Giant 3P/3P 10KVA-160KVA
Embedded with isolation transformer
Embedded with isolation transformer, Giant series will eliminate common mode noise and the need to install expensive dedicated circuits. It provides reliable galvanically isolated power to critical equipment.
Main Features
  • Online double-conversion
  • DSP technology guarantees high reliability
  • True galvanic isolation transformer design
  • Control designed to withstand all kinds of loads
  • Intelligent battery management to prolong battery lifecycle
  • Independent ventilation enhance durable operation under harsh environment
  • Adjustable battery numbers
  • Accept dual-mains input
  • Parallel operation with up to 4 units (option)
  • Variety of communication options available
  • Optional 7" touch LCD
  • Reverse phase frequency operation and supports non-neutral input
General
CAPACITY
Giant 10K10 KVA / 8 KW
Giant 15K15 KVA / 12 KW
Giant 20K20KVA/16KW
Giant 30K30 KVA / 24 KW
Giant 40K40 KVA / 32 KW
Giant 60K60 KVA / 48 KW
Giant 80K80KVA/64KW
Giant 100K100 KVA / 80 KW
Giant 120K120 KVA / 96 KW
Giant 160K160 KVA / 128 KW
INPUT
Nominal Voltage
Giant 10K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 15K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 20K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 30K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 40K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 60K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 80K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 100K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 120K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 160K3 x 380VAC/400VAC/415VAC (3Ph+N)
Acceptable Voltage Range
Giant 10K165VAC ~ 280VAC (Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Giant 15K165VAC ~ 280VAC (Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Giant 20K165VAC ~ 280VAC (Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Giant 30K165VAC ~ 280VAC (Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Giant 40K165VAC ~ 280VAC (Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Giant 60K165VAC ~ 280VAC (Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Giant 80K165VAC ~ 280VAC (Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Giant 100K165VAC ~ 280VAC (Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Giant 120K165VAC ~ 280VAC (Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Giant 160K165VAC ~ 280VAC (Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Frequency
Giant 10K50 Hz/60 Hz ± 10%
Giant 15K50 Hz/60 Hz ± 10%
Giant 20K50 Hz/60 Hz ± 10%
Giant 30K50 Hz/60 Hz ± 10%
Giant 40K50 Hz/60 Hz ± 10%
Giant 60K50 Hz/60 Hz ± 10%
Giant 80K50 Hz/60 Hz ± 10%
Giant 100K50 Hz/60 Hz ± 10%
Giant 120K50 Hz/60 Hz ± 10%
Giant 160K50 Hz/60 Hz ± 10%
INVERTER
Admissible Crest Factor
Giant 10K3:1
Giant 15K3:1
Giant 20K3:1
Giant 30K3:1
Giant 40K3:1
Giant 60K3:1
Giant 80K3:1
Giant 100K3:1
Giant 120K3:1
Giant 160K3:1
Admissible Overload
Giant 10K110% ~ 150% 10 min ~ 60 sec; 150% ~ 160% 60 sec~ 200ms; >160% 200ms
Giant 15K110% ~ 150% 10 min ~ 60 sec; 150% ~ 160% 60 sec~ 200ms; >160% 200ms
Giant 20K110% ~ 150% 10 min ~ 60 sec; 150% ~ 160% 60 sec~ 200ms; >160% 200ms
Giant 30K110% ~ 150% 10 min ~ 60 sec; 150% ~ 160% 60 sec~ 200ms; >160% 200ms
Giant 40K110% ~ 150% 10 min ~ 60 sec; 150% ~ 160% 60 sec~ 200ms; >160% 200ms
Giant 60K110% ~ 150% 10 min ~ 60 sec; 150% ~ 160% 60 sec~ 200ms; >160% 200ms
Giant 80K110% ~ 150% 10 min ~ 60 sec; 150% ~ 160% 60 sec~ 200ms; >160% 200ms
Giant 100K110% ~ 150% 10 min ~ 60 sec; 150% ~ 160% 60 sec~ 200ms; >160% 200ms
Giant 120K110% ~ 150% 10 min ~ 60 sec; 150% ~ 160% 60 sec~ 200ms; >160% 200ms
Giant 160K110% ~ 150% 10 min ~ 60 sec; 150% ~ 160% 60 sec~ 200ms; >160% 200ms
Admissible Power Factor
Giant 10K0.6~1 (inductive or capacitive)
Giant 15K0.6~1 (inductive or capacitive)
Giant 20K0.6~1 (inductive or capacitive)
Giant 30K0.6~1 (inductive or capacitive)
Giant 40K0.6~1 (inductive or capacitive)
Giant 60K0.6~1 (inductive or capacitive)
Giant 80K0.6~1 (inductive or capacitive)
Giant 100K0.6~1 (inductive or capacitive)
Giant 120K0.6~1 (inductive or capacitive)
Giant 160K0.6~1 (inductive or capacitive)
Current Limit
Giant 10KHigh overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
Giant 15KHigh overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
Giant 20KHigh overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
Giant 30KHigh overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
Giant 40KHigh overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
Giant 60KHigh overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
Giant 80KHigh overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
Giant 100KHigh overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
Giant 120KHigh overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
Giant 160KHigh overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
Dynamic Recovery Time
Giant 10K3 cycles at 90 % of the static value
Giant 15K3 cycles at 90 % of the static value
Giant 20K3 cycles at 90 % of the static value
Giant 30K3 cycles at 90 % of the static value
Giant 40K3 cycles at 90 % of the static value
Giant 60K3 cycles at 90 % of the static value
Giant 80K3 cycles at 90 % of the static value
Giant 100K3 cycles at 90 % of the static value
Giant 120K3 cycles at 90 % of the static value
Giant 160K3 cycles at 90 % of the static value
Frequency
Giant 10K50/60 Hz synchronised ±1 %; With mains absent ±0.1 Hz
Giant 15K50/60 Hz synchronised ±1 %; With mains absent ±0.1 Hz
Giant 20K50/60 Hz synchronised ±1 %; With mains absent ±0.1 Hz
Giant 30K50/60 Hz synchronised ±1 %; With mains absent ±0.1 Hz
Giant 40K50/60 Hz synchronised ±1 %; With mains absent ±0.1 Hz
Giant 60K50/60 Hz synchronised ±1 %; With mains absent ±0.1 Hz
Giant 80K50/60 Hz synchronised ±1 %; With mains absent ±0.1 Hz
Giant 100K50/60 Hz synchronised ±1 %; With mains absent ±0.1 Hz
Giant 120K50/60 Hz synchronised ±1 %; With mains absent ±0.1 Hz
Giant 160K50/60 Hz synchronised ±1 %; With mains absent ±0.1 Hz
Imbalance Output Voltage @ 100% Unbalanced Load
Giant 10K<1%
Giant 15K<1%
Giant 20K<1%
Giant 30K<1%
Giant 40K<1%
Giant 60K<1%
Giant 80K<1%
Giant 100K<1%
Giant 120K<1%
Giant 160K<1%
Max. Synchronisation Speed
Giant 10K± 1Hz/s
Giant 15K± 1Hz/s
Giant 20K± 1Hz/s
Giant 30K± 1Hz/s
Giant 40K± 1Hz/s
Giant 60K± 1Hz/s
Giant 80K± 1Hz/s
Giant 100K± 1Hz/s
Giant 120K± 1Hz/s
Giant 160K± 1Hz/s
Nominal Voltage
Giant 10K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 15K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 20K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 30K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 40K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 60K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 80K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 100K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 120K3 x 380VAC/400VAC/415VAC (3Ph+N)
Giant 160K3 x 380VAC/400VAC/415VAC (3Ph+N)
Phase Displacement
Giant 10K120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load)
Giant 15K120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load)
Giant 20K120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load)
Giant 30K120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load)
Giant 40K120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load)
Giant 60K120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load)
Giant 80K120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load)
Giant 100K120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load)
Giant 120K120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load)
Giant 160K120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load)
Precision
Giant 10KStationary: ±1%; Transitory: ±5% (load variations 100-0-100%)
Giant 15KStationary: ±1%; Transitory: ±5% (load variations 100-0-100%)
Giant 20KStationary: ±1%; Transitory: ±5% (load variations 100-0-100%)
Giant 30KStationary: ±1%; Transitory: ±5% (load variations 100-0-100%)
Giant 40KStationary: ±1%; Transitory: ±5% (load variations 100-0-100%)
Giant 60KStationary: ±1%; Transitory: ±5% (load variations 100-0-100%)
Giant 80KStationary: ±1%; Transitory: ±5% (load variations 100-0-100%)
Giant 100KStationary: ±1%; Transitory: ±5% (load variations 100-0-100%)
Giant 120KStationary: ±1%; Transitory: ±5% (load variations 100-0-100%)
Giant 160KStationary: ±1%; Transitory: ±5% (load variations 100-0-100%)
Total Harmonic Distortion (THDv)
Giant 10K<2% (Linear Load); <5% (Non-linear Load)
Giant 15K<2% (Linear Load); <5% (Non-linear Load)
Giant 20K<2% (Linear Load); <5% (Non-linear Load)
Giant 30K<2% (Linear Load); <5% (Non-linear Load)
Giant 40K<2% (Linear Load); <5% (Non-linear Load)
Giant 60K<2% (Linear Load); <5% (Non-linear Load)
Giant 80K<2% (Linear Load); <5% (Non-linear Load)
Giant 100K<2% (Linear Load); <5% (Non-linear Load)
Giant 120K<2% (Linear Load); <5% (Non-linear Load)
Giant 160K<2% (Linear Load); <5% (Non-linear Load)
Waveform
Giant 10KPure Sine Wave
Giant 15KPure Sine Wave
Giant 20KPure Sine Wave
Giant 30KPure Sine Wave
Giant 40KPure Sine Wave
Giant 60KPure Sine Wave
Giant 80KPure Sine Wave
Giant 100KPure Sine Wave
Giant 120KPure Sine Wave
Giant 160KPure Sine Wave
STATIC BYPASS
Activation Criterion
Giant 10KMicroprocessor control
Giant 15KMicroprocessor control
Giant 20KMicroprocessor control
Giant 30KMicroprocessor control
Giant 40KMicroprocessor control
Giant 60KMicroprocessor control
Giant 80KMicroprocessor control
Giant 100KMicroprocessor control
Giant 120KMicroprocessor control
Giant 160KMicroprocessor control
Admissible Overload
Giant 10K0% ~ 150% continuous working; 150% ~ 180% 60 min~5 min; >180% 5 min
Giant 15K0% ~ 150% continuous working; 150% ~ 180% 60 min~5 min; >180% 5 min
Giant 20K0% ~ 150% continuous working; 150% ~ 180% 60 min~5 min; >180% 5 min
Giant 30K0% ~ 150% continuous working; 150% ~ 180% 60 min~5 min; >180% 5 min
Giant 40K0% ~ 150% continuous working; 150% ~ 180% 60 min~5 min; >180% 5 min
Giant 60K0% ~ 150% continuous working; 150% ~ 180% 60 min~5 min; >180% 5 min
Giant 80K0% ~ 150% continuous working; 150% ~ 180% 60 min~5 min; >180% 5 min
Giant 100K0% ~ 150% continuous working; 150% ~ 180% 60 min~5 min; >180% 5 min
Giant 120K0% ~ 150% continuous working; 150% ~ 180% 60 min~5 min; >180% 5 min
Giant 160K0% ~ 150% continuous working; 150% ~ 180% 60 min~5 min; >180% 5 min
Frequency
Giant 10K50 Hz/60 Hz ± 10%
Giant 15K50 Hz/60 Hz ± 10%
Giant 20K50 Hz/60 Hz ± 10%
Giant 30K50 Hz/60 Hz ± 10%
Giant 40K50 Hz/60 Hz ± 10%
Giant 60K50 Hz/60 Hz ± 10%
Giant 80K50 Hz/60 Hz ± 10%
Giant 100K50 Hz/60 Hz ± 10%
Giant 120K50 Hz/60 Hz ± 10%
Giant 160K50 Hz/60 Hz ± 10%
Retransfer
Giant 10KAutomatic after alarm clear
Giant 15KAutomatic after alarm clear
Giant 20KAutomatic after alarm clear
Giant 30KAutomatic after alarm clear
Giant 40KAutomatic after alarm clear
Giant 60KAutomatic after alarm clear
Giant 80KAutomatic after alarm clear
Giant 100KAutomatic after alarm clear
Giant 120KAutomatic after alarm clear
Giant 160KAutomatic after alarm clear
Transfer Time
Giant 10KZero
Giant 15KZero
Giant 20KZero
Giant 30KZero
Giant 40KZero
Giant 60KZero
Giant 80KZero
Giant 100KZero
Giant 120KZero
Giant 160KZero
Transfer to Bypass
Giant 10KImmediate, for overloads above 160%
Giant 15KImmediate, for overloads above 160%
Giant 20KImmediate, for overloads above 160%
Giant 30KImmediate, for overloads above 160%
Giant 40KImmediate, for overloads above 160%
Giant 60KImmediate, for overloads above 160%
Giant 80KImmediate, for overloads above 160%
Giant 100KImmediate, for overloads above 160%
Giant 120KImmediate, for overloads above 160%
Giant 160KImmediate, for overloads above 160%
Type
Giant 10KSolid state
Giant 15KSolid state
Giant 20KSolid state
Giant 30KSolid state
Giant 40KSolid state
Giant 60KSolid state
Giant 80KSolid state
Giant 100KSolid state
Giant 120KSolid state
Giant 160KSolid state
Voltage
Giant 10K176VAC~264VAC (Ph-N); 304VAC~456VAC (Ph-Ph)
Giant 15K176VAC~264VAC (Ph-N); 304VAC~456VAC (Ph-Ph)
Giant 20K176VAC~264VAC (Ph-N); 304VAC~456VAC (Ph-Ph)
Giant 30K176VAC~264VAC (Ph-N); 304VAC~456VAC (Ph-Ph)
Giant 40K176VAC~264VAC (Ph-N); 304VAC~456VAC (Ph-Ph)
Giant 60K176VAC~264VAC (Ph-N); 304VAC~456VAC (Ph-Ph)
Giant 80K176VAC~264VAC (Ph-N); 304VAC~456VAC (Ph-Ph)
Giant 100K176VAC~264VAC (Ph-N); 304VAC~456VAC (Ph-Ph)
Giant 120K176VAC~264VAC (Ph-N); 304VAC~456VAC (Ph-Ph)
Giant 160K176VAC~264VAC (Ph-N); 304VAC~456VAC (Ph-Ph)
MAINTENANCE BYPASS
Frequency
Giant 10K50 Hz/60 Hz
Giant 15K50 Hz/60 Hz
Giant 20K50 Hz/60 Hz
Giant 30K50 Hz/60 Hz
Giant 40K50 Hz/60 Hz
Giant 60K50 Hz/60 Hz
Giant 80K50 Hz/60 Hz
Giant 100K50 Hz/60 Hz
Giant 120K50 Hz/60 Hz
Giant 160K50 Hz/60 Hz
Overall Efficiency Battery Mode
Giant 10K90%
Giant 15K90%
Giant 20K91%
Giant 30K91%
Giant 40K92%
Giant 60K92%
Giant 80K93%
Giant 100K93%
Giant 120K93%
Giant 160K93%
Overall Efficiency Line Mode
Giant 10K89%
Giant 15K89%
Giant 20K90%
Giant 30K90%
Giant 40K91%
Giant 60K91%
Giant 80K92%
Giant 100K92%
Giant 120K92%
Giant 160K92%
Type
Giant 10KWithout interruption
Giant 15KWithout interruption
Giant 20KWithout interruption
Giant 30KWithout interruption
Giant 40KWithout interruption
Giant 60KWithout interruption
Giant 80KWithout interruption
Giant 100KWithout interruption
Giant 120KWithout interruption
Giant 160KWithout interruption
Voltage
Giant 10K3 x 400VAC(3Ph+N)
Giant 15K3 x 400VAC(3Ph+N)
Giant 20K3 x 400VAC(3Ph+N)
Giant 30K3 x 400VAC(3Ph+N)
Giant 40K3 x 400VAC(3Ph+N)
Giant 60K3 x 400VAC(3Ph+N)
Giant 80K3 x 400VAC(3Ph+N)
Giant 100K3 x 400VAC(3Ph+N)
Giant 120K3 x 400VAC(3Ph+N)
Giant 160K3 x 400VAC(3Ph+N)
BATTERY & CHARGER
Charging Method
Giant 10KCC/CV
Giant 15KCC/CV
Giant 20KCC/CV
Giant 30KCC/CV
Giant 40KCC/CV
Giant 60KCC/CV
Giant 80KCC/CV
Giant 100KCC/CV
Giant 120KCC/CV
Giant 160KCC/CV
Charging Voltage
Giant 10K432 VDC (Based on 32pcs batteries)
Giant 15K432 VDC (Based on 32pcs batteries)
Giant 20K432 VDC (Based on 32pcs batteries)
Giant 30K432 VDC (Based on 32pcs batteries)
Giant 40K432 VDC (Based on 32pcs batteries)
Giant 60K432 VDC (Based on 32pcs batteries)
Giant 80K432 VDC (Based on 32pcs batteries)
Giant 100K432 VDC (Based on 32pcs batteries)
Giant 120K432 VDC (Based on 32pcs batteries)
Giant 160K432 VDC (Based on 32pcs batteries)
Nominal Battery Voltage
Giant 10K384 VDC (Based on 32pcs batteries)
Giant 15K384 VDC (Based on 32pcs batteries)
Giant 20K384 VDC (Based on 32pcs batteries)
Giant 30K384 VDC (Based on 32pcs batteries)
Giant 40K384 VDC (Based on 32pcs batteries)
Giant 60K384 VDC (Based on 32pcs batteries)
Giant 80K384 VDC (Based on 32pcs batteries)
Giant 100K384 VDC (Based on 32pcs batteries)
Giant 120K384 VDC (Based on 32pcs batteries)
Giant 160K384 VDC (Based on 32pcs batteries)
Precision
Giant 10K± 1%
Giant 15K± 1%
Giant 20K± 1%
Giant 30K± 1%
Giant 40K± 1%
Giant 60K± 1%
Giant 80K± 1%
Giant 100K± 1%
Giant 120K± 1%
Giant 160K± 1%
Battery Type & Number
Giant 10K12 VDC x 32 pcs (29~32 pcs adjustable)
Giant 15K12 VDC x 32 pcs (29~32 pcs adjustable)
Giant 20K12 VDC x 32 pcs (29~32 pcs adjustable)
Giant 30K12 VDC x 32 pcs (29~32 pcs adjustable)
Giant 40K12 VDC x 32 pcs (29~32 pcs adjustable)
Giant 60K12 VDC x 32 pcs (29~32 pcs adjustable)
Giant 80K12 VDC x 32 pcs (29~32 pcs adjustable)
Giant 100K12 VDC x 32 pcs (29~32 pcs adjustable)
Giant 120K12 VDC x 32 pcs (29~32 pcs adjustable)
Giant 160K12 VDC x 32 pcs (29~32 pcs adjustable)
Charging Current
Giant 10KDefault 10A, *Maximum=Capacity(KW)/Battery Voltage(real-time).
Giant 15KDefault 10A, *Maximum=Capacity(KW)/Battery Voltage(real-time).
Giant 20KDefault 10A, *Maximum=Capacity(KW)/Battery Voltage(real-time).
Giant 30KDefault 10A; Maximum 40A; 5A@ full load
Giant 40KDefault 10A; Maximum 40A; 5A@ full load
Giant 60KDefault 10A; Maximum 40A; 5A@ full load
Giant 80KDefault 10A; Maximum 40A; 5A@ full load
Giant 100KDefault 10A; Maximum 40A; 5A@ full load
Giant 120KDefault 10A; Maximum 40A; 5A@ full load
Giant 160KDefault 10A; Maximum 40A; 5A@ full load
PHYSICAL
Dimension, D X W X H (mm)
Giant 10K656 x 405 x 817
Giant 15K656 x 405 x 817
Giant 20K656 x 405 x 817
Giant 30K656 x 405 x 941
Giant 40K821 x 432 x 1159
Giant 60K821 x 432 x 1159
Giant 80K975 x 554 x 1286
Giant 100K975 x 554 x 1286
Giant 120K975 x 635 x 1326
Giant 160K1051x705x1646
Net Weight (kgs)
Giant 10K118
Giant 15K120
Giant 20K145
Giant 30K193
Giant 40K278
Giant 60K365
Giant 80K471
Giant 100K573
Giant 120K650
Giant 160K760
Brochure Giant 3P/3P