94
Otima II Tower 800VA-5KVA
Line-Interactive UPS with SineWave
Available in ratings from 800VA to 5KVA, Otima offers server-quality full power protection against power outages, spikes, and surges, all within a compact design and delivering a strong output power factor of 0.9. This series is ideal for networking, telecommunications, servers, and other mission-critical uses.
Main Features
- Pure sine wave output
- Output power factor of 0.9
- Programmable power management outlets
- ECO (Efficiency Corrective Optimizer) mode for enhanced energy savings
- Exceptional efficiency during battery operation
- Boost and Buck AVR for stable voltage regulation
- Multiple communication options available
- 3-stage intelligent battery charging control
- Optional HID Power Device USB port
| MODEL | Otima II T 800 | Otima II T 1.1K | Otima II T 1.5K | Otima II T 2K | Otima II T 2.5K | Otima II T 3K | |
| CAPACITY | 800 VA / 720 W | 1100 VA / 990 W | 1500 VA / 1350 W | 2000 VA / 1800 W | 2500 VA / 2250 W | 3000 VA / 2700 W | |
| INPUT | |||||||
| Nominal Voltage | 110/115/120/127 VAC or 208/220/230/240 VAC | 110/115/120/127 VAC or 208/220/230/240 VAC | 110/115/120/127 VAC or 208/220/230/240 VAC | 110/115/120/127 VAC or 208/220/230/240 VAC | 110/115/120/127 VAC or 208/220/230/240 VAC | 110/115/120/127 VAC or 208/220/230/240 VAC | |
| Acceptable Voltage Range | 81-152 VAC or 162-290 VAC | 81-152 VAC or 162-290 VAC | 81-152 VAC or 162-290 VAC | 81-152 VAC or 162-290 VAC | 81-152 VAC or 162-290 VAC | 81-152 VAC or 162-290 VAC | |
| Frequency Range | 60/50 Hz (auto sensing) | 60/50 Hz (auto sensing) | 60/50 Hz (auto sensing) | 60/50 Hz (auto sensing) | 60/50 Hz (auto sensing) | 60/50 Hz (auto sensing) | |
| OUTPUT | |||||||
| Output Voltage | 110/115/120/127 VAC or 208/220/230/240 VAC | 110/115/120/127 VAC or 208/220/230/240 VAC | 110/115/120/127 VAC or 208/220/230/240 VAC | 110/115/120/127 VAC or 208/220/230/240 VAC | 110/115/120/127 VAC or 208/220/230/240 VAC | 110/115/120/127 VAC or 208/220/230/240 VAC | |
| Frequency Range (Batt. Mode) | 50 Hz or 60 Hz ± 1 Hz | 50 Hz or 60 Hz ± 1 Hz | 50 Hz or 60 Hz ± 1 Hz | 50 Hz or 60 Hz ± 1 Hz | 50 Hz or 60 Hz ± 1 Hz | 50 Hz or 60 Hz ± 1 Hz | |
| Transfer Time | Typical 2-6 ms, 10ms max. | Typical 2-6 ms, 10ms max. | Typical 2-6 ms, 10ms max. | Typical 2-6 ms, 10ms max. | Typical 2-6 ms, 10ms max. | Typical 2-6 ms, 10ms max. | |
| Waveform (Batt. Mode) | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | |
| Voltage Regulation (Batt. Mode) | ± 1.5% (before battery alarm) | ± 1.5% (before battery alarm) | ± 1.5% (before battery alarm) | ± 1.5% (before battery alarm) | ± 1.5% (before battery alarm) | ± 1.5% (before battery alarm) | |
| Current Crest Ratio | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 | |
| Harmonic Distortion | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) | |
| EFFICIENCY | |||||||
| Battery Mode | ≧ 88%, up to 90% @ nominal battery voltage | ≧ 88%, up to 90% @ nominal battery voltage | ≧ 88%, up to 90% @ nominal battery voltage | ≧ 88%, up to 90% @ nominal battery voltage | ≧89%, up to 91% @ nominal battery voltage for 110/115/120/127 VAC ≧91%, up to 92% @ nominal battery voltage for 208/220/230/240 VAC | ≧89%, up to 91% @ nominal battery voltage for 110/115/120/127 VAC ≧91%, up to 92% @ nominal battery voltage for 208/220/230/240 VAC | |
