYSICAL
Standard Model Dimension, D X W X H (mm)
Galleon 2/2 6K(L) | 592 x 250 x 576 |
---|---|
Galleon 2/2 6KR(L) | UPS unit:668 x 438 x 133(3U); Battery pack: 580 x 438 x 133(3U) |
Galleon 2/2 10K(L) | 592 × 250 × 826 |
Galleon 2/2 10KR(L) | UPS unit:668 x 438 x 266(6U); Battery pack: 580 x 438 x 133(3U) |
Standard Model Net Weight (kgs)
Galleon 2/2 6K(L) | 83 |
---|---|
Galleon 2/2 6KR(L) | UPS unit: 22; Battery pack: 63 |
Galleon 2/2 10K(L) | 100 |
Galleon 2/2 10KR(L) | UPS unit: 45; Battery pack: 63 |
Long-run Model Dimension, D X W X H (mm)
Galleon 2/2 6K(L) | 592 x 250 x 576 |
---|---|
Galleon 2/2 6KR(L) | 668 x 438 x 133(3U) |
Galleon 2/2 10K(L) | 592 x 250 x 576 |
Galleon 2/2 10KR(L) | 668 x 438 x 266(6U) |
Long-run Model Net Weight (kgs)
Galleon 2/2 6K(L) | 28 |
---|---|
Galleon 2/2 6KR(L) | 22 |
Galleon 2/2 10K(L) | 38 |
Galleon 2/2 10KR(L) | 45 |
MANAGEMENT
Optional SNMP
Galleon 2/2 6K(L) | Power management from SNMP manager and web browser |
---|---|
Galleon 2/2 6KR(L) | Power management from SNMP manager and web browser |
Galleon 2/2 10K(L) | Power management from SNMP manager and web browser |
Galleon 2/2 10KR(L) | Power management from SNMP manager and web browser |
Smart RS-232 / USB
Galleon 2/2 6K(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
---|---|
Galleon 2/2 6KR(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon 2/2 10K(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon 2/2 10KR(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
![]() |
Brochure | Galleon 2P/2P 6K-10K |
![]() |
Manual | Galleon 2P/2P 6K-10K |
Single phase - Online UPS Galleon Pro 6KVA/10KVA Split phase Online UPS
Related Products
We have received your membership application and will reply as soon as within 24 hours, before that, please browse our website, thank you.