Galleon II 3P/3P 10K-40K UL
3-phase in / 3-phase out
Galleon II 3P/3P 10K-40K UL series are certified with UL and provides output power factor 1.0. Equipped with 4.3” touch colored LCD, this series are easy and comprehensive to set up functions and modify all setting parameters through the touch screen.
Main Features
  • True double-conversion
  • DSP technology guarantees high performance
  • 4.3 LCD for comprehensive ups information
  • Active power factor correction in all phases
  • 50hz/60hz frequency converter mode
  • eco mode operation for energy saving (eco)
  • Emergency power off function (epo)
  • Generator compatible
  • Snmp+usb multiple communications
  • 3-stage extendable charging design for optimized battery performance
  • Maintenance bypass available
  • Parallel operation with common battery
  • Dual AC inputs
  • Optional parallel operation
General
CAPACITY
Galleon II-3/3 10K(L)10 KVA / 10 KW
Galleon II-3/3 15K(L)15 KVA / 15 KW
Galleon II-3/3 20K(L)20KVA/20KW
Galleon II-3/3 30KL30 KVA / 30 KW
Galleon II-3/3 40KL40 KVA / 40 KW
PHASE
Galleon II-3/3 10K(L)3-phase in/3-phase out
Galleon II-3/3 15K(L)3-phase in/3-phase out
Galleon II-3/3 20K(L)3-phase in/3-phase out
Galleon II-3/3 30KL3-phase in/3-phase out
Galleon II-3/3 40KL3-phase in/3-phase out
PARALLEL CAPABILITY
Galleon II-3/3 10K(L)up to 3 units in parallel
Galleon II-3/3 15K(L)up to 3 units in parallel
Galleon II-3/3 20K(L)up to 3 units in parallel
Galleon II-3/3 30KLup to 3 units in parallel
Galleon II-3/3 40KLup to 3 units in parallel
INPUT
Voltage Range
Galleon II-3/3 10K(L)190 - 520 VAC (3-phase) @ 50% load; 305 - 478 VAC (3-phase) @ 100% load
Galleon II-3/3 15K(L)190 - 520 VAC (3-phase) @ 50% load; 305 - 478 VAC (3-phase) @ 100% load
Galleon II-3/3 20K(L)190 - 520 VAC (3-phase) @ 50% load; 305 - 478 VAC (3-phase) @ 100% load
Galleon II-3/3 30KL190 - 520 VAC (3-phase) @ 50% load; 305 - 478 VAC (3-phase) @ 100% load
Galleon II-3/3 40KL190 - 520 VAC (3-phase) @ 50% load; 305 - 478 VAC (3-phase) @ 100% load
Nominal Voltage
Galleon II-3/3 10K(L)3 x 400 VAC ( 3 Ph +N)
Galleon II-3/3 15K(L)3 x 400 VAC ( 3 Ph +N)
Galleon II-3/3 20K(L)3 x 400 VAC ( 3 Ph +N)
Galleon II-3/3 30KL3 x 400 VAC ( 3 Ph +N)
Galleon II-3/3 40KL3 x 400 VAC ( 3 Ph +N)
Frequency Range
Galleon II-3/3 10K(L)46~54 Hz or 56~64Hz
Galleon II-3/3 15K(L)46~54 Hz or 56~64Hz
Galleon II-3/3 20K(L)46~54 Hz or 56~64Hz
Galleon II-3/3 30KL46~54 Hz or 56~64Hz
Galleon II-3/3 40KL46~54 Hz or 56~64Hz
Power Factor
Galleon II-3/3 10K(L)≧ 0.99 @ 100% load
Galleon II-3/3 15K(L)≧ 0.99 @ 100% load
Galleon II-3/3 20K(L)≧ 0.99 @ 100% load
Galleon II-3/3 30KL≧ 0.99 @ 100% load
Galleon II-3/3 40KL≧ 0.99 @ 100% load
OUTPUT
Output Voltage
Galleon II-3/3 10K(L)3 x 360*/380/400/415 (3 Ph +N)
Galleon II-3/3 15K(L)3 x 360*/380/400/415 (3 Ph +N)
Galleon II-3/3 20K(L)3 x 360*/380/400/415 (3 Ph +N)
Galleon II-3/3 30KL3 x 360*/380/400/415 (3 Ph +N)
Galleon II-3/3 40KL3 x 360*/380/400/415 (3 Ph +N)
AC Voltage Regulation (Batt. Mode)
Galleon II-3/3 10K(L)± 1%
Galleon II-3/3 15K(L)± 1%
Galleon II-3/3 20K(L)± 1%
Galleon II-3/3 30KL± 1%
Galleon II-3/3 40KL± 1%
Frequency Range (Batt. Mode)
Galleon II-3/3 10K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon II-3/3 15K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon II-3/3 20K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon II-3/3 30KL50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon II-3/3 40KL50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Transfer Time AC Mode to Battery Mode
Galleon II-3/3 10K(L)zero
Galleon II-3/3 15K(L)zero
Galleon II-3/3 20K(L)zero
Galleon II-3/3 30KLzero
Galleon II-3/3 40KLzero
Transfer Time Inverter to Bypass
Galleon II-3/3 10K(L)zero
Galleon II-3/3 15K(L)zero
Galleon II-3/3 20K(L)zero
Galleon II-3/3 30KLzero
Galleon II-3/3 40KLzero
Waveform (Batt. Mode)
Galleon II-3/3 10K(L)Pure Sine Wave
Galleon II-3/3 15K(L)Pure Sine Wave
Galleon II-3/3 20K(L)Pure Sine Wave
Galleon II-3/3 30KLPure Sine Wave
Galleon II-3/3 40KLPure Sine Wave
Current Crest Ratio
Galleon II-3/3 10K(L)3:1 (max.)
