Giant iND II 3P/1P 384VDC 10KVA-80KVA
Patented chassis structure offers 100% front access
Giant iND II is a 3-Phase Online UPS with IP31-rated protection and outstanding heat dissipation performance for industrial and harsh environments by applying advanced graphene coating Hi-tech components. Moreover, Giant iND II designed with a patented chassis structure offers 100% front access to allow easy maintenance and wiring for input, output, and periodically replacing components.
Main Features
- Patented chassis structure offers 100% front access
- Applied advanced graphene coating with industrial-grade components for effective heat dissipation
- Standard IP31 protection, optional IP42 kit to withstand harsh environment
- International brands of key components with component lifecycle management for extended product lifecycle
- Redundant design to guarantee product reliability
- Parallel capability up to 4 units
- Temperature compensation to prolong battery life
- Backfeed protection and in-built 40kA surge protection guarantee safety operation
- 7”colored LCD with customized control setting and accessible informative data of the UPS
| MODEL | Giant iND II 31-10K | Giant iND II 31-20K | Giant iND II 31-30K | Giant iND II 31-40K | Giant iND II 31-60K | Giant iND II 31-80K | |
| CAPACITY | 10KVA/8KW | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 60KVA/48KW | 80KVA/64KW | |
| INPUT | |||||||
| Nominal Voltage | 380VAC/400VAC/415VAC | 380VAC/400VAC/415VAC | 380VAC/400VAC/415VAC | 380VAC/400VAC/415VAC | 380VAC/400VAC/415VAC | 380VAC/400VAC/415VAC | |
| Acceptable Voltage Range | 304VAC ~ 456VAC | 304VAC ~ 456VAC | 304VAC ~ 456VAC | 304VAC ~ 456VAC | 304VAC ~ 456VAC | 304VAC ~ 456VAC | |
| Frequency | 50Hz/60Hz ± 10% | 50Hz/60Hz ± 10% | 50Hz/60Hz ± 10% | 50Hz/60Hz ± 10% | 50Hz/60Hz ± 10% | 50Hz/60Hz ± 10% | |
| Rectifier Type | 6 pulse | 6 pulse | 6 pulse | 6 pulse | 6 pulse | 6 pulse | |
| Main Input and Bypass Input | Supports dual inputs | Supports dual inputs | Supports dual inputs | Supports dual inputs | Supports dual inputs | Supports dual inputs | |
| TVSS | 40kA | 40kA | 40kA | 40kA | 40kA | 40kA | |
| OUTPUT | |||||||
| Overload Capability | 110% continuous running; 125% for 10 min; >150% for 1 min | 110% continuous running; 125% for 10 min; >150% for 1 min | 110% continuous running; 125% for 10 min; >150% for 1 min | 110% continuous running; 125% for 10 min; >150% for 1 min | 110% continuous running; 125% for 10 min; >150% for 1 min | 110% continuous running; 125% for 10 min; >150% for 1 min | |
| Frequency | 50Hz/60Hz ± 1% | 50Hz/60Hz ± 1% | 50Hz/60Hz ± 1% | 50Hz/60Hz ± 1% | 50Hz/60Hz ± 1% | 50Hz/60Hz ± 1% | |
| Power Factor | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | |
| Nominal Output Voltage | 220VAC/230VAC/240VAC | 220VAC/230VAC/240VAC | 220VAC/230VAC/240VAC | 220VAC/230VAC/240VAC | 220VAC/230VAC/240VAC | 220VAC/230VAC/240VAC | |
| Output Voltage Regulation | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |
| BYPASS | |||||||
| Input Voltage Range | 165VAC ~ 275VAC | 165VAC ~ 275VAC | 165VAC ~ 275VAC | 165VAC ~ 275VAC | 165VAC ~ 275VAC | 165VAC ~ 275VAC | |
| Nominal Voltage | 220VAC | 220VAC | 220VAC | 220VAC | 220VAC | 220VAC | |
| BATTERY | |||||||
| Battery Voltage | 384VDC (Adjustable) | 384VDC (Adjustable) | 384VDC (Adjustable) | 384VDC (Adjustable) | 384VDC (Adjustable) | 384VDC (Adjustable) | |
| Cold Start | Yes | Yes | Yes | Yes | Yes | Yes | |
| ENVIRONMENT | |||||||
| Altitude | 1000m | 1000m | 1000m | 1000m | 1000m | 1000m | |
| Operating Temperature | 0~ 40°C | 0~ 40°C | 0~ 40°C | 0~ 40°C | 0~ 40°C | 0~ 40°C | |
| Humidity | 0~95% (non-condensing) | 0~95% (non-condensing) | 0~95% (non-condensing) | 0~95% (non-condensing) | 0~95% (non-condensing) | 0~95% (non-condensing) | |
| Storage Temperature | -25°C ~ 55°C | -25°C ~ 55°C | -25°C ~ 55°C | -25°C ~ 55°C | -25°C ~ 55°C | -25°C ~ 55°C | |
| PHYSICAL | |||||||
| Net Weight (Kgs) | 285 | 319 | 337 | 387 | 468 | 523 | |
| IP Protection | IP31 (default);IP42 (Option) | IP31 (default);IP42 (Option) | IP31 (default);IP42 (Option) | IP31 (default);IP42 (Option) | IP31 (default);IP42 (Option) | IP31 (default);IP42 (Option) | |
| Dimensions, D x W x H(mm) | 800 x 800 x 1800 | 800 x 800 x 1800 | 800 x 800 x 1800 | 800 x 800 x 1800 | 800 x 800 x 1800 | 800 x 800 x 1800 | |
| MANAGEMENT | |||||||
| Optional SNMP | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | |
| Modbus RS-232 / RS485 | Supports Windows® family, Linux and MAC | Supports Windows® family, Linux and MAC | Supports Windows® family, Linux and MAC | Supports Windows® family, Linux and MAC | Supports Windows® family, Linux and MAC | Supports Windows® family, Linux and MAC | |
| Dry Contacts | 5 outputs and 4 inputs | 5 outputs and 4 inputs | 5 outputs and 4 inputs | 5 outputs and 4 inputs | 5 outputs and 4 inputs | 5 outputs and 4 inputs | |
| STANDARD | |||||||
| Safety | IEC62040-1-2017 | IEC62040-1-2017 | IEC62040-1-2017 | IEC62040-1-2017 | IEC62040-1-2017 | IEC62040-1-2017 | |
| EMC Immunity | IEC61000-4-5 | IEC61000-4-5 | IEC61000-4-5 | IEC61000-4-5 | IEC61000-4-5 | IEC61000-4-5 | |
| EMC Emissions | IEC62040-2-2018 | IEC62040-2-2018 | IEC62040-2-2018 | IEC62040-2-2018 | IEC62040-2-2018 | IEC62040-2-2018 | |
| Approvals | CE / CB/ Conformance testing / EMC / ROHS2 / Reach / YDT1095-2018 | CE / CB/ Conformance testing / EMC / ROHS2 / Reach / YDT1095-2018 | CE / CB/ Conformance testing / EMC / ROHS2 / Reach / YDT1095-2018 | CE / CB/ Conformance testing / EMC / ROHS2 / Reach / YDT1095-2018 | CE / CB/ Conformance testing / EMC / ROHS2 / Reach / YDT1095-2018 | CE / CB/ Conformance testing / EMC / ROHS2 / Reach / YDT1095-2018 | |
General
CAPACITY
| Giant iND II 31-10K | 10KVA/8KW |
|---|---|
| Giant iND II 31-20K | 20KVA/16KW |
| Giant iND II 31-30K | 30KVA/24KW |
| Giant iND II 31-40K | 40KVA/32KW |
| Giant iND II 31-60K | 60KVA/48KW |
| Giant iND II 31-80K | 80KVA/64KW |
INPUT
Nominal Voltage
| Giant iND II 31-10K | 380VAC/400VAC/415VAC |
|---|---|
| Giant iND II 31-20K | 380VAC/400VAC/415VAC |
| Giant iND II 31-30K | 380VAC/400VAC/415VAC |
| Giant iND II 31-40K | 380VAC/400VAC/415VAC |
| Giant iND II 31-60K | 380VAC/400VAC/415VAC |
| Giant iND II 31-80K | 380VAC/400VAC/415VAC |
Acceptable Voltage Range
| Giant iND II 31-10K | 304VAC ~ 456VAC |
|---|---|
| Giant iND II 31-20K | 304VAC ~ 456VAC |
| Giant iND II 31-30K | 304VAC ~ 456VAC |
| Giant iND II 31-40K | 304VAC ~ 456VAC |
| Giant iND II 31-60K | 304VAC ~ 456VAC |
| Giant iND II 31-80K | 304VAC ~ 456VAC |
Frequency
| Giant iND II 31-10K | 50Hz/60Hz ± 10% |
|---|---|
| Giant iND II 31-20K | 50Hz/60Hz ± 10% |
| Giant iND II 31-30K | 50Hz/60Hz ± 10% |
| Giant iND II 31-40K | 50Hz/60Hz ± 10% |
| Giant iND II 31-60K | 50Hz/60Hz ± 10% |
| Giant iND II 31-80K | 50Hz/60Hz ± 10% |
Rectifier Type
| Giant iND II 31-10K | 6 pulse |
|---|---|
| Giant iND II 31-20K | 6 pulse |
| Giant iND II 31-30K | 6 pulse |
| Giant iND II 31-40K | 6 pulse |
| Giant iND II 31-60K | 6 pulse |
| Giant iND II 31-80K | 6 pulse |
Main Input and Bypass Input
| Giant iND II 31-10K | Supports dual inputs |
|---|---|
| Giant iND II 31-20K | Supports dual inputs |
| Giant iND II 31-30K | Supports dual inputs |
| Giant iND II 31-40K | Supports dual inputs |
| Giant iND II 31-60K | Supports dual inputs |
| Giant iND II 31-80K | Supports dual inputs |
TVSS
| Giant iND II 31-10K | 40kA |
|---|---|
| Giant iND II 31-20K | 40kA |
| Giant iND II 31-30K | 40kA |
| Giant iND II 31-40K | 40kA |
| Giant iND II 31-60K | 40kA |
| Giant iND II 31-80K | 40kA |
OUTPUT
Overload Capability
| Giant iND II 31-10K | 110% continuous running; 125% for 10 min; >150% for 1 min |
|---|---|
| Giant iND II 31-20K | 110% continuous running; 125% for 10 min; >150% for 1 min |
| Giant iND II 31-30K | 110% continuous running; 125% for 10 min; >150% for 1 min |
| Giant iND II 31-40K | 110% continuous running; 125% for 10 min; >150% for 1 min |
| Giant iND II 31-60K | 110% continuous running; 125% for 10 min; >150% for 1 min |
| Giant iND II 31-80K | 110% continuous running; 125% for 10 min; >150% for 1 min |
Frequency
| Giant iND II 31-10K | 50Hz/60Hz ± 1% |
|---|---|
| Giant iND II 31-20K | 50Hz/60Hz ± 1% |
| Giant iND II 31-30K | 50Hz/60Hz ± 1% |
| Giant iND II 31-40K | 50Hz/60Hz ± 1% |
| Giant iND II 31-60K | 50Hz/60Hz ± 1% |
| Giant iND II 31-80K | 50Hz/60Hz ± 1% |
Power Factor
| Giant iND II 31-10K | 0.8 |
|---|---|
| Giant iND II 31-20K | 0.8 |
| Giant iND II 31-30K | 0.8 |
| Giant iND II 31-40K | 0.8 |
| Giant iND II 31-60K | 0.8 |
| Giant iND II 31-80K | 0.8 |
Nominal Output Voltage
| Giant iND II 31-10K | 220VAC/230VAC/240VAC |
|---|---|
| Giant iND II 31-20K | 220VAC/230VAC/240VAC |
| Giant iND II 31-30K | 220VAC/230VAC/240VAC |
| Giant iND II 31-40K | 220VAC/230VAC/240VAC |
| Giant iND II 31-60K | 220VAC/230VAC/240VAC |
| Giant iND II 31-80K | 220VAC/230VAC/240VAC |
Output Voltage Regulation
| Giant iND II 31-10K | ±1% |
|---|---|
| Giant iND II 31-20K | ±1% |
| Giant iND II 31-30K | ±1% |
| Giant iND II 31-40K | ±1% |
| Giant iND II 31-60K | ±1% |
| Giant iND II 31-80K | ±1% |
BYPASS
Input Voltage Range
| Giant iND II 31-10K | 165VAC ~ 275VAC |
|---|---|
| Giant iND II 31-20K | 165VAC ~ 275VAC |
| Giant iND II 31-30K | 165VAC ~ 275VAC |
| Giant iND II 31-40K | 165VAC ~ 275VAC |
| Giant iND II 31-60K | 165VAC ~ 275VAC |
| Giant iND II 31-80K | 165VAC ~ 275VAC |
Nominal Voltage
| Giant iND II 31-10K | 220VAC |
|---|---|
| Giant iND II 31-20K | 220VAC |
| Giant iND II 31-30K | 220VAC |
| Giant iND II 31-40K | 220VAC |
| Giant iND II 31-60K | 220VAC |
| Giant iND II 31-80K | 220VAC |
BATTERY
Battery Voltage
| Giant iND II 31-10K | 384VDC (Adjustable) |
|---|---|
| Giant iND II 31-20K | 384VDC (Adjustable) |
| Giant iND II 31-30K | 384VDC (Adjustable) |
| Giant iND II 31-40K | 384VDC (Adjustable) |
| Giant iND II 31-60K | 384VDC (Adjustable) |
| Giant iND II 31-80K | 384VDC (Adjustable) |
Cold Start
| Giant iND II 31-10K | Yes |
|---|---|
| Giant iND II 31-20K | Yes |
| Giant iND II 31-30K | Yes |
| Giant iND II 31-40K | Yes |
| Giant iND II 31-60K | Yes |
| Giant iND II 31-80K | Yes |
ENVIRONMENT
Altitude
| Giant iND II 31-10K | 1000m |
|---|---|
| Giant iND II 31-20K | 1000m |
| Giant iND II 31-30K | 1000m |
| Giant iND II 31-40K | 1000m |
| Giant iND II 31-60K | 1000m |
| Giant iND II 31-80K | 1000m |
Operating Temperature
| Giant iND II 31-10K | 0~ 40°C |
|---|---|
| Giant iND II 31-20K | 0~ 40°C |
| Giant iND II 31-30K | 0~ 40°C |
| Giant iND II 31-40K | 0~ 40°C |
| Giant iND II 31-60K | 0~ 40°C |
| Giant iND II 31-80K | 0~ 40°C |
Humidity
| Giant iND II 31-10K | 0~95% (non-condensing) |
|---|---|
| Giant iND II 31-20K | 0~95% (non-condensing) |
| Giant iND II 31-30K | 0~95% (non-condensing) |
| Giant iND II 31-40K | 0~95% (non-condensing) |
| Giant iND II 31-60K | 0~95% (non-condensing) |
| Giant iND II 31-80K | 0~95% (non-condensing) |
Storage Temperature
| Giant iND II 31-10K | -25°C ~ 55°C |
|---|---|
| Giant iND II 31-20K | -25°C ~ 55°C |
| Giant iND II 31-30K | -25°C ~ 55°C |
| Giant iND II 31-40K | -25°C ~ 55°C |
| Giant iND II 31-60K | -25°C ~ 55°C |
| Giant iND II 31-80K | -25°C ~ 55°C |
PHYSICAL
Net Weight (Kgs)
| Giant iND II 31-10K | 285 |
|---|---|
| Giant iND II 31-20K | 319 |
| Giant iND II 31-30K | 337 |
| Giant iND II 31-40K | 387 |
| Giant iND II 31-60K | 468 |
| Giant iND II 31-80K | 523 |
IP Protection
| Giant iND II 31-10K | IP31 (default);IP42 (Option) |
|---|---|
| Giant iND II 31-20K | IP31 (default);IP42 (Option) |
| Giant iND II 31-30K | IP31 (default);IP42 (Option) |
| Giant iND II 31-40K | IP31 (default);IP42 (Option) |
| Giant iND II 31-60K | IP31 (default);IP42 (Option) |
| Giant iND II 31-80K | IP31 (default);IP42 (Option) |
Dimensions, D x W x H(mm)
| Giant iND II 31-10K | 800 x 800 x 1800 |
|---|---|
| Giant iND II 31-20K | 800 x 800 x 1800 |
| Giant iND II 31-30K | 800 x 800 x 1800 |
| Giant iND II 31-40K | 800 x 800 x 1800 |
| Giant iND II 31-60K | 800 x 800 x 1800 |
| Giant iND II 31-80K | 800 x 800 x 1800 |
MANAGEMENT
Optional SNMP
| Giant iND II 31-10K | Power management from SNMP manager and web browser |
|---|---|
| Giant iND II 31-20K | Power management from SNMP manager and web browser |
| Giant iND II 31-30K | Power management from SNMP manager and web browser |
| Giant iND II 31-40K | Power management from SNMP manager and web browser |
| Giant iND II 31-60K | Power management from SNMP manager and web browser |
| Giant iND II 31-80K | Power management from SNMP manager and web browser |
Modbus RS-232 / RS485
| Giant iND II 31-10K | Supports Windows® family, Linux and MAC |
|---|---|
| Giant iND II 31-20K | Supports Windows® family, Linux and MAC |
| Giant iND II 31-30K | Supports Windows® family, Linux and MAC |
| Giant iND II 31-40K | Supports Windows® family, Linux and MAC |
| Giant iND II 31-60K | Supports Windows® family, Linux and MAC |
| Giant iND II 31-80K | Supports Windows® family, Linux and MAC |
Dry Contacts
| Giant iND II 31-10K | 5 outputs and 4 inputs |
|---|---|
| Giant iND II 31-20K | 5 outputs and 4 inputs |
| Giant iND II 31-30K | 5 outputs and 4 inputs |
| Giant iND II 31-40K | 5 outputs and 4 inputs |
| Giant iND II 31-60K | 5 outputs and 4 inputs |
| Giant iND II 31-80K | 5 outputs and 4 inputs |
STANDARD
Safety
| Giant iND II 31-10K | IEC62040-1-2017 |
|---|---|
| Giant iND II 31-20K | IEC62040-1-2017 |
| Giant iND II 31-30K | IEC62040-1-2017 |
| Giant iND II 31-40K | IEC62040-1-2017 |
| Giant iND II 31-60K | IEC62040-1-2017 |
| Giant iND II 31-80K | IEC62040-1-2017 |
EMC Immunity
| Giant iND II 31-10K | IEC61000-4-5 |
|---|---|
| Giant iND II 31-20K | IEC61000-4-5 |
| Giant iND II 31-30K | IEC61000-4-5 |
| Giant iND II 31-40K | IEC61000-4-5 |
| Giant iND II 31-60K | IEC61000-4-5 |
| Giant iND II 31-80K | IEC61000-4-5 |
EMC Emissions
| Giant iND II 31-10K | IEC62040-2-2018 |
|---|---|
| Giant iND II 31-20K | IEC62040-2-2018 |
| Giant iND II 31-30K | IEC62040-2-2018 |
| Giant iND II 31-40K | IEC62040-2-2018 |
| Giant iND II 31-60K | IEC62040-2-2018 |
| Giant iND II 31-80K | IEC62040-2-2018 |
Approvals
| Giant iND II 31-10K | CE / CB/ Conformance testing / EMC / ROHS2 / Reach / YDT1095-2018 |
|---|---|
| Giant iND II 31-20K | CE / CB/ Conformance testing / EMC / ROHS2 / Reach / YDT1095-2018 |
| Giant iND II 31-30K | CE / CB/ Conformance testing / EMC / ROHS2 / Reach / YDT1095-2018 |
| Giant iND II 31-40K | CE / CB/ Conformance testing / EMC / ROHS2 / Reach / YDT1095-2018 |
| Giant iND II 31-60K | CE / CB/ Conformance testing / EMC / ROHS2 / Reach / YDT1095-2018 |
| Giant iND II 31-80K | CE / CB/ Conformance testing / EMC / ROHS2 / Reach / YDT1095-2018 |
| Brochure | Giant iND II Brochure | |
| Manual | Giant iND II 3P/1P 10KVA-80KVA |
Three phase - Online UPS Giant iND II 3P/1P 384VDC 10KVA-80KVA Patented chassis structure offers 100% front access
Related Products