Galleon X9 6KVA/10KVA Rack/Tower
DSP technology applied
Galleon X9 online series with UL certified. Ranging from 1KVA to 10KVA with 0.9 output power factor, its transformerless design provides compact footprint in rack/tower convertible design which facilitate installation.
Main Features
  • True double-conversion
  • DSP technology guarantees high performance
  • Output Power Factor 0.9
  • Rack/Tower design
  • User-friendly and easy-shift LCD display
  • Wide input voltage range (110-300 VAC)
  • Active input power factor correction 0.99
  • 50Hz/60Hz frequency converter mode
  • Eco mode operation for energy saving (ECO)
  • Emergency power off function (EPO)
  • Generator compatible
  • Charger capacity expansion to 4A for long-run models
  • SNMP/USB/RS-232 communications
  • 3-stage extendable charging design for optimized battery performance
  • Isolation transformer is available
General
CAPACITY
Galleon X9 6K(L)6000 VA / 5400 W
Galleon X9 ISO 6K(L)6000 VA / 5400 W
Galleon X9 10K(L)10000 VA / 9000 W
Galleon X9 ISO 10K(L)10000 VA / 9000 W
PHASE
Galleon X9 6K(L)Single phase with ground
Galleon X9 ISO 6K(L)Single phase with ground
Galleon X9 10K(L)Single phase with ground
Galleon X9 ISO 10K(L)Single phase with ground
INPUT
Voltage Range
Galleon X9 6K(L)110-300 VAC at 50% load; 176 -300 VAC at 100% load
Galleon X9 ISO 6K(L)110-300 VAC at 50% load; 176 -300 VAC at 100% load
Galleon X9 10K(L)110-300 VAC at 50% load; 176 -300 VAC at 100% load
Galleon X9 ISO 10K(L)110-300 VAC at 50% load; 176 -300 VAC at 100% load
Nominal Voltage
Galleon X9 6K(L)200/208/220/230/240 VAC
Galleon X9 ISO 6K(L)200/208/220/230/240 VAC
Galleon X9 10K(L)200/208/220/230/240 VAC
Galleon X9 ISO 10K(L)200/208/220/230/240 VAC
Frequency Range
Galleon X9 6K(L)46~54 Hz or 56~64 Hz
Galleon X9 ISO 6K(L)46~54 Hz or 56~64 Hz
Galleon X9 10K(L)46~54 Hz or 56~64 Hz
Galleon X9 ISO 10K(L)46~54 Hz or 56~64 Hz
Power Factor
Galleon X9 6K(L)≧ 0.99 @ 100% load
Galleon X9 ISO 6K(L)≧ 0.99 @ 100% load
Galleon X9 10K(L)≧ 0.99 @ 100% load
Galleon X9 ISO 10K(L)≧ 0.99 @ 100% load
OUTPUT
AC Voltage Regulation
Galleon X9 6K(L)± 1%
Galleon X9 ISO 6K(L)± 3%
Galleon X9 10K(L)± 1%
Galleon X9 ISO 10K(L)± 3%
Frequency Range (Batt. Mode)
Galleon X9 6K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon X9 ISO 6K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon X9 10K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon X9 ISO 10K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Nominal Voltage
Galleon X9 6K(L)200/208/220/230/240 VAC
Galleon X9 ISO 6K(L)104 VAC x 2 / 208 VAC or 110 VAC x 2 / 220 VAC or 115 VAC x 2 / 230 VAC or 120 VAC x 2 / 240 VAC
Galleon X9 10K(L)200/208/220/230/240 VAC
Galleon X9 ISO 10K(L)104 VAC x 2 / 208 VAC or 110 VAC x 2 / 220 VAC or 115 VAC x 2 / 230 VAC or 120 VAC x 2 / 240 VAC
Current Crest Ratio
Galleon X9 6K(L)3:1 (max.)
Galleon X9 ISO 6K(L)3:1 (max.)
Galleon X9 10K(L)3:1 (max.)
Galleon X9 ISO 10K(L)3:1 (max.)
Harmonic Distortion
Galleon X9 6K(L)≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear Load)
Galleon X9 ISO 6K(L)≦ 3.5% THD (Linear Load); ≦ 7% THD (Non-linear Load)
Galleon X9 10K(L)≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear Load)
Galleon X9 ISO 10K(L)≦ 3.5% THD (Linear Load); ≦ 7% THD (Non-linear Load)
Frequency Range (Synchronized Range)
Galleon X9 6K(L)46~54 Hz or 56~64 Hz
Galleon X9 ISO 6K(L)46~54 Hz or 56~64 Hz
Galleon X9 10K(L)46~54 Hz or 56~64 Hz
Galleon X9 ISO 10K(L)46~54 Hz or 56~64 Hz
Transfer Time
Battery mode to Line mode
Galleon X9 6K(L)Zero
Galleon X9 ISO 6K(L)Zero
Galleon X9 10K(L)Zero
Galleon X9 ISO 10K(L)Zero
Bypass to Inverter
Galleon X9 6K(L)Zero
Galleon X9 ISO 6K(L)Zero
Galleon X9 10K(L)Zero
Galleon X9 ISO 10K(L)Zero
Inverter to Bypass
Galleon X9 6K(L)Zero
Galleon X9 ISO 6K(L)Zero
Galleon X9 10K(L)Zero
Galleon X9 ISO 10K(L)Zero
Line mode to Battery mode
Galleon X9 6K(L)Zero
Galleon X9 ISO 6K(L)Zero
Galleon X9 10K(L)Zero
Galleon X9 ISO 10K(L)Zero
Waveform (Batt. Mode)
Galleon X9 6K(L)Pure Sine Wave
Galleon X9 ISO 6K(L)Pure Sine Wave
Galleon X9 10K(L)Pure Sine Wave
Galleon X9 ISO 10K(L)Pure Sine Wave
EFFICIENCY
Battery Mode
Galleon X9 6K(L)88%
Galleon X9 ISO 6K(L)82%
Galleon X9 10K(L)88%
Galleon X9 ISO 10K(L)82%
ECO Mode
Galleon X9 6K(L)96%
Galleon X9 ISO 6K(L)87%
Galleon X9 10K(L)96%
Galleon X9 ISO 10K(L)87%
AC Mode
Galleon X9 6K(L)91%
Galleon X9 ISO 6K(L)85%
Galleon X9 10K(L)91%
Galleon X9 ISO 10K(L)85%
BATTERY
Long-run Model Battery Type & Numbers
Galleon X9 6K(L)Depending on applications
Galleon X9 ISO 6K(L)Depending on applications
Galleon X9 10K(L)Depending on applications
Galleon X9 ISO 10K(L)Depending on applications
Long-run Model Charging Current (max.)
Galleon X9 6K(L)4A
Galleon X9 ISO 6K(L)4A
Galleon X9 10K(L)4A
Galleon X9 ISO 10K(L)4A
Long-run Model Float Charging Voltage
Galleon X9 6K(L)273 VDC (based on battery numbers at 20 pcs)
Galleon X9 ISO 6K(L)273 VDC (based on battery numbers at 20 pcs)
Galleon X9 10K(L)273 VDC (based on battery numbers at 20 pcs)
Galleon X9 ISO 10K(L)273 VDC (based on battery numbers at 20 pcs)
Standard Model Battery Type
Galleon X9 6K(L)12 V / 7 AH
Galleon X9 ISO 6K(L)12 V / 7 AH
Galleon X9 10K(L)12 V / 9 AH
Galleon X9 ISO 10K(L)12 V / 9 AH
Standard Model Charging Current (max.)
