- Select Capacity
- Giant Elite 6K(L)
- Giant Elite 7.5K(L)
- Giant Elite 10K(L)
- Select Capacity
- Giant Elite 6K(L)
- Giant Elite 7.5K(L)
- Giant Elite 10K(L)
92
Giant Elite 1P/1P 6K-10K
Transformer-type Online UPS
The Giant Elite combines DSP technology with an isolation transformer design to effortlessly handle a wide range of complex and varied loads, including heavy-duty machinery and half-wave loads. Its distinctive ventilation system and fully coated PCBAs enable the Giant Elite UPS to function reliably in harsh environments for extended periods. Additionally, the Giant Elite offers the same features while being approximately 5% smaller in size.
Main Features
- Galvanic isolation designed to handle all types of loads
- Output power factor of 0.8
- Fully coated PCBAs for durability in harsh environments
- Innovative ventilation system for efficient heat dissipation
- Wide input voltage and frequency range to endure demanding conditions
- High resistance to short circuits and overloads
- Integrated maintenance bypass switch
| MODEL | Giant Elite 6K(L) | Giant Elite 7.5K(L) | Giant Elite 10K(L) | |
| CAPACITY | 6 KVA / 4.8 KW | 7.5 KVA / 6 KW | 10 KVA / 8 KW | |
| PHASE | 1-phase in / 1-phase out | 1-phase in / 1-phase out | 1-phase in / 1-phase out | |
| INPUT | ||||
| Nominal Voltage | 208VAC/220VAC/230VAC | 208VAC/220VAC/230VAC | 208VAC/220VAC/230VAC | |
| Acceptable Voltage Range | 165VAC ~ 285VAC @ 16 pcs of batteries ; 185VAC ~ 285VAC @ 18 pcs of batteries | 165VAC ~ 285VAC @ 16 pcs of batteries ; 185VAC ~ 285VAC @ 18 pcs of batteries | 165VAC ~ 285VAC @ 16 pcs of batteries ; 185VAC ~ 285VAC @ 18 pcs of batteries | |
| Frequency | 40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system | 40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system | 40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system | |
| OUTPUT | ||||
| Voltage Regulation | ± 1% | ± 1% | ± 1% | |
| Output Voltage | 208VAC/220VAC/230VAC | 208VAC/220VAC/230VAC | 208VAC/220VAC/230VAC | |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |
| Transfer Time | AC to DC | Zero | Zero | Zero |
| Transfer Time | Inverter to Bypass | Zero | Zero | Zero |
| Transfer Time | Waveform (Batt. Mode) | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave |
| Efficiency | AC Mode | 88.3% | 88.3% | 88.3% |
| Efficiency | Battery Mode | 92% | 92% | 92% |
| Frequency Range | 45Hz~55 Hz or 56 Hz~64 Hz | 45Hz~55 Hz or 56 Hz~64 Hz | 45Hz~55 Hz or 56 Hz~64 Hz | |
| Current Crest Ratio | 3:1 | 3:1 | 3:1 | |
| Harmonic Distortion | <3% THD (Linear Load); <5% THD (Non-linear Load) | <3% THD (Linear Load); <5% THD (Non-linear Load) | <3% THD (Linear Load); <5% THD (Non-linear Load) | |
| BATTERY | ||||
| Long-run Model | Battery Numbers | 16pcs, 18 pcs | 16pcs, 18 pcs | 16pcs, 18 pcs |
| Long-run Model | Battery Type | Depending on the applications | Depending on the applications | Depending on the applications |
| Long-run Model | Charging Current (max.) | Default: 8A, 2A/4A/8A(adjustable) | Default: 8A, 2A/4A/8A(adjustable) | Default: 8A, 2A/4A/8A(adjustable) |
