Variable Frequency Drive
Variable Frequency Drive
Astro variable frequency drive is suitable for a variety of industrial applications. It is well applicable in all electrical, industrial equipment built with motors, like manufacturing equipment, compressor, elevator, etc. Its reliable SVC vector control and stable operation speed can optimize motor performance and extend its lifecycle, also saving your cost. The Astro variable frequency drive features a faster acceleration/deceleration, faster reacting to load change, and proactive responding while power shedding. In addition, Astro is equipped with a large silent fan, which is conducive to the rapid dissipation of heat; its simplified wiring method and parameter setting are easy to use.
Main Features
- Adjustable V/F curve and SVC vector control
- Automatic torque boost and slip compensation
- Fast acceleration and deceleration performance
- 150% torque at 0.5Hz
- Provide precise speed control 0.5%
- Acceptable wide input voltage from 380 (-15%) to 440V (10%)
- Thickened coating to withstand the harsh environment
- Built-in RS-485 MODBUS communication
- In-Built dynamic braking unit
- Simplified parameter setting for easy startup
- Standard potentiometer and support external keypad
- Flexible programmable I/O connection
- Control motor to deceleration to stop while sudden power failure to prevent damage
| MODEL | Variable Frequency Drive | |
| CAPACITY | 1.5-60 | |
| INPUT | ||
| Frequency Range | ±5% (47.5 ~ 63Hz) | |
| Input Voltage | AC,1PH,220V(-15%)~240V(+10%) AC,3PH,380V(-15%)~440V(+10%) | |
| Rated Frequency | 50/60 Hz | |
| OUTPUT | ||
| AC Voltage Regulation (Batt. Mode) | 0 ~ Input Voltage | |
| Surge Power | 0.1 ~ 500Hz | |
| Efficiency (Peak) | Please refer to Rated Parameter table | |
| Transfer Time | Please refer to Rated Parameter table | |
| ENVIRONMENT | ||
| Noise Level | 50dBA max. | |
| Storage temperature | -20°C ~ 60°C | |
| Operation temperature | -10°C ~ 50°C (If temperarture is higher than 40°C, the output capacity will be derated 1% per 1°C increase) | |
| Storage humidity | <90%RH | |
| Operation humidity | <90%RH | |
| STANDARD | ||
| Safety | Standards:IEC 61800-5-1 | |
| EMC | Standards:IEC 61800-3, C3 | |
| BASIC PARAMETERS | ||
| V/F separation | Full separation, Half separation | |
| Highest frequency | <0.75-3.7K> Vector control: 0~500Hz ;V/F control:0~500Hz <5.5-22K> Vector control: 0~320Hz;V/F control:0~500Hz | |
| Carrier frequency | 0.8kHz~8kHz (Support up to 16KHz carrier frequency) Adjusted automatically according to the load characteristics. | |
| Input frequency resolution | Digital setting: 0.01Hz Analog setting: max. × 0.025% | |
| Control mode | <0.75-3.7K>Open-loop vector control (SVC), V/F control<5.5-22K>Close-loop vector control (FVC), Open-loop vector control (SVC), V/F control | |
| Starting torque | <0.75-3.7K> 0.5Hz/150% (SVC); <5.5-22K> 0.5Hz/150% (SVC), 0Hz / 180% (FVC) | |
| Adjustable speed ratio | <0.75-3.7K> 1:100 (SVC); <5.5-22K> 1:100 (SVC),1:1000 (FVC) | |
| Speed control accuracy | <0.75-3.7K> ±0.5% (SVC); <5.5-22K> ±0.5% (SVC), ±0.02% (FVC) | |
| Overload capability | <0.75-3.7K> 150% of rated current: 60 seconds, 170% of rated current: 12 seconds, 190% of rated current: 1.5 seconds; <5.5-22K> 150% of rated current: 60 seconds,220% of rated current: 1 second | |
| Torque boost | Auto torque boost; Range of manual torque boost 0.1%~30.0% | |
| V/F curve | Three types: Linear, Multi-point, square curve (1.2 power, 1.4 power, 1.6 power, 1.8 power, 2 power) | |
| Acceleration and deceleration time | Linear and S-curve acceleration and deceleration modes available. The range of acceleration and deceleration time is 0.0~6500.0s. | |
| DC braking | Braking frequency: 0.00Hz ~ Maximum frequency Braking time: 0.0s~36.0s Braking current value: 0.0%~100.0% | |
| JOG control | JOG frequency range: 0.00Hz ~ Maximum frequency (5Hz in default). JOG acceleration and deceleration time: 0.0s~6500.0s. | |
| Built-in PID | Simplify the establishment of a closed-loop control system | |
| Automatic voltage regulation (AVR) | Keep the output voltage in stable when the grid voltage fluctuates. | |
| Stall prevention from overvoltage and overcurrent | The current and voltage are limited automatically during operation to prevent frequent tripping due to over-current and over-voltage. | |
| Rapid current limit | Reduce the risk of over-current faults to keep VFD operated normally. | |
| Torque limit and control | Limit the torque automatically during operation to prevent frequent tripping due to over-current. | |
| Braking unit | Built-in braking unit for 22KW and below models | |
| DISPLAY BUTTONS | ||
| LED display | Display parameters | |
| Protective function | Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under-voltage protection, overheat protection, overload protection and etc | |
| Key lock and function selections | It allows users to partially or fully lock the keys or define operated range for partial keys to prevent misoperation | |
| Keypad | 0.75K-3.7K model: standard keypad (Optional detachable keypad can be purchased seperately); 5.5K-22K model: standard detachable keypad | |
| Copy parameters (Only for 5.5-22K model) | Parameters can be copied through the standard external keyboard | |
| SPECIAL FEATURES | ||
| Deceleration to stop | In case of instantaneous power drop, the load feedback energy is used to compensate the voltage drop to maintain the inverter’s normal operation over that short period. | |
| Rapid current limit | Reduce the risk of over-current faults to keep VFD operated normally. | |
| Timer control | Setting range: 0.0Min ~ 6500.0Min | |
| Communication | <0.75-3.7K> Modbus; <5.5-22K> Modbus、CANLink、CANOpen、Profibus-DP、ProfiNET | |
| INPUT/OUTPUT | ||
| Command source | Operation panel, control terminal and serial communication port. | |
| Frequency source | <0.75-3.7K> Digital setting, Analog voltage setting, Analog current setting, Pulse setting and Serial port setting.<5.5-22K>Keyboard setting (saving/not saving when power-off), analog voltage setting, analog current setting, pulse setting, serial port setting, panel encoder setting, multi-speed running setting, simple PLC setting, PID setting, analog A13 setting (key knob).It can be switched in multiple ways. | |
| Auxiliary frequency source | <0.75-3.7K> 5 options to provide flexible auxiliary frequency fine-tuning and frequency synthesis. <5.5-22K>10 options to provide flexible auxiliary frequency fine-tuning and frequency synthesis. | |
| Input terminals | <0.75-3.7K> 4 digital input terminals, one of which supports high-frequency pulse input up to 50kHz, 1 analog input terminal supporting 0 ~ 10V voltage input or 0 ~ 20mA current input, 1 rotary potentiometer analog input; <5.5-22K>7 digital input terminals, one of which supports high-speed pulse input up to 100kHz, 2 analog input terminals, support 0~10V voltage input or 0~20mA current input, 1 rotary potentiometer analog input | |
| Output terminals | <0.75-3.7K>1 high-speed pulse output terminal supporting 50kHz step-wave signal output, 1 relay output terminal, 1 analog output terminal supporting 0~20mA current output or 0~10V voltage output<5.5-22K>1 high-speed pulse output terminal, support 100kHz square wave signal output, 1 digital output terminal, 2 relay output terminals, 2 analog output terminals, support 0~20mA current output or 0~10V voltage output | |
| INTERACE | ||
| Communication Port | RS-485 | |
General
CAPACITY
| Variable Frequency Drive | 1.5-60 |
|---|
INPUT
Frequency Range
| Variable Frequency Drive | ±5% (47.5 ~ 63Hz) |
|---|
Input Voltage
| Variable Frequency Drive | AC,1PH,220V(-15%)~240V(+10%) AC,3PH,380V(-15%)~440V(+10%) |
|---|
Rated Frequency
| Variable Frequency Drive | 50/60 Hz |
|---|
OUTPUT
AC Voltage Regulation (Batt. Mode)
| Variable Frequency Drive | 0 ~ Input Voltage |
|---|
Surge Power
| Variable Frequency Drive | 0.1 ~ 500Hz |
|---|
Efficiency (Peak)
| Variable Frequency Drive | Please refer to Rated Parameter table |
|---|
Transfer Time
| Variable Frequency Drive | Please refer to Rated Parameter table |
|---|
ENVIRONMENT
Noise Level
| Variable Frequency Drive | 50dBA max. |
|---|
Storage temperature
| Variable Frequency Drive | -20°C ~ 60°C |
|---|
Operation temperature
| Variable Frequency Drive | -10°C ~ 50°C (If temperarture is higher than 40°C, the output capacity will be derated 1% per 1°C increase) |
|---|
Storage humidity
| Variable Frequency Drive | <90%RH |
|---|
Operation humidity
| Variable Frequency Drive | <90%RH |
|---|
STANDARD
Safety
| Variable Frequency Drive | Standards:IEC 61800-5-1 |
|---|
EMC
| Variable Frequency Drive | Standards:IEC 61800-3, C3 |
|---|
BASIC PARAMETERS
V/F separation
| Variable Frequency Drive | Full separation, Half separation |
|---|
Highest frequency
| Variable Frequency Drive | <0.75-3.7K> Vector control: 0~500Hz ;V/F control:0~500Hz <5.5-22K> Vector control: 0~320Hz;V/F control:0~500Hz |
|---|
Carrier frequency
| Variable Frequency Drive | 0.8kHz~8kHz (Support up to 16KHz carrier frequency) Adjusted automatically according to the load characteristics. |
|---|
Input frequency resolution
| Variable Frequency Drive | Digital setting: 0.01Hz Analog setting: max. × 0.025% |
|---|
Control mode
| Variable Frequency Drive | <0.75-3.7K>Open-loop vector control (SVC), V/F control<5.5-22K>Close-loop vector control (FVC), Open-loop vector control (SVC), V/F control |
|---|
Starting torque
| Variable Frequency Drive | <0.75-3.7K> 0.5Hz/150% (SVC); <5.5-22K> 0.5Hz/150% (SVC), 0Hz / 180% (FVC) |
|---|
Adjustable speed ratio
| Variable Frequency Drive | <0.75-3.7K> 1:100 (SVC); <5.5-22K> 1:100 (SVC),1:1000 (FVC) |
|---|
Speed control accuracy
| Variable Frequency Drive | <0.75-3.7K> ±0.5% (SVC); <5.5-22K> ±0.5% (SVC), ±0.02% (FVC) |
|---|
Overload capability
| Variable Frequency Drive | <0.75-3.7K> 150% of rated current: 60 seconds, 170% of rated current: 12 seconds, 190% of rated current: 1.5 seconds; <5.5-22K> 150% of rated current: 60 seconds,220% of rated current: 1 second |
|---|
Torque boost
| Variable Frequency Drive | Auto torque boost; Range of manual torque boost 0.1%~30.0% |
|---|
V/F curve
| Variable Frequency Drive | Three types: Linear, Multi-point, square curve (1.2 power, 1.4 power, 1.6 power, 1.8 power, 2 power) |
|---|
Acceleration and deceleration time
| Variable Frequency Drive | Linear and S-curve acceleration and deceleration modes available. The range of acceleration and deceleration time is 0.0~6500.0s. |
|---|
DC braking
| Variable Frequency Drive | Braking frequency: 0.00Hz ~ Maximum frequency Braking time: 0.0s~36.0s Braking current value: 0.0%~100.0% |
|---|
JOG control
| Variable Frequency Drive | JOG frequency range: 0.00Hz ~ Maximum frequency (5Hz in default). JOG acceleration and deceleration time: 0.0s~6500.0s. |
|---|
Built-in PID
| Variable Frequency Drive | Simplify the establishment of a closed-loop control system |
|---|
Automatic voltage regulation (AVR)
| Variable Frequency Drive | Keep the output voltage in stable when the grid voltage fluctuates. |
|---|
Stall prevention from overvoltage and overcurrent
| Variable Frequency Drive | The current and voltage are limited automatically during operation to prevent frequent tripping due to over-current and over-voltage. |
|---|
Rapid current limit
| Variable Frequency Drive | Reduce the risk of over-current faults to keep VFD operated normally. |
|---|
Torque limit and control
| Variable Frequency Drive | Limit the torque automatically during operation to prevent frequent tripping due to over-current. |
|---|
Braking unit
| Variable Frequency Drive | Built-in braking unit for 22KW and below models |
|---|
DISPLAY BUTTONS
LED display
| Variable Frequency Drive | Display parameters |
|---|
Protective function
| Variable Frequency Drive | Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under-voltage protection, overheat protection, overload protection and etc |
|---|
Key lock and function selections
| Variable Frequency Drive | It allows users to partially or fully lock the keys or define operated range for partial keys to prevent misoperation |
|---|
Keypad
| Variable Frequency Drive | 0.75K-3.7K model: standard keypad (Optional detachable keypad can be purchased seperately); 5.5K-22K model: standard detachable keypad |
|---|
Copy parameters
(Only for 5.5-22K model)
| Variable Frequency Drive | Parameters can be copied through the standard external keyboard |
|---|
SPECIAL FEATURES
Deceleration to stop
| Variable Frequency Drive | In case of instantaneous power drop, the load feedback energy is used to compensate the voltage drop to maintain the inverter’s normal operation over that short period. |
|---|
Rapid current limit
| Variable Frequency Drive | Reduce the risk of over-current faults to keep VFD operated normally. |
|---|
Timer control
| Variable Frequency Drive | Setting range: 0.0Min ~ 6500.0Min |
|---|
Communication
| Variable Frequency Drive | <0.75-3.7K> Modbus; <5.5-22K> Modbus、CANLink、CANOpen、Profibus-DP、ProfiNET |
|---|
INPUT/OUTPUT
Command source
| Variable Frequency Drive | Operation panel, control terminal and serial communication port. |
|---|
Frequency source
| Variable Frequency Drive | <0.75-3.7K> Digital setting, Analog voltage setting, Analog current setting, Pulse setting and Serial port setting.<5.5-22K>Keyboard setting (saving/not saving when power-off), analog voltage setting, analog current setting, pulse setting, serial port setting, panel encoder setting, multi-speed running setting, simple PLC setting, PID setting, analog A13 setting (key knob).It can be switched in multiple ways. |
|---|
Auxiliary frequency source
| Variable Frequency Drive | <0.75-3.7K> 5 options to provide flexible auxiliary frequency fine-tuning and frequency synthesis. <5.5-22K>10 options to provide flexible auxiliary frequency fine-tuning and frequency synthesis. |
|---|
Input terminals
| Variable Frequency Drive | <0.75-3.7K> 4 digital input terminals, one of which supports high-frequency pulse input up to 50kHz, 1 analog input terminal supporting 0 ~ 10V voltage input or 0 ~ 20mA current input, 1 rotary potentiometer analog input; <5.5-22K>7 digital input terminals, one of which supports high-speed pulse input up to 100kHz, 2 analog input terminals, support 0~10V voltage input or 0~20mA current input, 1 rotary potentiometer analog input |
|---|
Output terminals
| Variable Frequency Drive | <0.75-3.7K>1 high-speed pulse output terminal supporting 50kHz step-wave signal output, 1 relay output terminal, 1 analog output terminal supporting 0~20mA current output or 0~10V voltage output<5.5-22K>1 high-speed pulse output terminal, support 100kHz square wave signal output, 1 digital output terminal, 2 relay output terminals, 2 analog output terminals, support 0~20mA current output or 0~10V voltage output |
|---|
INTERACE
Communication Port
| Variable Frequency Drive | RS-485 |
|---|
| Brochure | VFD_Brochure | |
| Manual | VFD 0.75-3.7K_Manual | |
| Manual | VFD 5.5-22K_Manual |