- Select Capacity
- InfiniSolar WP II 30KW
- InfiniSolar WP II 50KW
- Select Capacity
- InfiniSolar WP II 30KW
- InfiniSolar WP II 50KW
320
InfiniSolar WP II 30KW/50KW (Three-Phase)
Easy-to-use HMI with a robust IP65-rated casing
The InfiniSolar WP II 30kW/50kW features an easy-to-use HMI. Its IP65 rating ensures protection against dust and moisture, making it suitable for both indoor and outdoor environments. It supports a wide battery input voltage range from 200V to 1000V, providing flexible configuration options. Up to four units can operate in parallel, sharing a common battery, which allows for a combined power capacity of up to 120kW or 200kW, offering scalability and cost efficiency. Built-in Wi-Fi enables smart monitoring and convenient management through an app. Additionally, the 50kW model includes a 200A AC pass-through function, permitting roughly 2.5 times the power output to flow from the grid, making it capable of handling heavy motor or inductive loads like water pumps or compressors.
Main Features
- Connect to a high-voltage battery: Accepts a wide input voltage range of 200~1000VDC from lithium batteries, ensuring greater compatibility with various battery chemistries and configurations.
- Connect to 48vdc low-voltage battery through a DC-DC Converter: For efficient conversion of high-voltage DC to lower-voltage DC, expanding application possibilities. Upgrade your system with increased flexibility and simplified integration.
- User-friendly HMI LCD: Simplifies the initial setup, presenting important information prominently on the main screen.
- Wide Battery Voltage Range with Parallel Capability in Common Battery: Parallel operation max to 4 units with shared common batteries by adding more inverters, enabling a total power rating of up to 120kW and 200kW.
- Dual AC Input: Two independent input power sources from the utility and generator ensure uninterrupted AC power and incorporate a large charger for fast battery charging, even with limited available time from AC or solar sources.
| MODEL | InfiniSolar WP II 30KW | InfiniSolar WP II 50KW | |
| PHASE | 3-phase in/3-phase out | 3-phase in/3-phase out | |
| Maximum PV Input Power | 48000 W | 65000 W | |
| Rated Output Power | 30000 W | 50000 W | |
| Maximum Charging Power | 30000 W | 50000 W | |
| GRID-TIE OPERATION | |||
| PV INPUT (DC) | |||
| Nominal DC Voltage / Maximum DC Voltage | 720 VDC / 1000 VDC | 720 VDC / 1000 VDC | |
| Start-up Voltage / Initial Feeding Voltage | 300 VDC / 350 VDC | 300 VDC / 350 VDC | |
| Number of MPP Trackers/Max. Input Current | 3 / 36A for each | 4 / 36A for each | |
| MPP Voltage Range | 350 VDC ~ 900 VDC | 350 VDC ~ 900 VDC | |
| Number of Strings Per MPP Tracker | 2 | 2 | |
| GRID OUTPUT (AC) | |||
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | |
| Output Voltage Range | 184 - 265 VAC per phase | 184 - 265 VAC per phase | |
| Power Factor | 0.9 lag ~ 0.9 lead | 0.9 lag ~ 0.9 lead | |
| EFFICIENCY | |||
| Maximum Conversion Efficiency (DC/AC) | 0.97 | 0.97 | |
| OFF-GRID OPERATION | |||
| AC INPUT | |||
| AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC /180 VAC per phase | 120 - 140 VAC /180 VAC per phase | |
| Acceptable Voltage Range | 170 - 280 VAC per phase | 170 - 280 VAC per phase | |
| Maximum AC Input Current | 50 A | 83 A | |
| PV INPUT (DC) | |||
| Maximum DC Voltage | 1000 VDC | 1000 VDC | |
| Number of MPP Trackers/Max. Input Current | 3 / 36A for each | 4 / 36A for each | |
| MPP Voltage Range | 350 VDC ~ 900 VDC | 350 VDC ~ 900 VDC | |
| BATTERY MODE OUTPUT (AC) | |||
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | |
| Output Waveform | Pure sine wave | Pure sine wave | |
