95
Galleon II 3P/3P 10K-40K UL
3-phase in / 3-phase out
Galleon II 3P/3P 10K-40K UL series are certified with UL and provides output power factor 1.0. Equipped with 4.3” touch colored LCD, this series are easy and comprehensive to set up functions and modify all setting parameters through the touch screen.


Main Features
- True double-conversion
- DSP technology guarantees high performance
- 4.3 LCD for comprehensive ups information
- Active power factor correction in all phases
- 50hz/60hz frequency converter mode
- eco mode operation for energy saving (eco)
- Emergency power off function (epo)
- Generator compatible
- Snmp+usb multiple communications
- 3-stage extendable charging design for optimized battery performance
- Maintenance bypass available
- Parallel operation with common battery
- Dual AC inputs
- Optional parallel operation
MODEL | Galleon II-3/3 10K(L) | Galleon II-3/3 15K(L) | Galleon II-3/3 20K(L) | Galleon II-3/3 30KL | Galleon II-3/3 40KL | |
CAPACITY | 10 KVA / 10 KW | 15 KVA / 15 KW | 20KVA/20KW | 30 KVA / 30 KW | 40 KVA / 40 KW | |
PHASE | 3-phase in/3-phase out | 3-phase in/3-phase out | 3-phase in/3-phase out | 3-phase in/3-phase out | 3-phase in/3-phase out | |
PARALLEL CAPABILITY | up to 3 units in parallel | up to 3 units in parallel | up to 3 units in parallel | up to 3 units in parallel | up to 3 units in parallel | |
INPUT | ||||||
Voltage Range | 190 - 520 VAC (3-phase) @ 50% load; 305 - 478 VAC (3-phase) @ 100% load | 190 - 520 VAC (3-phase) @ 50% load; 305 - 478 VAC (3-phase) @ 100% load | 190 - 520 VAC (3-phase) @ 50% load; 305 - 478 VAC (3-phase) @ 100% load | 190 - 520 VAC (3-phase) @ 50% load; 305 - 478 VAC (3-phase) @ 100% load | 190 - 520 VAC (3-phase) @ 50% load; 305 - 478 VAC (3-phase) @ 100% load | |
Nominal Voltage | 3 x 400 VAC ( 3 Ph +N) | 3 x 400 VAC ( 3 Ph +N) | 3 x 400 VAC ( 3 Ph +N) | 3 x 400 VAC ( 3 Ph +N) | 3 x 400 VAC ( 3 Ph +N) | |
Frequency Range | 46~54 Hz or 56~64Hz | 46~54 Hz or 56~64Hz | 46~54 Hz or 56~64Hz | 46~54 Hz or 56~64Hz | 46~54 Hz or 56~64Hz | |
Power Factor | ≧ 0.99 @ 100% load | ≧ 0.99 @ 100% load | ≧ 0.99 @ 100% load | ≧ 0.99 @ 100% load | ≧ 0.99 @ 100% load | |
OUTPUT | ||||||
Output Voltage | 3 x 360*/380/400/415 (3 Ph +N) | 3 x 360*/380/400/415 (3 Ph +N) | 3 x 360*/380/400/415 (3 Ph +N) | 3 x 360*/380/400/415 (3 Ph +N) | 3 x 360*/380/400/415 (3 Ph +N) | |
AC Voltage Regulation (Batt. Mode) | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | |
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |
Transfer Time | AC Mode to Battery Mode | zero | zero | zero | zero | zero |
Transfer Time | Inverter to Bypass | zero | zero | zero | zero | zero |
Waveform (Batt. Mode) | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | |
Current Crest Ratio | 3:1 (max.) | 3:1 (max.) | 3:1 (max.) | 3:1 (max.) | 3:1 (max.) | |
Harmonic Distortion | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) | |
Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz | |
Overload | AC Mode | 100-110% for 60 min, 110-125% for 10 min, >150% immediately | 100-110% for 60 min, 110-125% for 10 min, >150% immediately | 100-110% for 60 min, 110-125% for 10 min, >150% immediately | 100-110% for 60 min, 110-125% for 10 min, >150% immediately | 100-110% for 60 min, 110-125% for 10 min, >150% immediately |
Overload | Battery Mode | 100-110% for 60 min, 110-125% for 10 min, >150% immediately | 100-110% for 60 min, 110-125% for 10 min, >150% immediately | 100-110% for 60 min, 110-125% for 10 min, >150% immediately | 100-110% for 60 min, 110-125% for 10 min, >150% immediately | 100-110% for 60 min, 110-125% for 10 min, >150% immediately |
EFFICIENCY | ||||||
Battery Mode | 94.5% | 94.5% | 94.5% | 94.5% | 94.5% | |
ECO Mode | 98.5% | 98.5% | 98.5% | 98.5% | 98.5% | |
AC Mode | 95.5% | 95.5% | 95.5% | 95.5% | 95.5% | |
BATTERY | ||||||
Long-run Model | Model-Battery Type | Depending on the capacity of external batteries | Depending on the capacity of external batteries | Depending on the capacity of external batteries | Depending on the capacity of external batteries | Depending on the capacity of external batteries |
Long-run Model | Model-Charging Current (max.) | 1A ~ 12A (Adjustable) | 1A ~ 12A (Adjustable) | 1A ~ 12A (Adjustable) | 1A ~ 12A (Adjustable) | 1A ~ 12A (Adjustable) |
Long-run Model | Model-Charging Voltage | 136.5VDC ±10% | ±13.65V*N (N = 16~20) | ±13.65V*N (N = 16~20) | ±13.65V*N (N = 16~20) | ±13.65V*N (N = 16~20) |
Long-run Model | Model-Numbers | 20 pcs | 32~40 pcs (Adjustable) | 32~40 pcs (Adjustable) | 32~40 pcs (Adjustable) | 32~40 pcs (Adjustable) |
Standard Model | Battery Type | 12V/9Ah | 12V/9Ah | 12V/9Ah | 12V/7Ah | 12V/9Ah |
Standard Model | Charging Current (max.) | 1A~12A (Adjustable) | 1A~12A (Adjustable) | 1A~12A (Adjustable) | 1A~12A (Adjustable) | 1A~12A (Adjustable) |
Standard Model | Charging Voltage | +/-136.5 VDC ± 10% | +/-218 VDC ± 10% | +/-218 VDC ± 10% | +/-218 VDC ± 10% | +/-218 VDC ± 10% |
Standard Model | Numbers | (10+10)pcs | (16+16)pcs | (16+16)pcs | (16+16)pcs x 2 strings | (16+16)pcs x 2 strings |
Standard Model | Typical Recharge Time | 9 hours recover to 90% capacity | 9 hours recover to 90% capacity | 9 hours recover to 90% capacity | 9 hours recover to 90% capacity | 9 hours recover to 90% capacity |
INDICATORS | ||||||
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | |
ENVIRONMENT | ||||||
Operating Temperature | 0~40°C | 0~40°C | 0~40°C | 0~40°C | 0~40°C | |
Operating Humidity | <95% and non-condersing | <95% and non-condersing | <95% and non-condersing | <95% and non-condersing | <95% and non-condersing | |
Noise Level | Less than 55dB @ 1 Meter | Less than 58dB @ 1 Meter | Less than 58dB @ 1 Meter | Less than 65dB @ 1 Meter | Less than 70dB @ 1 Meter | |
PHYSICAL | ||||||
Standard Model | Dimension, D X W X H (mm) | 626 x 250 x 750 | 626 x 250 x 750 | 626 x 250 x 750 | 815 x 300 x 1000 | 815 x 300 x 1000 |
Standard Model | Net Weight (kgs) | 124 | 139 | 139 | 225 | 250 |
Long-run Model | Dimension, D X W X H (mm) | 626 x 250 x 750 | 626 x 250 x 750 | 626 x 250 x 750 | 815 x 300 x 1000 | 815 x 300 x 1000 |
Long-run Model | Net Weight (kgs) | 28 | 43 | 43 | 60 | 61 |
MANAGEMENT | ||||||
Optional SNMP | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | |
Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
General
CAPACITY
Galleon II-3/3 10K(L) | 10 KVA / 10 KW |
---|---|
Galleon II-3/3 15K(L) | 15 KVA / 15 KW |
Galleon II-3/3 20K(L) | 20KVA/20KW |
Galleon II-3/3 30KL | 30 KVA / 30 KW |
Galleon II-3/3 40KL | 40 KVA / 40 KW |
PHASE
Galleon II-3/3 10K(L) | 3-phase in/3-phase out |
---|---|
Galleon II-3/3 15K(L) | 3-phase in/3-phase out |
Galleon II-3/3 20K(L) | 3-phase in/3-phase out |
Galleon II-3/3 30KL | 3-phase in/3-phase out |
Galleon II-3/3 40KL | 3-phase in/3-phase out |
PARALLEL CAPABILITY
Galleon II-3/3 10K(L) | up to 3 units in parallel |
---|---|
Galleon II-3/3 15K(L) | up to 3 units in parallel |
Galleon II-3/3 20K(L) | up to 3 units in parallel |
Galleon II-3/3 30KL | up to 3 units in parallel |
Galleon II-3/3 40KL | up to 3 units in parallel |
INPUT
Voltage Range
Galleon II-3/3 10K(L) | 190 - 520 VAC (3-phase) @ 50% load; 305 - 478 VAC (3-phase) @ 100% load |
---|---|
Galleon II-3/3 15K(L) | 190 - 520 VAC (3-phase) @ 50% load; 305 - 478 VAC (3-phase) @ 100% load |
Galleon II-3/3 20K(L) | 190 - 520 VAC (3-phase) @ 50% load; 305 - 478 VAC (3-phase) @ 100% load |
Galleon II-3/3 30KL | 190 - 520 VAC (3-phase) @ 50% load; 305 - 478 VAC (3-phase) @ 100% load |
Galleon II-3/3 40KL | 190 - 520 VAC (3-phase) @ 50% load; 305 - 478 VAC (3-phase) @ 100% load |
Nominal Voltage
Galleon II-3/3 10K(L) | 3 x 400 VAC ( 3 Ph +N) |
---|---|
Galleon II-3/3 15K(L) | 3 x 400 VAC ( 3 Ph +N) |
Galleon II-3/3 20K(L) | 3 x 400 VAC ( 3 Ph +N) |
Galleon II-3/3 30KL | 3 x 400 VAC ( 3 Ph +N) |
Galleon II-3/3 40KL | 3 x 400 VAC ( 3 Ph +N) |
Frequency Range
Galleon II-3/3 10K(L) | 46~54 Hz or 56~64Hz |
---|---|
Galleon II-3/3 15K(L) | 46~54 Hz or 56~64Hz |
Galleon II-3/3 20K(L) | 46~54 Hz or 56~64Hz |
Galleon II-3/3 30KL | 46~54 Hz or 56~64Hz |
Galleon II-3/3 40KL | 46~54 Hz or 56~64Hz |
Power Factor
Galleon II-3/3 10K(L) | ≧ 0.99 @ 100% load |
---|---|
Galleon II-3/3 15K(L) | ≧ 0.99 @ 100% load |
Galleon II-3/3 20K(L) | ≧ 0.99 @ 100% load |
Galleon II-3/3 30KL | ≧ 0.99 @ 100% load |
Galleon II-3/3 40KL | ≧ 0.99 @ 100% load |
OUTPUT
Output Voltage
Galleon II-3/3 10K(L) | 3 x 360*/380/400/415 (3 Ph +N) |
---|---|
Galleon II-3/3 15K(L) | 3 x 360*/380/400/415 (3 Ph +N) |
Galleon II-3/3 20K(L) | 3 x 360*/380/400/415 (3 Ph +N) |
Galleon II-3/3 30KL | 3 x 360*/380/400/415 (3 Ph +N) |
Galleon II-3/3 40KL | 3 x 360*/380/400/415 (3 Ph +N) |
AC Voltage Regulation (Batt. Mode)
Galleon II-3/3 10K(L) | ± 1% |
---|---|
Galleon II-3/3 15K(L) | ± 1% |
Galleon II-3/3 20K(L) | ± 1% |
Galleon II-3/3 30KL | ± 1% |
Galleon II-3/3 40KL | ± 1% |
Frequency Range (Batt. Mode)
Galleon II-3/3 10K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
---|---|
Galleon II-3/3 15K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon II-3/3 20K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon II-3/3 30KL | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon II-3/3 40KL | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Transfer Time AC Mode to Battery Mode
Galleon II-3/3 10K(L) | zero |
---|---|
Galleon II-3/3 15K(L) | zero |
Galleon II-3/3 20K(L) | zero |
Galleon II-3/3 30KL | zero |
Galleon II-3/3 40KL | zero |
Transfer Time Inverter to Bypass
Galleon II-3/3 10K(L) | zero |
