Giant Elite 1P/1P 6K-10K
Transformer-type Online UPS
Giant Elite integrates DSP technology and isolation transformer design to easily adapt to all kinds of diverse and complicated loads, such as heavy duty equipment and half-wave loads. Unique ventilation and fully coating PCBAs allow Giant Elite UPS to operate under harsh environment for long time. Giant Elite provides the same functions is indeed 5% smaller size.

Main Features
- Galvanic isolation design to withstand all kinds of load
- Output power factor 0.8
- Fully coating PCBAs to withstand harsh environment
- Unique ventilation design for effective heat dissipation
- Wide input voltage and frequency range to withstand robust environment
- High short-circuit and overload capabilities
- Built-in Maintenance bypass switch
MODEL | Giant Elite 6K(L) | Giant Elite 7.5K(L) | Giant Elite 10K(L) | |
CAPACITY | 6 KVA / 4.8 KW | 7.5 KVA / 6 KW | 10 KVA / 8 KW | |
PHASE | 1-phase in / 1-phase out | 1-phase in / 1-phase out | 1-phase in / 1-phase out | |
INPUT | ||||
Nominal Voltage | 208VAC/220VAC/230VAC | 208VAC/220VAC/230VAC | 208VAC/220VAC/230VAC | |
Acceptable Voltage Range | 165VAC ~ 285VAC @ 16 pcs of batteries ; 185VAC ~ 285VAC @ 18 pcs of batteries | 165VAC ~ 285VAC @ 16 pcs of batteries ; 185VAC ~ 285VAC @ 18 pcs of batteries | 165VAC ~ 285VAC @ 16 pcs of batteries ; 185VAC ~ 285VAC @ 18 pcs of batteries | |
Frequency | 40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system | 40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system | 40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system | |
OUTPUT | ||||
Voltage Regulation | ± 1% | ± 1% | ± 1% | |
Output Voltage | 208VAC/220VAC/230VAC | 208VAC/220VAC/230VAC | 208VAC/220VAC/230VAC | |
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |
Transfer Time | AC to DC | Zero | Zero | Zero |
Transfer Time | Inverter to Bypass | Zero | Zero | Zero |
Transfer Time | Waveform (Batt. Mode) | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave |
Efficiency | AC Mode | 88.3% | 88.3% | 88.3% |
Efficiency | Battery Mode | 92% | 92% | 92% |
Frequency Range | 45Hz~55 Hz or 56 Hz~64 Hz | 45Hz~55 Hz or 56 Hz~64 Hz | 45Hz~55 Hz or 56 Hz~64 Hz | |
Current Crest Ratio | 3:1 | 3:1 | 3:1 | |
Harmonic Distortion | <3% THD (Linear Load); <5% THD (Non-linear Load) | <3% THD (Linear Load); <5% THD (Non-linear Load) | <3% THD (Linear Load); <5% THD (Non-linear Load) | |
BATTERY | ||||
Long-run Model | Battery Numbers | 16pcs, 18 pcs | 16pcs, 18 pcs | 16pcs, 18 pcs |
Long-run Model | Battery Type | Depending on the applications | Depending on the applications | Depending on the applications |
Long-run Model | Charging Current (max.) | Default: 8A, 2A/4A/8A(adjustable) | Default: 8A, 2A/4A/8A(adjustable) | Default: 8A, 2A/4A/8A(adjustable) |
Long-run Model | Charging Voltage | 218.4 V ± 1%, 245.7 V ± 1% | 218.4 V ± 1%, 245.7 V ± 1% | 218.4 V ± 1%, 245.7 V ± 1% |
Standard Model | Battery Numbers | 16pcs | 16pcs | 16pcs |
Standard Model | Battery Type | 12V / 9Ah | 12V / 9Ah | 12V / 9Ah |
Standard Model | Charging Current (max.) | 2A | 2A | 2A |
Standard Model | Charging Voltage | 218.4 V ± 1% | 218.4 V ± 1% | 218.4 V ± 1% |
Standard Model | Recharge Time | 6 hours recover to 90% capacity | 6 hours recover to 90% capacity | 6 hours recover to 90% capacity |
INDICATORS | ||||
LCD | UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code | UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code | UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code | |
ALARM | ||||
Battery Mode | Sounding every 4 seconds | Sounding every 4 seconds | Sounding every 4 seconds | |
Low Battery | Sounding every second | Sounding every second | Sounding every second | |
Overload | Sounding twice every second | Sounding twice every second | Sounding twice every second | |
Fault | Continuously sounding | Continuously sounding | Continuously sounding | |
ENVIRONMENT | ||||
