295
InfiniSolar WP Elite
Hybrid inverter features IP65 rated enclosure
InfiniSolar WP Elite is applied with user-friendly HMI design & easy configuration. All important information is presented on the main screen and with just a few clicks, you can visualize all sorts of data to analyze how the inverter is doing!

Main Features
- • User-friendly HMI design and easy configuration
- • IP 65 waterproof and dustproof design
- • Dual output for smart load control
- • Two independent AC power sources connected and switched automatically
- • Built-in WiFi for mobile monitoring (App is available)
- • 150% unbalanced load support
- • User-adjustable charging current and voltage
- • Reserved communication port for BMS (RS485)
- • Parallel operation of up to 6 units
MODEL | InfiniSolar WP Elite 8KW | InfiniSolar WP Elite 10KW | InfiniSolar WP Elite 12KW | |
Maximum PV Input Power | 12000W | 15000W | 18000W | |
Rated Output Power | 8000 W | 10000 W | 12000 W | |
Maximum Charging Power | 8000 W | 10000 W | 12000 W | |
GRID-TIE OPERATION | ||||
PV INPUT (DC) | ||||
Nominal DC Voltage / Maximum DC Voltage | 720 VDC / 900 VDC | 720 VDC / 900 VDC | 720 VDC / 900 VDC | |
Start-up Voltage / Initial Feeding Voltage | 150 VDC / 150 VDC | 150 VDC / 150 VDC | 150 VDC / 150 VDC | |
Number of MPP Trackers/Max. Input Current | 2 / A: 15A, B: 15A | 2 / A: 18A, B: 18A | 2 / A: 27A, B: 27A | |
MPP Voltage Range | 150 VDC ~ 850 VDC | 150 VDC ~ 850 VDC | 150 VDC ~ 850 VDC | |
Full MPP Voltage Range | 400 VDC ~ 850 VDC | 420 VDC ~ 850 VDC | 400 VDC ~ 850 VDC | |
GRID OUTPUT (AC) | ||||
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | |
Output Voltage Range | 184 - 265 VAC per phase | 184 - 265 VAC per phase | 184 - 265 VAC per phase | |
Nominal Output Current | 11.6 A per phase | 14.5 A per phase | 17.4 A per phase | |
Power Factor | 0.9 lag ~ 0.9 lead | 0.9 lag ~ 0.9 lead | 0.9 lag ~ 0.9 lead | |
EFFICIENCY | ||||
Maximum Conversion Efficiency (DC/AC) | >96% | >96% | >96% | |
European Efficiency@ Vnominal | >95% | >95% | >95% | |
OFF-GRID OPERATION | ||||
AC INPUT | ||||
AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC per phase/180 VAC per phase | 120 - 140 VAC per phase/180 VAC per phase | 120 - 140 VAC per phase/180 VAC per phase | |
Acceptable Voltage Range | 170 - 290 VAC per phase | 170 - 290 VAC per phase | 170 - 290 VAC per phase | |
Maximum AC Input Current | 40 A | 40 A | 40 A | |
PV INPUT (DC) | ||||
Maximum DC Voltage | 900 VDC | 900 VDC | 900 VDC | |
Number of MPP Trackers/Max. Input Current | 2 / A: 15A, B: 15A | 2 / A: 18A, B: 18A | 2 / A: 18A, B: 18A | |
MPP Voltage Range | 150 VDC ~ 850 VDC | 150 VDC ~ 850 VDC | 150 VDC ~ 850 VDC | |
Full MPP Voltage Range | 400 VDC ~ 850 VDC | 420 VDC ~ 850 VDC | 400 VDC ~ 850 VDC | |
BATTERY MODE OUTPUT (AC) | ||||
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | |
Output Waveform | Pure sine wave | Pure sine wave | Pure sine wave | |
Efficiency (DC to AC) | >93% | >93% | >93% | |
HYBRID OPERATION | ||||
PV INPUT (DC) | ||||
Nominal DC Voltage / Maximum DC Voltage | 900 VDC | 900 VDC | 900 VDC | |
Start-up Voltage / Initial Feeding Voltage | 150 VDC / 150 VDC | 150 VDC / 150 VDC | 150 VDC / 150 VDC | |
Number of MPP Trackers/Max. Input Current | 2 / A: 15A, B: 15A | 2 / A: 18A, B: 18A | 2 / A: 18A, B: 18A | |
Full MPP Voltage Range | 400 VDC ~ 850 VDC | 420 VDC ~ 850 VDC | 400 VDC ~850 VDC | |
GRID OUTPUT (AC) | ||||
Nominal Output Current | 11.6 A per phase | 14.5 A per phase | 17.4 A per phase | |
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | |
Output Voltage Range | 184 - 265 VAC per phase | 184 - 265 VAC per phase | 184 - 265 VAC per phase | |
AC INPUT | ||||
AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC per phase/180 VAC per phase | 120 - 140 VAC per phase/180 VAC per phase | 120 - 140 VAC per phase/180 VAC per phase | |
Acceptable Voltage Range | 170 - 290 VAC per phase | 170 - 290 VAC per phase | 170 - 290 VAC per phase | |
Maximum AC Input Current | 40 A | 40 A | 40 A | |
BATTERY MODE OUTPUT (AC) | ||||
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | |
Efficiency (DC to AC) | >93% | >93% | >93% | |
BATTERY & CHARGER | ||||
Maximum Charging Current | 160 A | 200 A | 240 A | |
Battery Voltage Range | 40 ~ 60 VDC | 40 ~ 60 VDC | 40 ~ 60 VDC | |
Maximum Discharging Current | 200 A | 220 A | 250 A | |
GENERAL | ||||
PHYSICAL | ||||
Dimension, D X W X H (mm) | 247 x 500x 650 | 247 x 500x 650 | 247 x 500x 650 | |
Net Weight (kgs) | 50 | 50 | 54 | |
INTERFACE | ||||
Communication Port | RS-232, RS-485, USB, CAN and Wi-Fi | RS-232, RS-485, USB, CAN and Wi-Fi | RS-232, RS-485, USB, CAN and Wi-Fi | |
Intelligent Slot | Optional for SNMP and Modbus cards | Optional for SNMP and Modbus cards | Optional for SNMP and Modbus cards | |
ENVIRONMENT | ||||
Operating Humidity | 0 ~ 100% RH (Non-condensing) | 0 ~ 100% RH (Non-condensing) | 0 ~ 100% RH (Non-condensing) | |
Operating Temperature | -25 to 60°C, > 45°C power derating | -25 to 60°C, > 45°C power derating | -25 to 60°C, > 45°C power derating | |
Altitude | 0 ~ 1000 m** | 0 ~ 1000 m** | 0 ~ 1000 m** | |
Grid Connection Standard | NRS097-2-1:2017,VDE-AR-N4105 | NRS097-2-1:2017,VDE-AR-N4105 | NRS097-2-1:2017,VDE-AR-N4105 | |
PROTECTION&CERTIFICATE | ||||
Safety | IEC 62109,IEC 62116,IEC 61727,IEC 61683 | IEC 62109,IEC 62116,IEC 61727,IEC 61683 | IEC 62109,IEC 62116,IEC 61727,IEC 61683 |
MODEL
General
Maximum PV Input Power
InfiniSolar WP Elite 8KW | 12000W |
---|---|
InfiniSolar WP Elite 10KW | 15000W |
InfiniSolar WP Elite 12KW | 18000W |
Rated Output Power
InfiniSolar WP Elite 8KW | 8000 W |
---|---|
InfiniSolar WP Elite 10KW | 10000 W |
InfiniSolar WP Elite 12KW | 12000 W |
Maximum Charging Power
InfiniSolar WP Elite 8KW | 8000 W |
---|---|
InfiniSolar WP Elite 10KW | 10000 W |
InfiniSolar WP Elite 12KW | 12000 W |
GRID-TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage
InfiniSolar WP Elite 8KW | 720 VDC / 900 VDC |
---|---|
InfiniSolar WP Elite 10KW | 720 VDC / 900 VDC |
InfiniSolar WP Elite 12KW | 720 VDC / 900 VDC |
Start-up Voltage / Initial Feeding Voltage
InfiniSolar WP Elite 8KW | 150 VDC / 150 VDC |
---|---|
InfiniSolar WP Elite 10KW | 150 VDC / 150 VDC |
InfiniSolar WP Elite 12KW | 150 VDC / 150 VDC |
Number of MPP Trackers/Max. Input Current
InfiniSolar WP Elite 8KW | 2 / A: 15A, B: 15A |
---|---|
InfiniSolar WP Elite 10KW | 2 / A: 18A, B: 18A |
InfiniSolar WP Elite 12KW | 2 / A: 27A, B: 27A |
MPP Voltage Range
InfiniSolar WP Elite 8KW | 150 VDC ~ 850 VDC |
---|---|
InfiniSolar WP Elite 10KW | 150 VDC ~ 850 VDC |
InfiniSolar WP Elite 12KW | 150 VDC ~ 850 VDC |
Full MPP Voltage Range
InfiniSolar WP Elite 8KW | 400 VDC ~ 850 VDC |
---|---|
InfiniSolar WP Elite 10KW | 420 VDC ~ 850 VDC |
InfiniSolar WP Elite 12KW | 400 VDC ~ 850 VDC |
GRID OUTPUT (AC)
Nominal Output Voltage
InfiniSolar WP Elite 8KW | 230 VAC (P-N) / 400 VAC (P-P) |
---|---|
InfiniSolar WP Elite 10KW | 230 VAC (P-N) / 400 VAC (P-P) |
InfiniSolar WP Elite 12KW | 230 VAC (P-N) / 400 VAC (P-P) |
Output Voltage Range
InfiniSolar WP Elite 8KW | 184 - 265 VAC per phase |
---|---|
InfiniSolar WP Elite 10KW | 184 - 265 VAC per phase |
InfiniSolar WP Elite 12KW | 184 - 265 VAC per phase |
Nominal Output Current
InfiniSolar WP Elite 8KW | 11.6 A per phase |
---|---|
InfiniSolar WP Elite 10KW | 14.5 A per phase |
InfiniSolar WP Elite 12KW | 17.4 A per phase |
Power Factor
InfiniSolar WP Elite 8KW | 0.9 lag ~ 0.9 lead |
---|---|
InfiniSolar WP Elite 10KW | 0.9 lag ~ 0.9 lead |
InfiniSolar WP Elite 12KW | 0.9 lag ~ 0.9 lead |
EFFICIENCY
Maximum Conversion Efficiency (DC/AC)
InfiniSolar WP Elite 8KW | >96% |
---|---|
InfiniSolar WP Elite 10KW | >96% |
InfiniSolar WP Elite 12KW | >96% |
European Efficiency@ Vnominal
InfiniSolar WP Elite 8KW | >95% |
---|---|
InfiniSolar WP Elite 10KW | >95% |
InfiniSolar WP Elite 12KW | >95% |
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage / Auto Restart Voltage
InfiniSolar WP Elite 8KW | 120 - 140 VAC per phase/180 VAC per phase |
---|---|
InfiniSolar WP Elite 10KW | 120 - 140 VAC per phase/180 VAC per phase |
InfiniSolar WP Elite 12KW | 120 - 140 VAC per phase/180 VAC per phase |
Acceptable Voltage Range
InfiniSolar WP Elite 8KW | 170 - 290 VAC per phase |
---|---|
InfiniSolar WP Elite 10KW | 170 - 290 VAC per phase |
InfiniSolar WP Elite 12KW | 170 - 290 VAC per phase |
Maximum AC Input Current
InfiniSolar WP Elite 8KW | 40 A |
---|---|
InfiniSolar WP Elite 10KW | 40 A |
InfiniSolar WP Elite 12KW | 40 A |
PV INPUT (DC)
Maximum DC Voltage
InfiniSolar WP Elite 8KW | 900 VDC |
---|---|
InfiniSolar WP Elite 10KW | 900 VDC |
InfiniSolar WP Elite 12KW | 900 VDC |
Number of MPP Trackers/Max. Input Current
InfiniSolar WP Elite 8KW | 2 / A: 15A, B: 15A |
---|---|
InfiniSolar WP Elite 10KW | 2 / A: 18A, B: 18A |
InfiniSolar WP Elite 12KW | 2 / A: 18A, B: 18A |
MPP Voltage Range
InfiniSolar WP Elite 8KW | 150 VDC ~ 850 VDC |
---|---|
InfiniSolar WP Elite 10KW | 150 VDC ~ 850 VDC |
InfiniSolar WP Elite 12KW | 150 VDC ~ 850 VDC |
Full MPP Voltage Range
InfiniSolar WP Elite 8KW | 400 VDC ~ 850 VDC |
---|---|
InfiniSolar WP Elite 10KW | 420 VDC ~ 850 VDC |
InfiniSolar WP Elite 12KW | 400 VDC ~ 850 VDC |
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage
InfiniSolar WP Elite 8KW | 230 VAC (P-N) / 400 VAC (P-P) |
---|---|
InfiniSolar WP Elite 10KW | 230 VAC (P-N) / 400 VAC (P-P) |
InfiniSolar WP Elite 12KW | 230 VAC (P-N) / 400 VAC (P-P) |
Output Waveform
InfiniSolar WP Elite 8KW | Pure sine wave |
---|---|
InfiniSolar WP Elite 10KW | Pure sine wave |
InfiniSolar WP Elite 12KW | Pure sine wave |
Efficiency (DC to AC)
InfiniSolar WP Elite 8KW | >93% |
---|---|
InfiniSolar WP Elite 10KW | >93% |
InfiniSolar WP Elite 12KW | >93% |
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage
InfiniSolar WP Elite 8KW | 900 VDC |
---|---|
InfiniSolar WP Elite 10KW | 900 VDC |
InfiniSolar WP Elite 12KW | 900 VDC |
Start-up Voltage / Initial Feeding Voltage
InfiniSolar WP Elite 8KW | 150 VDC / 150 VDC |
---|---|
InfiniSolar WP Elite 10KW | 150 VDC / 150 VDC |
InfiniSolar WP Elite 12KW | 150 VDC / 150 VDC |
Number of MPP Trackers/Max. Input Current
InfiniSolar WP Elite 8KW | 2 / A: 15A, B: 15A |
---|---|
InfiniSolar WP Elite 10KW | 2 / A: 18A, B: 18A |
InfiniSolar WP Elite 12KW | 2 / A: 18A, B: 18A |
Full MPP Voltage Range
InfiniSolar WP Elite 8KW | 400 VDC ~ 850 VDC |
---|---|
InfiniSolar WP Elite 10KW | 420 VDC ~ 850 VDC |
InfiniSolar WP Elite 12KW | 400 VDC ~850 VDC |
GRID OUTPUT (AC)
Nominal Output Current
InfiniSolar WP Elite 8KW | 11.6 A per phase |
---|---|
InfiniSolar WP Elite 10KW | 14.5 A per phase |
InfiniSolar WP Elite 12KW | 17.4 A per phase |
Nominal Output Voltage
InfiniSolar WP Elite 8KW | 230 VAC (P-N) / 400 VAC (P-P) |
---|---|
InfiniSolar WP Elite 10KW | 230 VAC (P-N) / 400 VAC (P-P) |
InfiniSolar WP Elite 12KW | 230 VAC (P-N) / 400 VAC (P-P) |
Output Voltage Range
InfiniSolar WP Elite 8KW | 184 - 265 VAC per phase |
---|---|
InfiniSolar WP Elite 10KW | 184 - 265 VAC per phase |
InfiniSolar WP Elite 12KW | 184 - 265 VAC per phase |
AC INPUT
AC Start-up Voltage / Auto Restart Voltage
InfiniSolar WP Elite 8KW | 120 - 140 VAC per phase/180 VAC per phase |
---|---|
InfiniSolar WP Elite 10KW | 120 - 140 VAC per phase/180 VAC per phase |
InfiniSolar WP Elite 12KW | 120 - 140 VAC per phase/180 VAC per phase |
Acceptable Voltage Range
InfiniSolar WP Elite 8KW | 170 - 290 VAC per phase |
---|---|
InfiniSolar WP Elite 10KW | 170 - 290 VAC per phase |
InfiniSolar WP Elite 12KW | 170 - 290 VAC per phase |
Maximum AC Input Current
InfiniSolar WP Elite 8KW | 40 A |
---|---|
InfiniSolar WP Elite 10KW | 40 A |
InfiniSolar WP Elite 12KW | 40 A |
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage
InfiniSolar WP Elite 8KW | 230 VAC (P-N) / 400 VAC (P-P) |
---|---|
InfiniSolar WP Elite 10KW | 230 VAC (P-N) / 400 VAC (P-P) |
InfiniSolar WP Elite 12KW | 230 VAC (P-N) / 400 VAC (P-P) |
Efficiency (DC to AC)
InfiniSolar WP Elite 8KW | >93% |
---|---|
InfiniSolar WP Elite 10KW | >93% |
InfiniSolar WP Elite 12KW | >93% |
BATTERY & CHARGER
Maximum Charging Current
InfiniSolar WP Elite 8KW | 160 A |
---|---|
InfiniSolar WP Elite 10KW | 200 A |
InfiniSolar WP Elite 12KW | 240 A |
Battery Voltage Range
InfiniSolar WP Elite 8KW | 40 ~ 60 VDC |
---|---|
InfiniSolar WP Elite 10KW | 40 ~ 60 VDC |
InfiniSolar WP Elite 12KW | 40 ~ 60 VDC |
Maximum Discharging Current
InfiniSolar WP Elite 8KW | 200 A |
---|---|
InfiniSolar WP Elite 10KW | 220 A |
InfiniSolar WP Elite 12KW | 250 A |
GENERAL
PHYSICAL
Dimension, D X W X H (mm)
InfiniSolar WP Elite 8KW | 247 x 500x 650 |
---|---|
InfiniSolar WP Elite 10KW | 247 x 500x 650 |
InfiniSolar WP Elite 12KW | 247 x 500x 650 |
Net Weight (kgs)
InfiniSolar WP Elite 8KW | 50 |
---|---|
InfiniSolar WP Elite 10KW | 50 |
InfiniSolar WP Elite 12KW | 54 |
INTERFACE
Communication Port
InfiniSolar WP Elite 8KW | RS-232, RS-485, USB, CAN and Wi-Fi |
---|---|
InfiniSolar WP Elite 10KW | RS-232, RS-485, USB, CAN and Wi-Fi |
InfiniSolar WP Elite 12KW | RS-232, RS-485, USB, CAN and Wi-Fi |
Intelligent Slot
InfiniSolar WP Elite 8KW | Optional for SNMP and Modbus cards |
---|---|
InfiniSolar WP Elite 10KW | Optional for SNMP and Modbus cards |
InfiniSolar WP Elite 12KW | Optional for SNMP and Modbus cards |
ENVIRONMENT
Operating Humidity
InfiniSolar WP Elite 8KW | 0 ~ 100% RH (Non-condensing) |
---|---|
InfiniSolar WP Elite 10KW | 0 ~ 100% RH (Non-condensing) |
InfiniSolar WP Elite 12KW | 0 ~ 100% RH (Non-condensing) |
Operating Temperature
InfiniSolar WP Elite 8KW | -25 to 60°C, > 45°C power derating |
---|---|
InfiniSolar WP Elite 10KW | -25 to 60°C, > 45°C power derating |
InfiniSolar WP Elite 12KW | -25 to 60°C, > 45°C power derating |
Altitude
InfiniSolar WP Elite 8KW | 0 ~ 1000 m** |
---|---|
InfiniSolar WP Elite 10KW | 0 ~ 1000 m** |
InfiniSolar WP Elite 12KW | 0 ~ 1000 m** |
Grid Connection Standard
InfiniSolar WP Elite 8KW | NRS097-2-1:2017,VDE-AR-N4105 |
---|---|
InfiniSolar WP Elite 10KW | NRS097-2-1:2017,VDE-AR-N4105 |
InfiniSolar WP Elite 12KW | NRS097-2-1:2017,VDE-AR-N4105 |
PROTECTION&CERTIFICATE
Safety
InfiniSolar WP Elite 8KW | IEC 62109,IEC 62116,IEC 61727,IEC 61683 |
---|---|
InfiniSolar WP Elite 10KW | IEC 62109,IEC 62116,IEC 61727,IEC 61683 |
InfiniSolar WP Elite 12KW | IEC 62109,IEC 62116,IEC 61727,IEC 61683 |
![]() |
Brochure | InfiniSolar WP Elite |
On-Grid with Energy-Storage Inverter InfiniSolar WP Elite Hybrid inverter features IP65 rated enclosure
Related Products