- Select Capacity
- Outdoor 2000A / UPS-2000A
- Outdoor 2000E / UPS-2000E
- Select Capacity
- Outdoor 2000A / UPS-2000A
- Outdoor 2000E / UPS-2000E
7
Outdoor UPS
Outdoor UPS
Outdoor UPS is designed for extreme demanding environments where clean backup power is needed. Built-in with AVR function, it helps to maintain normal operation without transferring to battery mode during voltage surge or sag. It also offers battery temperature sensor connector to monitor connected battery temperature anytime. Equipped with dry contacts, outdoor UPS is able to provide programmable signals for event alarms. It’s perfect to use in security, communication, traffic and many other critical industrial environments.
Main Features
- • Provide continuous power to critical loads during blackout in rugged environment
- • Wide operating temperature range from -40°C to 80°C suits for outdoor applications
- • Built-in boost and buck AVR to regulate input voltage
- • Selectable transfer time for normal or generator modes
- • Provide RS-232, USB and SNMP intelligent port
- • Circuit breaker protection on AC input, AC output and external battery input
- • User-adjustable charging current
- • Adjustable input threshold voltage
- • Provide programmable signals for dry contacts
- • Battery compensation optimizes battery lifecycle
MODEL | Outdoor 2000A / UPS-2000A | Outdoor 2000E / UPS-2000E | |
Rated Power | 2000 VA / 1600 W | 2000 VA / 1600 W | |
INPUT | |||
Nominal Voltage | 120 VAC | 230/240 VAC | |
Acceptable Voltage Range | 88 ~152 VAC user programmable. Default: 100~130VAC | 176~300VAC user programmable. Default: 200~260VAC | |
Frequency Range | 60/50 Hz (Auto sensing) | 60/50 Hz (Auto sensing) | |
OUTPUT | |||
Transfer Time | Generator Mode (max.) | 25ms | 25ms |
Transfer Time | Normal Mode (max.) | 12ms | 12ms |
Waveform | Pure Sine Wave | Pure Sine Wave | |
Nominal Voltage | 120 VAC | 230/240 VAC | |
Efficiency | AVR Mode | 90% | 90% |
Efficiency | Battery Mode | 90% | 90% |
Efficiency | Line Mode | 95% | 95% |
Voltage Regulation (Batt. Mode) | 120 VAC ± 5% | 230/240 VAC ± 5% | |
Frequency | 50Hz/60Hz ± 0.1% | 50Hz/60Hz ± 0.1% | |
THD (Batt. Mode) | <3% @ Full resistive load | <3% @ Full resistive load | |
BATTERY | |||
Battery Type | AGM | AGM | |
Charging Current | 2A/4A/6A/8A/10A (Adjustable) | 2A/4A/6A/8A/10A (Adjustable) | |
Low DC Warning Voltage | 46VDC ± 0.4VDC @ no load | 46VDC ± 0.4VDC @ no load | |
Nominal DC Voltage | 48 VDC | 48 VDC | |
INDICATORS | |||
Battery Mode | Green LED flashing | Green LED flashing | |
Bypass Mode | Green LED on | Green LED on | |
Fault without Output | Red LED on | Red LED on | |
No Output | Green LED Off | Green LED Off | |
Warning with Output | Yellow LED on | Yellow LED on | |
ENVIRONMENT | |||
Operating Temperature | -40°C to 80°C | -40°C to 70°C | |
Humidity | 5% to 95% Relative Humidity(Non-condensing) | 5% to 95% Relative Humidity(Non-condensing) | |
Noise Level | < 48dB | < 48dB | |
PHYSICAL | |||
Dimension, D X W X H (mm) | 240 x400 x 133 | 240 x400 x 133 | |
Net Weight (kgs) | 13 | 13 | |
Type of Mechanical Protection | IP 20 | IP 20 | |
COMPLIANCE | |||
EMI Compliance | Class A FCC/CISPR [EN50091-2: 1995] | Class A FCC/CISPR [EN50091-2: 1995] | |
Surge Protection | IEEE/ANSI C.62.41 & 2KV, L-N | IEEE/ANSI C.62.41 & 2KV, L-N | |
MANAGEMENT | |||
Communication | USB, RS-232 and optional SNMP | USB, RS-232 and optional SNMP | |
Dry Contact Rating | 3A @ 125VAC | 3A @ 250VAC |
General
Rated Power
Outdoor 2000A / UPS-2000A | 2000 VA / 1600 W |
---|---|
Outdoor 2000E / UPS-2000E | 2000 VA / 1600 W |
INPUT
Nominal Voltage
Outdoor 2000A / UPS-2000A | 120 VAC |
---|---|
Outdoor 2000E / UPS-2000E | 230/240 VAC |
Acceptable Voltage Range
Outdoor 2000A / UPS-2000A | 88 ~152 VAC user programmable. Default: 100~130VAC |
---|---|
Outdoor 2000E / UPS-2000E | 176~300VAC user programmable. Default: 200~260VAC |
Frequency Range
Outdoor 2000A / UPS-2000A | 60/50 Hz (Auto sensing) |
---|---|
Outdoor 2000E / UPS-2000E | 60/50 Hz (Auto sensing) |
OUTPUT
Transfer Time Generator Mode (max.)
Outdoor 2000A / UPS-2000A | 25ms |
---|---|
Outdoor 2000E / UPS-2000E | 25ms |
Transfer Time Normal Mode (max.)