Operating Temperature | 0~50°C (battery life cycle will be shorten when temperature is above 25°C) | 0~50°C (battery life cycle will be shorten when temperature is above 25°C) | 0~50°C (battery life cycle will be shorten when temperature is above 25°C) | |
Operating Humidity | <95% and non-condersing | <95% and non-condersing | <95% and non-condersing | |
Noise Level | Less than 60dB @ 1 Meter | Less than 60dB @ 1 Meter | Less than 60dB @ 1 Meter | |
PHYSICAL | ||||
Standard Model | Dimensions, D x W x H(mm) | 592 x 300 x 826 | 592 x 300 x 826 | 592 x 300 x 826 |
Standard Model | Net Weight (Kgs) | 106, 114 | 122, 130 | 130, 138 |
Long-run Model | Dimensions, D x W x H(mm) | 592 x 250 x 826 | 592 x 250 x 826 | 592 x 250 x 826 |
Long-run Model | Net Weight (Kgs) | 62 | 78 | 86 |
MANAGEMENT | ||||
Optional SNMP | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | |
Modbus RS-232 / RS485 | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC |
General
CAPACITY
Giant Elite 6K(L) | 6 KVA / 4.8 KW |
---|---|
Giant Elite 7.5K(L) | 7.5 KVA / 6 KW |
Giant Elite 10K(L) | 10 KVA / 8 KW |
PHASE
Giant Elite 6K(L) | 1-phase in / 1-phase out |
---|---|
Giant Elite 7.5K(L) | 1-phase in / 1-phase out |
Giant Elite 10K(L) | 1-phase in / 1-phase out |
INPUT
Nominal Voltage
Giant Elite 6K(L) | 208VAC/220VAC/230VAC |
---|---|
Giant Elite 7.5K(L) | 208VAC/220VAC/230VAC |
Giant Elite 10K(L) | 208VAC/220VAC/230VAC |
Acceptable Voltage Range
Giant Elite 6K(L) | 165VAC ~ 285VAC @ 16 pcs of batteries ; 185VAC ~ 285VAC @ 18 pcs of batteries |
---|---|
Giant Elite 7.5K(L) | 165VAC ~ 285VAC @ 16 pcs of batteries ; 185VAC ~ 285VAC @ 18 pcs of batteries |
Giant Elite 10K(L) | 165VAC ~ 285VAC @ 16 pcs of batteries ; 185VAC ~ 285VAC @ 18 pcs of batteries |
Frequency
Giant Elite 6K(L) | 40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system |
---|---|
Giant Elite 7.5K(L) | 40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system |
Giant Elite 10K(L) | 40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system |
OUTPUT
Voltage Regulation
Giant Elite 6K(L) | ± 1% |
---|---|
Giant Elite 7.5K(L) | ± 1% |
Giant Elite 10K(L) | ± 1% |
Output Voltage
Giant Elite 6K(L) | 208VAC/220VAC/230VAC |
---|---|
Giant Elite 7.5K(L) | 208VAC/220VAC/230VAC |
Giant Elite 10K(L) | 208VAC/220VAC/230VAC |
Frequency Range (Batt. Mode)
Giant Elite 6K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
---|---|
Giant Elite 7.5K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Giant Elite 10K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Transfer Time AC to DC
Giant Elite 6K(L) | Zero |
---|---|
Giant Elite 7.5K(L) | Zero |
Giant Elite 10K(L) | Zero |
Transfer Time Inverter to Bypass
Giant Elite 6K(L) | Zero |
---|---|
Giant Elite 7.5K(L) | Zero |
Giant Elite 10K(L) | Zero |
Transfer Time Waveform (Batt. Mode)
Giant Elite 6K(L) | Pure Sine Wave |
---|---|
Giant Elite 7.5K(L) | Pure Sine Wave |
Giant Elite 10K(L) | Pure Sine Wave |
Efficiency AC Mode
Giant Elite 6K(L) | 88.3% |
---|---|
Giant Elite 7.5K(L) | 88.3% |
Giant Elite 10K(L) | 88.3% |
Efficiency Battery Mode
Giant Elite 6K(L) | 92% |
---|---|
Giant Elite 7.5K(L) | 92% |
Giant Elite 10K(L) | 92% |
Frequency Range
Giant Elite 6K(L) | 45Hz~55 Hz or 56 Hz~64 Hz |
---|---|
Giant Elite 7.5K(L) | 45Hz~55 Hz or 56 Hz~64 Hz |
Giant Elite 10K(L) | 45Hz~55 Hz or 56 Hz~64 Hz |
Current Crest Ratio
Giant Elite 6K(L) | 3:1 |
---|---|
Giant Elite 7.5K(L) | 3:1 |
Giant Elite 10K(L) | 3:1 |
Harmonic Distortion
Giant Elite 6K(L) | <3% THD (Linear Load); <5% THD (Non-linear Load) |
---|---|
Giant Elite 7.5K(L) | <3% THD (Linear Load); <5% THD (Non-linear Load) |
Giant Elite 10K(L) | <3% THD (Linear Load); <5% THD (Non-linear Load) |
BATTERY
Long-run Model Battery Numbers
Giant Elite 6K(L) | 16pcs, 18 pcs |
---|---|
Giant Elite 7.5K(L) | 16pcs, 18 pcs |
Giant Elite 10K(L) | 16pcs, 18 pcs |
Long-run Model Battery Type
Giant Elite 6K(L) | Depending on the applications |
---|---|
Giant Elite 7.5K(L) | Depending on the applications |
Giant Elite 10K(L) | Depending on the applications |
Long-run Model Charging Current (max.)
Giant Elite 6K(L) | Default: 8A, 2A/4A/8A(adjustable) |
---|---|
Giant Elite 7.5K(L) | Default: 8A, 2A/4A/8A(adjustable) |
Giant Elite 10K(L) | Default: 8A, 2A/4A/8A(adjustable) |
Long-run Model Charging Voltage
Giant Elite 6K(L) | 218.4 V ± 1%, 245.7 V ± 1% |
---|---|
Giant Elite 7.5K(L) | 218.4 V ± 1%, 245.7 V ± 1% |
Giant Elite 10K(L) | 218.4 V ± 1%, 245.7 V ± 1% |
Standard Model Battery Numbers
Giant Elite 6K(L) | 16pcs |
---|---|
Giant Elite 7.5K(L) | 16pcs |
Giant Elite 10K(L) | 16pcs |
Standard Model Battery Type
Giant Elite 6K(L) | 12V / 9Ah |
---|---|
Giant Elite 7.5K(L) | 12V / 9Ah |
Giant Elite 10K(L) | 12V / 9Ah |
Standard Model Charging Current (max.)
Giant Elite 6K(L) | 2A |
---|---|
Giant Elite 7.5K(L) | 2A |
Giant Elite 10K(L) | 2A |
Standard Model Charging Voltage
Giant Elite 6K(L) | 218.4 V ± 1% |
---|---|
Giant Elite 7.5K(L) | 218.4 V ± 1% |
Giant Elite 10K(L) | 218.4 V ± 1% |
Standard Model Recharge Time
Giant Elite 6K(L) | 6 hours recover to 90% capacity |
---|---|
Giant Elite 7.5K(L) | 6 hours recover to 90% capacity |
Giant Elite 10K(L) | 6 hours recover to 90% capacity |
INDICATORS
LCD
Giant Elite 6K(L) | UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code |
---|---|
Giant Elite 7.5K(L) | UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code |
Giant Elite 10K(L) | UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code |
ALARM
Battery Mode
Giant Elite 6K(L) | Sounding every 4 seconds |
---|---|
Giant Elite 7.5K(L) | Sounding every 4 seconds |
Giant Elite 10K(L) | Sounding every 4 seconds |
Low Battery
Giant Elite 6K(L) | Sounding every second |
---|---|
Giant Elite 7.5K(L) | Sounding every second |
Giant Elite 10K(L) | Sounding every second |
Overload
Giant Elite 6K(L) | Sounding twice every second |
---|---|
Giant Elite 7.5K(L) | Sounding twice every second |
Giant Elite 10K(L) | Sounding twice every second |
Fault
Giant Elite 6K(L) | Continuously sounding |
---|---|
Giant Elite 7.5K(L) | Continuously sounding |
Giant Elite 10K(L) | Continuously sounding |
ENVIRONMENT
Operating Temperature
Giant Elite 6K(L) | 0~50°C (battery life cycle will be shorten when temperature is above 25°C) |
---|---|
Giant Elite 7.5K(L) | 0~50°C (battery life cycle will be shorten when temperature is above 25°C) |
Giant Elite 10K(L) | 0~50°C (battery life cycle will be shorten when temperature is above 25°C) |
Operating Humidity
Giant Elite 6K(L) | <95% and non-condersing |
---|---|
Giant Elite 7.5K(L) | <95% and non-condersing |
Giant Elite 10K(L) | <95% and non-condersing |
Noise Level
Giant Elite 6K(L) | Less than 60dB @ 1 Meter |
---|---|
Giant Elite 7.5K(L) | Less than 60dB @ 1 Meter |
Giant Elite 10K(L) | Less than 60dB @ 1 Meter |
PHYSICAL
Standard Model Dimensions, D x W x H(mm)
Giant Elite 6K(L) | 592 x 300 x 826 |
---|---|
Giant Elite 7.5K(L) | 592 x 300 x 826 |
Giant Elite 10K(L) | 592 x 300 x 826 |
Standard Model Net Weight (Kgs)
Giant Elite 6K(L) | 106, 114 |
---|---|
Giant Elite 7.5K(L) | 122, 130 |
Giant Elite 10K(L) | 130, 138 |
Long-run Model Dimensions, D x W x H(mm)
Giant Elite 6K(L) | 592 x 250 x 826 |
---|---|
Giant Elite 7.5K(L) | 592 x 250 x 826 |
Giant Elite 10K(L) | 592 x 250 x 826 |
Long-run Model Net Weight (Kgs)
Giant Elite 6K(L) | 62 |
---|---|
Giant Elite 7.5K(L) | 78 |
Giant Elite 10K(L) | 86 |
MANAGEMENT
Optional SNMP
Giant Elite 6K(L) | Power management from SNMP manager and web browser |
---|---|
Giant Elite 7.5K(L) | Power management from SNMP manager and web browser |
Giant Elite 10K(L) | Power management from SNMP manager and web browser |
Modbus RS-232 / RS485
Giant Elite 6K(L) | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC |
---|---|
Giant Elite 7.5K(L) | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC |
Giant Elite 10K(L) | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC |
![]() |
Manual | Giant Elite 1P-1P_manual |