Library 600VA-2KVA
Backup power during a long-term outage
As a long-duration UPS, the Library series can connect to external batteries to deliver continuous backup power during extended outages. Featuring dual boost and single buck capabilities, it can operate indefinitely through prolonged brownouts and overvoltages without depleting the battery. This design helps conserve battery life during power interruptions.
Main Features
- Simulated sine wave output available in 600VA, 1KVA, and 2KVA models
- Boost and buck Automatic Voltage Regulation (AVR) for stable voltage performance
- Adjustable charging current to suit your needs
- Automatic restart when AC power is restored
- Charging capability even when the unit is turned off
- Cold start function for starting without AC power
- Integrated super charger designed to support extended backup time with an external battery
- Optional compatibility with generators
| MODEL | Library 600 | Library 1000 | Library 2000 | |
| CAPACITY | 600 VA / 360 W | 1000 VA / 600 W | 2000 VA / 1200 W | |
| INPUT | ||||
| Voltage | 220/230 VAC | 220/230 VAC | 220/230 VAC | |
| Voltage Range | 140-300 VAC | 140-300 VAC | 140-300 VAC | |
| Frequency Range | 50 Hz | 50 Hz | 50 Hz | |
| OUTPUT | ||||
| AC Voltage Regulation (Batt. Mode) | 220/230 VAC ± 10% | 220/230 VAC ± 10% | 220/230 VAC ± 10% | |
| Frequency Range (Batt. Mode) | 50 Hz ± 1 Hz | 50 Hz ± 1 Hz | 50 Hz ± 1 Hz | |
| Transfer Time | Typical 4-8 ms | Typical 4-8 ms | Typical 4-8 ms | |
| Waveform (Batt. Mode) | Simulated Sine Wave | Simulated Sine Wave | Simulated Sine Wave | |
| BATTERY | ||||
| Battery Voltage | 12 VDC | 12 VDC | 24 VDC | |
| Floating Charge Voltage | 13.7 VDC ± 2% | 13.7 VDC ± 2% | 27.4 VDC ± 2% | |
| Maximum Charging Current | 2.5A/6A/10A (Adjustable from manufacturer) | 5A/10A/15A/20A (Adjustable from manufacturer) | 5A/10A/15A/20A (Adjustable from manufacturer) | |
| PROTECTION | ||||
| Full Protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection | |
| INDICATORS | ||||
| AC Mode | Green lighting | Green lighting | Green lighting | |
| Battery Mode | Yellow flashing | Yellow flashing | Yellow flashing | |
| Fault | Red lighting | Red lighting | Red lighting | |
| ALARM | ||||
| Low Battery | Sounding every second | Sounding every second | Sounding every second | |
| Overload | Sounding every 0.5 second | Sounding every 0.5 second | Sounding every 0.5 second | |
| Battery Replacement | Sounding every 2 seconds | Sounding every 2 seconds | Sounding every 2 seconds | |
| Fault | Continuously sounding | Continuously sounding | Continuously sounding | |
| PHYSICAL | ||||
| Dimension, D X W X H (mm) | 358.5 x 96.8 x 146.5 | 395 x 145 x 220 | 395 x 145 x 220 | |
| Net Weight (kgs) | 5.8 | 9.0 | 13.55 | |
| OPERATING ENVIRONMENT | ||||
| Operating Humidity | 0~90% RH @ 0- 40°C (non-condensing) | 0~90% RH @ 0- 40°C (non-condensing) | 0~90% RH @ 0- 40°C (non-condensing) | |
| Noise Level | Less than 40dB | Less than 40dB | Less than 40dB | |
General
CAPACITY
| Library 600 | 600 VA / 360 W |
|---|---|
| Library 1000 | 1000 VA / 600 W |
| Library 2000 | 2000 VA / 1200 W |
INPUT
Voltage
| Library 600 | 220/230 VAC |
|---|---|
| Library 1000 | 220/230 VAC |
| Library 2000 | 220/230 VAC |
Voltage Range
| Library 600 | 140-300 VAC |
|---|---|
| Library 1000 | 140-300 VAC |
| Library 2000 | 140-300 VAC |
Frequency Range
| Library 600 | 50 Hz |
|---|---|
| Library 1000 | 50 Hz |
| Library 2000 | 50 Hz |
OUTPUT
AC Voltage Regulation (Batt. Mode)
| Library 600 | 220/230 VAC ± 10% |
|---|---|
| Library 1000 | 220/230 VAC ± 10% |
| Library 2000 | 220/230 VAC ± 10% |
Frequency Range (Batt. Mode)
| Library 600 | 50 Hz ± 1 Hz |
|---|---|
| Library 1000 | 50 Hz ± 1 Hz |
| Library 2000 | 50 Hz ± 1 Hz |
Transfer Time
| Library 600 | Typical 4-8 ms |
|---|---|
| Library 1000 | Typical 4-8 ms |
| Library 2000 | Typical 4-8 ms |
Waveform (Batt. Mode)
| Library 600 | Simulated Sine Wave |
|---|---|
| Library 1000 | Simulated Sine Wave |
| Library 2000 | Simulated Sine Wave |
BATTERY
Battery Voltage
| Library 600 | 12 VDC |
|---|---|
| Library 1000 | 12 VDC |
| Library 2000 | 24 VDC |
Floating Charge Voltage
| Library 600 | 13.7 VDC ± 2% |
|---|---|
| Library 1000 | 13.7 VDC ± 2% |
| Library 2000 | 27.4 VDC ± 2% |
Maximum Charging Current
| Library 600 | 2.5A/6A/10A (Adjustable from manufacturer) |
|---|---|
| Library 1000 | 5A/10A/15A/20A (Adjustable from manufacturer) |
| Library 2000 | 5A/10A/15A/20A (Adjustable from manufacturer) |
PROTECTION
Full Protection
| Library 600 | Overload, discharge, and overcharge protection |
|---|---|
| Library 1000 | Overload, discharge, and overcharge protection |
| Library 2000 | Overload, discharge, and overcharge protection |
INDICATORS
AC Mode
| Library 600 | Green lighting |
|---|---|
| Library 1000 | Green lighting |
| Library 2000 | Green lighting |
Battery Mode
| Library 600 | Yellow flashing |
|---|---|
| Library 1000 | Yellow flashing |
| Library 2000 | Yellow flashing |
Fault
| Library 600 | Red lighting |
|---|---|
| Library 1000 | Red lighting |
| Library 2000 | Red lighting |
ALARM
Low Battery
| Library 600 | Sounding every second |
|---|---|
| Library 1000 | Sounding every second |
| Library 2000 | Sounding every second |
Overload
| Library 600 | Sounding every 0.5 second |
|---|---|
| Library 1000 | Sounding every 0.5 second |
| Library 2000 | Sounding every 0.5 second |
Battery Replacement
| Library 600 | Sounding every 2 seconds |
|---|---|
| Library 1000 | Sounding every 2 seconds |
| Library 2000 | Sounding every 2 seconds |
Fault
| Library 600 | Continuously sounding |
|---|---|
| Library 1000 | Continuously sounding |
| Library 2000 | Continuously sounding |
PHYSICAL
Dimension, D X W X H (mm)
| Library 600 | 358.5 x 96.8 x 146.5 |
|---|---|
| Library 1000 | 395 x 145 x 220 |
| Library 2000 | 395 x 145 x 220 |
Net Weight (kgs)
| Library 600 | 5.8 |
|---|---|
| Library 1000 | 9.0 |
| Library 2000 | 13.55 |
OPERATING ENVIRONMENT
Operating Humidity
| Library 600 | 0~90% RH @ 0- 40°C (non-condensing) |
|---|---|
| Library 1000 | 0~90% RH @ 0- 40°C (non-condensing) |
| Library 2000 | 0~90% RH @ 0- 40°C (non-condensing) |
Noise Level
| Library 600 | Less than 40dB |
|---|---|
| Library 1000 | Less than 40dB |
| Library 2000 | Less than 40dB |