| Buck & Boost Mode | 95% | 95% | 95% | 95% | 95% | 95% | |
| ECO Mode | 97% | 97% | 97% | 97% | 97% | 97% | |
| BATTERY | |||||||
| Charging Voltage | 27.4 VDC ± 1% | 27.4 VDC ± 1% | 54.8 VDC ± 1% | 54.8 VDC ± 1% | 82.1 VDC ± 1% | 82.1 VDC ± 1% | |
| Charging Current (max.) | 1.5 A | 1.5 A | 1.5 A | 1.5 A | 1.5 A | 1.5 A | |
| Typical Recharge Time | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | |
| Battery Type & Numbers | 12 V/7 Ah x 2 | 12 V/9 Ah x 2 | 12 V/7 Ah x 4 | 12 V/9 Ah x 4 | 12 V/7 Ah x 6 | 12 V/9 Ah x 6 | |
| PROTECTION | |||||||
| Full Protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection | |
| INDICATORS | |||||||
| LCD Display | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery | |
| ALARM | |||||||
| Battery Mode | Sounding every 10 seconds | Sounding every 10 seconds | Sounding every 10 seconds | Sounding every 10 seconds | Sounding every 10 seconds | Sounding every 10 seconds | |
| Low Battery | Sounding every 2 seconds | Sounding every 2 seconds | Sounding every 2 seconds | Sounding every 2 seconds | Sounding every 2 seconds | Sounding every 2 seconds | |
| Overload | Sounding every second | Sounding every second | Sounding every second | Sounding every second | Sounding every second | Sounding every second | |
| Fault | Continuously sounding | Continuously sounding | Continuously sounding | Continuously sounding | Continuously sounding | Continuously sounding | |
| ENVIRONMENT | |||||||
| Operating Humidity | 0~90% RH @ 0- 40°C (non-condensing) | 0~90% RH @ 0- 40°C (non-condensing) | 0~90% RH @ 0- 40°C (non-condensing) | 0~90% RH @ 0- 40°C (non-condensing) | 0~90% RH @ 0- 40°C (non-condensing) | 0~90% RH @ 0- 40°C (non-condensing) | |
| Noise Level | Less than 45dB | Less than 45dB | Less than 45dB | Less than 45dB | Less than 45dB | Less than 45dB | |
| PHYSICAL | |||||||
| Net Weight (kgs) | 11.7 | 12.1 | 17.2 | 19.7 | 26.6 | 29 | |
| Dimension, DXWXH (mm) | 397 x 145 x 220 | 397 x 145 x 220 | 455 x 145 x 220 | 455 x 145 x 220 | 421 x 190 x 318 | 421 x 190 x 318 | |
| MANAGEMENT | |||||||
| Optional SNMP | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | |
| Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | |
| Model | Otima II T 5K | |
| CAPACITY | 5000 VA / 4500 W | |
| INPUT | ||
| Nominal Voltage | 208/220/230/240 VAC | |
| Acceptable Voltage Range | 162-290 VAC | |
| Frequency Range | 60/50 Hz (auto sensing) | |
| OUTPUT | ||
| Output Voltage | 208/220/230/240 VAC | |
| Frequency Range (Batt. Mode) | 50 Hz or 60 Hz ± 1 Hz | |
| Transfer Time | Typical 2-6 ms, 10ms max. | |
| Waveform (Batt. Mode) | Pure Sine Wave | |
| Voltage Regulation (Batt. Mode) | ± 1.5% (before battery alarm) | |
| Current Crest Ratio | 3:1 | |
| Harmonic Distortion | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) | |
| EFFICIENCY | ||
| Battery Mode | ≧91%, up to 92% @ nominal battery voltage | |
| Buck & Boost Mode | 95% | |
| ECO Mode | 97% | |
| BATTERY | ||