Galleon II-3/3 15K(L)3:1 (max.)
Galleon II-3/3 20K(L)3:1 (max.)
Galleon II-3/3 30KL3:1 (max.)
Galleon II-3/3 40KL3:1 (max.)
Harmonic Distortion
Galleon II-3/3 10K(L)≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)
Galleon II-3/3 15K(L)≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)
Galleon II-3/3 20K(L)≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)
Galleon II-3/3 30KL≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)
Galleon II-3/3 40KL≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)
Frequency Range (Synchronized Range)
Galleon II-3/3 10K(L)46~54Hz or 56~64Hz
Galleon II-3/3 15K(L)46~54Hz or 56~64Hz
Galleon II-3/3 20K(L)46~54Hz or 56~64Hz
Galleon II-3/3 30KL46~54Hz or 56~64Hz
Galleon II-3/3 40KL46~54Hz or 56~64Hz
Overload AC Mode
Galleon II-3/3 10K(L)100-110% for 60 min, 110-125% for 10 min, >150% immediately
Galleon II-3/3 15K(L)100-110% for 60 min, 110-125% for 10 min, >150% immediately
Galleon II-3/3 20K(L)100-110% for 60 min, 110-125% for 10 min, >150% immediately
Galleon II-3/3 30KL100-110% for 60 min, 110-125% for 10 min, >150% immediately
Galleon II-3/3 40KL100-110% for 60 min, 110-125% for 10 min, >150% immediately
Overload Battery Mode
Galleon II-3/3 10K(L)100-110% for 60 min, 110-125% for 10 min, >150% immediately
Galleon II-3/3 15K(L)100-110% for 60 min, 110-125% for 10 min, >150% immediately
Galleon II-3/3 20K(L)100-110% for 60 min, 110-125% for 10 min, >150% immediately
Galleon II-3/3 30KL100-110% for 60 min, 110-125% for 10 min, >150% immediately
Galleon II-3/3 40KL100-110% for 60 min, 110-125% for 10 min, >150% immediately
EFFICIENCY
Battery Mode
Galleon II-3/3 10K(L)94.5%
Galleon II-3/3 15K(L)94.5%
Galleon II-3/3 20K(L)94.5%
Galleon II-3/3 30KL94.5%
Galleon II-3/3 40KL94.5%
ECO Mode
Galleon II-3/3 10K(L)98.5%
Galleon II-3/3 15K(L)98.5%
Galleon II-3/3 20K(L)98.5%
Galleon II-3/3 30KL98.5%
Galleon II-3/3 40KL98.5%
AC Mode
Galleon II-3/3 10K(L)95.5%
Galleon II-3/3 15K(L)95.5%
Galleon II-3/3 20K(L)95.5%
Galleon II-3/3 30KL95.5%
Galleon II-3/3 40KL95.5%
BATTERY
Long-run Model Model-Battery Type
Galleon II-3/3 10K(L)Depending on the capacity of external batteries
Galleon II-3/3 15K(L)Depending on the capacity of external batteries
Galleon II-3/3 20K(L)Depending on the capacity of external batteries
Galleon II-3/3 30KLDepending on the capacity of external batteries
Galleon II-3/3 40KLDepending on the capacity of external batteries
Long-run Model Model-Charging Current (max.)
Galleon II-3/3 10K(L)1A ~ 12A (Adjustable)
Galleon II-3/3 15K(L)1A ~ 12A (Adjustable)
Galleon II-3/3 20K(L)1A ~ 12A (Adjustable)
Galleon II-3/3 30KL1A ~ 12A (Adjustable)
Galleon II-3/3 40KL1A ~ 12A (Adjustable)
Long-run Model Model-Charging Voltage
Galleon II-3/3 10K(L)136.5VDC ±10%
Galleon II-3/3 15K(L)±13.65V*N (N = 16~20)
Galleon II-3/3 20K(L)±13.65V*N (N = 16~20)
Galleon II-3/3 30KL±13.65V*N (N = 16~20)
Galleon II-3/3 40KL±13.65V*N (N = 16~20)
Long-run Model Model-Numbers
Galleon II-3/3 10K(L)20 pcs
Galleon II-3/3 15K(L)32~40 pcs (Adjustable)
Galleon II-3/3 20K(L)32~40 pcs (Adjustable)
Galleon II-3/3 30KL32~40 pcs (Adjustable)
Galleon II-3/3 40KL32~40 pcs (Adjustable)
Standard Model Battery Type
Galleon II-3/3 10K(L)12V/9Ah
Galleon II-3/3 15K(L)12V/9Ah
Galleon II-3/3 20K(L)12V/9Ah
Galleon II-3/3 30KL12V/7Ah
Galleon II-3/3 40KL12V/9Ah
Standard Model Charging Current (max.)