| Long-run Model | Charging Voltage | 218.4 V ± 1%, 245.7 V ± 1% | 218.4 V ± 1%, 245.7 V ± 1% | 218.4 V ± 1%, 245.7 V ± 1% |
| Standard Model | Battery Numbers | 16pcs | 16pcs | 16pcs |
| Standard Model | Battery Type | 12V / 9Ah | 12V / 9Ah | 12V / 9Ah |
| Standard Model | Charging Current (max.) | 2A | 2A | 2A |
| Standard Model | Charging Voltage | 218.4 V ± 1% | 218.4 V ± 1% | 218.4 V ± 1% |
| Standard Model | Recharge Time | 6 hours recover to 90% capacity | 6 hours recover to 90% capacity | 6 hours recover to 90% capacity |
| INDICATORS | ||||
| LCD | UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code | UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code | UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code | |
| ALARM | ||||
| Battery Mode | Sounding every 4 seconds | Sounding every 4 seconds | Sounding every 4 seconds | |
| Low Battery | Sounding every second | Sounding every second | Sounding every second | |
| Overload | Sounding twice every second | Sounding twice every second | Sounding twice every second | |
| Fault | Continuously sounding | Continuously sounding | Continuously sounding | |
| ENVIRONMENT | ||||
| Operating Temperature | 0~50°C (battery life cycle will be shorten when temperature is above 25°C) | 0~50°C (battery life cycle will be shorten when temperature is above 25°C) | 0~50°C (battery life cycle will be shorten when temperature is above 25°C) | |
| Operating Humidity | <95% and non-condersing | <95% and non-condersing | <95% and non-condersing | |
| Noise Level | Less than 60dB @ 1 Meter | Less than 60dB @ 1 Meter | Less than 60dB @ 1 Meter | |
| PHYSICAL | ||||
| Standard Model | Dimensions, D x W x H(mm) | 592 x 300 x 826 | 592 x 300 x 826 | 592 x 300 x 826 |
| Standard Model | Net Weight (Kgs) | 106, 114 | 122, 130 | 130, 138 |
| Long-run Model | Dimensions, D x W x H(mm) | 592 x 250 x 826 | 592 x 250 x 826 | 592 x 250 x 826 |
| Long-run Model | Net Weight (Kgs) | 62 | 78 | 86 |
| MANAGEMENT | ||||
| Optional SNMP | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | |
| Modbus RS-232 / RS485 | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC | |
General
CAPACITY
| Giant Elite 6K(L) | 6 KVA / 4.8 KW |
|---|---|
| Giant Elite 7.5K(L) | 7.5 KVA / 6 KW |
| Giant Elite 10K(L) | 10 KVA / 8 KW |
PHASE
| Giant Elite 6K(L) | 1-phase in / 1-phase out |
|---|---|
| Giant Elite 7.5K(L) | 1-phase in / 1-phase out |
| Giant Elite 10K(L) | 1-phase in / 1-phase out |
INPUT
Nominal Voltage
| Giant Elite 6K(L) | 208VAC/220VAC/230VAC |
|---|---|
| Giant Elite 7.5K(L) | 208VAC/220VAC/230VAC |
| Giant Elite 10K(L) | 208VAC/220VAC/230VAC |
Acceptable Voltage Range
| Giant Elite 6K(L) | 165VAC ~ 285VAC @ 16 pcs of batteries ; 185VAC ~ 285VAC @ 18 pcs of batteries |
|---|---|
| Giant Elite 7.5K(L) | 165VAC ~ 285VAC @ 16 pcs of batteries ; 185VAC ~ 285VAC @ 18 pcs of batteries |
| Giant Elite 10K(L) | 165VAC ~ 285VAC @ 16 pcs of batteries ; 185VAC ~ 285VAC @ 18 pcs of batteries |
Frequency
| Giant Elite 6K(L) | 40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system |
|---|---|
| Giant Elite 7.5K(L) | 40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system |
| Giant Elite 10K(L) | 40Hz~55 Hz @ 50Hz system; 56 Hz~64Hz @ 60Hz system |
OUTPUT
Voltage Regulation
| Giant Elite 6K(L) | ± 1% |
|---|---|
| Giant Elite 7.5K(L) | ± 1% |
| Giant Elite 10K(L) | ± 1% |
Output Voltage
| Giant Elite 6K(L) | 208VAC/220VAC/230VAC |
|---|---|
| Giant Elite 7.5K(L) | 208VAC/220VAC/230VAC |
| Giant Elite 10K(L) | 208VAC/220VAC/230VAC |
Frequency Range (Batt. Mode)
| Giant Elite 6K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
|---|---|
| Giant Elite 7.5K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Giant Elite 10K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Transfer Time AC to DC
| Giant Elite 6K(L) | Zero |
|---|---|
| Giant Elite 7.5K(L) | Zero |
| Giant Elite 10K(L) | Zero |
Transfer Time Inverter to Bypass
| Giant Elite 6K(L) | Zero |
|---|---|
| Giant Elite 7.5K(L) | Zero |
| Giant Elite 10K(L) | Zero |
Transfer Time Waveform (Batt. Mode)
| Giant Elite 6K(L) | Pure Sine Wave |
|---|---|
| Giant Elite 7.5K(L) | Pure Sine Wave |
| Giant Elite 10K(L) | Pure Sine Wave |
Efficiency AC Mode
| Giant Elite 6K(L) | 88.3% |
|---|---|
| Giant Elite 7.5K(L) | 88.3% |
| Giant Elite 10K(L) | 88.3% |
Efficiency Battery Mode
| Giant Elite 6K(L) | 92% |
|---|---|
| Giant Elite 7.5K(L) | 92% |
| Giant Elite 10K(L) | 92% |
Frequency Range
| Giant Elite 6K(L) | 45Hz~55 Hz or 56 Hz~64 Hz |
|---|---|
| Giant Elite 7.5K(L) | 45Hz~55 Hz or 56 Hz~64 Hz |
| Giant Elite 10K(L) | 45Hz~55 Hz or 56 Hz~64 Hz |
Current Crest Ratio
| Giant Elite 6K(L) | 3:1 |
|---|---|
| Giant Elite 7.5K(L) | 3:1 |
| Giant Elite 10K(L) | 3:1 |
Harmonic Distortion
| Giant Elite 6K(L) | <3% THD (Linear Load); <5% THD (Non-linear Load) |
|---|---|
| Giant Elite 7.5K(L) | <3% THD (Linear Load); <5% THD (Non-linear Load) |
| Giant Elite 10K(L) | <3% THD (Linear Load); <5% THD (Non-linear Load) |
BATTERY
Long-run Model Battery Numbers
| Giant Elite 6K(L) | 16pcs, 18 pcs |
|---|---|
| Giant Elite 7.5K(L) | 16pcs, 18 pcs |
| Giant Elite 10K(L) | 16pcs, 18 pcs |
Long-run Model Battery Type
| Giant Elite 6K(L) | Depending on the applications |
|---|---|
| Giant Elite 7.5K(L) | Depending on the applications |
| Giant Elite 10K(L) | Depending on the applications |
Long-run Model Charging Current (max.)
| Giant Elite 6K(L) | Default: 8A, 2A/4A/8A(adjustable) |
|---|---|
| Giant Elite 7.5K(L) | Default: 8A, 2A/4A/8A(adjustable) |
| Giant Elite 10K(L) | Default: 8A, 2A/4A/8A(adjustable) |
Long-run Model Charging Voltage
| Giant Elite 6K(L) | 218.4 V ± 1%, 245.7 V ± 1% |
|---|---|
| Giant Elite 7.5K(L) | 218.4 V ± 1%, 245.7 V ± 1% |
| Giant Elite 10K(L) | 218.4 V ± 1%, 245.7 V ± 1% |
Standard Model Battery Numbers
| Giant Elite 6K(L) | 16pcs |
|---|---|
| Giant Elite 7.5K(L) | 16pcs |
| Giant Elite 10K(L) | 16pcs |
Standard Model Battery Type
| Giant Elite 6K(L) | 12V / 9Ah |
|---|---|
| Giant Elite 7.5K(L) | 12V / 9Ah |
| Giant Elite 10K(L) | 12V / 9Ah |
Standard Model Charging Current (max.)
| Giant Elite 6K(L) | 2A |
|---|---|
| Giant Elite 7.5K(L) | 2A |
| Giant Elite 10K(L) | 2A |
Standard Model Charging Voltage
| Giant Elite 6K(L) | 218.4 V ± 1% |
|---|---|
| Giant Elite 7.5K(L) | 218.4 V ± 1% |
| Giant Elite 10K(L) | 218.4 V ± 1% |
Standard Model Recharge Time
| Giant Elite 6K(L) | 6 hours recover to 90% capacity |
|---|---|
| Giant Elite 7.5K(L) | 6 hours recover to 90% capacity |
| Giant Elite 10K(L) | 6 hours recover to 90% capacity |
INDICATORS
LCD
| Giant Elite 6K(L) | UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code |
|---|---|
| Giant Elite 7.5K(L) | UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code |
| Giant Elite 10K(L) | UPS status, load level, battery level, input/output voltage and frequency, fault code/warning code |
ALARM
Battery Mode
| Giant Elite 6K(L) | Sounding every 4 seconds |
|---|---|
| Giant Elite 7.5K(L) | Sounding every 4 seconds |
| Giant Elite 10K(L) | Sounding every 4 seconds |
Low Battery
| Giant Elite 6K(L) | Sounding every second |
|---|---|
| Giant Elite 7.5K(L) | Sounding every second |
| Giant Elite 10K(L) | Sounding every second |
Overload
| Giant Elite 6K(L) | Sounding twice every second |
|---|---|
| Giant Elite 7.5K(L) | Sounding twice every second |
| Giant Elite 10K(L) | Sounding twice every second |
Fault
| Giant Elite 6K(L) | Continuously sounding |
|---|---|
| Giant Elite 7.5K(L) | Continuously sounding |
| Giant Elite 10K(L) | Continuously sounding |
ENVIRONMENT
Operating Temperature
| Giant Elite 6K(L) | 0~50°C (battery life cycle will be shorten when temperature is above 25°C) |
|---|---|
| Giant Elite 7.5K(L) | 0~50°C (battery life cycle will be shorten when temperature is above 25°C) |
| Giant Elite 10K(L) | 0~50°C (battery life cycle will be shorten when temperature is above 25°C) |
Operating Humidity
| Giant Elite 6K(L) | <95% and non-condersing |
|---|---|
| Giant Elite 7.5K(L) | <95% and non-condersing |
| Giant Elite 10K(L) | <95% and non-condersing |
Noise Level
| Giant Elite 6K(L) | Less than 60dB @ 1 Meter |
|---|---|
| Giant Elite 7.5K(L) | Less than 60dB @ 1 Meter |
| Giant Elite 10K(L) | Less than 60dB @ 1 Meter |
PHYSICAL
Standard Model Dimensions, D x W x H(mm)
| Giant Elite 6K(L) | 592 x 300 x 826 |
|---|---|
| Giant Elite 7.5K(L) | 592 x 300 x 826 |
| Giant Elite 10K(L) | 592 x 300 x 826 |
Standard Model Net Weight (Kgs)
| Giant Elite 6K(L) | 106, 114 |
|---|---|
| Giant Elite 7.5K(L) | 122, 130 |
| Giant Elite 10K(L) | 130, 138 |
Long-run Model Dimensions, D x W x H(mm)
| Giant Elite 6K(L) | 592 x 250 x 826 |
|---|---|
| Giant Elite 7.5K(L) | 592 x 250 x 826 |
| Giant Elite 10K(L) | 592 x 250 x 826 |
Long-run Model Net Weight (Kgs)
| Giant Elite 6K(L) | 62 |
|---|---|
| Giant Elite 7.5K(L) | 78 |
| Giant Elite 10K(L) | 86 |
MANAGEMENT
Optional SNMP
| Giant Elite 6K(L) | Power management from SNMP manager and web browser |
|---|---|
| Giant Elite 7.5K(L) | Power management from SNMP manager and web browser |
| Giant Elite 10K(L) | Power management from SNMP manager and web browser |
Modbus RS-232 / RS485
| Giant Elite 6K(L) | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC |
|---|---|
| Giant Elite 7.5K(L) | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC |
| Giant Elite 10K(L) | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC |
| Manual | Giant Elite 1P-1P_manual |
Single phase - Online UPS Giant Elite 1P/1P 6K-10K Transformer-type Online UPS
Related Products