Galleon III 3P/3P & 3P/1P & 1P/1P Tower 10KL-20KL
PF1 high-frequency Online UPS
The Galleon III 3P/3P, 3P/1P, and 1P/1P Tower (10KL–20KL) is a true double-conversion UPS designed to provide outstanding performance and reliability for critical power needs. Utilizing advanced DSP technology and offering a unity output power factor of 1.0, it delivers high efficiency and stable system operation. The UPS supports flexible configurations—3-phase input/3-phase output, 3-phase input/single-phase output, or single-phase input/single-phase output—to accommodate various installation requirements. Built for energy efficiency and operational versatility, the Galleon III includes active power factor correction, dual AC inputs, and an ECO mode. It also features frequency converter mode (50Hz/60Hz), compatibility with generators, and customizable battery setups for extended runtime models. For enhanced scalability and redundancy, up to four units can be connected in parallel, sharing a common battery bank, making it a dependable solution for mission-critical applications.
Main Features
- True double-conversion online UPS
- Versatile system setup options: 3 inputs/3 outputs, 3 inputs/1 output, or 1 input/1 output
- High performance ensured by DSP technology
- Output power factor of 1.0
- Active power factor correction across all phases
- Frequency converter mode supporting 50Hz and 60Hz
- Energy-saving ECO mode operation
- Dual AC input sources
- Emergency power off (EPO) feature
- Compatible with generators
- Adjustable number of batteries for extended runtime models
- Supports parallel operation of up to 4 units sharing a common battery
| MODEL | Galleon III 33/31/11 10K(L) Tower | Galleon III 33/31/11 20K(L) Tower | |
| CAPACITY | 10 KVA / 10 KW | 20KVA/20KW | |
| PHASE | 3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph out | 3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph out | |
| PARALLEL CAPABILITY | 4 | 4 | |
| INPUT | |||
| Voltage Range | 190-520 VAC @ 50% load; 305-478 VAC @ 100% load | 190-520 VAC @ 50% load; 305-478 VAC @ 100% load | |
| Nominal Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) | |
| Frequency Range | 46~54 Hz or 56~64Hz | 46~54 Hz or 56~64Hz | |
| Power Factor | ≧ 0.99 @ 100% load | ≧ 0.99 @ 100% load | |
| OUTPUT | |||
| Output Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) | |
| AC Voltage Regulation (Batt. Mode) | ± 1% | ± 1% | |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |
| Transfer Time | AC Mode to Battery Mode | zero | zero |
| Transfer Time | Inverter to Bypass | zero | zero |
| Waveform (Batt. Mode) | Pure Sine Wave | Pure Sine Wave | |
| Current Crest Ratio | 3:1 (max.) | 3:1 (max.) | |
| Harmonic Distortion | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) | |
| Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz | |
| Overload | AC Mode | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
| Overload | Battery Mode | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
| EFFICIENCY | |||
| Battery Mode | 95.5% | 0.96 | |
| ECO Mode | 98.5% | 98.5% | |
| AC Mode | 94.5% | 0.955 | |
| BYPASS | |||
| Overload Capability | > 130% 1 minute (default) ; continuously working until breaker protection (optional) | > 130% 1 minute (default) ; continuously working until breaker protection (optional) | |
| Nominal Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC(1Ph+N) | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC(1Ph+N) | |
| Voltage Range | 305 VAC ~ 457 VAC | 305 VAC ~ 457 VAC | |
| Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz | |
| BATTERY | |||
| Long-run Model | Model-Battery Type | Depending on the capacity of external batteries | Depending on the capacity of external batteries |
| Long-run Model | Model-Charging Current (max.) | 1A ~ 12A (Adjustable) | 1A ~ 12A (Adjustable) |
| Long-run Model | Model-Charging Voltage | +/-13.65V*N (N=8~10) | +/-13.65V*N (N=16~20) |
| Standard Model | Battery Type | 12V/9Ah | 12V/9Ah |
| Standard Model | Charging Current (max.) | 1A (Default) | 1A (Default) |
| Standard Model | Charging Voltage | +/-136.5 VDC ± 10% | +/-218 VDC ± 10% |
| Standard Model | Numbers | (10+10)pcs | (16+16)pcs |
| Standard Model | Typical Recharge Time | 9 hours recover to 90% capacity | 9 hours recover to 90% capacity |
| INDICATORS | |||
| LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | |
| ENVIRONMENT | |||
| Operating Temperature | 0~40°C | 0~40°C | |
| Operating Humidity | <95% and non-condersing | <95% and non-condersing | |
| Noise Level | Less than 62dB @ 1 Meter | Less than 65dB @ 1 Meter | |
| PHYSICAL | |||
| Standard Model | Dimension, D X W X H (mm) | 630 x 250 x 826 | 630 x 250 x 826 |
| Standard Model | Net Weight (kgs) | 80 | 133 |
| Long-run Model | Dimension, D X W X H (mm) | 630 x 250 x 826 | 630 x 250 x 826 |
| Long-run Model | Net Weight (kgs) | 25 | 37 |
| MANAGEMENT | |||
| Optional SNMP | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | |
| Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® family, Linux and MAC | |
General
CAPACITY
| Galleon III 33/31/11 10K(L) Tower | 10 KVA / 10 KW |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 20KVA/20KW |
PHASE
| Galleon III 33/31/11 10K(L) Tower | 3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph out |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph out |
PARALLEL CAPABILITY
| Galleon III 33/31/11 10K(L) Tower | 4 |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 4 |
INPUT
Voltage Range
| Galleon III 33/31/11 10K(L) Tower | 190-520 VAC @ 50% load; 305-478 VAC @ 100% load |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 190-520 VAC @ 50% load; 305-478 VAC @ 100% load |
Nominal Voltage
| Galleon III 33/31/11 10K(L) Tower | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) |
Frequency Range
| Galleon III 33/31/11 10K(L) Tower | 46~54 Hz or 56~64Hz |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 46~54 Hz or 56~64Hz |
Power Factor
| Galleon III 33/31/11 10K(L) Tower | ≧ 0.99 @ 100% load |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | ≧ 0.99 @ 100% load |
OUTPUT
Output Voltage
| Galleon III 33/31/11 10K(L) Tower | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) |
AC Voltage Regulation (Batt. Mode)
| Galleon III 33/31/11 10K(L) Tower | ± 1% |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | ± 1% |
Frequency Range (Batt. Mode)
| Galleon III 33/31/11 10K(L) Tower | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Transfer Time AC Mode to Battery Mode
| Galleon III 33/31/11 10K(L) Tower | zero |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | zero |
Transfer Time Inverter to Bypass
| Galleon III 33/31/11 10K(L) Tower | zero |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | zero |
Waveform (Batt. Mode)
| Galleon III 33/31/11 10K(L) Tower | Pure Sine Wave |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | Pure Sine Wave |
Current Crest Ratio
| Galleon III 33/31/11 10K(L) Tower | 3:1 (max.) |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 3:1 (max.) |
Harmonic Distortion
| Galleon III 33/31/11 10K(L) Tower | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) |
Frequency Range (Synchronized Range)
| Galleon III 33/31/11 10K(L) Tower | 46~54Hz or 56~64Hz |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 46~54Hz or 56~64Hz |
Overload AC Mode
| Galleon III 33/31/11 10K(L) Tower | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
Overload Battery Mode
| Galleon III 33/31/11 10K(L) Tower | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
EFFICIENCY
Battery Mode
| Galleon III 33/31/11 10K(L) Tower | 95.5% |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 0.96 |
ECO Mode
| Galleon III 33/31/11 10K(L) Tower | 98.5% |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 98.5% |
AC Mode
| Galleon III 33/31/11 10K(L) Tower | 94.5% |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 0.955 |
BYPASS
Overload Capability
| Galleon III 33/31/11 10K(L) Tower | > 130% 1 minute (default) ; continuously working until breaker protection (optional) |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | > 130% 1 minute (default) ; continuously working until breaker protection (optional) |
Nominal Voltage
| Galleon III 33/31/11 10K(L) Tower | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC(1Ph+N) |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC(1Ph+N) |
Voltage Range
| Galleon III 33/31/11 10K(L) Tower | 305 VAC ~ 457 VAC |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 305 VAC ~ 457 VAC |
Frequency Range (Synchronized Range)
| Galleon III 33/31/11 10K(L) Tower | 46~54Hz or 56~64Hz |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 46~54Hz or 56~64Hz |
BATTERY
Long-run Model Model-Battery Type
| Galleon III 33/31/11 10K(L) Tower | Depending on the capacity of external batteries |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | Depending on the capacity of external batteries |
Long-run Model Model-Charging Current (max.)
