Outdoor UPS
Outdoor UPS
Outdoor UPS is designed for extreme demanding environments where clean backup power is needed. Built-in with AVR function, it helps to maintain normal operation without transferring to battery mode during voltage surge or sag. It also offers battery temperature sensor connector to monitor connected battery temperature anytime. Equipped with dry contacts, outdoor UPS is able to provide programmable signals for event alarms. It’s perfect to use in security, communication, traffic and many other critical industrial environments.
Main Features
  • Provide continuous power to critical loads during blackout in rugged environment
  • Wide operating temperature range from -40°C to 80°C suits for outdoor applications
  • Built-in boost and buck AVR to regulate input voltage
  • Selectable transfer time for normal or generator modes
  • Provide RS-232, USB and SNMP intelligent port
  • Circuit breaker protection on AC input, AC output and external battery input
  • User-adjustable charging current
  • Adjustable input threshold voltage
  • Provide programmable signals for dry contacts
  • Battery compensation optimizes battery lifecycle
General
Rated Power
Outdoor 2000A / UPS-2000A2000 VA / 1600 W
Outdoor 2000E / UPS-2000E2000 VA / 1600 W
INPUT
Nominal Voltage
Outdoor 2000A / UPS-2000A120 VAC
Outdoor 2000E / UPS-2000E230/240 VAC
Acceptable Voltage Range
Outdoor 2000A / UPS-2000A88 ~152 VAC user programmable. Default: 100~130VAC
Outdoor 2000E / UPS-2000E176~300VAC user programmable. Default: 200~260VAC
Frequency Range
Outdoor 2000A / UPS-2000A60/50 Hz (Auto sensing)
Outdoor 2000E / UPS-2000E60/50 Hz (Auto sensing)
OUTPUT
Transfer Time Generator Mode (max.)
Outdoor 2000A / UPS-2000A25ms
Outdoor 2000E / UPS-2000E25ms
Transfer Time Normal Mode (max.)
Outdoor 2000A / UPS-2000A12ms
Outdoor 2000E / UPS-2000E12ms
Waveform
Outdoor 2000A / UPS-2000APure Sine Wave
Outdoor 2000E / UPS-2000EPure Sine Wave
Nominal Voltage
Outdoor 2000A / UPS-2000A120 VAC
Outdoor 2000E / UPS-2000E230/240 VAC
Efficiency AVR Mode
Outdoor 2000A / UPS-2000A90%
Outdoor 2000E / UPS-2000E90%
Efficiency Battery Mode
Outdoor 2000A / UPS-2000A90%
Outdoor 2000E / UPS-2000E90%
Efficiency Line Mode
Outdoor 2000A / UPS-2000A95%
Outdoor 2000E / UPS-2000E95%
Voltage Regulation (Batt. Mode)
Outdoor 2000A / UPS-2000A120 VAC ± 5%
Outdoor 2000E / UPS-2000E230/240 VAC ± 5%
Frequency
Outdoor 2000A / UPS-2000A50Hz/60Hz ± 0.1%
Outdoor 2000E / UPS-2000E50Hz/60Hz ± 0.1%
THD (Batt. Mode)
Outdoor 2000A / UPS-2000A<3% @ Full resistive load
Outdoor 2000E / UPS-2000E<3% @ Full resistive load
BATTERY
Battery Type
Outdoor 2000A / UPS-2000AAGM
Outdoor 2000E / UPS-2000EAGM
Charging Current
Outdoor 2000A / UPS-2000A2A/4A/6A/8A/10A (Adjustable)
Outdoor 2000E / UPS-2000E2A/4A/6A/8A/10A (Adjustable)
Low DC Warning Voltage
Outdoor 2000A / UPS-2000A46VDC ± 0.4VDC @ no load
Outdoor 2000E / UPS-2000E46VDC ± 0.4VDC @ no load
Nominal DC Voltage
Outdoor 2000A / UPS-2000A48 VDC
Outdoor 2000E / UPS-2000E48 VDC
INDICATORS
Battery Mode
Outdoor 2000A / UPS-2000AGreen LED flashing
Outdoor 2000E / UPS-2000EGreen LED flashing
Bypass Mode
Outdoor 2000A / UPS-2000AGreen LED on
Outdoor 2000E / UPS-2000EGreen LED on
Fault without Output
Outdoor 2000A / UPS-2000ARed LED on
Outdoor 2000E / UPS-2000ERed LED on
No Output
Outdoor 2000A / UPS-2000AGreen LED Off
Outdoor 2000E / UPS-2000EGreen LED Off
Warning with Output
Outdoor 2000A / UPS-2000AYellow LED on
Outdoor 2000E / UPS-2000EYellow LED on
ENVIRONMENT
Operating Temperature
Outdoor 2000A / UPS-2000A-40°C to 80°C
Outdoor 2000E / UPS-2000E-40°C to 70°C
Humidity
Outdoor 2000A / UPS-2000A5% to 95% Relative Humidity(Non-condensing)
Outdoor 2000E / UPS-2000E5% to 95% Relative Humidity(Non-condensing)
Noise Level
Outdoor 2000A / UPS-2000A< 48dB
Outdoor 2000E / UPS-2000E< 48dB
PHYSICAL
Dimension, D X W X H (mm)
Outdoor 2000A / UPS-2000A240 x400 x 133
Outdoor 2000E / UPS-2000E240 x400 x 133
Net Weight (kgs)
Outdoor 2000A / UPS-2000A13
Outdoor 2000E / UPS-2000E13
Type of Mechanical Protection
Outdoor 2000A / UPS-2000AIP 20
Outdoor 2000E / UPS-2000EIP 20
COMPLIANCE
EMI Compliance
Outdoor 2000A / UPS-2000AClass A FCC/CISPR [EN50091-2: 1995]
Outdoor 2000E / UPS-2000EClass A FCC/CISPR [EN50091-2: 1995]
Surge Protection
Outdoor 2000A / UPS-2000AIEEE/ANSI C.62.41 & 2KV, L-N
Outdoor 2000E / UPS-2000EIEEE/ANSI C.62.41 & 2KV, L-N
MANAGEMENT
Communication
Outdoor 2000A / UPS-2000AUSB, RS-232 and optional SNMP
Outdoor 2000E / UPS-2000EUSB, RS-232 and optional SNMP
Dry Contact Rating
Outdoor 2000A / UPS-2000A3A @ 125VAC
Outdoor 2000E / UPS-2000E3A @ 250VAC