Giant Elite 3P/1P 6K/7.5K/10KVA
Embedded with isolation transformer
Embedded with isolation transformer, Giant series will eliminate common mode noise and the need to install expensive dedicated circuits. It provides reliable galvanically isolated power to critical equipment.
Main Features
  • Galvanic isolation design to withstand all kinds of loads
  • Output power factor 0.8
  • Fully coating PCBAs to withstand harsh environment
  • Unique ventilation design for effective heat dissipation
  • Wide input voltage and frequency range to withstand robust environment
  • High short-circuit and overload capabilities
  • Built-in maintenance bypass switch
General
CAPACITY
Giant Elite 31-6K(L)6 KVA / 4.8 KW
Giant Elite 31-7.5K(L)7.5 KVA / 6 KW
Giant Elite 31-10K(L)10 KVA / 8 KW
PHASE
Giant Elite 31-6K(L)3-phase in / 1-phase out
Giant Elite 31-7.5K(L)3-phase in / 1-phase out
Giant Elite 31-10K(L)3-phase in / 1-phase out
INPUT
Nominal Voltage
Giant Elite 31-6K(L)3 x 360VAC/380VAC/400VAC (3Ph + N + G)
Giant Elite 31-7.5K(L)3 x 360VAC/380VAC/400VAC (3Ph + N + G)
Giant Elite 31-10K(L)3 x 360VAC/380VAC/400VAC (3Ph + N + G)
Acceptable Voltage Range
Giant Elite 31-6K(L)286VAC~493VAC @ 16 pcs of batteries; 320VAC~493VAC @ 18 pcs of batteries
Giant Elite 31-7.5K(L)286VAC~493VAC @ 16 pcs of batteries; 320VAC~493VAC @ 18 pcs of batteries
Giant Elite 31-10K(L)286VAC~493VAC @ 16 pcs of batteries; 320VAC~493VAC @ 18 pcs of batteries
Frequency
Giant Elite 31-6K(L)40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system
Giant Elite 31-7.5K(L)40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system
Giant Elite 31-10K(L)40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system
OUTPUT
Voltage Regulation
Giant Elite 31-6K(L)± 1%
Giant Elite 31-7.5K(L)± 1%
Giant Elite 31-10K(L)± 1%
Output Voltage
Giant Elite 31-6K(L)208VAC/220VAC/230VAC (Selectable)
Giant Elite 31-7.5K(L)208VAC/220VAC/230VAC (Selectable)
Giant Elite 31-10K(L)208VAC/220VAC/230VAC (Selectable)
Frequency Range (Batt. Mode)
Giant Elite 31-6K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Giant Elite 31-7.5K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Giant Elite 31-10K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Transfer Time AC to DC
Giant Elite 31-6K(L)Zero
Giant Elite 31-7.5K(L)Zero
Giant Elite 31-10K(L)Zero
Transfer Time Inverter to Bypass
Giant Elite 31-6K(L)Zero
Giant Elite 31-7.5K(L)Zero
Giant Elite 31-10K(L)Zero
Transfer Time Waveform (Batt. Mode)
Giant Elite 31-6K(L)Pure Sine Wave
Giant Elite 31-7.5K(L)Pure Sine Wave
Giant Elite 31-10K(L)Pure Sine Wave
Efficiency Battery Mode
Giant Elite 31-6K(L)92%
Giant Elite 31-7.5K(L)92%
Giant Elite 31-10K(L)92%
Efficiency Line Mode
Giant Elite 31-6K(L)83%
Giant Elite 31-7.5K(L)83%
Giant Elite 31-10K(L)83%
Frequency Range
Giant Elite 31-6K(L)45Hz~55 Hz or 56 Hz~64 Hz
Giant Elite 31-7.5K(L)45Hz~55 Hz or 56 Hz~64 Hz
Giant Elite 31-10K(L)45Hz~55 Hz or 56 Hz~64 Hz
Current Crest Ratio
Giant Elite 31-6K(L)3:1
Giant Elite 31-7.5K(L)3:1
Giant Elite 31-10K(L)3:1
Harmonic Distortion
Giant Elite 31-6K(L)<3% THD (Linear Load); <5% THD (Non-linear Load)
Giant Elite 31-7.5K(L)<3% THD (Linear Load); <5% THD (Non-linear Load)
Giant Elite 31-10K(L)<3% THD (Linear Load); <5% THD (Non-linear Load)
BATTERY
Long-run Model Battery Numbers
Giant Elite 31-6K(L)16pcs, 18 pcs
Giant Elite 31-7.5K(L)16pcs, 18 pcs
Giant Elite 31-10K(L)16pcs, 18 pcs
Long-run Model Battery Type
Giant Elite 31-6K(L)Depending on the applications
Giant Elite 31-7.5K(L)Depending on the applications
Giant Elite 31-10K(L)Depending on the applications
Long-run Model Charging Current (max.)