| Charging Voltage | 82.1 VDC ± 1% | |
| Charging Current (max.) | 1.5 A | |
| Typical Recharge Time | 4 hours recover to 90% capacity | |
| Battery Type & Numbers | 12 V/10 Ah x 6 | |
| PROTECTION | ||
| Full Protection | Overload, discharge, and overcharge protection | |
| INDICATORS | ||
| LCD Display | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery | |
| ALARM | ||
| Battery Mode | Sounding every 10 seconds | |
| Low Battery | Sounding every 2 seconds | |
| Overload | Sounding every second | |
| Fault | Continuously sounding | |
| ENVIRONMENT | ||
| Operating Humidity | 0~90% RH @ 0- 40°C (non-condensing) | |
| Noise Level | Less than 45dB | |
| PHYSICAL | ||
| Net Weight (kgs) | 34.5 | |
| Dimension, DXWXH (mm) | 421 x 190 x 318 | |
| MANAGEMENT | ||
| Optional SNMP | Power management from SNMP manager and web browser | |
| Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | |
General
CAPACITY
| Otima II T 800 | 800 VA / 720 W |
|---|---|
| Otima II T 1.1K | 1100 VA / 990 W |
| Otima II T 1.5K | 1500 VA / 1350 W |
| Otima II T 2K | 2000 VA / 1800 W |
| Otima II T 2.5K | 2500 VA / 2250 W |
| Otima II T 3K | 3000 VA / 2700 W |
| Otima II T 5K | 5000 VA / 4500 W |
INPUT
Nominal Voltage
| Otima II T 800 | 110/115/120/127 VAC or 208/220/230/240 VAC |
|---|---|
| Otima II T 1.1K | 110/115/120/127 VAC or 208/220/230/240 VAC |
| Otima II T 1.5K | 110/115/120/127 VAC or 208/220/230/240 VAC |
| Otima II T 2K | 110/115/120/127 VAC or 208/220/230/240 VAC |
| Otima II T 2.5K | 110/115/120/127 VAC or 208/220/230/240 VAC |
| Otima II T 3K | 110/115/120/127 VAC or 208/220/230/240 VAC |
| Otima II T 5K | 208/220/230/240 VAC |
Acceptable Voltage Range
| Otima II T 800 | 81-152 VAC or 162-290 VAC |
|---|---|
| Otima II T 1.1K | 81-152 VAC or 162-290 VAC |
| Otima II T 1.5K | 81-152 VAC or 162-290 VAC |
| Otima II T 2K | 81-152 VAC or 162-290 VAC |
| Otima II T 2.5K | 81-152 VAC or 162-290 VAC |
| Otima II T 3K | 81-152 VAC or 162-290 VAC |
| Otima II T 5K | 162-290 VAC |
Frequency Range
| Otima II T 800 | 60/50 Hz (auto sensing) |
|---|---|
| Otima II T 1.1K | 60/50 Hz (auto sensing) |
| Otima II T 1.5K | 60/50 Hz (auto sensing) |
| Otima II T 2K | 60/50 Hz (auto sensing) |
| Otima II T 2.5K | 60/50 Hz (auto sensing) |
| Otima II T 3K | 60/50 Hz (auto sensing) |
| Otima II T 5K | 60/50 Hz (auto sensing) |
OUTPUT
Output Voltage
| Otima II T 800 | 110/115/120/127 VAC or 208/220/230/240 VAC |
|---|---|
| Otima II T 1.1K | 110/115/120/127 VAC or 208/220/230/240 VAC |
| Otima II T 1.5K | 110/115/120/127 VAC or 208/220/230/240 VAC |
| Otima II T 2K | 110/115/120/127 VAC or 208/220/230/240 VAC |
| Otima II T 2.5K | 110/115/120/127 VAC or 208/220/230/240 VAC |
| Otima II T 3K | 110/115/120/127 VAC or 208/220/230/240 VAC |
| Otima II T 5K | 208/220/230/240 VAC |
Frequency Range (Batt. Mode)
| Otima II T 800 | 50 Hz or 60 Hz ± 1 Hz |
|---|---|
| Otima II T 1.1K | 50 Hz or 60 Hz ± 1 Hz |
| Otima II T 1.5K | 50 Hz or 60 Hz ± 1 Hz |
| Otima II T 2K | 50 Hz or 60 Hz ± 1 Hz |
| Otima II T 2.5K | 50 Hz or 60 Hz ± 1 Hz |
| Otima II T 3K | 50 Hz or 60 Hz ± 1 Hz |
| Otima II T 5K | 50 Hz or 60 Hz ± 1 Hz |