Outdoor 2000A / UPS-2000A | 12ms |
---|---|
Outdoor 2000E / UPS-2000E | 12ms |
Waveform
Outdoor 2000A / UPS-2000A | Pure Sine Wave |
---|---|
Outdoor 2000E / UPS-2000E | Pure Sine Wave |
Nominal Voltage
Outdoor 2000A / UPS-2000A | 120 VAC |
---|---|
Outdoor 2000E / UPS-2000E | 230/240 VAC |
Efficiency AVR Mode
Outdoor 2000A / UPS-2000A | 90% |
---|---|
Outdoor 2000E / UPS-2000E | 90% |
Efficiency Battery Mode
Outdoor 2000A / UPS-2000A | 90% |
---|---|
Outdoor 2000E / UPS-2000E | 90% |
Efficiency Line Mode
Outdoor 2000A / UPS-2000A | 95% |
---|---|
Outdoor 2000E / UPS-2000E | 95% |
Voltage Regulation (Batt. Mode)
Outdoor 2000A / UPS-2000A | 120 VAC ± 5% |
---|---|
Outdoor 2000E / UPS-2000E | 230/240 VAC ± 5% |
Frequency
Outdoor 2000A / UPS-2000A | 50Hz/60Hz ± 0.1% |
---|---|
Outdoor 2000E / UPS-2000E | 50Hz/60Hz ± 0.1% |
THD (Batt. Mode)
Outdoor 2000A / UPS-2000A | <3% @ Full resistive load |
---|---|
Outdoor 2000E / UPS-2000E | <3% @ Full resistive load |
BATTERY
Battery Type
Outdoor 2000A / UPS-2000A | AGM |
---|---|
Outdoor 2000E / UPS-2000E | AGM |
Charging Current
Outdoor 2000A / UPS-2000A | 2A/4A/6A/8A/10A (Adjustable) |
---|---|
Outdoor 2000E / UPS-2000E | 2A/4A/6A/8A/10A (Adjustable) |
Low DC Warning Voltage
Outdoor 2000A / UPS-2000A | 46VDC ± 0.4VDC @ no load |
---|---|
Outdoor 2000E / UPS-2000E | 46VDC ± 0.4VDC @ no load |
Nominal DC Voltage
Outdoor 2000A / UPS-2000A | 48 VDC |
---|---|
Outdoor 2000E / UPS-2000E | 48 VDC |
INDICATORS
Battery Mode
Outdoor 2000A / UPS-2000A | Green LED flashing |
---|---|
Outdoor 2000E / UPS-2000E | Green LED flashing |
Bypass Mode
Outdoor 2000A / UPS-2000A | Green LED on |
---|---|
Outdoor 2000E / UPS-2000E | Green LED on |
Fault without Output
Outdoor 2000A / UPS-2000A | Red LED on |
---|---|
Outdoor 2000E / UPS-2000E | Red LED on |
No Output
Outdoor 2000A / UPS-2000A | Green LED Off |
---|---|
Outdoor 2000E / UPS-2000E | Green LED Off |
Warning with Output
Outdoor 2000A / UPS-2000A | Yellow LED on |
---|---|
Outdoor 2000E / UPS-2000E | Yellow LED on |
ENVIRONMENT
Operating Temperature
Outdoor 2000A / UPS-2000A | -40°C to 80°C |
---|---|
Outdoor 2000E / UPS-2000E | -40°C to 70°C |
Humidity
Outdoor 2000A / UPS-2000A | 5% to 95% Relative Humidity(Non-condensing) |
---|---|
Outdoor 2000E / UPS-2000E | 5% to 95% Relative Humidity(Non-condensing) |
Noise Level
Outdoor 2000A / UPS-2000A | < 48dB |
---|---|
Outdoor 2000E / UPS-2000E | < 48dB |
PHYSICAL
Dimension, D X W X H (mm)
Outdoor 2000A / UPS-2000A | 240 x400 x 133 |
---|---|
Outdoor 2000E / UPS-2000E | 240 x400 x 133 |
Net Weight (kgs)
Outdoor 2000A / UPS-2000A | 13 |
---|---|
Outdoor 2000E / UPS-2000E | 13 |
Type of Mechanical Protection
Outdoor 2000A / UPS-2000A | IP 20 |
---|---|
Outdoor 2000E / UPS-2000E | IP 20 |
COMPLIANCE
EMI Compliance
Outdoor 2000A / UPS-2000A | Class A FCC/CISPR [EN50091-2: 1995] |
---|---|
Outdoor 2000E / UPS-2000E | Class A FCC/CISPR [EN50091-2: 1995] |
Surge Protection
Outdoor 2000A / UPS-2000A | IEEE/ANSI C.62.41 & 2KV, L-N |
---|---|
Outdoor 2000E / UPS-2000E | IEEE/ANSI C.62.41 & 2KV, L-N |
MANAGEMENT
Communication
Outdoor 2000A / UPS-2000A | USB, RS-232 and optional SNMP |
---|---|
Outdoor 2000E / UPS-2000E | USB, RS-232 and optional SNMP |
Dry Contact Rating
Outdoor 2000A / UPS-2000A | 3A @ 125VAC |
---|---|
Outdoor 2000E / UPS-2000E | 3A @ 250VAC |
Brochure | Outdoor UPS | |
Manual | Outdoor UPS Manual |
Line Interactive UPS Outdoor UPS Outdoor UPS
We have received your membership application and will reply as soon as within 24 hours, before that, please browse our website, thank you.