140
Solar Online UPS 1KVA-3KVA
Online UPS integrated with a solar charger
The Solar Online UPS 1KVA-3KVA comes equipped with an integrated MPPT solar charger and smart SBU (Solar, Battery, Utility) priority management. This allows for direct connection of solar panels to the UPS, making utility power just one of several power sources. When grid power is unavailable, the UPS will use solar energy to charge the battery. With the SBU priority smart management feature, you can customize the priority of the UPS’s energy sources according to your preferences. Additionally, the charger capacity can be increased up to 6A to reduce charging time.
Main Features
- SBU (Solar, Battery, Utility) Priority Intelligent Management
- Equipped with a built-in 1KW or 1.5KW MPPT solar charger
- Features true double-conversion technology
- Includes input power factor correction
- Supports a wide input voltage range (110V-280V)
- Offers converter mode functionality
- Energy-saving ECO mode available
- Compatible with generators
- An optional isolation transformer provides full isolation and effective common-mode noise rejection
- Comprehensive display enables easy monitoring and convenient access to UPS and solar energy status
| MODEL | SOLAR UPS 1KW | SOLAR UPS 2KW | SOLAR UPS 3KW | |
| CAPACITY | 1000 VA / 800 W | 2000 VA / 1600 W | 3000 VA / 2400 W | |
| INPUT | ||||
| Voltage | 220/230/240VAC | 220/230/240VAC | 220/230/240VAC | |
| Voltage Range | 110-280 VAC | 110-280 VAC | 110-280 VAC | |
| Frequency Range | 40 Hz-70 Hz | 40 Hz-70 Hz | 40 Hz-70 Hz | |
| Power Factor | ≧ 0.95 @ Nominal Voltage (100% Load) | ≧ 0.95 @ Nominal Voltage (100% Load) | ≧ 0.95 @ Nominal Voltage (100% Load) | |
| OUTPUT | ||||
| AC Voltage Regulation (Batt. Mode) | 220/230/240VAC | 220/230/240VAC | 220/230/240VAC | |
| Frequency Range (Batt. Mode) | 50 Hz or 60Hz ± 0.1 Hz | 50 Hz or 60Hz ± 0.1 Hz | 50 Hz or 60Hz ± 0.1 Hz | |
| Transfer Time | AC Mode to Batt. Mode | Zero | Zero | Zero |
| Transfer Time | Inverter to Bypass | 4 ms (Typical) | 4 ms (Typical) | 4 ms (Typical) |
| Waveform | Pure Sinewave | Pure Sinewave | Pure Sinewave | |
| Harmonic Distortion | ≦ 3% THD (Linear Load) ; ≦ 6 % THD (Non-linear Load) | ≦ 3% THD (Linear Load) ; ≦ 6 % THD (Non-linear Load) | ≦ 3% THD (Linear Load) ; ≦ 6 % THD (Non-linear Load) | |
| Frequency Range (Synchronized Range) | 47~ 53 Hz or 57 ~ 63 Hz | 47~ 53 Hz or 57 ~ 63 Hz | 47~ 53 Hz or 57 ~ 63 Hz | |
| EFFICIENCY | ||||
| Battery Mode | 0.83 | 0.87 | 0.88 | |
| Line Mode | 0.88 | 0.89 | 0.9 | |
| BATTERY | ||||
| Battery Voltage | 36Vdc | 72Vdc | 72Vdc | |
| Charging Voltage | 41.0VDC ± 1% | 82.1VDC ± 1% | 82.1VDC ± 1% | |
| Charging Current (max.) | 1/2/4/6A(Default), adjustable by internal jumper | 1/2/4/6A(Default), adjustable by internal jumper | 1/2/4/6A(Default), adjustable by internal jumper | |
| SOLAR CHARGER & AC CHARGER | ||||
| Solar Charger Type | MPPT | MPPT | MPPT | |
| Maximum PV Array Open Circuit Voltage | 145 VDC | 145 VDC | 145 VDC | |
| Maximum PV Array Power | 1000W | 1500W | 1500W | |
| MPPT Range @ Operating Voltage | 40 VDC - 115 VDC | 90 VDC - 115 VDC | 90 VDC - 115 VDC | |
| Maximum AC Charge Current | 20A | 20A | 20A | |
| Maximum Charging Current | 15A | 15A | 15A | |
| PHYSICAL | ||||
| Dimension, D X W X H (mm) | 282 x 145 x 332 | 400 x 145 x 332 | 400 x145x332 | |
| Net Weight (kgs) | 7.6 | 12 | 12.3 | |
| Communication Port | RS232 & USB | RS232 & USB | RS232 & USB | |
| OPERATING ENVIRONMENT | ||||
| Operating Humidity | 20-90 % RH @ 0- 50°C (non-condensing) | 20-90 % RH @ 0- 50°C (non-condensing) | 20-90 % RH @ 0- 50°C (non-condensing) | |
General
CAPACITY
| SOLAR UPS 1KW | 1000 VA / 800 W |
|---|---|
| SOLAR UPS 2KW | 2000 VA / 1600 W |
| SOLAR UPS 3KW | 3000 VA / 2400 W |
INPUT
Voltage
| SOLAR UPS 1KW | 220/230/240VAC |
|---|---|
| SOLAR UPS 2KW | 220/230/240VAC |
| SOLAR UPS 3KW | 220/230/240VAC |
Voltage Range
| SOLAR UPS 1KW | 110-280 VAC |
|---|---|
| SOLAR UPS 2KW | 110-280 VAC |
| SOLAR UPS 3KW | 110-280 VAC |
Frequency Range
| SOLAR UPS 1KW | 40 Hz-70 Hz |
|---|---|
| SOLAR UPS 2KW | 40 Hz-70 Hz |
| SOLAR UPS 3KW | 40 Hz-70 Hz |
Power Factor
| SOLAR UPS 1KW | ≧ 0.95 @ Nominal Voltage (100% Load) |
|---|---|
| SOLAR UPS 2KW | ≧ 0.95 @ Nominal Voltage (100% Load) |
| SOLAR UPS 3KW | ≧ 0.95 @ Nominal Voltage (100% Load) |
OUTPUT
AC Voltage Regulation (Batt. Mode)
| SOLAR UPS 1KW | 220/230/240VAC |
|---|---|
| SOLAR UPS 2KW | 220/230/240VAC |
| SOLAR UPS 3KW | 220/230/240VAC |
Frequency Range (Batt. Mode)
| SOLAR UPS 1KW | 50 Hz or 60Hz ± 0.1 Hz |
|---|---|
| SOLAR UPS 2KW | 50 Hz or 60Hz ± 0.1 Hz |
| SOLAR UPS 3KW | 50 Hz or 60Hz ± 0.1 Hz |
Transfer Time AC Mode to Batt. Mode
| SOLAR UPS 1KW | Zero |
|---|---|
| SOLAR UPS 2KW | Zero |
| SOLAR UPS 3KW | Zero |
Transfer Time Inverter to Bypass
| SOLAR UPS 1KW | 4 ms (Typical) |
|---|---|
| SOLAR UPS 2KW | 4 ms (Typical) |
| SOLAR UPS 3KW | 4 ms (Typical) |
Waveform
| SOLAR UPS 1KW | Pure Sinewave |
|---|---|
| SOLAR UPS 2KW | Pure Sinewave |
| SOLAR UPS 3KW | Pure Sinewave |
Harmonic Distortion
| SOLAR UPS 1KW | ≦ 3% THD (Linear Load) ; ≦ 6 % THD (Non-linear Load) |
|---|---|
| SOLAR UPS 2KW | ≦ 3% THD (Linear Load) ; ≦ 6 % THD (Non-linear Load) |
| SOLAR UPS 3KW | ≦ 3% THD (Linear Load) ; ≦ 6 % THD (Non-linear Load) |
Frequency Range (Synchronized Range)
| SOLAR UPS 1KW | 47~ 53 Hz or 57 ~ 63 Hz |
|---|---|
| SOLAR UPS 2KW | 47~ 53 Hz or 57 ~ 63 Hz |
| SOLAR UPS 3KW | 47~ 53 Hz or 57 ~ 63 Hz |
EFFICIENCY
Battery Mode
| SOLAR UPS 1KW | 0.83 |
|---|---|
| SOLAR UPS 2KW | 0.87 |
| SOLAR UPS 3KW | 0.88 |
Line Mode
| SOLAR UPS 1KW | 0.88 |
|---|---|
| SOLAR UPS 2KW | 0.89 |
| SOLAR UPS 3KW | 0.9 |
BATTERY
Battery Voltage
| SOLAR UPS 1KW | 36Vdc |
|---|---|
| SOLAR UPS 2KW | 72Vdc |
| SOLAR UPS 3KW | 72Vdc |
Charging Voltage
| SOLAR UPS 1KW | 41.0VDC ± 1% |
|---|---|
| SOLAR UPS 2KW | 82.1VDC ± 1% |
| SOLAR UPS 3KW | 82.1VDC ± 1% |
Charging Current (max.)
| SOLAR UPS 1KW | 1/2/4/6A(Default), adjustable by internal jumper |
|---|---|
| SOLAR UPS 2KW | 1/2/4/6A(Default), adjustable by internal jumper |
| SOLAR UPS 3KW | 1/2/4/6A(Default), adjustable by internal jumper |
SOLAR CHARGER & AC CHARGER
Solar Charger Type
| SOLAR UPS 1KW | MPPT |
|---|---|
| SOLAR UPS 2KW | MPPT |
| SOLAR UPS 3KW | MPPT |
Maximum PV Array Open Circuit Voltage
| SOLAR UPS 1KW | 145 VDC |
|---|---|
| SOLAR UPS 2KW | 145 VDC |
| SOLAR UPS 3KW | 145 VDC |
Maximum PV Array Power
| SOLAR UPS 1KW | 1000W |
|---|---|
| SOLAR UPS 2KW | 1500W |
| SOLAR UPS 3KW | 1500W |
MPPT Range @ Operating Voltage
| SOLAR UPS 1KW | 40 VDC - 115 VDC |
|---|---|
| SOLAR UPS 2KW | 90 VDC - 115 VDC |
| SOLAR UPS 3KW | 90 VDC - 115 VDC |
Maximum AC Charge Current
| SOLAR UPS 1KW | 20A |
|---|---|
| SOLAR UPS 2KW | 20A |
| SOLAR UPS 3KW | 20A |
Maximum Charging Current
| SOLAR UPS 1KW | 15A |
|---|---|
| SOLAR UPS 2KW | 15A |
| SOLAR UPS 3KW | 15A |
PHYSICAL
Dimension, D X W X H (mm)
| SOLAR UPS 1KW | 282 x 145 x 332 |
|---|---|
| SOLAR UPS 2KW | 400 x 145 x 332 |
| SOLAR UPS 3KW | 400 x145x332 |
Net Weight (kgs)
| SOLAR UPS 1KW | 7.6 |
|---|---|
| SOLAR UPS 2KW | 12 |
| SOLAR UPS 3KW | 12.3 |
Communication Port
| SOLAR UPS 1KW | RS232 & USB |
|---|---|
| SOLAR UPS 2KW | RS232 & USB |
| SOLAR UPS 3KW | RS232 & USB |
OPERATING ENVIRONMENT
Operating Humidity
| SOLAR UPS 1KW | 20-90 % RH @ 0- 50°C (non-condensing) |
|---|---|
| SOLAR UPS 2KW | 20-90 % RH @ 0- 50°C (non-condensing) |
| SOLAR UPS 3KW | 20-90 % RH @ 0- 50°C (non-condensing) |
| Brochure | Solar Online UPS 1KVA-3KVA Brochure | |
| Manual | Solar Online UPS 1KVA-3KVA Manual |
Single phase - Online UPS Solar Online UPS 1KVA-3KVA Online UPS integrated with a solar charger
Related Products