Transfer Time
| Otima II T 800 | Typical 2-6 ms, 10ms max. |
|---|---|
| Otima II T 1.1K | Typical 2-6 ms, 10ms max. |
| Otima II T 1.5K | Typical 2-6 ms, 10ms max. |
| Otima II T 2K | Typical 2-6 ms, 10ms max. |
| Otima II T 2.5K | Typical 2-6 ms, 10ms max. |
| Otima II T 3K | Typical 2-6 ms, 10ms max. |
| Otima II T 5K | Typical 2-6 ms, 10ms max. |
Waveform (Batt. Mode)
| Otima II T 800 | Pure Sine Wave |
|---|---|
| Otima II T 1.1K | Pure Sine Wave |
| Otima II T 1.5K | Pure Sine Wave |
| Otima II T 2K | Pure Sine Wave |
| Otima II T 2.5K | Pure Sine Wave |
| Otima II T 3K | Pure Sine Wave |
| Otima II T 5K | Pure Sine Wave |
Voltage Regulation (Batt. Mode)
| Otima II T 800 | ± 1.5% (before battery alarm) |
|---|---|
| Otima II T 1.1K | ± 1.5% (before battery alarm) |
| Otima II T 1.5K | ± 1.5% (before battery alarm) |
| Otima II T 2K | ± 1.5% (before battery alarm) |
| Otima II T 2.5K | ± 1.5% (before battery alarm) |
| Otima II T 3K | ± 1.5% (before battery alarm) |
| Otima II T 5K | ± 1.5% (before battery alarm) |
Current Crest Ratio
| Otima II T 800 | 3:1 |
|---|---|
| Otima II T 1.1K | 3:1 |
| Otima II T 1.5K | 3:1 |
| Otima II T 2K | 3:1 |
| Otima II T 2.5K | 3:1 |
| Otima II T 3K | 3:1 |
| Otima II T 5K | 3:1 |
Harmonic Distortion
| Otima II T 800 | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) |
|---|---|
| Otima II T 1.1K | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) |
| Otima II T 1.5K | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) |
| Otima II T 2K | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) |
| Otima II T 2.5K | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) |
| Otima II T 3K | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) |
| Otima II T 5K | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) |
EFFICIENCY
Battery Mode
| Otima II T 800 | ≧ 88%, up to 90% @ nominal battery voltage |
|---|---|
| Otima II T 1.1K | ≧ 88%, up to 90% @ nominal battery voltage |
| Otima II T 1.5K | ≧ 88%, up to 90% @ nominal battery voltage |
| Otima II T 2K | ≧ 88%, up to 90% @ nominal battery voltage |
| Otima II T 2.5K | ≧89%, up to 91% @ nominal battery voltage for 110/115/120/127 VAC ≧91%, up to 92% @ nominal battery voltage for 208/220/230/240 VAC |
| Otima II T 3K | ≧89%, up to 91% @ nominal battery voltage for 110/115/120/127 VAC ≧91%, up to 92% @ nominal battery voltage for 208/220/230/240 VAC |
| Otima II T 5K | ≧91%, up to 92% @ nominal battery voltage |
Buck & Boost Mode
| Otima II T 800 | 95% |
|---|---|
| Otima II T 1.1K | 95% |
| Otima II T 1.5K | 95% |
| Otima II T 2K | 95% |
| Otima II T 2.5K | 95% |
| Otima II T 3K | 95% |
| Otima II T 5K | 95% |
ECO Mode
| Otima II T 800 | 97% |
|---|---|
| Otima II T 1.1K | 97% |
| Otima II T 1.5K | 97% |
| Otima II T 2K | 97% |
| Otima II T 2.5K | 97% |
| Otima II T 3K | 97% |
| Otima II T 5K | 97% |
BATTERY
Charging Voltage
| Otima II T 800 | 27.4 VDC ± 1% |
|---|---|
| Otima II T 1.1K | 27.4 VDC ± 1% |
| Otima II T 1.5K | 54.8 VDC ± 1% |
| Otima II T 2K | 54.8 VDC ± 1% |
| Otima II T 2.5K | 82.1 VDC ± 1% |
| Otima II T 3K | 82.1 VDC ± 1% |
| Otima II T 5K | 82.1 VDC ± 1% |
Charging Current (max.)
| Otima II T 800 | 1.5 A |
|---|---|
| Otima II T 1.1K | 1.5 A |
| Otima II T 1.5K | 1.5 A |
| Otima II T 2K | 1.5 A |
| Otima II T 2.5K | 1.5 A |
| Otima II T 3K | 1.5 A |
| Otima II T 5K | 1.5 A |
Typical Recharge Time
| Otima II T 800 | 4 hours recover to 90% capacity |
|---|---|
| Otima II T 1.1K | 4 hours recover to 90% capacity |
| Otima II T 1.5K | 4 hours recover to 90% capacity |
| Otima II T 2K | 4 hours recover to 90% capacity |
| Otima II T 2.5K | 4 hours recover to 90% capacity |
| Otima II T 3K | 4 hours recover to 90% capacity |
| Otima II T 5K | 4 hours recover to 90% capacity |
Battery Type & Numbers
| Otima II T 800 | 12 V/7 Ah x 2 |
|---|---|
| Otima II T 1.1K | 12 V/9 Ah x 2 |
| Otima II T 1.5K | 12 V/7 Ah x 4 |
| Otima II T 2K | 12 V/9 Ah x 4 |
| Otima II T 2.5K | 12 V/7 Ah x 6 |
| Otima II T 3K | 12 V/9 Ah x 6 |
| Otima II T 5K | 12 V/10 Ah x 6 |
PROTECTION
Full Protection
| Otima II T 800 | Overload, discharge, and overcharge protection |
|---|---|
| Otima II T 1.1K | Overload, discharge, and overcharge protection |
| Otima II T 1.5K | Overload, discharge, and overcharge protection |
| Otima II T 2K | Overload, discharge, and overcharge protection |
| Otima II T 2.5K | Overload, discharge, and overcharge protection |
| Otima II T 3K | Overload, discharge, and overcharge protection |
| Otima II T 5K | Overload, discharge, and overcharge protection |
INDICATORS
LCD Display
| Otima II T 800 | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery |
|---|---|
| Otima II T 1.1K | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery |
| Otima II T 1.5K | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery |
| Otima II T 2K | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery |
| Otima II T 2.5K | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery |
| Otima II T 3K | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery |
| Otima II T 5K | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery |
ALARM
Battery Mode
| Otima II T 800 | Sounding every 10 seconds |
|---|---|
| Otima II T 1.1K | Sounding every 10 seconds |
| Otima II T 1.5K | Sounding every 10 seconds |
| Otima II T 2K | Sounding every 10 seconds |
| Otima II T 2.5K | Sounding every 10 seconds |
| Otima II T 3K | Sounding every 10 seconds |
| Otima II T 5K | Sounding every 10 seconds |
Low Battery
| Otima II T 800 | Sounding every 2 seconds |
|---|---|
| Otima II T 1.1K | Sounding every 2 seconds |
| Otima II T 1.5K | Sounding every 2 seconds |
| Otima II T 2K | Sounding every 2 seconds |
| Otima II T 2.5K | Sounding every 2 seconds |
| Otima II T 3K | Sounding every 2 seconds |
| Otima II T 5K | Sounding every 2 seconds |
Overload
| Otima II T 800 | Sounding every second |
|---|---|
| Otima II T 1.1K | Sounding every second |
| Otima II T 1.5K | Sounding every second |
| Otima II T 2K | Sounding every second |
| Otima II T 2.5K | Sounding every second |
| Otima II T 3K | Sounding every second |
| Otima II T 5K | Sounding every second |
Fault
| Otima II T 800 | Continuously sounding |
|---|---|
| Otima II T 1.1K | Continuously sounding |
| Otima II T 1.5K | Continuously sounding |
| Otima II T 2K | Continuously sounding |
| Otima II T 2.5K | Continuously sounding |
| Otima II T 3K | Continuously sounding |
| Otima II T 5K | Continuously sounding |
ENVIRONMENT
Operating Humidity
| Otima II T 800 | 0~90% RH @ 0- 40°C (non-condensing) |
|---|---|
| Otima II T 1.1K | 0~90% RH @ 0- 40°C (non-condensing) |
| Otima II T 1.5K | 0~90% RH @ 0- 40°C (non-condensing) |
| Otima II T 2K | 0~90% RH @ 0- 40°C (non-condensing) |
| Otima II T 2.5K | 0~90% RH @ 0- 40°C (non-condensing) |
| Otima II T 3K | 0~90% RH @ 0- 40°C (non-condensing) |
| Otima II T 5K | 0~90% RH @ 0- 40°C (non-condensing) |
Noise Level
| Otima II T 800 | Less than 45dB |
|---|---|
| Otima II T 1.1K | Less than 45dB |
| Otima II T 1.5K | Less than 45dB |
| Otima II T 2K | Less than 45dB |
| Otima II T 2.5K | Less than 45dB |
| Otima II T 3K | Less than 45dB |
| Otima II T 5K | Less than 45dB |
PHYSICAL
Net Weight (kgs)
| Otima II T 800 | 11.7 |
|---|---|
| Otima II T 1.1K | 12.1 |
| Otima II T 1.5K | 17.2 |
| Otima II T 2K | 19.7 |
| Otima II T 2.5K | 26.6 |
| Otima II T 3K | 29 |
| Otima II T 5K | 34.5 |
Dimension, DXWXH (mm)
| Otima II T 800 | 397 x 145 x 220 |
|---|---|
| Otima II T 1.1K | 397 x 145 x 220 |
| Otima II T 1.5K | 455 x 145 x 220 |
| Otima II T 2K | 455 x 145 x 220 |
| Otima II T 2.5K | 421 x 190 x 318 |
| Otima II T 3K | 421 x 190 x 318 |
| Otima II T 5K | 421 x 190 x 318 |
MANAGEMENT
Optional SNMP
| Otima II T 800 | Power management from SNMP manager and web browser |
|---|---|
| Otima II T 1.1K | Power management from SNMP manager and web browser |
| Otima II T 1.5K | Power management from SNMP manager and web browser |
| Otima II T 2K | Power management from SNMP manager and web browser |
| Otima II T 2.5K | Power management from SNMP manager and web browser |
| Otima II T 3K | Power management from SNMP manager and web browser |
| Otima II T 5K | Power management from SNMP manager and web browser |
Smart RS-232 / USB
| Otima II T 800 | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
|---|---|
| Otima II T 1.1K | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
| Otima II T 1.5K | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
| Otima II T 2K | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
| Otima II T 2.5K | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
| Otima II T 3K | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
| Otima II T 5K | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
| Brochure | OtimaII _Tower_DS_Brochure | |
| Manual | OtimaII-Tower-1K-5K-manual |
Line Interactive UPS Otima II Tower 800VA-5KVA Line-Interactive UPS with SineWave