Giant Elite 31-6K(L)Default: 8A, 2A/4A/8A(adjustable)
Giant Elite 31-7.5K(L)Default: 8A, 2A/4A/8A(adjustable)
Giant Elite 31-10K(L)Default: 8A, 2A/4A/8A(adjustable)
Long-run Model Charging Voltage
Giant Elite 31-6K(L)218.4 V ± 1%, 245.7 V ± 1%
Giant Elite 31-7.5K(L)218.4 V ± 1%, 245.7 V ± 1%
Giant Elite 31-10K(L)218.4 V ± 1%, 245.7 V ± 1%
Standard Model Battery Numbers
Giant Elite 31-6K(L)16pcs
Giant Elite 31-7.5K(L)16pcs
Giant Elite 31-10K(L)16pcs
Standard Model Battery Type
Giant Elite 31-6K(L)12V / 9Ah
Giant Elite 31-7.5K(L)12V / 9Ah
Giant Elite 31-10K(L)12V / 9Ah
Standard Model Charging Current (max.)
Giant Elite 31-6K(L)2A
Giant Elite 31-7.5K(L)2A
Giant Elite 31-10K(L)2A
Standard Model Charging Voltage
Giant Elite 31-6K(L)218.4 V ± 1%
Giant Elite 31-7.5K(L)218.4 V ± 1%
Giant Elite 31-10K(L)218.4 V ± 1%
Standard Model Recharge Time
Giant Elite 31-6K(L)6 hours recover to 90% capacity
Giant Elite 31-7.5K(L)6 hours recover to 90% capacity
Giant Elite 31-10K(L)6 hours recover to 90% capacity
INDICATORS
LCD
Giant Elite 31-6K(L)UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code
Giant Elite 31-7.5K(L)UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code
Giant Elite 31-10K(L)UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code
ALARM
Battery Mode
Giant Elite 31-6K(L)Sounding every 4 seconds
Giant Elite 31-7.5K(L)Sounding every 4 seconds
Giant Elite 31-10K(L)Sounding every 4 seconds
Low Battery
Giant Elite 31-6K(L)Sounding every second
Giant Elite 31-7.5K(L)Sounding every second
Giant Elite 31-10K(L)Sounding every second
Overload
Giant Elite 31-6K(L)Sounding twice every second
Giant Elite 31-7.5K(L)Sounding twice every second
Giant Elite 31-10K(L)Sounding twice every second
Fault
Giant Elite 31-6K(L)Continuously sounding
Giant Elite 31-7.5K(L)Continuously sounding
Giant Elite 31-10K(L)Continuously sounding
ENVIRONMENT
Operating Temperature
Giant Elite 31-6K(L)0~50°C (battery life cycle will be shorten when temperature is above 25°C)
Giant Elite 31-7.5K(L)0~50°C (battery life cycle will be shorten when temperature is above 25°C)
Giant Elite 31-10K(L)0~50°C (battery life cycle will be shorten when temperature is above 25°C)
Operating Humidity
Giant Elite 31-6K(L)<95% and non-condersing
Giant Elite 31-7.5K(L)<95% and non-condersing
Giant Elite 31-10K(L)<95% and non-condersing
Noise Level
Giant Elite 31-6K(L)Less than 60dB @ 1 Meter
Giant Elite 31-7.5K(L)Less than 60dB @ 1 Meter
Giant Elite 31-10K(L)Less than 60dB @ 1 Meter
PHYSICAL
Standard Model Dimensions, D x W x H(mm)
Giant Elite 31-6K(L)592 x 300 x 826, 592 x 360 x 826
Giant Elite 31-7.5K(L)592 x 300 x 826, 592 x 360 x 826
Giant Elite 31-10K(L)592 x 300 x 826, 592 x 360 x 826
Standard Model Net Weight (Kgs)
Giant Elite 31-6K(L)129, 137
Giant Elite 31-7.5K(L)152, 160
Giant Elite 31-10K(L)160, 168
Long-run Model Dimensions, D x W x H(mm)
Giant Elite 31-6K(L)592 x 300 x 826
Giant Elite 31-7.5K(L)592 x 300 x 826
Giant Elite 31-10K(L)592 x 300 x 826
Long-run Model Net Weight (Kgs)
Giant Elite 31-6K(L)84
Giant Elite 31-7.5K(L)107
Giant Elite 31-10K(L)115
MANAGEMENT
Optional SNMP
Giant Elite 31-6K(L)Power management from SNMP manager and web browser
Giant Elite 31-7.5K(L)Power management from SNMP manager and web browser
Giant Elite 31-10K(L)Power management from SNMP manager and web browser
Modbus RS-232 / RS485
Giant Elite 31-6K(L)Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC
Giant Elite 31-7.5K(L)Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC
Giant Elite 31-10K(L)Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC