Galleon X9 6KVA/10KVA Rack/Tower
DSP technology applied
Galleon X9 online series with UL certified. Ranging from 1KVA to 10KVA with 0.9 output power factor, its transformerless design provides compact footprint in rack/tower convertible design which facilitate installation.
Main Features
- True double-conversion
- DSP technology guarantees high performance
- Output Power Factor 0.9
- Rack/Tower design
- User-friendly and easy-shift LCD display
- Wide input voltage range (110-300 VAC)
- Active input power factor correction 0.99
- 50Hz/60Hz frequency converter mode
- Eco mode operation for energy saving (ECO)
- Emergency power off function (EPO)
- Generator compatible
- Charger capacity expansion to 4A for long-run models
- SNMP/USB/RS-232 communications
- 3-stage extendable charging design for optimized battery performance
- Isolation transformer is available
MODEL | Galleon X9 6K(L) | Galleon X9 ISO 6K(L) | Galleon X9 10K(L) | Galleon X9 ISO 10K(L) | |
CAPACITY | 6000 VA / 5400 W | 6000 VA / 5400 W | 10000 VA / 9000 W | 10000 VA / 9000 W | |
PHASE | Single phase with ground | Single phase with ground | Single phase with ground | Single phase with ground | |
INPUT | |||||
Voltage Range | 110-300 VAC at 50% load; 176 -300 VAC at 100% load | 110-300 VAC at 50% load; 176 -300 VAC at 100% load | 110-300 VAC at 50% load; 176 -300 VAC at 100% load | 110-300 VAC at 50% load; 176 -300 VAC at 100% load | |
Nominal Voltage | 200/208/220/230/240 VAC | 200/208/220/230/240 VAC | 200/208/220/230/240 VAC | 200/208/220/230/240 VAC | |
Frequency Range | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz | |
Power Factor | ≧ 0.99 @ 100% load | ≧ 0.99 @ 100% load | ≧ 0.99 @ 100% load | ≧ 0.99 @ 100% load | |
OUTPUT | |||||
AC Voltage Regulation | ± 1% | ± 3% | ± 1% | ± 3% | |
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |
Nominal Voltage | 200/208/220/230/240 VAC | 104 VAC x 2 / 208 VAC or 110 VAC x 2 / 220 VAC or 115 VAC x 2 / 230 VAC or 120 VAC x 2 / 240 VAC | 200/208/220/230/240 VAC | 104 VAC x 2 / 208 VAC or 110 VAC x 2 / 220 VAC or 115 VAC x 2 / 230 VAC or 120 VAC x 2 / 240 VAC | |
Current Crest Ratio | 3:1 (max.) | 3:1 (max.) | 3:1 (max.) | 3:1 (max.) | |
Harmonic Distortion | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear Load) | ≦ 3.5% THD (Linear Load); ≦ 7% THD (Non-linear Load) | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear Load) | ≦ 3.5% THD (Linear Load); ≦ 7% THD (Non-linear Load) | |
Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz | |
Transfer Time | |||||
Battery mode to Line mode | Zero | Zero | Zero | Zero | |
Bypass to Inverter | Zero | Zero | Zero | Zero | |
Inverter to Bypass | Zero | Zero | Zero | Zero | |
Line mode to Battery mode | Zero | Zero | Zero | Zero | |
Waveform (Batt. Mode) | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | |
EFFICIENCY | |||||
Battery Mode | 88% | 82% | 88% | 82% | |
ECO Mode | 96% | 87% | 96% | 87% | |
AC Mode | 91% | 85% | 91% | 85% | |
BATTERY | |||||
Long-run Model | Battery Type & Numbers | Depending on applications | Depending on applications | Depending on applications | Depending on applications |
Long-run Model | Charging Current (max.) | 4A | 4A | 4A | 4A |
Long-run Model | Float Charging Voltage | 273 VDC (based on battery numbers at 20 pcs) | 273 VDC (based on battery numbers at 20 pcs) | 273 VDC (based on battery numbers at 20 pcs) | 273 VDC (based on battery numbers at 20 pcs) |
Standard Model | Battery Type | 12 V / 7 AH | 12 V / 7 AH | 12 V / 9 AH | 12 V / 9 AH |
Standard Model | Charging Current (max.) | 1A | 1A | 1A | 1A |
Standard Model | Float Charging Voltage | 273 VDC (based on battery numbers at 20 pcs) | 273 VDC (based on battery numbers at 20 pcs) | 273 VDC (based on battery numbers at 20 pcs) | 273 VDC (based on battery numbers at 20 pcs) |
Standard Model | Numbers | 20 (18-20 pcs adjustable) | 20 (18-20 pcs adjustable) | 20 (18-20 pcs adjustable) | 20 (18-20 pcs adjustable) |
Standard Model | Typical Recharge Time | 7 hours recover to 90% capacity | 7 hours recover to 90% capacity | 9 hours recover to 90% capacity | 9 hours recover to 90% capacity |
INDICATORS | |||||
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | |
ALARM | |||||
Battery Mode | Sounding every 4 seconds | Sounding every 4 seconds | Sounding every 4 seconds | Sounding every 4 seconds | |
Low Battery | Sounding every second | Sounding every second | Sounding every second | Sounding every second | |
Overload | Sounding twice every second | Sounding twice every second | Sounding twice every second | Sounding twice every second | |
Fault | Continuously sounding | Continuously sounding | Continuously sounding | Continuously sounding | |
ENVIRONMENT | |||||
Operating Humidity | 0~95% RH @ 0- 40°C (non-condensing) | 0~95% RH @ 0- 40°C (non-condensing) | 0~95% RH @ 0- 40°C (non-condensing) | 0~95% RH @ 0- 40°C (non-condensing) | |
Noise Level | Less than 58dB @ 1 Meter | Less than 58dB @ 1 Meter | Less than 60dB @ 1 Meter | Less than 60dB @ 1 Meter | |
PHYSICAL | |||||
Standard Model | Dimension, D X W X H (mm) | UPS unit: 606 x 438 x 133 [3U]; Battery pack: 606X438 X133 [3U] | UPS unit: 606 x 438 x 133 [3U]; Battery pack: 606X438 X133 [3U]; ISO bank: 606 x 438 x 133 [3U] | UPS unit: 686 x 438 x 133 [3U]; Battery pack: 606 x 438 x 133 [3U] | UPS unit: 686 x 438 x 133 [3U]; Battery pack: 606 x 438 x 133 [3U]; ISO bank: 686 x 438 x 133 [3U] |
Standard Model | Net Weight (kgs) | UPS unit: 20; Battery pack: 58 | UPS unit: 20; Battery pack: 58/ ISO bank: 61 | UPS unit: 23.5; Battery pack: 65 | UPS unit: 23.5; Battery pack: 65 ; ISO bank: 90 |
Long-run Model | Dimension, D X W X H (mm) | 606 x 438 x 133 [3U] | UPS unit: 606 x 438 x 133 [3U]; ISO bank: 606 x 438 x 133 [3U] | 686 x 438 x 133 [3U] | UPS unit: 606 x 438 x 133 [3U]; ISO bank: 606 x 438 x 133 [3U] |
Long-run Model | Net Weight (kgs) | 20 | UPS unit: 20; ISO bank: 61 | 23.5 | UPS unit: 23.5; ISO bank: 90 |
MANAGEMENT | |||||
Optional SNMP | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | |
Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
General
CAPACITY
Galleon X9 6K(L) | 6000 VA / 5400 W |
---|---|
Galleon X9 ISO 6K(L) | 6000 VA / 5400 W |
Galleon X9 10K(L) | 10000 VA / 9000 W |
Galleon X9 ISO 10K(L) | 10000 VA / 9000 W |
PHASE
Galleon X9 6K(L) | Single phase with ground |
---|---|
Galleon X9 ISO 6K(L) | Single phase with ground |
Galleon X9 10K(L) | Single phase with ground |
Galleon X9 ISO 10K(L) | Single phase with ground |
INPUT
Voltage Range
Galleon X9 6K(L) | 110-300 VAC at 50% load; 176 -300 VAC at 100% load |
---|---|
Galleon X9 ISO 6K(L) | 110-300 VAC at 50% load; 176 -300 VAC at 100% load |
Galleon X9 10K(L) | 110-300 VAC at 50% load; 176 -300 VAC at 100% load |
Galleon X9 ISO 10K(L) | 110-300 VAC at 50% load; 176 -300 VAC at 100% load |
Nominal Voltage
Galleon X9 6K(L) | 200/208/220/230/240 VAC |
---|---|
Galleon X9 ISO 6K(L) | 200/208/220/230/240 VAC |
Galleon X9 10K(L) | 200/208/220/230/240 VAC |
Galleon X9 ISO 10K(L) | 200/208/220/230/240 VAC |
Frequency Range
Galleon X9 6K(L) | 46~54 Hz or 56~64 Hz |
---|---|
Galleon X9 ISO 6K(L) | 46~54 Hz or 56~64 Hz |
Galleon X9 10K(L) | 46~54 Hz or 56~64 Hz |
Galleon X9 ISO 10K(L) | 46~54 Hz or 56~64 Hz |
Power Factor
Galleon X9 6K(L) | ≧ 0.99 @ 100% load |
---|---|
Galleon X9 ISO 6K(L) | ≧ 0.99 @ 100% load |
Galleon X9 10K(L) | ≧ 0.99 @ 100% load |
Galleon X9 ISO 10K(L) | ≧ 0.99 @ 100% load |
OUTPUT
AC Voltage Regulation
Galleon X9 6K(L) | ± 1% |
---|---|
Galleon X9 ISO 6K(L) | ± 3% |
Galleon X9 10K(L) | ± 1% |
Galleon X9 ISO 10K(L) | ± 3% |
Frequency Range (Batt. Mode)
Galleon X9 6K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
---|---|
Galleon X9 ISO 6K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon X9 10K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon X9 ISO 10K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Nominal Voltage
Galleon X9 6K(L) | 200/208/220/230/240 VAC |
---|---|
Galleon X9 ISO 6K(L) | 104 VAC x 2 / 208 VAC or 110 VAC x 2 / 220 VAC or 115 VAC x 2 / 230 VAC or 120 VAC x 2 / 240 VAC |
Galleon X9 10K(L) | 200/208/220/230/240 VAC |
Galleon X9 ISO 10K(L) | 104 VAC x 2 / 208 VAC or 110 VAC x 2 / 220 VAC or 115 VAC x 2 / 230 VAC or 120 VAC x 2 / 240 VAC |
Current Crest Ratio
Galleon X9 6K(L) | 3:1 (max.) |
---|---|
Galleon X9 ISO 6K(L) | 3:1 (max.) |
Galleon X9 10K(L) | 3:1 (max.) |
Galleon X9 ISO 10K(L) | 3:1 (max.) |
Harmonic Distortion
Galleon X9 6K(L) | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear Load) |
---|---|
Galleon X9 ISO 6K(L) | ≦ 3.5% THD (Linear Load); ≦ 7% THD (Non-linear Load) |
Galleon X9 10K(L) | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear Load) |
Galleon X9 ISO 10K(L) | ≦ 3.5% THD (Linear Load); ≦ 7% THD (Non-linear Load) |
Frequency Range (Synchronized Range)
Galleon X9 6K(L) | 46~54 Hz or 56~64 Hz |
---|---|
Galleon X9 ISO 6K(L) | 46~54 Hz or 56~64 Hz |
Galleon X9 10K(L) | 46~54 Hz or 56~64 Hz |
Galleon X9 ISO 10K(L) | 46~54 Hz or 56~64 Hz |
Transfer Time
Battery mode to Line mode
Galleon X9 6K(L) | Zero |
---|---|
Galleon X9 ISO 6K(L) | Zero |
Galleon X9 10K(L) | Zero |
Galleon X9 ISO 10K(L) | Zero |
Bypass to Inverter
Galleon X9 6K(L) | Zero |
---|---|
Galleon X9 ISO 6K(L) | Zero |
Galleon X9 10K(L) | Zero |
Galleon X9 ISO 10K(L) | Zero |
Inverter to Bypass
Galleon X9 6K(L) | Zero |
---|---|
Galleon X9 ISO 6K(L) | Zero |
Galleon X9 10K(L) | Zero |
Galleon X9 ISO 10K(L) | Zero |
Line mode to Battery mode
Galleon X9 6K(L) | Zero |
---|---|
Galleon X9 ISO 6K(L) | Zero |
Galleon X9 10K(L) | Zero |
Galleon X9 ISO 10K(L) | Zero |
Waveform (Batt. Mode)
Galleon X9 6K(L) | Pure Sine Wave |
---|---|
Galleon X9 ISO 6K(L) | Pure Sine Wave |
Galleon X9 10K(L) | Pure Sine Wave |
Galleon X9 ISO 10K(L) | Pure Sine Wave |
EFFICIENCY
Battery Mode
Galleon X9 6K(L) | 88% |
---|---|
Galleon X9 ISO 6K(L) | 82% |
Galleon X9 10K(L) | 88% |
Galleon X9 ISO 10K(L) | 82% |
ECO Mode
Galleon X9 6K(L) | 96% |
---|---|
Galleon X9 ISO 6K(L) | 87% |
Galleon X9 10K(L) | 96% |
Galleon X9 ISO 10K(L) | 87% |
AC Mode
Galleon X9 6K(L) | 91% |
---|---|
Galleon X9 ISO 6K(L) | 85% |
Galleon X9 10K(L) | 91% |
Galleon X9 ISO 10K(L) | 85% |
BATTERY
Long-run Model Battery Type & Numbers
Galleon X9 6K(L) | Depending on applications |
---|---|
Galleon X9 ISO 6K(L) | Depending on applications |
Galleon X9 10K(L) | Depending on applications |
Galleon X9 ISO 10K(L) | Depending on applications |
Long-run Model Charging Current (max.)
Galleon X9 6K(L) | 4A |
---|---|
Galleon X9 ISO 6K(L) | 4A |
Galleon X9 10K(L) | 4A |
Galleon X9 ISO 10K(L) | 4A |
Long-run Model Float Charging Voltage
Galleon X9 6K(L) | 273 VDC (based on battery numbers at 20 pcs) |
---|---|
Galleon X9 ISO 6K(L) | 273 VDC (based on battery numbers at 20 pcs) |
Galleon X9 10K(L) | 273 VDC (based on battery numbers at 20 pcs) |
Galleon X9 ISO 10K(L) | 273 VDC (based on battery numbers at 20 pcs) |
Standard Model Battery Type
Galleon X9 6K(L) | 12 V / 7 AH |
---|---|
Galleon X9 ISO 6K(L) | 12 V / 7 AH |
Galleon X9 10K(L) | 12 V / 9 AH |
Galleon X9 ISO 10K(L) | 12 V / 9 AH |
Standard Model Charging Current (max.)
Galleon X9 6K(L) | 1A |
---|---|
Galleon X9 ISO 6K(L) | 1A |
Galleon X9 10K(L) | 1A |
Galleon X9 ISO 10K(L) | 1A |
Standard Model Float Charging Voltage
Galleon X9 6K(L) | 273 VDC (based on battery numbers at 20 pcs) |
---|---|
Galleon X9 ISO 6K(L) | 273 VDC (based on battery numbers at 20 pcs) |
Galleon X9 10K(L) | 273 VDC (based on battery numbers at 20 pcs) |
Galleon X9 ISO 10K(L) | 273 VDC (based on battery numbers at 20 pcs) |
Standard Model Numbers
Galleon X9 6K(L) | 20 (18-20 pcs adjustable) |
---|---|
Galleon X9 ISO 6K(L) | 20 (18-20 pcs adjustable) |
Galleon X9 10K(L) | 20 (18-20 pcs adjustable) |
Galleon X9 ISO 10K(L) | 20 (18-20 pcs adjustable) |
Standard Model Typical Recharge Time
Galleon X9 6K(L) | 7 hours recover to 90% capacity |
---|---|
Galleon X9 ISO 6K(L) | 7 hours recover to 90% capacity |
Galleon X9 10K(L) | 9 hours recover to 90% capacity |
Galleon X9 ISO 10K(L) | 9 hours recover to 90% capacity |
INDICATORS
LCD Panel
Galleon X9 6K(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
---|---|
Galleon X9 ISO 6K(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon X9 10K(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon X9 ISO 10K(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
ALARM
Battery Mode
Galleon X9 6K(L) | Sounding every 4 seconds |
---|---|
Galleon X9 ISO 6K(L) | Sounding every 4 seconds |
Galleon X9 10K(L) | Sounding every 4 seconds |
Galleon X9 ISO 10K(L) | Sounding every 4 seconds |
Low Battery
Galleon X9 6K(L) | Sounding every second |
---|---|
Galleon X9 ISO 6K(L) | Sounding every second |
Galleon X9 10K(L) | Sounding every second |
Galleon X9 ISO 10K(L) | Sounding every second |
Overload
Galleon X9 6K(L) | Sounding twice every second |
---|---|
Galleon X9 ISO 6K(L) | Sounding twice every second |
Galleon X9 10K(L) | Sounding twice every second |
Galleon X9 ISO 10K(L) | Sounding twice every second |
Fault
Galleon X9 6K(L) | Continuously sounding |
---|---|
Galleon X9 ISO 6K(L) | Continuously sounding |
Galleon X9 10K(L) | Continuously sounding |
Galleon X9 ISO 10K(L) | Continuously sounding |
ENVIRONMENT
Operating Humidity
Galleon X9 6K(L) | 0~95% RH @ 0- 40°C (non-condensing) |
---|---|
Galleon X9 ISO 6K(L) | 0~95% RH @ 0- 40°C (non-condensing) |
Galleon X9 10K(L) | 0~95% RH @ 0- 40°C (non-condensing) |
Galleon X9 ISO 10K(L) | 0~95% RH @ 0- 40°C (non-condensing) |
Noise Level
Galleon X9 6K(L) | Less than 58dB @ 1 Meter |
---|---|
Galleon X9 ISO 6K(L) | Less than 58dB @ 1 Meter |
Galleon X9 10K(L) | Less than 60dB @ 1 Meter |
Galleon X9 ISO 10K(L) | Less than 60dB @ 1 Meter |
PHYSICAL
Standard Model Dimension, D X W X H (mm)
Galleon X9 6K(L) | UPS unit: 606 x 438 x 133 [3U]; Battery pack: 606X438 X133 [3U] |
---|---|
Galleon X9 ISO 6K(L) | UPS unit: 606 x 438 x 133 [3U]; Battery pack: 606X438 X133 [3U]; ISO bank: 606 x 438 x 133 [3U] |
Galleon X9 10K(L) | UPS unit: 686 x 438 x 133 [3U]; Battery pack: 606 x 438 x 133 [3U] |
Galleon X9 ISO 10K(L) | UPS unit: 686 x 438 x 133 [3U]; Battery pack: 606 x 438 x 133 [3U]; ISO bank: 686 x 438 x 133 [3U] |
Standard Model Net Weight (kgs)
Galleon X9 6K(L) | UPS unit: 20; Battery pack: 58 |
---|---|
Galleon X9 ISO 6K(L) | UPS unit: 20; Battery pack: 58/ ISO bank: 61 |
Galleon X9 10K(L) | UPS unit: 23.5; Battery pack: 65 |
Galleon X9 ISO 10K(L) | UPS unit: 23.5; Battery pack: 65 ; ISO bank: 90 |
Long-run Model Dimension, D X W X H (mm)
Galleon X9 6K(L) | 606 x 438 x 133 [3U] |
---|---|
Galleon X9 ISO 6K(L) | UPS unit: 606 x 438 x 133 [3U]; ISO bank: 606 x 438 x 133 [3U] |
Galleon X9 10K(L) | 686 x 438 x 133 [3U] |
Galleon X9 ISO 10K(L) | UPS unit: 606 x 438 x 133 [3U]; ISO bank: 606 x 438 x 133 [3U] |
Long-run Model Net Weight (kgs)
Galleon X9 6K(L) | 20 |
---|---|
Galleon X9 ISO 6K(L) | UPS unit: 20; ISO bank: 61 |
Galleon X9 10K(L) | 23.5 |
Galleon X9 ISO 10K(L) | UPS unit: 23.5; ISO bank: 90 |
MANAGEMENT
Optional SNMP
Galleon X9 6K(L) | Power management from SNMP manager and web browser |
---|---|
Galleon X9 ISO 6K(L) | Power management from SNMP manager and web browser |
Galleon X9 10K(L) | Power management from SNMP manager and web browser |
Galleon X9 ISO 10K(L) | Power management from SNMP manager and web browser |
Smart RS-232/USB
Galleon X9 6K(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
---|---|
Galleon X9 ISO 6K(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon X9 10K(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon X9 ISO 10K(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Brochure | Galleon X9 6K-10KVA Rack/Tower _Brochure | |
Manual | Galleon X9 6-10K RT_manual | |
Manual | Galleon X9 6-10K RT_user manual standard cTUVus version | |
Manual | Galleon X9 6-10K-UL+ISO RT_user manual standard UL version |
Single phase - Online UPS Galleon X9 6KVA/10KVA Rack/Tower DSP technology applied
We have received your membership application and will reply as soon as within 24 hours, before that, please browse our website, thank you.