Lithium-ion Battery Module
The LIO 4805 / 4810 is a lithium-ion battery module built for modular expansion. It allows up to 10 units to be connected in parallel to increase capacity, making it suitable for a wide range of uses.
Main Features
  • Modular design allows easy scalability with up to 10 units connected in parallel to increase capacity.
  • Includes a built-in Battery Management System (BMS) that communicates with the power module through RS-485.
  • Designed to handle high discharge currents.
  • Features a finger-safe design for the external battery connector.
  • Supports flexible installation from both the front and rear.
  • Equipped with a built-in breaker to ensure safe operation.
  • Supports custom protocol upgrades for customer-specific needs.
General
CAPACITY
LIO 48052400Wh
LIO 48104800Wh
PARAMETERS
Norminal Voltage
LIO 480548 Vdc
LIO 481048 Vdc
Full Charge Voltage(FC)
LIO 480552.5 VDC
LIO 481052.5 VDC
Full Discharge Voltage(FD)
LIO 480534.5 VDC
LIO 481034.5 VDC
Typical Capacity
LIO 480550 Ah
LIO 4810100 Ah
Max. Discharging Current
LIO 480575 A
LIO 4810150 A
Protection
LIO 4805BMS, Breaker
LIO 4810BMS, Breaker
Charge Voltage
LIO 480552.5 ± 0.1 V
LIO 481052.5 ± 0.1 V
Maximum Charge Current
LIO 480550A (0.5C)
LIO 4810100A (0.5C)
Standard Charge method
LIO 48050.2C CC (Constant current) charge to FC, CV (Contstant voltage FC) charge till charge current decline to <0.05C
LIO 4810<20m ohm
Inner Resistance
LIO 4805<20m ohm
LIO 4810Battery Status, Battery level, Battery fault, Alarm
INDICATORS
LED
LIO 4805Battery Status, Battery level, Battery fault, Alarm
LIO 4810Charge: 0°C~50 °C ; Discharge: 0°C~50 °C
ENVIRONMENT
Operation Temperature
LIO 4805Charge: 0°C~50 °C ; Discharge: 0°C~50 °C
LIO 4810< 18 months: -20°C~25 °C < 3 months: 25°C~45 °C < 1 months: 45°C~60 °C 20°C±5 °C is the recommended storage temperature
Storage Temperature (At 50% SOC and specified temp, recoverable capacity in % vs time / 50%)
LIO 4805< 18 months: -20°C~25 °C < 3 months: 25°C~45 °C < 1 months: 45°C~60 °C 20°C±5 °C is the recommended storage temperature
LIO 4810< 18 months: -20°C~25 °C < 3 months: 25°C~45 °C < 1 months: 45°C~60 °C 20°C±5 °C is the recommended storage temperature
PHYSICAL
Dimension, D x W x H (mm)
LIO 4805676 x 438 x 86
LIO 4810676 x 438 x 129
Net Weight(Kg)
LIO 480531.6
LIO 481044.8
MANAGEMENT
Communication
LIO 4805RS485 port (RJ45), extension port (RJ11)
LIO 4810RS485 port (RJ45), extension port (RJ11)
Certifications
LIO 4805UN38.3, IEC 62619
LIO 4810UN38.3, IEC 62619