---|---|
Galleon II-3/3 15K(L) | zero |
Galleon II-3/3 20K(L) | zero |
Galleon II-3/3 30KL | zero |
Galleon II-3/3 40KL | zero |
Waveform (Batt. Mode)
Galleon II-3/3 10K(L) | Pure Sine Wave |
---|---|
Galleon II-3/3 15K(L) | Pure Sine Wave |
Galleon II-3/3 20K(L) | Pure Sine Wave |
Galleon II-3/3 30KL | Pure Sine Wave |
Galleon II-3/3 40KL | Pure Sine Wave |
Current Crest Ratio
Galleon II-3/3 10K(L) | 3:1 (max.) |
---|---|
Galleon II-3/3 15K(L) | 3:1 (max.) |
Galleon II-3/3 20K(L) | 3:1 (max.) |
Galleon II-3/3 30KL | 3:1 (max.) |
Galleon II-3/3 40KL | 3:1 (max.) |
Harmonic Distortion
Galleon II-3/3 10K(L) | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) |
---|---|
Galleon II-3/3 15K(L) | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) |
Galleon II-3/3 20K(L) | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) |
Galleon II-3/3 30KL | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) |
Galleon II-3/3 40KL | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) |
Frequency Range (Synchronized Range)
Galleon II-3/3 10K(L) | 46~54Hz or 56~64Hz |
---|---|
Galleon II-3/3 15K(L) | 46~54Hz or 56~64Hz |
Galleon II-3/3 20K(L) | 46~54Hz or 56~64Hz |
Galleon II-3/3 30KL | 46~54Hz or 56~64Hz |
Galleon II-3/3 40KL | 46~54Hz or 56~64Hz |
Overload AC Mode
Galleon II-3/3 10K(L) | 100-110% for 60 min, 110-125% for 10 min, >150% immediately |
---|---|
Galleon II-3/3 15K(L) | 100-110% for 60 min, 110-125% for 10 min, >150% immediately |
Galleon II-3/3 20K(L) | 100-110% for 60 min, 110-125% for 10 min, >150% immediately |
Galleon II-3/3 30KL | 100-110% for 60 min, 110-125% for 10 min, >150% immediately |
Galleon II-3/3 40KL | 100-110% for 60 min, 110-125% for 10 min, >150% immediately |
Overload Battery Mode
Galleon II-3/3 10K(L) | 100-110% for 60 min, 110-125% for 10 min, >150% immediately |
---|---|
Galleon II-3/3 15K(L) | 100-110% for 60 min, 110-125% for 10 min, >150% immediately |
Galleon II-3/3 20K(L) | 100-110% for 60 min, 110-125% for 10 min, >150% immediately |
Galleon II-3/3 30KL | 100-110% for 60 min, 110-125% for 10 min, >150% immediately |
Galleon II-3/3 40KL | 100-110% for 60 min, 110-125% for 10 min, >150% immediately |
EFFICIENCY
Battery Mode
Galleon II-3/3 10K(L) | 94.5% |
---|---|
Galleon II-3/3 15K(L) | 94.5% |
Galleon II-3/3 20K(L) | 94.5% |
Galleon II-3/3 30KL | 94.5% |
Galleon II-3/3 40KL | 94.5% |
ECO Mode
Galleon II-3/3 10K(L) | 98.5% |
---|---|
Galleon II-3/3 15K(L) | 98.5% |
Galleon II-3/3 20K(L) | 98.5% |
Galleon II-3/3 30KL | 98.5% |
Galleon II-3/3 40KL | 98.5% |
AC Mode
Galleon II-3/3 10K(L) | 95.5% |
---|---|
Galleon II-3/3 15K(L) | 95.5% |
Galleon II-3/3 20K(L) | 95.5% |
Galleon II-3/3 30KL | 95.5% |
Galleon II-3/3 40KL | 95.5% |
BATTERY
Long-run Model Model-Battery Type
Galleon II-3/3 10K(L) | Depending on the capacity of external batteries |
---|---|
Galleon II-3/3 15K(L) | Depending on the capacity of external batteries |
Galleon II-3/3 20K(L) | Depending on the capacity of external batteries |
Galleon II-3/3 30KL | Depending on the capacity of external batteries |
Galleon II-3/3 40KL | Depending on the capacity of external batteries |
Long-run Model Model-Charging Current (max.)
Galleon II-3/3 10K(L) | 1A ~ 12A (Adjustable) |
---|---|
Galleon II-3/3 15K(L) | 1A ~ 12A (Adjustable) |
Galleon II-3/3 20K(L) | 1A ~ 12A (Adjustable) |
Galleon II-3/3 30KL | 1A ~ 12A (Adjustable) |
Galleon II-3/3 40KL | 1A ~ 12A (Adjustable) |
Long-run Model Model-Charging Voltage
Galleon II-3/3 10K(L) | 136.5VDC ±10% |
---|---|
Galleon II-3/3 15K(L) | ±13.65V*N (N = 16~20) |
Galleon II-3/3 20K(L) | ±13.65V*N (N = 16~20) |
Galleon II-3/3 30KL | ±13.65V*N (N = 16~20) |
Galleon II-3/3 40KL | ±13.65V*N (N = 16~20) |
Long-run Model Model-Numbers
Galleon II-3/3 10K(L) | 20 pcs |
---|---|
Galleon II-3/3 15K(L) | 32~40 pcs (Adjustable) |
Galleon II-3/3 20K(L) | 32~40 pcs (Adjustable) |
Galleon II-3/3 30KL | 32~40 pcs (Adjustable) |
Galleon II-3/3 40KL | 32~40 pcs (Adjustable) |
Standard Model Battery Type
Galleon II-3/3 10K(L) | 12V/9Ah |
---|---|
Galleon II-3/3 15K(L) | 12V/9Ah |
Galleon II-3/3 20K(L) | 12V/9Ah |
Galleon II-3/3 30KL | 12V/7Ah |
Galleon II-3/3 40KL | 12V/9Ah |
Standard Model Charging Current (max.)
Galleon II-3/3 10K(L) | 1A~12A (Adjustable) |
---|---|
Galleon II-3/3 15K(L) | 1A~12A (Adjustable) |
Galleon II-3/3 20K(L) | 1A~12A (Adjustable) |
Galleon II-3/3 30KL | 1A~12A (Adjustable) |
Galleon II-3/3 40KL | 1A~12A (Adjustable) |
Standard Model Charging Voltage
Galleon II-3/3 10K(L) | +/-136.5 VDC ± 10% |
---|---|
Galleon II-3/3 15K(L) | +/-218 VDC ± 10% |
Galleon II-3/3 20K(L) | +/-218 VDC ± 10% |
Galleon II-3/3 30KL | +/-218 VDC ± 10% |
Galleon II-3/3 40KL | +/-218 VDC ± 10% |
Standard Model Numbers
Galleon II-3/3 10K(L) | (10+10)pcs |
---|---|
Galleon II-3/3 15K(L) | (16+16)pcs |
Galleon II-3/3 20K(L) | (16+16)pcs |
Galleon II-3/3 30KL | (16+16)pcs x 2 strings |
Galleon II-3/3 40KL | (16+16)pcs x 2 strings |
Standard Model Typical Recharge Time
Galleon II-3/3 10K(L) | 9 hours recover to 90% capacity |
---|---|
Galleon II-3/3 15K(L) | 9 hours recover to 90% capacity |
Galleon II-3/3 20K(L) | 9 hours recover to 90% capacity |
Galleon II-3/3 30KL | 9 hours recover to 90% capacity |
Galleon II-3/3 40KL | 9 hours recover to 90% capacity |
INDICATORS
LCD Panel
Galleon II-3/3 10K(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
---|---|
Galleon II-3/3 15K(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon II-3/3 20K(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon II-3/3 30KL | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon II-3/3 40KL | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
ENVIRONMENT
Operating Temperature
Galleon II-3/3 10K(L) | 0~40°C |
---|---|
Galleon II-3/3 15K(L) | 0~40°C |
Galleon II-3/3 20K(L) | 0~40°C |
Galleon II-3/3 30KL | 0~40°C |
Galleon II-3/3 40KL | 0~40°C |
Operating Humidity
Galleon II-3/3 10K(L) | <95% and non-condersing |
---|---|
Galleon II-3/3 15K(L) | <95% and non-condersing |
Galleon II-3/3 20K(L) | <95% and non-condersing |
Galleon II-3/3 30KL | <95% and non-condersing |
Galleon II-3/3 40KL | <95% and non-condersing |
Noise Level
Galleon II-3/3 10K(L) | Less than 55dB @ 1 Meter |
---|---|
Galleon II-3/3 15K(L) | Less than 58dB @ 1 Meter |
Galleon II-3/3 20K(L) | Less than 58dB @ 1 Meter |
Galleon II-3/3 30KL | Less than 65dB @ 1 Meter |
Galleon II-3/3 40KL | Less than 70dB @ 1 Meter |
PHYSICAL
Standard Model Dimension, D X W X H (mm)
Galleon II-3/3 10K(L) | 626 x 250 x 750 |
---|---|
Galleon II-3/3 15K(L) | 626 x 250 x 750 |
Galleon II-3/3 20K(L) | 626 x 250 x 750 |
Galleon II-3/3 30KL | 815 x 300 x 1000 |
Galleon II-3/3 40KL | 815 x 300 x 1000 |
Standard Model Net Weight (kgs)
Galleon II-3/3 10K(L) | 124 |
---|---|
Galleon II-3/3 15K(L) | 139 |
Galleon II-3/3 20K(L) | 139 |
Galleon II-3/3 30KL | 225 |
Galleon II-3/3 40KL | 250 |
Long-run Model Dimension, D X W X H (mm)
Galleon II-3/3 10K(L) | 626 x 250 x 750 |
---|---|
Galleon II-3/3 15K(L) | 626 x 250 x 750 |
Galleon II-3/3 20K(L) | 626 x 250 x 750 |
Galleon II-3/3 30KL | 815 x 300 x 1000 |
Galleon II-3/3 40KL | 815 x 300 x 1000 |
Long-run Model Net Weight (kgs)
Galleon II-3/3 10K(L) | 28 |
---|---|
Galleon II-3/3 15K(L) | 43 |
Galleon II-3/3 20K(L) | 43 |
Galleon II-3/3 30KL | 60 |
Galleon II-3/3 40KL | 61 |
MANAGEMENT
Optional SNMP
Galleon II-3/3 10K(L) | Power management from SNMP manager and web browser |
---|---|
Galleon II-3/3 15K(L) | Power management from SNMP manager and web browser |
Galleon II-3/3 20K(L) | Power management from SNMP manager and web browser |
Galleon II-3/3 30KL | Power management from SNMP manager and web browser |
Galleon II-3/3 40KL | Power management from SNMP manager and web browser |
Smart RS-232 / USB
Galleon II-3/3 10K(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
---|---|
Galleon II-3/3 15K(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon II-3/3 20K(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon II-3/3 30KL | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon II-3/3 40KL | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
![]() |
Brochure | Galleon II 3P/3P 10K-40K UL-Brochure |
![]() |
Manual | GalleonII3P3P10K-40KUL-manual |
Uncategorized Galleon II 3P/3P 10K-40K UL 3-phase in / 3-phase out
Related Products
We have received your membership application and will reply as soon as within 24 hours, before that, please browse our website, thank you.