Galleon II-3/3 10K(L)1A~12A (Adjustable)
Galleon II-3/3 15K(L)1A~12A (Adjustable)
Galleon II-3/3 20K(L)1A~12A (Adjustable)
Galleon II-3/3 30KL1A~12A (Adjustable)
Galleon II-3/3 40KL1A~12A (Adjustable)
Standard Model Charging Voltage
Galleon II-3/3 10K(L)+/-136.5 VDC ± 10%
Galleon II-3/3 15K(L)+/-218 VDC ± 10%
Galleon II-3/3 20K(L)+/-218 VDC ± 10%
Galleon II-3/3 30KL+/-218 VDC ± 10%
Galleon II-3/3 40KL+/-218 VDC ± 10%
Standard Model Numbers
Galleon II-3/3 10K(L)(10+10)pcs
Galleon II-3/3 15K(L)(16+16)pcs
Galleon II-3/3 20K(L)(16+16)pcs
Galleon II-3/3 30KL(16+16)pcs x 2 strings
Galleon II-3/3 40KL(16+16)pcs x 2 strings
Standard Model Typical Recharge Time
Galleon II-3/3 10K(L)9 hours recover to 90% capacity
Galleon II-3/3 15K(L)9 hours recover to 90% capacity
Galleon II-3/3 20K(L)9 hours recover to 90% capacity
Galleon II-3/3 30KL9 hours recover to 90% capacity
Galleon II-3/3 40KL9 hours recover to 90% capacity
INDICATORS
LCD Panel
Galleon II-3/3 10K(L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Galleon II-3/3 15K(L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Galleon II-3/3 20K(L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Galleon II-3/3 30KLUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Galleon II-3/3 40KLUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ENVIRONMENT
Operating Temperature
Galleon II-3/3 10K(L)0~40°C
Galleon II-3/3 15K(L)0~40°C
Galleon II-3/3 20K(L)0~40°C
Galleon II-3/3 30KL0~40°C
Galleon II-3/3 40KL0~40°C
Operating Humidity
Galleon II-3/3 10K(L)<95% and non-condersing
Galleon II-3/3 15K(L)<95% and non-condersing
Galleon II-3/3 20K(L)<95% and non-condersing
Galleon II-3/3 30KL<95% and non-condersing
Galleon II-3/3 40KL<95% and non-condersing
Noise Level
Galleon II-3/3 10K(L)Less than 55dB @ 1 Meter
Galleon II-3/3 15K(L)Less than 58dB @ 1 Meter
Galleon II-3/3 20K(L)Less than 58dB @ 1 Meter
Galleon II-3/3 30KLLess than 65dB @ 1 Meter
Galleon II-3/3 40KLLess than 70dB @ 1 Meter
PHYSICAL
Standard Model Dimension, D X W X H (mm)
Galleon II-3/3 10K(L)626 x 250 x 750
Galleon II-3/3 15K(L)626 x 250 x 750
Galleon II-3/3 20K(L)626 x 250 x 750
Galleon II-3/3 30KL815 x 300 x 1000
Galleon II-3/3 40KL815 x 300 x 1000
Standard Model Net Weight (kgs)
Galleon II-3/3 10K(L)124
Galleon II-3/3 15K(L)139
Galleon II-3/3 20K(L)139
Galleon II-3/3 30KL225
Galleon II-3/3 40KL250
Long-run Model Dimension, D X W X H (mm)
Galleon II-3/3 10K(L)626 x 250 x 750
Galleon II-3/3 15K(L)626 x 250 x 750
Galleon II-3/3 20K(L)626 x 250 x 750
Galleon II-3/3 30KL815 x 300 x 1000
Galleon II-3/3 40KL815 x 300 x 1000
Long-run Model Net Weight (kgs)
Galleon II-3/3 10K(L)28
Galleon II-3/3 15K(L)43
Galleon II-3/3 20K(L)43
Galleon II-3/3 30KL60
Galleon II-3/3 40KL61
MANAGEMENT
Optional SNMP
Galleon II-3/3 10K(L)Power management from SNMP manager and web browser
Galleon II-3/3 15K(L)Power management from SNMP manager and web browser
Galleon II-3/3 20K(L)Power management from SNMP manager and web browser
Galleon II-3/3 30KLPower management from SNMP manager and web browser
Galleon II-3/3 40KLPower management from SNMP manager and web browser
Smart RS-232 / USB
Galleon II-3/3 10K(L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon II-3/3 15K(L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon II-3/3 20K(L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon II-3/3 30KLSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon II-3/3 40KLSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Brochure Galleon II 3P/3P 10K-40K UL-Brochure
Manual GalleonII3P3P10K-40KUL-manual
Related Products