41
Scudo 400VA-600VA
Generated sine wave output
This is a compact uninterruptible power supply designed for home and office devices. It features versatile display options and built-in output sockets for convenient use.
Main Features
- Compact design with local outlets for convenient use
- Superior microprocessor control ensures high reliability
- Automatic restart when AC power is restored
- Simulated sine wave output
- Cold start capability
- Easy installation and user-friendly operation
- Available in 400VA and 600VA standby UPS models
| MODEL | Scudo 400 | Scudo 600 | |
| CAPACITY | 400 VA / 200 W | 600 VA / 300 W | |
| INPUT | |||
| Voltage | 220/230/240 VAC | 220/230/240 VAC | |
| Voltage Range | 180-270 VAC | 180-270 VAC | |
| Frequency | 50 Hz | 50 Hz | |
| OUTPUT | |||
| Output Voltage | 220/230/240 VAC | 220/230/240 VAC | |
| Frequency Range (Batt. Mode) | 50 Hz ± 1 Hz | 50 Hz ± 1 Hz | |
| Waveform (Batt. Mode) | Simulated Sine Wave | Simulated Sine Wave | |
| Voltage Regulation (Batt. Mode) | ± 10% | ± 10% | |
| Transfer Time (Typical) | 2-6 ms | 2-6 ms | |
| BATTERY | |||
| Battery Type & Number | 12 V/4.5 AH x 1 | 12 V/5 AH x 1 | |
| Typical Charging Time | 8 hours recover to 90% capacity | 8 hours recover to 90% capacity | |
| INDICATORS | |||
| AC Mode | Green lighting | Green lighting | |
| Battery Mode | Green flashing every 10 seconds | Green flashing every 10 seconds | |
| Fault | Red lighting | Red lighting | |
| Low Battery | Green flashing every second and red lighting | Green flashing every second and red lighting | |
| ALARM | |||
| Battery Mode | Sounding every 10 seconds | Sounding every 10 seconds | |
| Low Battery | Sounding every second | Sounding every second | |
| Fault | Continuously sounding | Continuously sounding | |
| PHYSICAL | |||
| Dimension, D X W X H (mm) | 166 x 161 x 89.2 | 166 x 161 x 89.2 | |
| Net Weight (kgs) | 2.25 | 2.56 | |
| OPERATING ENVIRONMENT | |||
| Operating Humidity | 0~90% RH | 0~90% RH | |
| Operating Temperature | 0- 40°C (non-condensing) | 0- 40°C (non-condensing) | |
General
CAPACITY
| Scudo 400 | 400 VA / 200 W |
|---|---|
| Scudo 600 | 600 VA / 300 W |
INPUT
Voltage
| Scudo 400 | 220/230/240 VAC |
|---|---|
| Scudo 600 | 220/230/240 VAC |
Voltage Range
| Scudo 400 | 180-270 VAC |
|---|---|
| Scudo 600 | 180-270 VAC |
Frequency
| Scudo 400 | 50 Hz |
|---|---|
| Scudo 600 | 50 Hz |
OUTPUT
Output Voltage
| Scudo 400 | 220/230/240 VAC |
|---|---|
| Scudo 600 | 220/230/240 VAC |
Frequency Range (Batt. Mode)
| Scudo 400 | 50 Hz ± 1 Hz |
|---|---|
| Scudo 600 | 50 Hz ± 1 Hz |
Waveform (Batt. Mode)
| Scudo 400 | Simulated Sine Wave |
|---|---|
| Scudo 600 | Simulated Sine Wave |
Voltage Regulation (Batt. Mode)
| Scudo 400 | ± 10% |
|---|---|
| Scudo 600 | ± 10% |
Transfer Time (Typical)
| Scudo 400 | 2-6 ms |
|---|---|
| Scudo 600 | 2-6 ms |
BATTERY
Battery Type & Number
| Scudo 400 | 12 V/4.5 AH x 1 |
|---|---|
| Scudo 600 | 12 V/5 AH x 1 |
Typical Charging Time
| Scudo 400 | 8 hours recover to 90% capacity |
|---|---|
| Scudo 600 | 8 hours recover to 90% capacity |
INDICATORS
AC Mode
| Scudo 400 | Green lighting |
|---|---|
| Scudo 600 | Green lighting |
Battery Mode
| Scudo 400 | Green flashing every 10 seconds |
|---|---|
| Scudo 600 | Green flashing every 10 seconds |
Fault
| Scudo 400 | Red lighting |
|---|---|
| Scudo 600 | Red lighting |
Low Battery
| Scudo 400 | Green flashing every second and red lighting |
|---|---|
| Scudo 600 | Green flashing every second and red lighting |
ALARM
Battery Mode
| Scudo 400 | Sounding every 10 seconds |
|---|---|
| Scudo 600 | Sounding every 10 seconds |
Low Battery
| Scudo 400 | Sounding every second |
|---|---|
| Scudo 600 | Sounding every second |
Fault
| Scudo 400 | Continuously sounding |
|---|---|
| Scudo 600 | Continuously sounding |
PHYSICAL
Dimension, D X W X H (mm)
| Scudo 400 | 166 x 161 x 89.2 |
|---|---|
| Scudo 600 | 166 x 161 x 89.2 |
Net Weight (kgs)
| Scudo 400 | 2.25 |
|---|---|
| Scudo 600 | 2.56 |
OPERATING ENVIRONMENT
Operating Humidity
| Scudo 400 | 0~90% RH |
|---|---|
| Scudo 600 | 0~90% RH |
Operating Temperature
| Scudo 400 | 0- 40°C (non-condensing) |
|---|---|
| Scudo 600 | 0- 40°C (non-condensing) |
| Brochure | Scudo_Brochure | |
| Manual | Scudo_Manual |