Galleon Pro 3P/3P Rackmount
PF0.9 rackmount version online UPS
Galleon Pro is the high density version of Galleon series of double-conversion online UPS. With an output power factor 0.9 and 91% operating efficiency in online mode, its suitable for powering a wide range of devices such as servers, data center, industrial processes, telecommunication and security system. Besides, it is provided with input power factor correction function that helps to avoid any damage to the mains and also facilitate the connection of generator.
Main Features
  • True double-conversion
  • DSP technology guarantees high performance
  • Output power factor 0.9
  • Wide input voltage range (110-300 VAC)
  • Active power factor correction in all phases
  • 50Hz/60Hz frequency converter mode
  • ECO mode operation for energy saving
  • Accepts dual power inputs
  • Emergency power off function (EPO)
  • Generator compatible
  • SNMP+USB+RS-232 multiple communications
  • 3-stage extendable charging design for optimized battery performance
  • Adjustable battery numbers
  • Maintenance bypass available
  • Optional N+X parallel redundancy
  • Optional isolation transformer offers full isolation and complete common mode noise
General
CAPACITY
Galleon Pro 3/3-10KR (L)10000 VA / 9000 W
Galleon Pro 3/3-15KR (L)15000 VA / 13500 W
Galleon Pro 3/3-20KR (L)20000 VA / 18000 W
PHASE
Galleon Pro 3/3-10KR (L)3 phase in / 3 phase out
Galleon Pro 3/3-15KR (L)3 phase in / 3 phase out
Galleon Pro 3/3-20KR (L)3 phase in / 3 phase out
INPUT
Voltage Range
Galleon Pro 3/3-10KR (L)190-520 VAC (3-phase) @ 50% load; 305-478 VAC (3-phase) @ 100% load
Galleon Pro 3/3-15KR (L)190-520 VAC (3-phase) @ 50% load; 305-478 VAC (3-phase) @ 100% load
Galleon Pro 3/3-20KR (L)190-520 VAC (3-phase) @ 50% load; 305-478 VAC (3-phase) @ 100% load
Nominal Voltage
Galleon Pro 3/3-10KR (L)3 x 400 VAC (3Ph+N)
Galleon Pro 3/3-15KR (L)3 x 400 VAC (3Ph+N)
Galleon Pro 3/3-20KR (L)3 x 400 VAC (3Ph+N)
Frequency Range
Galleon Pro 3/3-10KR (L)46~54 Hz or 56~64Hz
Galleon Pro 3/3-15KR (L)46~54 Hz or 56~64Hz
Galleon Pro 3/3-20KR (L)46~54 Hz or 56~64Hz
Power Factor
Galleon Pro 3/3-10KR (L)≧ 0.99 @ 100% load
Galleon Pro 3/3-15KR (L)≧ 0.99 @ 100% load
Galleon Pro 3/3-20KR (L)≧ 0.99 @ 100% load
OUTPUT
Output Voltage
Galleon Pro 3/3-10KR (L)3 x 400 VAC (3Ph+N)
Galleon Pro 3/3-15KR (L)3 x 400 VAC (3Ph+N)
Galleon Pro 3/3-20KR (L)3 x 400 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode)
Galleon Pro 3/3-10KR (L)± 1%
Galleon Pro 3/3-15KR (L)± 1%
Galleon Pro 3/3-20KR (L)± 1%
Frequency Range (Batt. Mode)
Galleon Pro 3/3-10KR (L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon Pro 3/3-15KR (L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon Pro 3/3-20KR (L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Transfer Time AC Mode to Battery Mode
Galleon Pro 3/3-10KR (L)zero
Galleon Pro 3/3-15KR (L)zero
Galleon Pro 3/3-20KR (L)zero
Transfer Time Inverter to Bypass
Galleon Pro 3/3-10KR (L)zero
Galleon Pro 3/3-15KR (L)zero
Galleon Pro 3/3-20KR (L)zero
Waveform (Batt. Mode)
Galleon Pro 3/3-10KR (L)Pure Sine Wave
Galleon Pro 3/3-15KR (L)Pure Sine Wave
Galleon Pro 3/3-20KR (L)Pure Sine Wave
Current Crest Ratio
Galleon Pro 3/3-10KR (L)3:1 (max.)
Galleon Pro 3/3-15KR (L)3:1 (max.)
Galleon Pro 3/3-20KR (L)3:1 (max.)
Harmonic Distortion
Galleon Pro 3/3-10KR (L)≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load)
Galleon Pro 3/3-15KR (L)≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load)
Galleon Pro 3/3-20KR (L)≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load)
Frequency Range (Synchronized Range)
Galleon Pro 3/3-10KR (L)46~54Hz or 56~64Hz
Galleon Pro 3/3-15KR (L)46~54Hz or 56~64Hz
Galleon Pro 3/3-20KR (L)46~54Hz or 56~64Hz
EFFICIENCY
Battery Mode
Galleon Pro 3/3-10KR (L)86%
Galleon Pro 3/3-15KR (L)87%
Galleon Pro 3/3-20KR (L)87%
ECO Mode
Galleon Pro 3/3-10KR (L)96%
Galleon Pro 3/3-15KR (L)96%
Galleon Pro 3/3-20KR (L)96%
AC Mode
Galleon Pro 3/3-10KR (L)90.5%
Galleon Pro 3/3-15KR (L)91.0%
Galleon Pro 3/3-20KR (L)91.0%
BATTERY
Long-run Model Battery Type & Numbers
Galleon Pro 3/3-10KR (L)Depending on the capacity of external batteries
Galleon Pro 3/3-15KR (L)Depending on the capacity of external batteries
Galleon Pro 3/3-20KR (L)Depending on the capacity of external batteries
Long-run Model Charging Current (max.)
Galleon Pro 3/3-10KR (L)4A
Galleon Pro 3/3-15KR (L)4A
Galleon Pro 3/3-20KR (L)4A
Long-run Model Charging Voltage
Galleon Pro 3/3-10KR (L)273 VDC ± 1%
Galleon Pro 3/3-15KR (L)273 VDC ± 1%
Galleon Pro 3/3-20KR (L)273 VDC ± 1%
Standard Model Battery Type
Galleon Pro 3/3-10KR (L)12 V / 9 AH
Galleon Pro 3/3-15KR (L)12 V / 9 AH
Galleon Pro 3/3-20KR (L)12 V / 9 AH
Standard Model Charging Current (max.)
Galleon Pro 3/3-10KR (L)1A
Galleon Pro 3/3-15KR (L)2A
Galleon Pro 3/3-20KR (L)2A
Standard Model Charging Voltage
Galleon Pro 3/3-10KR (L)273 VDC ± 1%
Galleon Pro 3/3-15KR (L)273 VDC ± 1%
Galleon Pro 3/3-20KR (L)273 VDC ± 1%
Standard Model Numbers
Galleon Pro 3/3-10KR (L)20 pcs (18-20 pcs adjustable)
Galleon Pro 3/3-15KR (L)20 pcs (18-20 pcs adjustable) x 2 strings
Galleon Pro 3/3-20KR (L)20 pcs (18-20 pcs adjustable) x 2 strings
Standard Model Typical Recharge Time
Galleon Pro 3/3-10KR (L)9 hours recover to 90% capacity
Galleon Pro 3/3-15KR (L)9 hours recover to 90% capacity
Galleon Pro 3/3-20KR (L)9 hours recover to 90% capacity
INDICATORS
LCD Panel
Galleon Pro 3/3-10KR (L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Galleon Pro 3/3-15KR (L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Galleon Pro 3/3-20KR (L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode
Galleon Pro 3/3-10KR (L)Sounding every 4 seconds
Galleon Pro 3/3-15KR (L)Sounding every 4 seconds
Galleon Pro 3/3-20KR (L)Sounding every 4 seconds
Low Battery
Galleon Pro 3/3-10KR (L)Sounding every second
Galleon Pro 3/3-15KR (L)Sounding every second
Galleon Pro 3/3-20KR (L)Sounding every second
Overload
Galleon Pro 3/3-10KR (L)Sounding twice every second
Galleon Pro 3/3-15KR (L)Sounding twice every second
Galleon Pro 3/3-20KR (L)Sounding twice every second
Fault
Galleon Pro 3/3-10KR (L)Continuously sounding
Galleon Pro 3/3-15KR (L)Continuously sounding
Galleon Pro 3/3-20KR (L)Continuously sounding
ENVIRONMENT
Operating Humidity
Galleon Pro 3/3-10KR (L)0~95% RH @ 0- 40°C (non-condensing)
Galleon Pro 3/3-15KR (L)0~95% RH @ 0- 40°C (non-condensing)
Galleon Pro 3/3-20KR (L)0~95% RH @ 0- 40°C (non-condensing)
Noise Level
Galleon Pro 3/3-10KR (L)Less than 60dB @ 1 Meter
Galleon Pro 3/3-15KR (L)Less than 65dB @ 1 Meter
Galleon Pro 3/3-20KR (L)Less than 65dB @ 1 Meter
PHYSICAL
Standard Model Dimension, D X W X H (mm)
Galleon Pro 3/3-10KR (L)UPS: 668 x 438 x 266[6U]; Battery pack: 580 x 438 x 133[3U]
Galleon Pro 3/3-15KR (L)UPS: 668 x 438 x 266[6U]; Battery pack: 580 x 438 x 133[3U] x 2 pcs
Galleon Pro 3/3-20KR (L)UPS: 668 x 438 x 266[6U]; Battery pack: 580 x 438 x 133[3U] x 2 pcs
Standard Model Net Weight (kgs)
Galleon Pro 3/3-10KR (L)UPS: 42; Battery pack: 63
Galleon Pro 3/3-15KR (L)UPS: 45; Battery pack: 63*2
Galleon Pro 3/3-20KR (L)UPS: 45; Battery pack: 63*2
Long-run Model Dimension, D X W X H (mm)
Galleon Pro 3/3-10KR (L)668 x 438 x 266 [6U]
Galleon Pro 3/3-15KR (L)668 x 438 x 266 [6U]
Galleon Pro 3/3-20KR (L)668 x 438 x 266 [6U]
Long-run Model Net Weight (kgs)
Galleon Pro 3/3-10KR (L)42
Galleon Pro 3/3-15KR (L)45
Galleon Pro 3/3-20KR (L)45
MANAGEMENT
Optional SNMP
Galleon Pro 3/3-10KR (L)Power management from SNMP manager and web browser
Galleon Pro 3/3-15KR (L)Power management from SNMP manager and web browser
Galleon Pro 3/3-20KR (L)Power management from SNMP manager and web browser
Smart RS-232 / USB
Galleon Pro 3/3-10KR (L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon Pro 3/3-15KR (L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon Pro 3/3-20KR (L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Brochure Galleon Pro_3P/3P_Brochure
Manual Galleon Pro_3P/3P_Manual
Related Products