Giant Elite 3P/1P 6K/7.5K/10KVA
3-Phase Online UPS Integrated with an Isolation Transformer
Equipped with an isolation transformer, the Giant series effectively removes common-mode noise and eliminates the requirement for costly specialized circuitry. It delivers dependable galvanic isolation power to essential devices.
Main Features
  • Galvanic isolation designed to handle all types of loads
  • Output power factor of 0.8
  • Fully coated PCBAs for durability in harsh environments
  • Distinctive ventilation system for efficient heat dissipation
  • Wide input voltage and frequency range to endure demanding conditions
  • High resistance to short circuits and overloads
  • Integrated maintenance bypass switch
General
CAPACITY
Giant Elite 31-6K(L)6 KVA / 4.8 KW
Giant Elite 31-7.5K(L)7.5 KVA / 6 KW
Giant Elite 31-10K(L)10 KVA / 8 KW
PHASE
Giant Elite 31-6K(L)3-phase in / 1-phase out
Giant Elite 31-7.5K(L)3-phase in / 1-phase out
Giant Elite 31-10K(L)3-phase in / 1-phase out
INPUT
Nominal Voltage
Giant Elite 31-6K(L)3 x 360VAC/380VAC/400VAC (3Ph + N + G)
Giant Elite 31-7.5K(L)3 x 360VAC/380VAC/400VAC (3Ph + N + G)
Giant Elite 31-10K(L)3 x 360VAC/380VAC/400VAC (3Ph + N + G)
Acceptable Voltage Range
Giant Elite 31-6K(L)286VAC~493VAC @ 16 pcs of batteries; 320VAC~493VAC @ 18 pcs of batteries
Giant Elite 31-7.5K(L)286VAC~493VAC @ 16 pcs of batteries; 320VAC~493VAC @ 18 pcs of batteries
Giant Elite 31-10K(L)286VAC~493VAC @ 16 pcs of batteries; 320VAC~493VAC @ 18 pcs of batteries
Frequency
Giant Elite 31-6K(L)40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system
Giant Elite 31-7.5K(L)40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system
Giant Elite 31-10K(L)40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system
OUTPUT
Voltage Regulation
Giant Elite 31-6K(L)± 1%
Giant Elite 31-7.5K(L)± 1%
Giant Elite 31-10K(L)± 1%
Output Voltage
Giant Elite 31-6K(L)208VAC/220VAC/230VAC (Selectable)
Giant Elite 31-7.5K(L)208VAC/220VAC/230VAC (Selectable)
Giant Elite 31-10K(L)208VAC/220VAC/230VAC (Selectable)
Frequency Range (Batt. Mode)
Giant Elite 31-6K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Giant Elite 31-7.5K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Giant Elite 31-10K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Transfer Time AC to DC
Giant Elite 31-6K(L)Zero
Giant Elite 31-7.5K(L)Zero
Giant Elite 31-10K(L)Zero
Transfer Time Inverter to Bypass
Giant Elite 31-6K(L)Zero
Giant Elite 31-7.5K(L)Zero
Giant Elite 31-10K(L)Zero
Transfer Time Waveform (Batt. Mode)
Giant Elite 31-6K(L)Pure Sine Wave
Giant Elite 31-7.5K(L)Pure Sine Wave
Giant Elite 31-10K(L)Pure Sine Wave
Efficiency Battery Mode
Giant Elite 31-6K(L)92%
Giant Elite 31-7.5K(L)92%
Giant Elite 31-10K(L)92%
Efficiency Line Mode
Giant Elite 31-6K(L)83%
Giant Elite 31-7.5K(L)83%
Giant Elite 31-10K(L)83%
Frequency Range
Giant Elite 31-6K(L)45Hz~55 Hz or 56 Hz~64 Hz
Giant Elite 31-7.5K(L)45Hz~55 Hz or 56 Hz~64 Hz
Giant Elite 31-10K(L)45Hz~55 Hz or 56 Hz~64 Hz
Current Crest Ratio
Giant Elite 31-6K(L)3:1
Giant Elite 31-7.5K(L)3:1
Giant Elite 31-10K(L)3:1
Harmonic Distortion
Giant Elite 31-6K(L)<3% THD (Linear Load); <5% THD (Non-linear Load)
Giant Elite 31-7.5K(L)<3% THD (Linear Load); <5% THD (Non-linear Load)
Giant Elite 31-10K(L)<3% THD (Linear Load); <5% THD (Non-linear Load)
BATTERY
Long-run Model Battery Numbers
Giant Elite 31-6K(L)16pcs, 18 pcs
Giant Elite 31-7.5K(L)16pcs, 18 pcs
Giant Elite 31-10K(L)16pcs, 18 pcs
Long-run Model Battery Type
Giant Elite 31-6K(L)Depending on the applications
Giant Elite 31-7.5K(L)Depending on the applications
Giant Elite 31-10K(L)Depending on the applications
Long-run Model Charging Current (max.)
Giant Elite 31-6K(L)Default: 8A, 2A/4A/8A(adjustable)
Giant Elite 31-7.5K(L)Default: 8A, 2A/4A/8A(adjustable)
Giant Elite 31-10K(L)Default: 8A, 2A/4A/8A(adjustable)
Long-run Model Charging Voltage
Giant Elite 31-6K(L)218.4 V ± 1%, 245.7 V ± 1%
Giant Elite 31-7.5K(L)218.4 V ± 1%, 245.7 V ± 1%
Giant Elite 31-10K(L)218.4 V ± 1%, 245.7 V ± 1%
Standard Model Battery Numbers
Giant Elite 31-6K(L)16pcs
Giant Elite 31-7.5K(L)16pcs
Giant Elite 31-10K(L)16pcs
Standard Model Battery Type
Giant Elite 31-6K(L)12V / 9Ah
Giant Elite 31-7.5K(L)12V / 9Ah
Giant Elite 31-10K(L)12V / 9Ah
Standard Model Charging Current (max.)
Giant Elite 31-6K(L)2A
Giant Elite 31-7.5K(L)2A
Giant Elite 31-10K(L)2A
Standard Model Charging Voltage
Giant Elite 31-6K(L)218.4 V ± 1%
Giant Elite 31-7.5K(L)218.4 V ± 1%
Giant Elite 31-10K(L)218.4 V ± 1%
Standard Model Recharge Time
Giant Elite 31-6K(L)6 hours recover to 90% capacity
Giant Elite 31-7.5K(L)6 hours recover to 90% capacity
Giant Elite 31-10K(L)6 hours recover to 90% capacity
INDICATORS
LCD
Giant Elite 31-6K(L)UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code
Giant Elite 31-7.5K(L)UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code
Giant Elite 31-10K(L)UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code
ALARM
Battery Mode
Giant Elite 31-6K(L)Sounding every 4 seconds
Giant Elite 31-7.5K(L)Sounding every 4 seconds
Giant Elite 31-10K(L)Sounding every 4 seconds
Low Battery
Giant Elite 31-6K(L)Sounding every second
Giant Elite 31-7.5K(L)Sounding every second
Giant Elite 31-10K(L)Sounding every second
Overload
Giant Elite 31-6K(L)Sounding twice every second
Giant Elite 31-7.5K(L)Sounding twice every second
Giant Elite 31-10K(L)Sounding twice every second
Fault
Giant Elite 31-6K(L)Continuously sounding
Giant Elite 31-7.5K(L)Continuously sounding
Giant Elite 31-10K(L)Continuously sounding
ENVIRONMENT
Operating Temperature
Giant Elite 31-6K(L)0~50°C (battery life cycle will be shorten when temperature is above 25°C)
Giant Elite 31-7.5K(L)0~50°C (battery life cycle will be shorten when temperature is above 25°C)
Giant Elite 31-10K(L)0~50°C (battery life cycle will be shorten when temperature is above 25°C)
Operating Humidity
Giant Elite 31-6K(L)<95% and non-condersing
Giant Elite 31-7.5K(L)<95% and non-condersing
Giant Elite 31-10K(L)<95% and non-condersing
Noise Level
Giant Elite 31-6K(L)Less than 60dB @ 1 Meter
Giant Elite 31-7.5K(L)Less than 60dB @ 1 Meter
Giant Elite 31-10K(L)Less than 60dB @ 1 Meter
PHYSICAL
Standard Model Dimensions, D x W x H(mm)
Giant Elite 31-6K(L)592 x 300 x 826, 592 x 360 x 826
Giant Elite 31-7.5K(L)592 x 300 x 826, 592 x 360 x 826
Giant Elite 31-10K(L)592 x 300 x 826, 592 x 360 x 826
Standard Model Net Weight (Kgs)
Giant Elite 31-6K(L)129, 137
Giant Elite 31-7.5K(L)152, 160
Giant Elite 31-10K(L)160, 168
Long-run Model Dimensions, D x W x H(mm)
Giant Elite 31-6K(L)592 x 300 x 826
Giant Elite 31-7.5K(L)592 x 300 x 826
Giant Elite 31-10K(L)592 x 300 x 826
Long-run Model Net Weight (Kgs)
Giant Elite 31-6K(L)84
Giant Elite 31-7.5K(L)107
Giant Elite 31-10K(L)115
MANAGEMENT
Optional SNMP
Giant Elite 31-6K(L)Power management from SNMP manager and web browser
Giant Elite 31-7.5K(L)Power management from SNMP manager and web browser
Giant Elite 31-10K(L)Power management from SNMP manager and web browser
Modbus RS-232 / RS485
Giant Elite 31-6K(L)Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC
Giant Elite 31-7.5K(L)Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC
Giant Elite 31-10K(L)Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC