Galleon One 1KVA-10KVA
Premium featured Online UPS
With true double-conversion design, Galleon series provides powerful and overall protection to your sensitive devices. It can accept wider input voltage for harsh environment. Its perfect protection for your precious servers and workstations. For Galleon One with cTUVus or isolation transformer specs, please check our sales directly.
Main Features
  • True double-conversion
  • Output power factor 1
  • Built-in 2.8 touch LCD for comprehensive UPS status
  • Output voltage regulation 1%
  • 50Hz/60Hz frequency converter mode
  • Programmable power management outlets
  • Hot swappable battery design
  • ECO mode energy saving
  • Provides over voltage cut-off protection and surge immunity by MOV for full time equipment protection
  • High power factor charger up to 8A/12A capacity with very low ripple current when charging battery
  • Low input THDi to reduce power system pollution
  • Adjustable charging current via LCD panel
  • Optional HID Power Device USB Port
General
PHASE
Galleon One 1KSingle phase with ground
Galleon One 1.5KSingle phase with ground
Galleon One 2KSingle phase with ground
Galleon One 3KSingle phase with ground
Galleon One 6K(L)1 phase in / 1 phase out
Galleon One 10K (L)1 phase in / 1 phase out
CAPACITY*
Galleon One 1K1000 VA / 1000 W
Galleon One 1.5K1500 VA / 1500 W
Galleon One 2K2000 VA / 2000 W
Galleon One 3K3000 VA / 3000 W
Galleon One 6K(L)6000 VA / 6000 W
Galleon One 10K (L)10000 VA / 10000 W
INPUT
Voltage Range
Galleon One 1K55-150 VAC ± 3 % or 110-300 VAC ± 3 % at 50% load; 80-150 VAC ± 3 % or 160-300 VAC ± 3 % at 100% load
Galleon One 1.5K55-150 VAC ± 3 % or 110-300 VAC ± 3 % at 50% load; 80-150 VAC ± 3 % or 160-300 VAC ± 3 % at 100% load
Galleon One 2K55-150 VAC ± 3 % or 110-300 VAC ± 3 % at 50% load; 80-150 VAC ± 3 % or 160-300 VAC ± 3 % at 100% load
Galleon One 3K55-150 VAC ± 3 % or 110-300 VAC ± 3 % at 50% load; 80-150 VAC ± 3 % or 160-300 VAC ± 3 % at 100% load
Galleon One 6K(L)110-300 VAC ± 3 % at 50% load; 176~300 VAC ± 3 % at 100% load
Galleon One 10K (L)110-300 VAC ± 3 % at 50% load; 176~300 VAC ± 3 % at 100% load
Nominal Voltage
Galleon One 1K100/110/115/120 /127 VAC or 200/208/220/230/240 VAC
Galleon One 1.5K100/110/115/120 /127 VAC or 200/208/220/230/240 VAC
Galleon One 2K100/110/115/120 /127 VAC or 200/208/220/230/240 VAC
Galleon One 3K100/110/115/120 /127 VAC or 200/208/220/230/240 VAC
Galleon One 6K(L)208/220/230/240 VAC
Galleon One 10K (L)208/220/230/240 VAC
Frequency Range
Galleon One 1K40Hz~70Hz
Galleon One 1.5K40Hz~70Hz
Galleon One 2K40Hz~70Hz
Galleon One 3K40Hz~70Hz
Galleon One 6K(L)46~54 Hz or 56~64 Hz
Galleon One 10K (L)46~54 Hz or 56~64 Hz
Power Factor
Galleon One 1K≧ 0.99 @ Nominal Voltage (100% load)
Galleon One 1.5K≧ 0.99 @ Nominal Voltage (100% load)
Galleon One 2K≧ 0.99 @ Nominal Voltage (100% load)
Galleon One 3K≧ 0.99 @ Nominal Voltage (100% load)
Galleon One 6K(L)≧ 0.99 @ full load
Galleon One 10K (L)≧ 0.99 @ full load
Harmonic Distortion (THDi)
Galleon One 1K≦ 5%
Galleon One 1.5K≦ 5%
Galleon One 2K≦ 5%
Galleon One 3K≦ 5%
Galleon One 6K(L)< 4% @100% Load, < 6% @50% Load
Galleon One 10K (L)< 4% @100% Load, < 6% @50% Load
OUTPUT
Output Voltage
Galleon One 1K100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC
Galleon One 1.5K100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC
Galleon One 2K100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC
Galleon One 3K100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC
Galleon One 6K(L)208/220/230/240 VAC
Galleon One 10K (L)208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode)
Galleon One 1K± 1%
Galleon One 1.5K± 1%
Galleon One 2K± 1%
Galleon One 3K± 1%
Galleon One 6K(L)± 1%
Galleon One 10K (L)± 1%
Frequency Range (Batt. Mode)
Galleon One 1K50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon One 1.5K50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon One 2K50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon One 3K50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon One 6K(L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon One 10K (L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Transfer Time AC to DC
Galleon One 1KZero
Galleon One 1.5KZero
Galleon One 2KZero
Galleon One 3KZero
Galleon One 6K(L)Zero
Galleon One 10K (L)Zero
Transfer Time ECO to Battery mode
Galleon One 1K8 ms (Typical), 10 ms(max)
Galleon One 1.5K8 ms (Typical), 10 ms(max)
Galleon One 2K8 ms (Typical), 10 ms(max)
Galleon One 3K8 ms (Typical), 10 ms(max)
Galleon One 6K(L)
Galleon One 10K (L)
Transfer Time Inverter to Bypass
Galleon One 1K4 ms (Typical)
Galleon One 1.5K4 ms (Typical)
Galleon One 2K4 ms (Typical)
Galleon One 3K4 ms (Typical)
Galleon One 6K(L)zero
Galleon One 10K (L)zero
Waveform (Batt. Mode)
Galleon One 1KPure Sine Wave
Galleon One 1.5KPure Sine Wave
Galleon One 2KPure Sine Wave
Galleon One 3KPure Sine Wave
Galleon One 6K(L)Pure Sine Wave
Galleon One 10K (L)Pure Sine Wave
Current Crest Ratio
Galleon One 1K3:1
Galleon One 1.5K3:1
Galleon One 2K3:1
Galleon One 3K3:1
Galleon One 6K(L)3:1 (max.)
Galleon One 10K (L)3:1 (max.)
Harmonic Distortion
Galleon One 1K≦ 2% THD (Linear Load) ; ≦ 4% THD (Non-linear Load)
Galleon One 1.5K≦ 2% THD (Linear Load) ; ≦ 4% THD (Non-linear Load)
Galleon One 2K≦ 2% THD (Linear Load) ; ≦ 4% THD (Non-linear Load)
Galleon One 3K≦ 2% THD (Linear Load) ; ≦ 4% THD (Non-linear Load)
Galleon One 6K(L)≦ 1% THD (Linear Load), ≦ 4% THD (Non-linear Load)
Galleon One 10K (L)≦ 1% THD (Linear Load), ≦ 4% THD (Non-linear Load)
Frequency Range (Synchronized Range)
Galleon One 1K47~53 Hz or 57~63Hz
Galleon One 1.5K47~53 Hz or 57~63Hz
Galleon One 2K47~53 Hz or 57~63Hz
Galleon One 3K47~53 Hz or 57~63Hz
Galleon One 6K(L)46~54 Hz or 56~64 Hz
Galleon One 10K (L)46~54 Hz or 56~64 Hz
Overload AC Mode
Galleon One 1K
Galleon One 1.5K
Galleon One 2K
Galleon One 3K
Galleon One 6K(L)100%~110%: 10min ; 110%~130%: 1min ; >130% : 1sec
Galleon One 10K (L)100%~110%: 10min ; 110%~130%: 1min ; >130% : 1sec
Overload Battery Mode
Galleon One 1K
Galleon One 1.5K
Galleon One 2K
Galleon One 3K
Galleon One 6K(L)100%~110%: 30sec ; 110%~130%: 10sec ; >130% : 1sec
Galleon One 10K (L)100%~110%: 30sec ; 110%~130%: 10sec ; >130% : 1sec
EFFICIENCY
Battery Mode
Galleon One 1K≧88%
Galleon One 1.5K≧88%
Galleon One 2K≧90%
Galleon One 3K≧90%
Galleon One 6K(L)91%
Galleon One 10K (L)91%
ECO Mode
Galleon One 1K≧ 96% @ full charged battery
Galleon One 1.5K≧ 96% @ full charged battery
Galleon One 2K≧ 96% @ full charged battery
Galleon One 3K≧ 96% @ full charged battery
Galleon One 6K(L)
Galleon One 10K (L)
AC Mode
Galleon One 1K≧ 89% @ full charged battery
Galleon One 1.5K≧ 89% @ full charged battery
Galleon One 2K≧ 91% @ full charged battery
Galleon One 3K≧ 91% @ full charged battery
Galleon One 6K(L)94%
Galleon One 10K (L)94%
BATTERY
Long-run Model Battery Type
Galleon One 1K
Galleon One 1.5K
Galleon One 2K
Galleon One 3K
Galleon One 6K(L)Depending on applications
Galleon One 10K (L)Depending on applications
Long-run Model Charging Current (max.)
Galleon One 1K
Galleon One 1.5K
Galleon One 2K
Galleon One 3K
Galleon One 6K(L)4.0 A
Galleon One 10K (L)4.0 A
Long-run Model Charging Voltage
Galleon One 1K
Galleon One 1.5K
Galleon One 2K
Galleon One 3K
Galleon One 6K(L)(13.65VDC x battery number) ± 1%
Galleon One 10K (L)(13.65VDC x battery number) ± 1%
Long-run Model Numbers
Galleon One 1K
Galleon One 1.5K
Galleon One 2K
Galleon One 3K
Galleon One 6K(L)16-20**
Galleon One 10K (L)16-20**
Standard Model Battery Type
Galleon One 1K12 V / 9 AH, 12 V / 7 AH
Galleon One 1.5K12 V / 9 AH
Galleon One 2K12 V / 9 AH, 12 V / 7 AH
Galleon One 3K12 V / 9 AH, 12 V / 7 AH
Galleon One 6K(L)12 V / 7 AH
Galleon One 10K (L)12 V / 9 AH
Standard Model Charging Current
Galleon One 1K100/110/115/120 /127 VAC models: default 2A, max. 8A adjustable; 200/208/220/230/240 VAC models: default 2A, max. 12A adjustable
Galleon One 1.5K100/110/115/120 /127 VAC models: default 2A, max. 8A adjustable; 200/208/220/230/240 VAC models: default 2A, max. 12A adjustable
Galleon One 2K100/110/115/120 /127 VAC models: default 2A, max. 8A adjustable; 200/208/220/230/240 VAC models: default 2A, max. 12A adjustable
Galleon One 3KDefault: 2A, Max: 8A adjustable
Galleon One 6K(L)1.0 A
Galleon One 10K (L)1.0 A
Standard Model Charging Voltage
Galleon One 1K27.4 VDC ± 1%,41.1 VDC ± 1%
Galleon One 1.5K41.1 VDC ± 1%
Galleon One 2K54.8 VDC ± 1%, 82.1 VDC ± 1%
Galleon One 3K82.1 VDC ± 1% ,109.6 VDC ± 1%
Galleon One 6K(L)218.4 VDC ± 1%
Galleon One 10K (L)218.4 VDC ± 1%
Standard Model Numbers
Galleon One 1K2,3
Galleon One 1.5K3
Galleon One 2K4, 6
Galleon One 3K6, 8
Galleon One 6K(L)16
Galleon One 10K (L)16
Standard Model Typical Recharge Time
Galleon One 1K3 hours recover to 95% capacity for internal battery@ 2A charging current
Galleon One 1.5K3 hours recover to 95% capacity for internal battery@ 2A charging current
Galleon One 2K3 hours recover to 95% capacity for internal battery@ 2A charging current
Galleon One 3K3 hours recover to 95% capacity for internal battery@ 2A charging current
Galleon One 6K(L)9 hours recover to 90% capacity
Galleon One 10K (L)9 hours recover to 90% capacity
INDICATORS
LCD Panel
Galleon One 1KLoad level, Battery level, AC mode, Battery Mode, Bypass mode, and Fault conditions
Galleon One 1.5KLoad level, Battery level, AC mode, Battery Mode, Bypass mode, and Fault conditions
Galleon One 2KLoad level, Battery level, AC mode, Battery Mode, Bypass mode, and Fault conditions
Galleon One 3KLoad level, Battery level, AC mode, Battery Mode, Bypass mode, and Fault conditions
Galleon One 6K(L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Galleon One 10K (L)UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode
Galleon One 1KSounding every 5 seconds
Galleon One 1.5KSounding every 5 seconds
Galleon One 2KSounding every 5 seconds
Galleon One 3KSounding every 5 seconds
Galleon One 6K(L)Sounding every 4 seconds
Galleon One 10K (L)Sounding every 4 seconds
Low Battery
Galleon One 1KSounding every 2 seconds
Galleon One 1.5KSounding every 2 seconds
Galleon One 2KSounding every 2 seconds
Galleon One 3KSounding every 2 seconds
Galleon One 6K(L)Sounding every 2 seconds
Galleon One 10K (L)Sounding every 2 seconds
Overload
Galleon One 1KSounding every second
Galleon One 1.5KSounding every second
Galleon One 2KSounding every second
Galleon One 3KSounding every second
Galleon One 6K(L)Sounding twice every second
Galleon One 10K (L)Sounding twice every second
Fault
Galleon One 1KContinuously sounding
Galleon One 1.5KContinuously sounding
Galleon One 2KContinuously sounding
Galleon One 3KContinuously sounding
Galleon One 6K(L)Continuously sounding
Galleon One 10K (L)Continuously sounding
ENVIRONMENT
Operating Humidity
Galleon One 1K20~95% RH @ 0- 40°C (non-condensing)
Galleon One 1.5K20~95% RH @ 0- 40°C (non-condensing)
Galleon One 2K20~95% RH @ 0- 40°C (non-condensing)
Galleon One 3K20~95% RH @ 0- 40°C (non-condensing)
Galleon One 6K(L)20~95% RH @ 0- 40°C (non-condensing)
Galleon One 10K (L)20~95% RH @ 0- 40°C (non-condensing)
Noise Level
Galleon One 1KLess than 50dB @ 1 Meter with Fan speed control
Galleon One 1.5KLess than 50dB @ 1 Meter with Fan speed control
Galleon One 2KLess than 50dB @ 1 Meter with Fan speed control
Galleon One 3KLess than 50dB @ 1 Meter with Fan speed control
Galleon One 6K(L)Less than 55dB @ 1 Meter
Galleon One 10K (L)Less than 58dB @ 1 Meter
PHYSICAL
Standard Model Dimension, D X W X H (mm)
Galleon One 1K397 x 145 x 220
Galleon One 1.5K397 x 145 x 220
Galleon One 2K421 x 190 x 318
Galleon One 3K421 x 190 x 318
Galleon One 6K(L)369 x 190 x 688
Galleon One 10K (L)442 x 190 x 688
Standard Model Net Weight (w/built-in battery) (kgs)
Galleon One 1K11.7, 13
Galleon One 1.5K14.6
Galleon One 2K20.3, 23.2
Galleon One 3K28, 33
Galleon One 6K(L)54
Galleon One 10K (L)66
Long-run Model Dimension, D X W X H (mm)
Galleon One 1K397 x 145 x 220
Galleon One 1.5K397 x 145 x 220
Galleon One 2K421 x 190 x 318
Galleon One 3K421 x 190 x 318
Galleon One 6K(L)369 x 190 x 318
Galleon One 10K (L)442 x 190 x 318
Long-run Model Net Weight (without battery) (kgs)
Galleon One 1K6.6
Galleon One 1.5K7
Galleon One 2K9.9
Galleon One 3K12.3
Galleon One 6K(L)13
Galleon One 10K (L)16
MANAGEMENT
Optional SNMP
Galleon One 1KPower management from SNMP manager and web browser
Galleon One 1.5KPower management from SNMP manager and web browser
Galleon One 2KPower management from SNMP manager and web browser
Galleon One 3KPower management from SNMP manager and web browser
Galleon One 6K(L)Power management from SNMP manager and web browser
Galleon One 10K (L)Power management from SNMP manager and web browser
Smart RS-232/USB
Galleon One 1KSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon One 1.5KSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon One 2KSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon One 3KSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon One 6K(L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon One 10K (L)Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
STANDARDS
Safety
Galleon One 1KEMC EN62040-2 C2 for CE models
Galleon One 1.5KEMC EN62040-2 C2 for CE models
Galleon One 2KEMC EN62040-2 C2 for CE models
Galleon One 3KEMC EN62040-2 C2 for CE models
Galleon One 6K(L)
Galleon One 10K (L)
*Derate capacity to 80% when the output voltage is adjusted to 100VAC.
**The output power factor is based on the input voltage. This figure is based on 127V input voltage.
***cTUVus is available for 1K/ 1.5K/ 2K/ 3K.
Brochure GalleonOne-1K-10K
Manual GalleonOne 1-3K
Manual GalleonOne-6-10K