| HYBRID OPERATION | |||
| PV INPUT (DC) | |||
| Start-up Voltage / Initial Feeding Voltage | 320 VDC / 350 VDC | 320 VDC / 350 VDC | |
| Number of MPP Trackers/Max. Input Current | 3 / 36A for each | 4 / 36A for each | |
| MPP Voltage Range | 350 VDC ~ 900 VDC | 350 VDC ~ 900 VDC | |
| Maximum DC Voltage | 1000 VDC | 1000 VDC | |
| GRID OUTPUT (AC) | |||
| Nominal Output Current | 43.5 A per phase | 73 A per phase | |
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | |
| Output Voltage Range | 184 - 265 VAC per phase | 184 - 265 VAC per phase | |
| AC INPUT | |||
| AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC /180 VAC per phase | 120 - 140 VAC /180 VAC per phase | |
| Acceptable Voltage Range | 170 - 280 VAC per phase | 170 - 280 VAC per phase | |
| Maximum AC Input Current | 50 A | 83 A | |
| BATTERY MODE OUTPUT (AC) | |||
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | |
| Efficiency (DC to AC) | 97% | 97% | |
| BATTERY & CHARGER | |||
| Maximum Charging Current | 50 A | 100 A | |
| Battery Voltage Range | 500 ~ 900 VDC | 500 ~ 800 VDC | |
| GENERAL | |||
| PHYSICAL | |||
| Dimension, D X W X H (mm) | 290 x 580 x 900 | 290 x 580 x 900 | |
| Net Weight (kgs) | 90 | 90 | |
| INTERFACE | |||
| Communication Port | RS-232, USB, DRY CONTACT, RS-485, CAN,Wi-Fi | RS-232, USB, DRY CONTACT, RS-485, CAN,Wi-Fi | |
| Intelligent Slot | Optional SNMP, Modbus | Optional SNMP, Modbus | |
| ENVIRONMENT | |||
| Humidity | 0 ~ 100% RH (Non-condensing) | 0 ~ 100% RH (Non-condensing) | |
| Operating Temperature | -25 to 60°C, > 45°C power derating | -25 to 60°C, > 45°C power derating | |
| Altitude | 0 ~ 1000 m** | 0 ~ 1000 m** | |
MODEL
General
PHASE
| InfiniSolar WP II 30KW | 3-phase in/3-phase out |
|---|---|
| InfiniSolar WP II 50KW | 3-phase in/3-phase out |
Maximum PV Input Power
| InfiniSolar WP II 30KW | 48000 W |
|---|---|
| InfiniSolar WP II 50KW | 65000 W |
Rated Output Power
| InfiniSolar WP II 30KW | 30000 W |
|---|---|
| InfiniSolar WP II 50KW | 50000 W |
Maximum Charging Power
| InfiniSolar WP II 30KW | 30000 W |
|---|---|
| InfiniSolar WP II 50KW | 50000 W |
GRID-TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage
| InfiniSolar WP II 30KW | 720 VDC / 1000 VDC |
|---|---|
| InfiniSolar WP II 50KW | 720 VDC / 1000 VDC |
Start-up Voltage / Initial Feeding Voltage
| InfiniSolar WP II 30KW | 300 VDC / 350 VDC |
|---|---|
| InfiniSolar WP II 50KW | 300 VDC / 350 VDC |
Number of MPP Trackers/Max. Input Current
| InfiniSolar WP II 30KW | 3 / 36A for each |
|---|---|
| InfiniSolar WP II 50KW | 4 / 36A for each |
MPP Voltage Range
| InfiniSolar WP II 30KW | 350 VDC ~ 900 VDC |
|---|---|
| InfiniSolar WP II 50KW | 350 VDC ~ 900 VDC |
Number of Strings Per MPP Tracker
| InfiniSolar WP II 30KW | 2 |
|---|---|
| InfiniSolar WP II 50KW | 2 |
GRID OUTPUT (AC)
Nominal Output Voltage
| InfiniSolar WP II 30KW | 230 VAC (P-N) / 400 VAC (P-P) |
|---|---|
| InfiniSolar WP II 50KW | 230 VAC (P-N) / 400 VAC (P-P) |
Output Voltage Range
| InfiniSolar WP II 30KW | 184 - 265 VAC per phase |
|---|---|
| InfiniSolar WP II 50KW | 184 - 265 VAC per phase |
Power Factor
| InfiniSolar WP II 30KW | 0.9 lag ~ 0.9 lead |
|---|---|
| InfiniSolar WP II 50KW | 0.9 lag ~ 0.9 lead |
EFFICIENCY
Maximum Conversion Efficiency (DC/AC)
| InfiniSolar WP II 30KW | 0.97 |
|---|---|
| InfiniSolar WP II 50KW | 0.97 |
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage / Auto Restart Voltage
| InfiniSolar WP II 30KW | 120 - 140 VAC /180 VAC per phase |
|---|---|
| InfiniSolar WP II 50KW | 120 - 140 VAC /180 VAC per phase |
Acceptable Voltage Range
| InfiniSolar WP II 30KW | 170 - 280 VAC per phase |
|---|---|
| InfiniSolar WP II 50KW | 170 - 280 VAC per phase |
