Galleon Pro 6KVA/10KVA
Split phase Online UPS
Galleon 2 phase in / 2 phase out 6KVA and 10KVA UPSs provide 208/120 output voltage without the need of adding transformers. Designed in small footprints, this most powerful online series integrates true double conversion design, DSP technology, and active input power factor correction design to ensure better output voltage conditions, power quality and power performance at all times. Besides, easy-configurable program via LCD panel enhances the flexibility to meet ever-increasing power demand of IT and networked environment.
Main Features
  • True double-conversion
  • DSP technology guarantees high performance
  • Output Power Factor 0.8
  • Wide input voltage range (60-150 VAC)
  • Active input power factor correction 0.99
  • 50Hz/60Hz frequency converter mode
  • Eco mode operation for energy saving (ECO)
  • Emergency power off function (EPO)
  • Generator compatible
  • Charger capacity expansion to 8A for long-run models
  • SNMP/USB/RS-232 communications
  • 3-stage extendable charging design for optimized battery performance
  • Maintenance bypass available
  • Adjustable battery numbers
General
CAPACITY
Galleon 2/2 6K(L)6000 VA / 4800 W
Galleon 2/2 6KR(L)6000 VA / 4800 W
Galleon 2/2 10K(L)10000 VA / 8000 W
Galleon 2/2 10KR(L)10000 VA / 8000 W
PHASE
Galleon 2/2 6K(L)2 phase in / 2 phase out
Galleon 2/2 6KR(L)2 phase in / 2 phase out
Galleon 2/2 10K(L)2 phase in / 2 phase out
Galleon 2/2 10KR(L)2 phase in / 2 phase out
INPUT
Voltage Range
Galleon 2/2 6K(L)60-150 VAC (Phase-N) @ 50% load; 80-140 VAC (Phase-N) @ 100% load
Galleon 2/2 6KR(L)60-150 VAC (Phase-N) @ 50% load; 80-140 VAC (Phase-N) @ 100% load
Galleon 2/2 10K(L)60-150 VAC (Phase-N) @ 50% load; 80-140 VAC (Phase-N) @ 100% load
Galleon 2/2 10KR(L)60-150 VAC (Phase-N) @ 50% load; 80-140 VAC (Phase-N) @ 100% load
Nominal Voltage
Galleon 2/2 6K(L)100/110/115/120/127 VAC (L-N)
Galleon 2/2 6KR(L)100/110/115/120/127 VAC (L-N)
Galleon 2/2 10K(L)100/110/115/120/127 VAC (L-N)
Galleon 2/2 10KR(L)100/110/115/120/127 VAC (L-N)
Frequency Range
Galleon 2/2 6K(L)46~54 Hz or 56~64 Hz
Galleon 2/2 6KR(L)46~54 Hz or 56~64 Hz
Galleon 2/2 10K(L)46~54 Hz or 56~64 Hz
Galleon 2/2 10KR(L)46~54 Hz or 56~64 Hz
Power Factor
Galleon 2/2 6K(L)≧ 0.99 @ 100% load
Galleon 2/2 6KR(L)≧ 0.99 @ 100% load
Galleon 2/2 10K(L)≧ 0.99 @ 100% load
Galleon 2/2 10KR(L)≧ 0.99 @ 100% load
Phase Angle
Galleon 2/2 6K(L)0°/120°/180°/240°
Galleon 2/2 6KR(L)0°/120°/180°/240°
Galleon 2/2 10K(L)0°/120°/180°/240°
Galleon 2/2 10KR(L)0°/120°/180°/240°
OUTPUT
Output Voltage
Galleon 2/2 6K(L)100/110/115/120/127 VAC (L-N)
Galleon 2/2 6KR(L)100/110/115/120/127 VAC (L-N)
Galleon 2/2 10K(L)100/110/115/120/127 VAC (L-N)
Galleon 2/2 10KR(L)100/110/115/120/127 VAC (L-N)
AC Voltage Regulation (Batt. Mode)
Galleon 2/2 6K(L)± 1%
Galleon 2/2 6KR(L)± 1%
Galleon 2/2 10K(L)± 1%
Galleon 2/2 10KR(L)± 1%
Frequency Range (Batt. Mode)
Galleon 2/2 6K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon 2/2 6KR(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon 2/2 10K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon 2/2 10KR(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Transfer Time AC Mode to Battery Mode
Galleon 2/2 6K(L)Zero
Galleon 2/2 6KR(L)Zero
Galleon 2/2 10K(L)Zero
Galleon 2/2 10KR(L)Zero
Transfer Time Inverter to Bypass
Galleon 2/2 6K(L)Zero
Galleon 2/2 6KR(L)Zero
Galleon 2/2 10K(L)Zero
Galleon 2/2 10KR(L)Zero
Transfer Time Inverter to ECO
Galleon 2/2 6K(L)< 10ms
Galleon 2/2 6KR(L)< 10ms
Galleon 2/2 10K(L)< 10ms
Galleon 2/2 10KR(L)< 10ms
Waveform (Batt. Mode)
Galleon 2/2 6K(L)Pure Sine Wave
Galleon 2/2 6KR(L)Pure Sine Wave
Galleon 2/2 10K(L)Pure Sine Wave
Galleon 2/2 10KR(L)Pure Sine Wave
Current Crest Ratio
Galleon 2/2 6K(L)3:1 (max.)
Galleon 2/2 6KR(L)3:1 (max.)
Galleon 2/2 10K(L)3:1 (max.)
Galleon 2/2 10KR(L)3:1 (max.)
Harmonic Distortion
Galleon 2/2 6K(L)≦ 2% THD (Linear Load), ≦ 5% THD (Non-linear Load)
Galleon 2/2 6KR(L)≦ 2% THD (Linear Load), ≦ 5% THD (Non-linear Load)
Galleon 2/2 10K(L)≦ 2% THD (Linear Load), ≦ 5% THD (Non-linear Load)
Galleon 2/2 10KR(L)≦ 2% THD (Linear Load), ≦ 5% THD (Non-linear Load)
Frequency Range (Synchronized Range)
Galleon 2/2 6K(L)46~54 Hz or 56~64 Hz
Galleon 2/2 6KR(L)46~54 Hz or 56~64 Hz
Galleon 2/2 10K(L)46~54 Hz or 56~64 Hz
Galleon 2/2 10KR(L)46~54 Hz or 56~64 Hz
Phase Angle
Galleon 2/2 6K(L)0°/120°/180°/240°
Galleon 2/2 6KR(L)0°/120°/180°/240°
Galleon 2/2 10K(L)0°/120°/180°/240°
Galleon 2/2 10KR(L)0°/120°/180°/240°
EFFICIENCY
Battery Mode
Galleon 2/2 6K(L)87.0%
Galleon 2/2 6KR(L)87.0%
Galleon 2/2 10K(L)88.0%
Galleon 2/2 10KR(L)88.0%
ECO Mode
Galleon 2/2 6K(L)96.0%
Galleon 2/2 6KR(L)96.0%
Galleon 2/2 10K(L)96.0%
Galleon 2/2 10KR(L)96.0%
AC Mode
Galleon 2/2 6K(L)90.5%
Galleon 2/2 6KR(L)90.5%
Galleon 2/2 10K(L)91.0%
Galleon 2/2 10KR(L)91.0%
BATTERY
Long-run Model Battery Type
Galleon 2/2 6K(L)Depending on applications
Galleon 2/2 6KR(L)Depending on applications
Galleon 2/2 10K(L)Depending on applications
Galleon 2/2 10KR(L)Depending on applications
Long-run Model Charging Current (max.)
Galleon 2/2 6K(L)8.0 A
Galleon 2/2 6KR(L)8.0 A
Galleon 2/2 10K(L)8.0 A
Galleon 2/2 10KR(L)8.0 A
Long-run Model Float Charging Voltage
Galleon 2/2 6K(L)136.5 VDC
Galleon 2/2 6KR(L)136.5 VDC
Galleon 2/2 10K(L)136.5 VDC
Galleon 2/2 10KR(L)136.5 VDC
Long-run Model Numbers
Galleon 2/2 6K(L)Depending on applications
Galleon 2/2 6KR(L)Depending on applications
Galleon 2/2 10K(L)Depending on applications
Galleon 2/2 10KR(L)Depending on applications
Standard Model Battery Type
Galleon 2/2 6K(L)12 V / 7 AH
Galleon 2/2 6KR(L)12 V / 7 AH
Galleon 2/2 10K(L)12 V / 9 AH
Galleon 2/2 10KR(L)12 V / 9 AH
Standard Model Charging Current (max.)
Galleon 2/2 6K(L)2.0 A
Galleon 2/2 6KR(L)2.0 A
Galleon 2/2 10K(L)2.0 A
Galleon 2/2 10KR(L)2.0 A
Standard Model Float Charging Voltage
Galleon 2/2 6K(L)136.5 VDC
Galleon 2/2 6KR(L)136.5 VDC
Galleon 2/2 10K(L)136.5 VDC
Galleon 2/2 10KR(L)136.5 VDC
Standard Model Numbers
Galleon 2/2 6K(L)10 pcs x 2 strings
Galleon 2/2 6KR(L)10 pcs x 2 strings
Galleon 2/2 10K(L)10 pcs x 2 strings
Galleon 2/2 10KR(L)10 pcs x 2 strings
Standard Model Typical Recharge Time
Galleon 2/2 6K(L)5 hours recover to 90% capacity
Galleon 2/2 6KR(L)5 hours recover to 90% capacity
Galleon 2/2 10K(L)7 hours recover to 90% capacity
Galleon 2/2 10KR(L)7 hours recover to 90% capacity
INDICATORS
LCD Panel
Galleon 2/2 6K(L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Galleon 2/2 6KR(L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Galleon 2/2 10K(L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Galleon 2/2 10KR(L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode
Galleon 2/2 6K(L)Sounding every 4 seconds
Galleon 2/2 6KR(L)Sounding every 4 seconds
Galleon 2/2 10K(L)Sounding every 4 seconds
Galleon 2/2 10KR(L)Sounding every 4 seconds
Low Battery
Galleon 2/2 6K(L)Sounding every second
Galleon 2/2 6KR(L)Sounding every second
Galleon 2/2 10K(L)Sounding every second
Galleon 2/2 10KR(L)Sounding every second
Overload
Galleon 2/2 6K(L)Sounding twice every second
Galleon 2/2 6KR(L)Sounding twice every second
Galleon 2/2 10K(L)Sounding twice every second
Galleon 2/2 10KR(L)Sounding twice every second
Fault
Galleon 2/2 6K(L)Continuously sounding
Galleon 2/2 6KR(L)Continuously sounding
Galleon 2/2 10K(L)Continuously sounding
Galleon 2/2 10KR(L)Continuously sounding
ENVIRONMENT
Operating Humidity
Galleon 2/2 6K(L)0~95% RH @ 0- 40°C (non-condensing)
Galleon 2/2 6KR(L)0~95% RH @ 0- 40°C (non-condensing)
Galleon 2/2 10K(L)0~95% RH @ 0- 40°C (non-condensing)
Galleon 2/2 10KR(L)0~95% RH @ 0- 40°C (non-condensing)
Noise Level
Galleon 2/2 6K(L)Less than 60dB @ 1 Meter
Galleon 2/2 6KR(L)Less than 60dB @ 1 Meter
Galleon 2/2 10K(L)Less than 60dB @ 1 Meter
Galleon 2/2 10KR(L)Less than 60dB @ 1 Meter
PHYSICAL
Standard Model Dimension, D X W X H (mm)
Galleon 2/2 6K(L)592 x 250 x 576
Galleon 2/2 6KR(L)UPS unit:668 x 438 x 133(3U); Battery pack: 580 x 438 x 133(3U)
Galleon 2/2 10K(L)592 × 250 × 826
Galleon 2/2 10KR(L)UPS unit:668 x 438 x 266(6U); Battery pack: 580 x 438 x 133(3U)
Standard Model Net Weight (kgs)
Galleon 2/2 6K(L)83
Galleon 2/2 6KR(L)UPS unit: 22; Battery pack: 63
Galleon 2/2 10K(L)100
Galleon 2/2 10KR(L)UPS unit: 45; Battery pack: 63
Long-run Model Dimension, D X W X H (mm)
Galleon 2/2 6K(L)592 x 250 x 576
Galleon 2/2 6KR(L)668 x 438 x 133(3U)
Galleon 2/2 10K(L)592 x 250 x 576
Galleon 2/2 10KR(L)668 x 438 x 266(6U)
Long-run Model Net Weight (kgs)
Galleon 2/2 6K(L)28
Galleon 2/2 6KR(L)22
Galleon 2/2 10K(L)38
Galleon 2/2 10KR(L)45
MANAGEMENT
Optional SNMP
Galleon 2/2 6K(L)Power management from SNMP manager and web browser
Galleon 2/2 6KR(L)Power management from SNMP manager and web browser
Galleon 2/2 10K(L)Power management from SNMP manager and web browser
Galleon 2/2 10KR(L)Power management from SNMP manager and web browser
Smart RS-232 / USB
Galleon 2/2 6K(L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon 2/2 6KR(L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon 2/2 10K(L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon 2/2 10KR(L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Brochure Galleon 2P/2P 6K-10K
Manual Galleon 2P/2P 6K-10K
Related Products