| Galleon III 33/31/11 10K(L) Tower | 1A ~ 12A (Adjustable) |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 1A ~ 12A (Adjustable) |
Long-run Model Model-Charging Voltage
| Galleon III 33/31/11 10K(L) Tower | +/-13.65V*N (N=8~10) |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | +/-13.65V*N (N=16~20) |
Standard Model Battery Type
| Galleon III 33/31/11 10K(L) Tower | 12V/9Ah |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 12V/9Ah |
Standard Model Charging Current (max.)
| Galleon III 33/31/11 10K(L) Tower | 1A (Default) |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 1A (Default) |
Standard Model Charging Voltage
| Galleon III 33/31/11 10K(L) Tower | +/-136.5 VDC ± 10% |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | +/-218 VDC ± 10% |
Standard Model Numbers
| Galleon III 33/31/11 10K(L) Tower | (10+10)pcs |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | (16+16)pcs |
Standard Model Typical Recharge Time
| Galleon III 33/31/11 10K(L) Tower | 9 hours recover to 90% capacity |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 9 hours recover to 90% capacity |
INDICATORS
LCD Panel
| Galleon III 33/31/11 10K(L) Tower | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
ENVIRONMENT
Operating Temperature
| Galleon III 33/31/11 10K(L) Tower | 0~40°C |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 0~40°C |
Operating Humidity
| Galleon III 33/31/11 10K(L) Tower | <95% and non-condersing |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | <95% and non-condersing |
Noise Level
| Galleon III 33/31/11 10K(L) Tower | Less than 62dB @ 1 Meter |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | Less than 65dB @ 1 Meter |
PHYSICAL
Standard Model Dimension, D X W X H (mm)
| Galleon III 33/31/11 10K(L) Tower | 630 x 250 x 826 |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 630 x 250 x 826 |
Standard Model Net Weight (kgs)
| Galleon III 33/31/11 10K(L) Tower | 80 |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 133 |
Long-run Model Dimension, D X W X H (mm)
| Galleon III 33/31/11 10K(L) Tower | 630 x 250 x 826 |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 630 x 250 x 826 |
Long-run Model Net Weight (kgs)
| Galleon III 33/31/11 10K(L) Tower | 25 |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | 37 |
MANAGEMENT
Optional SNMP
| Galleon III 33/31/11 10K(L) Tower | Power management from SNMP manager and web browser |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | Power management from SNMP manager and web browser |
Smart RS-232 / USB
| Galleon III 33/31/11 10K(L) Tower | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
|---|---|
| Galleon III 33/31/11 20K(L) Tower | Supports Windows® family, Linux and MAC |
| Brochure | Brochure | |
| Manual | Manual |
Three phase - Online UPS Galleon III 3P/3P & 3P/1P & 1P/1P Tower 10KL-20KL PF1 high-frequency Online UPS