Maximum AC Input Current
| InfiniSolar WP II 30KW | 50 A |
|---|---|
| InfiniSolar WP II 50KW | 83 A |
PV INPUT (DC)
Maximum DC Voltage
| InfiniSolar WP II 30KW | 1000 VDC |
|---|---|
| InfiniSolar WP II 50KW | 1000 VDC |
Number of MPP Trackers/Max. Input Current
| InfiniSolar WP II 30KW | 3 / 36A for each |
|---|---|
| InfiniSolar WP II 50KW | 4 / 36A for each |
MPP Voltage Range
| InfiniSolar WP II 30KW | 350 VDC ~ 900 VDC |
|---|---|
| InfiniSolar WP II 50KW | 350 VDC ~ 900 VDC |
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage
| InfiniSolar WP II 30KW | 230 VAC (P-N) / 400 VAC (P-P) |
|---|---|
| InfiniSolar WP II 50KW | 230 VAC (P-N) / 400 VAC (P-P) |
Output Waveform
| InfiniSolar WP II 30KW | Pure sine wave |
|---|---|
| InfiniSolar WP II 50KW | Pure sine wave |
HYBRID OPERATION
PV INPUT (DC)
Start-up Voltage / Initial Feeding Voltage
| InfiniSolar WP II 30KW | 320 VDC / 350 VDC |
|---|---|
| InfiniSolar WP II 50KW | 320 VDC / 350 VDC |
Number of MPP Trackers/Max. Input Current
| InfiniSolar WP II 30KW | 3 / 36A for each |
|---|---|
| InfiniSolar WP II 50KW | 4 / 36A for each |
MPP Voltage Range
| InfiniSolar WP II 30KW | 350 VDC ~ 900 VDC |
|---|---|
| InfiniSolar WP II 50KW | 350 VDC ~ 900 VDC |
Maximum DC Voltage
| InfiniSolar WP II 30KW | 1000 VDC |
|---|---|
| InfiniSolar WP II 50KW | 1000 VDC |
GRID OUTPUT (AC)
Nominal Output Current
| InfiniSolar WP II 30KW | 43.5 A per phase |
|---|---|
| InfiniSolar WP II 50KW | 73 A per phase |
Nominal Output Voltage
| InfiniSolar WP II 30KW | 230 VAC (P-N) / 400 VAC (P-P) |
|---|---|
| InfiniSolar WP II 50KW | 230 VAC (P-N) / 400 VAC (P-P) |
Output Voltage Range
| InfiniSolar WP II 30KW | 184 - 265 VAC per phase |
|---|---|
| InfiniSolar WP II 50KW | 184 - 265 VAC per phase |
AC INPUT
AC Start-up Voltage / Auto Restart Voltage
| InfiniSolar WP II 30KW | 120 - 140 VAC /180 VAC per phase |
|---|---|
| InfiniSolar WP II 50KW | 120 - 140 VAC /180 VAC per phase |
Acceptable Voltage Range
| InfiniSolar WP II 30KW | 170 - 280 VAC per phase |
|---|---|
| InfiniSolar WP II 50KW | 170 - 280 VAC per phase |
Maximum AC Input Current
| InfiniSolar WP II 30KW | 50 A |
|---|---|
| InfiniSolar WP II 50KW | 83 A |
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage
| InfiniSolar WP II 30KW | 230 VAC (P-N) / 400 VAC (P-P) |
|---|---|
| InfiniSolar WP II 50KW | 230 VAC (P-N) / 400 VAC (P-P) |
Efficiency (DC to AC)
| InfiniSolar WP II 30KW | 97% |
|---|---|
| InfiniSolar WP II 50KW | 97% |
BATTERY & CHARGER
Maximum Charging Current
| InfiniSolar WP II 30KW | 50 A |
|---|---|
| InfiniSolar WP II 50KW | 100 A |
Battery Voltage Range
| InfiniSolar WP II 30KW | 500 ~ 900 VDC |
|---|---|
| InfiniSolar WP II 50KW | 500 ~ 800 VDC |
GENERAL
PHYSICAL
Dimension, D X W X H (mm)
| InfiniSolar WP II 30KW | 290 x 580 x 900 |
|---|---|
| InfiniSolar WP II 50KW | 290 x 580 x 900 |
Net Weight (kgs)
| InfiniSolar WP II 30KW | 90 |
|---|---|
| InfiniSolar WP II 50KW | 90 |
INTERFACE
Communication Port
| InfiniSolar WP II 30KW | RS-232, USB, DRY CONTACT, RS-485, CAN,Wi-Fi |
|---|---|
| InfiniSolar WP II 50KW | RS-232, USB, DRY CONTACT, RS-485, CAN,Wi-Fi |
Intelligent Slot
| InfiniSolar WP II 30KW | Optional SNMP, Modbus |
|---|---|
| InfiniSolar WP II 50KW | Optional SNMP, Modbus |
ENVIRONMENT
Humidity
| InfiniSolar WP II 30KW | 0 ~ 100% RH (Non-condensing) |
|---|---|
| InfiniSolar WP II 50KW | 0 ~ 100% RH (Non-condensing) |
Operating Temperature
| InfiniSolar WP II 30KW | -25 to 60°C, > 45°C power derating |
|---|---|
| InfiniSolar WP II 50KW | -25 to 60°C, > 45°C power derating |
Altitude
| InfiniSolar WP II 30KW | 0 ~ 1000 m** |
|---|---|
| InfiniSolar WP II 50KW | 0 ~ 1000 m** |