- Select Capacity
- iMaster Solar Pump Inverter
- Select Capacity
- iMaster Solar Pump Inverter
337
iMaster
Solar Pump Inverter
The iMaster Solar Pump Inverter delivers efficient and reliable solar water pumping with a power conversion efficiency exceeding 99%, adapting seamlessly to changing weather conditions. It operates dependably in harsh environments, including depths reaching 200 meters. Moreover, an optional kit enables automatic switching between solar and grid power to maintain a continuous water supply.
It supports multiple motor control techniques, torque boost, and slip compensation for rapid response. Key features include accurate speed control, a wide voltage input range (200V-440V), conformal coating for environmental protection, RS-485 MODBUS communication, and compatibility with an external keypad.
Main Features
- The integrated maximum power point tracking (MPPT) algorithm guarantees that the solar power tracking efficiency exceeds 99%, thereby optimizing the performance of solar power conversion.
- Adjusts to variations in weather conditions, thereby preventing system shutdowns commonly experienced by traditional pumps during abrupt overcast periods.
- Strong anti-interference capabilities to reliably operate even at a well depth of 200 meters.
- Suitable for areas with inadequate power supply and various harsh environments.
- With an external switching kit, the inverter can automatically switch between PV input and grid input, thereby fulfilling the continuous water supply demand for 24 hours per day.
- Designed to control asynchronous AC induction motors.
- V/F Control, Sensor-less Vector Control (SVC), and Feedback Vector Control (FVC) are selectable.
- Automatic torque increase and slip adjustment.
- Rapid acceleration and deceleration capabilities.
- Delivers 150% torque at 0.5Hz.
- Offers accurate speed control within 0.5%.
- Supports a wide input voltage range from 200V to 440V.
- Features conformal coating for durability in harsh conditions.
- Includes built-in RS-485 MODBUS communication.
- Comes with a standard potentiometer and supports an external keypad.
| MODEL | iMaster Solar Pump Inverter | |
| CAPACITY | 0.75-37KW | |
| INPUT | ||
| Frequency Range | ±5% (47.5 ~ 63Hz) | |
| Input Voltage | 450VDC for 1PH | |
| Rated Frequency | 50/60 Hz | |
| OUTPUT | ||
| AC Voltage Regulation (Batt. Mode) | 0 ~ Input Voltage | |
| Surge Power | 0.1 ~ 500Hz | |
| Efficiency (Peak) | Please refer to Rated Parameter table | |
| Transfer Time | Please refer to Rated Parameter table | |
| ENVIRONMENT | ||
| Noise Level | 50dBA max. | |
| Storage temperature | -20°C ~ 60°C | |
| Operation temperature | -10°C ~ 50°C (If temperarture is higher than 40°C, the output capacity will be derated 1% per 1°C increase) | |
| Storage humidity | <95%RH | |
| Operation humidity | <95%RH | |
| STANDARD | ||
| Safety | Standards:IEC 61800-5-1 | |
| BASIC PARAMETERS | ||
| V/F separation | V/F control: 0 ~ 500Hz | |
| Highest frequency | Vector control: 0 ~ 500Hz | |
| Carrier frequency | 0.8KHz ~ 8KHz;Adjusted automatically according to the load characteristics | |
| Input frequency resolution | Digital setting: 0.01Hz; Analog setting: max. × 0.025% | |
| Control mode | Open-loop vector control (SVC) ; V/F control | |
| Starting torque | 0.5Hz/150%(SVC) | |
| Adjustable speed ratio | 1:100(SVC) | |
| Speed control accuracy | ±0.5%(SVC) | |
| Overload capability | 150% of rated current: 60 seconds ; 170% of rated current: 12 seconds ; 190% of rated current: 1.5 seconds | |
| Torque boost | Auto torque boost; Range of manual torque boost 0.1%~30.0% | |
| V/F curve | Three types: Linear, Multi-point, square curve (1.2 power, 1.4 power, 1.6 power, 1.8 power, 2 power) | |
| Acceleration and deceleration time | Linear and S-curve acceleration and deceleration modes available. The range of acceleration and deceleration time is 0.0~6500.0s. | |
| DC braking | Braking frequency: 0.00Hz ~ Maximum frequency Braking time: 0.0s~36.0s Braking current value: 0.0%~100.0% | |
| JOG control | JOG frequency range: 0.00Hz ~ Maximum frequency (5Hz in default). JOG acceleration and deceleration time: 0.0s~6500.0s. | |
| Built-in PID | Simplify the establishment of a closed-loop control system | |
| Automatic voltage regulation (AVR) | Keep the output voltage in stable when the grid voltage fluctuates. | |
| Stall prevention from overvoltage and overcurrent | The current and voltage are limited automatically during operation to prevent frequent tripping due to over-current and over-voltage. | |
| Rapid current limit | Reduce the risk of over-current faults to keep VFD operated normally. | |
| Torque limit and control | Limit the torque automatically during operation to prevent frequent tripping due to over-current. | |
| Braking unit | Built-in braking unit for 22KW and below models | |
| DISPLAY BUTTONS | ||
| Protective function | Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under-voltage protection, overheat protection, overload protection and etc. | |
| Key lock and function selections | It allows users to partially or fully lock the keys or define operated range for partial keys to prevent misoperation | |
| Keypad | Standard keypad | |
| SPECIAL FEATURES | ||
| Deceleration to stop | In case of instantaneous power drop, the load feedback energy is used to compensate the voltage drop to maintain the inverter’s normal operation over that short period. | |
| Rapid current limit | Reduce the risk of over-current faults to keep VFD operated normally. | |
| Timer control | Setting range: 0.0Min ~ 6500.0Min | |
| Communication | Modbus | |
| INPUT/OUTPUT | ||
| Command source | Operation panel, control terminal and serial communication port. | |
| Frequency source | Digital setting, Analog voltage setting, Analog current setting, Pulse setting and Serial port setting. | |
| Auxiliary frequency source | 5 options to provide flexible auxiliary frequency fine-tuning and frequency synthesis. | |
| Input terminals | 5 digital input terminals, one of which supports high-frequency pulse input up to 50kHz (only 4 digital input terminals available for MINI version) 1 analog input terminal supporting 0 ~ 10V voltage input or 0 ~ 20mA current input 1 rotary potentiometer analog input | |
| Output terminals | 1 high-speed pulse output terminal supporting 50kHz step-wave signal output 1 relay output terminal 1 analog output terminal supporting 0~20mA current output or 0~10V voltage output | |
General
CAPACITY
| iMaster Solar Pump Inverter | 0.75-37KW |
|---|
INPUT
Frequency Range
| iMaster Solar Pump Inverter | ±5% (47.5 ~ 63Hz) |
|---|
Input Voltage
| iMaster Solar Pump Inverter | 450VDC for 1PH |
|---|
Rated Frequency
| iMaster Solar Pump Inverter | 50/60 Hz |
|---|
OUTPUT
AC Voltage Regulation (Batt. Mode)
| iMaster Solar Pump Inverter | 0 ~ Input Voltage |
|---|
Surge Power
| iMaster Solar Pump Inverter | 0.1 ~ 500Hz |
|---|
Efficiency (Peak)
| iMaster Solar Pump Inverter | Please refer to Rated Parameter table |
|---|
Transfer Time
| iMaster Solar Pump Inverter | Please refer to Rated Parameter table |
|---|
ENVIRONMENT
Noise Level
| iMaster Solar Pump Inverter | 50dBA max. |
|---|
Storage temperature
| iMaster Solar Pump Inverter | -20°C ~ 60°C |
|---|
Operation temperature
| iMaster Solar Pump Inverter | -10°C ~ 50°C (If temperarture is higher than 40°C, the output capacity will be derated 1% per 1°C increase) |
|---|
Storage humidity
| iMaster Solar Pump Inverter | <95%RH |
|---|
Operation humidity
| iMaster Solar Pump Inverter | <95%RH |
|---|
STANDARD
Safety
| iMaster Solar Pump Inverter | Standards:IEC 61800-5-1 |
|---|
BASIC PARAMETERS
V/F separation
| iMaster Solar Pump Inverter | V/F control: 0 ~ 500Hz |
|---|
Highest frequency
| iMaster Solar Pump Inverter | Vector control: 0 ~ 500Hz |
|---|
Carrier frequency
| iMaster Solar Pump Inverter | 0.8KHz ~ 8KHz;Adjusted automatically according to the load characteristics |
|---|
Input frequency resolution
| iMaster Solar Pump Inverter | Digital setting: 0.01Hz; Analog setting: max. × 0.025% |
|---|
Control mode
| iMaster Solar Pump Inverter | Open-loop vector control (SVC) ; V/F control |
|---|
Starting torque
| iMaster Solar Pump Inverter | 0.5Hz/150%(SVC) |
|---|
Adjustable speed ratio
| iMaster Solar Pump Inverter | 1:100(SVC) |
|---|
Speed control accuracy
| iMaster Solar Pump Inverter | ±0.5%(SVC) |
|---|
Overload capability
| iMaster Solar Pump Inverter | 150% of rated current: 60 seconds ; 170% of rated current: 12 seconds ; 190% of rated current: 1.5 seconds |
|---|
Torque boost
| iMaster Solar Pump Inverter | Auto torque boost; Range of manual torque boost 0.1%~30.0% |
|---|
V/F curve
| iMaster Solar Pump Inverter | Three types: Linear, Multi-point, square curve (1.2 power, 1.4 power, 1.6 power, 1.8 power, 2 power) |
|---|
Acceleration and deceleration time
| iMaster Solar Pump Inverter | Linear and S-curve acceleration and deceleration modes available. The range of acceleration and deceleration time is 0.0~6500.0s. |
|---|
DC braking
| iMaster Solar Pump Inverter | Braking frequency: 0.00Hz ~ Maximum frequency Braking time: 0.0s~36.0s Braking current value: 0.0%~100.0% |
|---|
JOG control
| iMaster Solar Pump Inverter | JOG frequency range: 0.00Hz ~ Maximum frequency (5Hz in default). JOG acceleration and deceleration time: 0.0s~6500.0s. |
|---|
Built-in PID
| iMaster Solar Pump Inverter | Simplify the establishment of a closed-loop control system |
|---|
Automatic voltage regulation (AVR)
| iMaster Solar Pump Inverter | Keep the output voltage in stable when the grid voltage fluctuates. |
|---|
Stall prevention from overvoltage and overcurrent
| iMaster Solar Pump Inverter | The current and voltage are limited automatically during operation to prevent frequent tripping due to over-current and over-voltage. |
|---|
Rapid current limit
| iMaster Solar Pump Inverter | Reduce the risk of over-current faults to keep VFD operated normally. |
|---|
Torque limit and control
| iMaster Solar Pump Inverter | Limit the torque automatically during operation to prevent frequent tripping due to over-current. |
|---|
Braking unit
| iMaster Solar Pump Inverter | Built-in braking unit for 22KW and below models |
|---|
DISPLAY BUTTONS
Protective function
| iMaster Solar Pump Inverter | Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under-voltage protection, overheat protection, overload protection and etc. |
|---|
Key lock and function selections
| iMaster Solar Pump Inverter | It allows users to partially or fully lock the keys or define operated range for partial keys to prevent misoperation |
|---|
Keypad
| iMaster Solar Pump Inverter | Standard keypad |
|---|
SPECIAL FEATURES
Deceleration to stop
| iMaster Solar Pump Inverter | In case of instantaneous power drop, the load feedback energy is used to compensate the voltage drop to maintain the inverter’s normal operation over that short period. |
|---|
Rapid current limit
| iMaster Solar Pump Inverter | Reduce the risk of over-current faults to keep VFD operated normally. |
|---|
Timer control
| iMaster Solar Pump Inverter | Setting range: 0.0Min ~ 6500.0Min |
|---|
Communication
| iMaster Solar Pump Inverter | Modbus |
|---|
INPUT/OUTPUT
Command source
| iMaster Solar Pump Inverter | Operation panel, control terminal and serial communication port. |
|---|
Frequency source
| iMaster Solar Pump Inverter | Digital setting, Analog voltage setting, Analog current setting, Pulse setting and Serial port setting. |
|---|
Auxiliary frequency source
| iMaster Solar Pump Inverter | 5 options to provide flexible auxiliary frequency fine-tuning and frequency synthesis. |
|---|
Input terminals
| iMaster Solar Pump Inverter | 5 digital input terminals, one of which supports high-frequency pulse input up to 50kHz (only 4 digital input terminals available for MINI version) 1 analog input terminal supporting 0 ~ 10V voltage input or 0 ~ 20mA current input 1 rotary potentiometer analog input |
|---|
Output terminals
| iMaster Solar Pump Inverter | 1 high-speed pulse output terminal supporting 50kHz step-wave signal output 1 relay output terminal 1 analog output terminal supporting 0~20mA current output or 0~10V voltage output |
|---|
| Brochure | Brochure | |
| Manual | iMASTER |
VFD iMaster Solar Pump Inverter
We have received your membership application and will reply as soon as within 24 hours, before that, please browse our website, thank you.