Pioneer
Variable Frequency Drive
Pioneer provides dependable and accurate control for asynchronous AC induction motors. It incorporates space voltage vector control, a DSP system, and both V/F and sensor-less vector control (SVC), offering 150% torque at 0.5Hz and precise speed regulation with 0.5% accuracy. Designed to withstand tough conditions, it features a conformal coating and supports a wide voltage range from 200V to 440V. Additionally, it comes equipped with RS-485 MODBUS communication, a built-in potentiometer, and compatibility with an external keypad.
Main Features
- Independently developed a new generation of general-purpose variable frequency drive (VFD) designed to control asynchronous AC induction motors.
- Utilize space vector voltage control technology and implement a DSP control system to enhance the product's reliability and stability.
- V/F Control, Sensor-less Vector Control (SVC), and Feedback Vector Control (FVC) are selectable.
- Automatic torque increase and slip adjustment.
- Rapid acceleration and deceleration capabilities.
- Delivers 150% torque at 0.5Hz.
- Offers accurate speed control within 0.5%.
- Supports a wide input voltage range from 200V to 440V.
- Features conformal coating for durability in harsh conditions.
- Includes built-in RS-485 MODBUS communication.
- Comes with a standard potentiometer and supports an external keypad.
| MODEL | Pioneer | |
| CAPACITY | 0.75-37KW | |
| INPUT | ||
| Frequency Range | ±5% (47.5 ~ 63Hz) | |
| Input Voltage | AC,1PH,220V(-15%)~240V(+10%) AC,3PH,380V(-15%)~440V(+10%) | |
| Rated Frequency | 50/60 Hz | |
| OUTPUT | ||
| AC Voltage Regulation (Batt. Mode) | 0 ~ Input Voltage | |
| Surge Power | 0.1 ~ 500Hz | |
| Efficiency (Peak) | Please refer to Rated Parameter table | |
| Transfer Time | Please refer to Rated Parameter table | |
| ENVIRONMENT | ||
| Noise Level | 50dBA max. | |
| Storage temperature | -20°C ~ 60°C | |
| Operation temperature | -10°C ~ 50°C (If temperarture is higher than 40°C, the output capacity will be derated 1% per 1°C increase) | |
| Storage humidity | <95%RH | |
| Operation humidity | <95%RH | |
| STANDARD | ||
| Safety | Standards:IEC 61800-5-1 | |
| BASIC PARAMETERS | ||
| V/F separation | Full separation, Half separation | |
| Highest frequency | Vector control: 0 ~ 500Hz | |
| Carrier frequency | 0.8KHz ~ 8KHz;Adjusted automatically according to the load characteristics | |
| Input frequency resolution | Digital setting: 0.01Hz; Analog setting: max. × 0.025% | |
| Control mode | Open-loop vector control (SVC) ; V/F control | |
| Starting torque | 0.5Hz/150%(SVC) | |
| Adjustable speed ratio | 1:100(SVC) | |
| Speed control accuracy | ±0.5%(SVC) | |
| Overload capability | 150% of rated current: 60 seconds ; 170% of rated current: 12 seconds ; 190% of rated current: 1.5 seconds | |
| Torque boost | Auto torque boost; Range of manual torque boost 0.1%~30.0% | |
| V/F curve | Three types: Linear, Multi-point, square curve (1.2 power, 1.4 power, 1.6 power, 1.8 power, 2 power) | |
| Acceleration and deceleration time | Linear and S-curve acceleration and deceleration modes available. The range of acceleration and deceleration time is 0.0~6500.0s. | |
| DC braking | Braking frequency: 0.00Hz ~ Maximum frequency Braking time: 0.0s~36.0s Braking current value: 0.0%~100.0% | |
| JOG control | JOG frequency range: 0.00Hz ~ Maximum frequency (5Hz in default). JOG acceleration and deceleration time: 0.0s~6500.0s. | |
| Built-in PID | Simplify the establishment of a closed-loop control system | |
| Automatic voltage regulation (AVR) | Keep the output voltage in stable when the grid voltage fluctuates. | |
| Stall prevention from overvoltage and overcurrent | The current and voltage are limited automatically during operation to prevent frequent tripping due to over-current and over-voltage. | |
| Rapid current limit | Reduce the risk of over-current faults to keep VFD operated normally. | |
| Torque limit and control | Limit the torque automatically during operation to prevent frequent tripping due to over-current. | |
| Braking unit | Built-in braking unit for 22KW and below models | |
| DISPLAY BUTTONS | ||
| Protective function | Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under-voltage protection, overheat protection, overload protection and etc. | |
| Key lock and function selections | It allows users to partially or fully lock the keys or define operated range for partial keys to prevent misoperation | |
| Keypad | Standard keypad | |
| SPECIAL FEATURES | ||
| Deceleration to stop | In case of instantaneous power drop, the load feedback energy is used to compensate the voltage drop to maintain the inverter’s normal operation over that short period. | |
| Rapid current limit | Reduce the risk of over-current faults to keep VFD operated normally. | |
| Timer control | Setting range: 0.0Min ~ 6500.0Min | |
| Communication | Modbus | |
| INPUT/OUTPUT | ||
| Command source | Operation panel, control terminal and serial communication port. | |
| Frequency source | 5 frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting and serial port setting. It can be switched in multiple ways | |
| Auxiliary frequency source | 5 kinds of auxiliary frequency sources. Auxiliary frequency fine tuning and frequency synthesis can be flexibly realized | |
| Input terminals | P series version: 5 digital input terminals, one of which supports high-speed pulse input up to 50kHz PM series version: 4 digital input terminals, one of which supports high-speed pulse input up to 50kHz | |
| Output terminals | 1 high-speed pulse output terminal supporting 50kHz step-wave signal output 1 relay output terminal 1 analog output terminal supporting 0~20mA current output or 0~10V voltage output | |
General
CAPACITY
| Pioneer | 0.75-37KW |
|---|
INPUT
Frequency Range
| Pioneer | ±5% (47.5 ~ 63Hz) |
|---|
Input Voltage
| Pioneer | AC,1PH,220V(-15%)~240V(+10%) AC,3PH,380V(-15%)~440V(+10%) |
|---|
Rated Frequency
| Pioneer | 50/60 Hz |
|---|
OUTPUT
AC Voltage Regulation (Batt. Mode)
| Pioneer | 0 ~ Input Voltage |
|---|
Surge Power
| Pioneer | 0.1 ~ 500Hz |
|---|
Efficiency (Peak)
| Pioneer | Please refer to Rated Parameter table |
|---|
Transfer Time
| Pioneer | Please refer to Rated Parameter table |
|---|
ENVIRONMENT
Noise Level
| Pioneer | 50dBA max. |
|---|
Storage temperature
| Pioneer | -20°C ~ 60°C |
|---|
Operation temperature
| Pioneer | -10°C ~ 50°C (If temperarture is higher than 40°C, the output capacity will be derated 1% per 1°C increase) |
|---|
Storage humidity
| Pioneer | <95%RH |
|---|
Operation humidity
| Pioneer | <95%RH |
|---|
STANDARD
Safety
| Pioneer | Standards:IEC 61800-5-1 |
|---|
BASIC PARAMETERS
V/F separation
| Pioneer | Full separation, Half separation |
|---|
Highest frequency
| Pioneer | Vector control: 0 ~ 500Hz |
|---|
Carrier frequency
| Pioneer | 0.8KHz ~ 8KHz;Adjusted automatically according to the load characteristics |
|---|
Input frequency resolution
| Pioneer | Digital setting: 0.01Hz; Analog setting: max. × 0.025% |
|---|
Control mode
| Pioneer | Open-loop vector control (SVC) ; V/F control |
|---|
Starting torque
| Pioneer | 0.5Hz/150%(SVC) |
|---|
Adjustable speed ratio
| Pioneer | 1:100(SVC) |
|---|
Speed control accuracy
| Pioneer | ±0.5%(SVC) |
|---|
Overload capability
| Pioneer | 150% of rated current: 60 seconds ; 170% of rated current: 12 seconds ; 190% of rated current: 1.5 seconds |
|---|
Torque boost
| Pioneer | Auto torque boost; Range of manual torque boost 0.1%~30.0% |
|---|
V/F curve
| Pioneer | Three types: Linear, Multi-point, square curve (1.2 power, 1.4 power, 1.6 power, 1.8 power, 2 power) |
|---|
Acceleration and deceleration time
| Pioneer | Linear and S-curve acceleration and deceleration modes available. The range of acceleration and deceleration time is 0.0~6500.0s. |
|---|
DC braking
| Pioneer | Braking frequency: 0.00Hz ~ Maximum frequency Braking time: 0.0s~36.0s Braking current value: 0.0%~100.0% |
|---|
JOG control
| Pioneer | JOG frequency range: 0.00Hz ~ Maximum frequency (5Hz in default). JOG acceleration and deceleration time: 0.0s~6500.0s. |
|---|
Built-in PID
| Pioneer | Simplify the establishment of a closed-loop control system |
|---|
Automatic voltage regulation (AVR)
| Pioneer | Keep the output voltage in stable when the grid voltage fluctuates. |
|---|
Stall prevention from overvoltage and overcurrent
| Pioneer | The current and voltage are limited automatically during operation to prevent frequent tripping due to over-current and over-voltage. |
|---|
Rapid current limit
| Pioneer | Reduce the risk of over-current faults to keep VFD operated normally. |
|---|
Torque limit and control
| Pioneer | Limit the torque automatically during operation to prevent frequent tripping due to over-current. |
|---|
Braking unit
| Pioneer | Built-in braking unit for 22KW and below models |
|---|
DISPLAY BUTTONS
Protective function
| Pioneer | Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under-voltage protection, overheat protection, overload protection and etc. |
|---|
Key lock and function selections
| Pioneer | It allows users to partially or fully lock the keys or define operated range for partial keys to prevent misoperation |
|---|
Keypad
| Pioneer | Standard keypad |
|---|
SPECIAL FEATURES
Deceleration to stop
| Pioneer | In case of instantaneous power drop, the load feedback energy is used to compensate the voltage drop to maintain the inverter’s normal operation over that short period. |
|---|
Rapid current limit
| Pioneer | Reduce the risk of over-current faults to keep VFD operated normally. |
|---|
Timer control
| Pioneer | Setting range: 0.0Min ~ 6500.0Min |
|---|
Communication
| Pioneer | Modbus |
|---|
INPUT/OUTPUT
Command source
| Pioneer | Operation panel, control terminal and serial communication port. |
|---|
Frequency source
| Pioneer | 5 frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting and serial port setting. It can be switched in multiple ways |
|---|
Auxiliary frequency source
| Pioneer | 5 kinds of auxiliary frequency sources. Auxiliary frequency fine tuning and frequency synthesis can be flexibly realized |
|---|
Input terminals
| Pioneer | P series version: 5 digital input terminals, one of which supports high-speed pulse input up to 50kHz PM series version: 4 digital input terminals, one of which supports high-speed pulse input up to 50kHz |
|---|
Output terminals
| Pioneer | 1 high-speed pulse output terminal supporting 50kHz step-wave signal output 1 relay output terminal 1 analog output terminal supporting 0~20mA current output or 0~10V voltage output |
|---|
| Brochure | Brochure | |
| Manual | Pioneer |