Galleon X9 6K(L)1A
Galleon X9 ISO 6K(L)1A
Galleon X9 10K(L)1A
Galleon X9 ISO 10K(L)1A
Standard Model Float Charging Voltage
Galleon X9 6K(L)273 VDC (based on battery numbers at 20 pcs)
Galleon X9 ISO 6K(L)273 VDC (based on battery numbers at 20 pcs)
Galleon X9 10K(L)273 VDC (based on battery numbers at 20 pcs)
Galleon X9 ISO 10K(L)273 VDC (based on battery numbers at 20 pcs)
Standard Model Numbers
Galleon X9 6K(L)20 (18-20 pcs adjustable)
Galleon X9 ISO 6K(L)20 (18-20 pcs adjustable)
Galleon X9 10K(L)20 (18-20 pcs adjustable)
Galleon X9 ISO 10K(L)20 (18-20 pcs adjustable)
Standard Model Typical Recharge Time
Galleon X9 6K(L)7 hours recover to 90% capacity
Galleon X9 ISO 6K(L)7 hours recover to 90% capacity
Galleon X9 10K(L)9 hours recover to 90% capacity
Galleon X9 ISO 10K(L)9 hours recover to 90% capacity
INDICATORS
LCD Panel
Galleon X9 6K(L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Galleon X9 ISO 6K(L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Galleon X9 10K(L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Galleon X9 ISO 10K(L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode
Galleon X9 6K(L)Sounding every 4 seconds
Galleon X9 ISO 6K(L)Sounding every 4 seconds
Galleon X9 10K(L)Sounding every 4 seconds
Galleon X9 ISO 10K(L)Sounding every 4 seconds
Low Battery
Galleon X9 6K(L)Sounding every second
Galleon X9 ISO 6K(L)Sounding every second
Galleon X9 10K(L)Sounding every second
Galleon X9 ISO 10K(L)Sounding every second
Overload
Galleon X9 6K(L)Sounding twice every second
Galleon X9 ISO 6K(L)Sounding twice every second
Galleon X9 10K(L)Sounding twice every second
Galleon X9 ISO 10K(L)Sounding twice every second
Fault
Galleon X9 6K(L)Continuously sounding
Galleon X9 ISO 6K(L)Continuously sounding
Galleon X9 10K(L)Continuously sounding
Galleon X9 ISO 10K(L)Continuously sounding
ENVIRONMENT
Operating Humidity
Galleon X9 6K(L)0~95% RH @ 0- 40°C (non-condensing)
Galleon X9 ISO 6K(L)0~95% RH @ 0- 40°C (non-condensing)
Galleon X9 10K(L)0~95% RH @ 0- 40°C (non-condensing)
Galleon X9 ISO 10K(L)0~95% RH @ 0- 40°C (non-condensing)
Noise Level
Galleon X9 6K(L)Less than 58dB @ 1 Meter
Galleon X9 ISO 6K(L)Less than 58dB @ 1 Meter
Galleon X9 10K(L)Less than 60dB @ 1 Meter
Galleon X9 ISO 10K(L)Less than 60dB @ 1 Meter
PHYSICAL
Standard Model Dimension, D X W X H (mm)
Galleon X9 6K(L)UPS unit: 606 x 438 x 133 [3U]; Battery pack: 606X438 X133 [3U]
Galleon X9 ISO 6K(L)UPS unit: 606 x 438 x 133 [3U]; Battery pack: 606X438 X133 [3U]; ISO bank: 606 x 438 x 133 [3U]
Galleon X9 10K(L)UPS unit: 686 x 438 x 133 [3U]; Battery pack: 606 x 438 x 133 [3U]
Galleon X9 ISO 10K(L)UPS unit: 686 x 438 x 133 [3U]; Battery pack: 606 x 438 x 133 [3U]; ISO bank: 686 x 438 x 133 [3U]
Standard Model Net Weight (kgs)
Galleon X9 6K(L)UPS unit: 20; Battery pack: 58
Galleon X9 ISO 6K(L)UPS unit: 20; Battery pack: 58/ ISO bank: 61
Galleon X9 10K(L)UPS unit: 23.5; Battery pack: 65
Galleon X9 ISO 10K(L)UPS unit: 23.5; Battery pack: 65 ; ISO bank: 90
Long-run Model Dimension, D X W X H (mm)
Galleon X9 6K(L)606 x 438 x 133 [3U]
Galleon X9 ISO 6K(L)UPS unit: 606 x 438 x 133 [3U]; ISO bank: 606 x 438 x 133 [3U]
Galleon X9 10K(L)686 x 438 x 133 [3U]
Galleon X9 ISO 10K(L)UPS unit: 606 x 438 x 133 [3U]; ISO bank: 606 x 438 x 133 [3U]
Long-run Model Net Weight (kgs)
Galleon X9 6K(L)20
Galleon X9 ISO 6K(L)UPS unit: 20; ISO bank: 61
Galleon X9 10K(L)23.5
Galleon X9 ISO 10K(L)UPS unit: 23.5; ISO bank: 90
MANAGEMENT
Optional SNMP
Galleon X9 6K(L)Power management from SNMP manager and web browser
Galleon X9 ISO 6K(L)Power management from SNMP manager and web browser
Galleon X9 10K(L)Power management from SNMP manager and web browser
Galleon X9 ISO 10K(L)Power management from SNMP manager and web browser
Smart RS-232/USB
Galleon X9 6K(L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon X9 ISO 6K(L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon X9 10K(L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon X9 ISO 10K(L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC