Galleon II/III 10K-40K
PF1, three-level inverter, common battery
Galleon II/III 10K-40K provides better output power factor up to 1.0 with higher performance and efficiency for critical applications. It’s same as Galleon series with programmable power management outlets which can extend available battery time to critical devices by shutting down unnecessary devices. This Galleon II 3P/3P 10K-40K series is also suitable for laser printer and ultrasound system load.


Main Features
- True double-conversion
- DSP technology guarantees high performance
- Output power factor 1
- Active power factor correction in all phases
- 50Hz/60Hz frequency converter mode
- Dual AC inputs
- Emergency power off function (EPO)
- Generator compatible
- Adjustable battery numbers for long-run model
- Maintenance bypass available
- Parallel operation up to 4 units with common battery
- Optional isolation transformer offers full isolation and complete 40K(L), 30K(L) 20K(L), 10K(L) common mode noise rejection
MODEL | Galleon II-3/3 10K(L) | Galleon II-3/3 20K(L) | Galleon III-3/3 30K(L) | Galleon III-3/3 40K(L) | |
CAPACITY | 10 KVA / 10 KW | 20KVA/20KW | 30 KVA / 30 KW | 40 KVA / 40 KW | |
PHASE | 3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph out | 3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph out | 3-phase in/3-phase out | 3-phase in/3-phase out | |
PARALLEL CAPABILITY | up to 4 units in parallel | up to 4 units in parallel | up to 4 units in parallel | up to 4 units in parallel | |
INPUT | |||||
Voltage Range | 110-300 VAC ± 3 % @ 50% load ; 176-276 VAC ± 3 % @ 100% load | 110-300 VAC ± 3 % @ 50% load ; 176-276 VAC ± 3 % @ 100% load | 110-300 VAC ± 3 % @ 50% load ; 176-276 VAC ± 3 % @ 100% load | 110-300 VAC ± 3 % @ 50% load ; 176-276 VAC ± 3 % @ 100% load | |
Nominal Voltage | 3 x 400 VAC (3Ph+N) / 230 VAC (1Ph+N) | 3 x 400 VAC (3Ph+N) / 230 VAC (1Ph+N) | 3 x 360/380/400/415 VAC (3Ph+N) | 3 x 360/380/400/415 VAC (3Ph+N) | |
Frequency Range | 46~54 Hz or 56~64Hz | 46~54 Hz or 56~64Hz | 40~70 Hz | 40~70 Hz | |
Power Factor | ≧ 0.99 @ 100% load | ≧ 0.99 @ 100% load | ≧ 0.99 @ 100% load | ≧ 0.99 @ 100% load | |
OUTPUT | |||||
Output Voltage | 3 x 360/380/400/415 VAC(3Ph+N) or 208/220/230/240 VAC (1Ph+N) | 3 x 360/380/400/415 VAC(3Ph+N) or 208/220/230/240 VAC (1Ph+N) | 3 x 360*/380*/400/415 VAC (3Ph+N) | 3 x 360*/380*/400/415 VAC (3Ph+N) | |
AC Voltage Regulation (Batt. Mode) | ± 1% | ± 1% | ± 1% | ± 1% | |
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50/60 Hz ± 1% | 50/60 Hz ± 1% | |
Transfer Time | AC Mode to Battery Mode | zero | zero | zero | zero |
Transfer Time | Inverter to Bypass | zero | zero | zero | zero |
Waveform (Batt. Mode) | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | |
Current Crest Ratio | 3:1 (max.) | 3:1 (max.) | 3:1 (max.) | 3:1 (max.) | |
Harmonic Distortion | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) | |
Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz | |
Overload | AC Mode | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
Overload | Battery Mode | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
EFFICIENCY | |||||
Battery Mode | 95.5% | 95.5% | 95.5% | 95.5% | |
ECO Mode | 98.5% | 98.5% | 98.5% | 98.5% | |
AC Mode | 94.5% | 94.5% | 94.5% | 94.5% | |
BYPASS | |||||
Overload Capability | > 130% 1 minute (default) ; continuously working until breaker protection (optional) | > 130% 1 minute (default) ; continuously working until breaker protection (optional) | > 130% 1 minute (default) ; continuously working until breaker protection (optional) | > 130% 1 minute (default) ; continuously working until breaker protection (optional) | |
Nominal Voltage | 3 x 380/400/415 VAC (3Ph+N) | 3 x 380/400/415 VAC (3Ph+N) | 3 x 360/380/400/415 VAC (3Ph+N) | 3 x 360/380/400/415 VAC (3Ph+N) | |
Voltage Range | -30% ~ +20% (Adjustable) | -30% ~ +20% (Adjustable) | 305VAC~457VAC | 305VAC~457VAC | |
Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz | |
BATTERY | |||||
Long-run Model | Model-Battery Type | Depending on the capacity of external batteries | Depending on the capacity of external batteries | Depending on the capacity of external batteries | Depending on the capacity of external batteries |
Long-run Model | Model-Charging Current (max.) | 1A ~ 12A (Adjustable) | 1A ~ 12A (Adjustable) | 1A ~ 12A (Adjustable) | 1A ~ 12A (Adjustable) |
Long-run Model | Model-Charging Voltage | +/-13.65V*N (N=8~10) | +/-13.65V*N (N=16~20) | +/-13.65V*N (N = 16~20) | +/-13.65V*N (N = 16~20) |
Long-run Model | Model-Numbers | 20 pcs | 20 pcs | 32~40 pcs (Adjustable | 32~40 pcs (Adjustable |
Standard Model | Battery Type | 12V/9Ah | 12V/9Ah | 12V/7Ah | 12V/9Ah |
Standard Model | Charging Current (max.) | 1A (Default) | 1A (Default) | 2A (Default) | 2A (Default) |
Standard Model | Charging Voltage | +/-136.5 VDC ± 10% | +/-218 VDC ± 10% | +/- 13.65 V*N ; ± 1% (N = 16~20) | +/- 13.65 V*N ; ± 1% (N = 16~20) |
Standard Model | Numbers | (10+10)pcs | (16+16)pcs | (16+16)pcs x 2 strings | (16+16)pcs x 2 strings |
Standard Model | Typical Recharge Time | 9 hours recover to 90% capacity | 9 hours recover to 90% capacity | 9 hours recover to 90% capacity | 9 hours recover to 90% capacity |
INDICATORS | |||||
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | |
ENVIRONMENT | |||||
Operating Temperature | 0~40°C | 0~40°C | 0~40°C | 0~40°C | |
Operating Humidity | <95% and non-condersing | <95% and non-condersing | <95% and non-condersing | <95% and non-condersing | |
Noise Level | Less than 55dB @ 1 Meter | Less than 58dB @ 1 Meter | Less than 65dB @ 1 Meter | Less than 70dB @ 1 Meter | |
PHYSICAL | |||||
Standard Model | Dimension, D X W X H (mm) | 630 x 250 x 826 | 630 x 250 x 826 | 815 x 300 x 1000 | 815 x 300 x 1000 |
Standard Model | Net Weight (kgs) | 124 | 139 | 207 | 233 |
Long-run Model | Dimension, D X W X H (mm) | 630 x 250 x 826 | 630 x 250 x 826 | 815 x 300 x 1000 | 815 x 300 x 1000 |
Long-run Model | Net Weight (kgs) | 37 | 43 | 56 | 56 |
MANAGEMENT | |||||
Optional SNMP | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | |
Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
General
CAPACITY
Galleon II-3/3 10K(L) | 10 KVA / 10 KW |
---|---|
Galleon II-3/3 20K(L) | 20KVA/20KW |
Galleon III-3/3 30K(L) | 30 KVA / 30 KW |
Galleon III-3/3 40K(L) | 40 KVA / 40 KW |
PHASE
Galleon II-3/3 10K(L) | 3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph out |
---|---|
Galleon II-3/3 20K(L) | 3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph out |
Galleon III-3/3 30K(L) | 3-phase in/3-phase out |
Galleon III-3/3 40K(L) | 3-phase in/3-phase out |
PARALLEL CAPABILITY
Galleon II-3/3 10K(L) | up to 4 units in parallel |
---|---|
Galleon II-3/3 20K(L) | up to 4 units in parallel |
Galleon III-3/3 30K(L) | up to 4 units in parallel |
Galleon III-3/3 40K(L) | up to 4 units in parallel |
INPUT
Voltage Range
Galleon II-3/3 10K(L) | 110-300 VAC ± 3 % @ 50% load ; 176-276 VAC ± 3 % @ 100% load |
---|---|
Galleon II-3/3 20K(L) | 110-300 VAC ± 3 % @ 50% load ; 176-276 VAC ± 3 % @ 100% load |
Galleon III-3/3 30K(L) | 110-300 VAC ± 3 % @ 50% load ; 176-276 VAC ± 3 % @ 100% load |
Galleon III-3/3 40K(L) | 110-300 VAC ± 3 % @ 50% load ; 176-276 VAC ± 3 % @ 100% load |
Nominal Voltage
Galleon II-3/3 10K(L) | 3 x 400 VAC (3Ph+N) / 230 VAC (1Ph+N) |
---|---|
Galleon II-3/3 20K(L) | 3 x 400 VAC (3Ph+N) / 230 VAC (1Ph+N) |
Galleon III-3/3 30K(L) | 3 x 360/380/400/415 VAC (3Ph+N) |
Galleon III-3/3 40K(L) | 3 x 360/380/400/415 VAC (3Ph+N) |
Frequency Range
Galleon II-3/3 10K(L) | 46~54 Hz or 56~64Hz |
---|---|
Galleon II-3/3 20K(L) | 46~54 Hz or 56~64Hz |
Galleon III-3/3 30K(L) | 40~70 Hz |
Galleon III-3/3 40K(L) | 40~70 Hz |
Power Factor
Galleon II-3/3 10K(L) | ≧ 0.99 @ 100% load |
---|---|
Galleon II-3/3 20K(L) | ≧ 0.99 @ 100% load |
Galleon III-3/3 30K(L) | ≧ 0.99 @ 100% load |
Galleon III-3/3 40K(L) | ≧ 0.99 @ 100% load |
OUTPUT
Output Voltage
Galleon II-3/3 10K(L) | 3 x 360/380/400/415 VAC(3Ph+N) or 208/220/230/240 VAC (1Ph+N) |
---|---|
Galleon II-3/3 20K(L) | 3 x 360/380/400/415 VAC(3Ph+N) or 208/220/230/240 VAC (1Ph+N) |
Galleon III-3/3 30K(L) | 3 x 360*/380*/400/415 VAC (3Ph+N) |
Galleon III-3/3 40K(L) | 3 x 360*/380*/400/415 VAC (3Ph+N) |
AC Voltage Regulation (Batt. Mode)
Galleon II-3/3 10K(L) | ± 1% |
---|---|
Galleon II-3/3 20K(L) | ± 1% |
Galleon III-3/3 30K(L) | ± 1% |
Galleon III-3/3 40K(L) | ± 1% |
Frequency Range (Batt. Mode)
Galleon II-3/3 10K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
---|---|
Galleon II-3/3 20K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon III-3/3 30K(L) | 50/60 Hz ± 1% |
Galleon III-3/3 40K(L) | 50/60 Hz ± 1% |
Transfer Time AC Mode to Battery Mode
Galleon II-3/3 10K(L) | zero |
---|---|
Galleon II-3/3 20K(L) | zero |
Galleon III-3/3 30K(L) | zero |
Galleon III-3/3 40K(L) | zero |
Transfer Time Inverter to Bypass
Galleon II-3/3 10K(L) | zero |
---|---|
Galleon II-3/3 20K(L) | zero |
Galleon III-3/3 30K(L) | zero |
Galleon III-3/3 40K(L) | zero |
Waveform (Batt. Mode)
Galleon II-3/3 10K(L) | Pure Sine Wave |
---|---|
Galleon II-3/3 20K(L) | Pure Sine Wave |
Galleon III-3/3 30K(L) | Pure Sine Wave |
Galleon III-3/3 40K(L) | Pure Sine Wave |
Current Crest Ratio
Galleon II-3/3 10K(L) | 3:1 (max.) |
---|---|
Galleon II-3/3 20K(L) | 3:1 (max.) |
Galleon III-3/3 30K(L) | 3:1 (max.) |
Galleon III-3/3 40K(L) | 3:1 (max.) |
Harmonic Distortion
Galleon II-3/3 10K(L) | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) |
---|---|
Galleon II-3/3 20K(L) | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) |
Galleon III-3/3 30K(L) | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) |
Galleon III-3/3 40K(L) | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) |
Frequency Range (Synchronized Range)
Galleon II-3/3 10K(L) | 46~54Hz or 56~64Hz |
---|---|
Galleon II-3/3 20K(L) | 46~54Hz or 56~64Hz |
Galleon III-3/3 30K(L) | 46~54Hz or 56~64Hz |
Galleon III-3/3 40K(L) | 46~54Hz or 56~64Hz |
Overload AC Mode
Galleon II-3/3 10K(L) | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
---|---|
Galleon II-3/3 20K(L) | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
Galleon III-3/3 30K(L) | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
Galleon III-3/3 40K(L) | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
Overload Battery Mode
Galleon II-3/3 10K(L) | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
---|---|
Galleon II-3/3 20K(L) | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
Galleon III-3/3 30K(L) | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
Galleon III-3/3 40K(L) | 100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown |
EFFICIENCY
Battery Mode
Galleon II-3/3 10K(L) | 95.5% |
---|---|
Galleon II-3/3 20K(L) | 95.5% |
Galleon III-3/3 30K(L) | 95.5% |
Galleon III-3/3 40K(L) | 95.5% |
ECO Mode
Galleon II-3/3 10K(L) | 98.5% |
---|---|
Galleon II-3/3 20K(L) | 98.5% |
Galleon III-3/3 30K(L) | 98.5% |
Galleon III-3/3 40K(L) | 98.5% |
AC Mode
Galleon II-3/3 10K(L) | 94.5% |
---|---|
Galleon II-3/3 20K(L) | 94.5% |
Galleon III-3/3 30K(L) | 94.5% |
Galleon III-3/3 40K(L) | 94.5% |
BYPASS
Overload Capability
Galleon II-3/3 10K(L) | > 130% 1 minute (default) ; continuously working until breaker protection (optional) |
---|---|
Galleon II-3/3 20K(L) | > 130% 1 minute (default) ; continuously working until breaker protection (optional) |
Galleon III-3/3 30K(L) | > 130% 1 minute (default) ; continuously working until breaker protection (optional) |
Galleon III-3/3 40K(L) | > 130% 1 minute (default) ; continuously working until breaker protection (optional) |
Nominal Voltage
Galleon II-3/3 10K(L) | 3 x 380/400/415 VAC (3Ph+N) |
---|---|
Galleon II-3/3 20K(L) | 3 x 380/400/415 VAC (3Ph+N) |
Galleon III-3/3 30K(L) | 3 x 360/380/400/415 VAC (3Ph+N) |
Galleon III-3/3 40K(L) | 3 x 360/380/400/415 VAC (3Ph+N) |
Voltage Range
Galleon II-3/3 10K(L) | -30% ~ +20% (Adjustable) |
---|---|
Galleon II-3/3 20K(L) | -30% ~ +20% (Adjustable) |
Galleon III-3/3 30K(L) | 305VAC~457VAC |
Galleon III-3/3 40K(L) | 305VAC~457VAC |
Frequency Range (Synchronized Range)
Galleon II-3/3 10K(L) | 46~54Hz or 56~64Hz |
---|---|
Galleon II-3/3 20K(L) | 46~54Hz or 56~64Hz |
Galleon III-3/3 30K(L) | 46~54Hz or 56~64Hz |
Galleon III-3/3 40K(L) | 46~54Hz or 56~64Hz |
BATTERY
Long-run Model Model-Battery Type
Galleon II-3/3 10K(L) | Depending on the capacity of external batteries |
---|---|
Galleon II-3/3 20K(L) | Depending on the capacity of external batteries |
Galleon III-3/3 30K(L) | Depending on the capacity of external batteries |
Galleon III-3/3 40K(L) | Depending on the capacity of external batteries |
Long-run Model Model-Charging Current (max.)
Galleon II-3/3 10K(L) | 1A ~ 12A (Adjustable) |
---|---|
Galleon II-3/3 20K(L) | 1A ~ 12A (Adjustable) |
Galleon III-3/3 30K(L) | 1A ~ 12A (Adjustable) |
Galleon III-3/3 40K(L) | 1A ~ 12A (Adjustable) |
Long-run Model Model-Charging Voltage
Galleon II-3/3 10K(L) | +/-13.65V*N (N=8~10) |
---|---|
Galleon II-3/3 20K(L) | +/-13.65V*N (N=16~20) |
Galleon III-3/3 30K(L) | +/-13.65V*N (N = 16~20) |
Galleon III-3/3 40K(L) | +/-13.65V*N (N = 16~20) |
Long-run Model Model-Numbers
Galleon II-3/3 10K(L) | 20 pcs |
---|---|
Galleon II-3/3 20K(L) | 20 pcs |
Galleon III-3/3 30K(L) | 32~40 pcs (Adjustable |
Galleon III-3/3 40K(L) | 32~40 pcs (Adjustable |
Standard Model Battery Type
Galleon II-3/3 10K(L) | 12V/9Ah |
---|---|
Galleon II-3/3 20K(L) | 12V/9Ah |
Galleon III-3/3 30K(L) | 12V/7Ah |
Galleon III-3/3 40K(L) | 12V/9Ah |
Standard Model Charging Current (max.)
Galleon II-3/3 10K(L) | 1A (Default) |
---|---|
Galleon II-3/3 20K(L) | 1A (Default) |
Galleon III-3/3 30K(L) | 2A (Default) |
Galleon III-3/3 40K(L) | 2A (Default) |
Standard Model Charging Voltage
Galleon II-3/3 10K(L) | +/-136.5 VDC ± 10% |
---|---|
Galleon II-3/3 20K(L) | +/-218 VDC ± 10% |
Galleon III-3/3 30K(L) | +/- 13.65 V*N ; ± 1% (N = 16~20) |
Galleon III-3/3 40K(L) | +/- 13.65 V*N ; ± 1% (N = 16~20) |
Standard Model Numbers
Galleon II-3/3 10K(L) | (10+10)pcs |
---|---|
Galleon II-3/3 20K(L) | (16+16)pcs |
Galleon III-3/3 30K(L) | (16+16)pcs x 2 strings |
Galleon III-3/3 40K(L) | (16+16)pcs x 2 strings |
Standard Model Typical Recharge Time
Galleon II-3/3 10K(L) | 9 hours recover to 90% capacity |
---|---|
Galleon II-3/3 20K(L) | 9 hours recover to 90% capacity |
Galleon III-3/3 30K(L) | 9 hours recover to 90% capacity |
Galleon III-3/3 40K(L) | 9 hours recover to 90% capacity |
INDICATORS
LCD Panel
Galleon II-3/3 10K(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
---|---|
Galleon II-3/3 20K(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon III-3/3 30K(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon III-3/3 40K(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
ENVIRONMENT
Operating Temperature
Galleon II-3/3 10K(L) | 0~40°C |
---|---|
Galleon II-3/3 20K(L) | 0~40°C |
Galleon III-3/3 30K(L) | 0~40°C |
Galleon III-3/3 40K(L) | 0~40°C |
Operating Humidity
Galleon II-3/3 10K(L) | <95% and non-condersing |
---|---|
Galleon II-3/3 20K(L) | <95% and non-condersing |
Galleon III-3/3 30K(L) | <95% and non-condersing |
Galleon III-3/3 40K(L) | <95% and non-condersing |
Noise Level
Galleon II-3/3 10K(L) | Less than 55dB @ 1 Meter |
---|---|
Galleon II-3/3 20K(L) | Less than 58dB @ 1 Meter |
Galleon III-3/3 30K(L) | Less than 65dB @ 1 Meter |
Galleon III-3/3 40K(L) | Less than 70dB @ 1 Meter |
PHYSICAL
Standard Model Dimension, D X W X H (mm)
Galleon II-3/3 10K(L) | 630 x 250 x 826 |
---|---|
Galleon II-3/3 20K(L) | 630 x 250 x 826 |
Galleon III-3/3 30K(L) | 815 x 300 x 1000 |
Galleon III-3/3 40K(L) | 815 x 300 x 1000 |
Standard Model Net Weight (kgs)
Galleon II-3/3 10K(L) | 124 |
---|---|
Galleon II-3/3 20K(L) | 139 |
Galleon III-3/3 30K(L) | 207 |
Galleon III-3/3 40K(L) | 233 |
Long-run Model Dimension, D X W X H (mm)
Galleon II-3/3 10K(L) | 630 x 250 x 826 |
---|---|
Galleon II-3/3 20K(L) | 630 x 250 x 826 |
Galleon III-3/3 30K(L) | 815 x 300 x 1000 |
Galleon III-3/3 40K(L) | 815 x 300 x 1000 |
Long-run Model Net Weight (kgs)
Galleon II-3/3 10K(L) | 37 |
---|---|
Galleon II-3/3 20K(L) | 43 |
Galleon III-3/3 30K(L) | 56 |
Galleon III-3/3 40K(L) | 56 |
MANAGEMENT
Optional SNMP
Galleon II-3/3 10K(L) | Power management from SNMP manager and web browser |
---|---|
Galleon II-3/3 20K(L) | Power management from SNMP manager and web browser |
Galleon III-3/3 30K(L) | Power management from SNMP manager and web browser |
Galleon III-3/3 40K(L) | Power management from SNMP manager and web browser |
Smart RS-232 / USB
Galleon II-3/3 10K(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
---|---|
Galleon II-3/3 20K(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon III-3/3 30K(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon III-3/3 40K(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
![]() |
Brochure | Galleon_II-III-33-10K-40K |
![]() |
Manual | Galleon_II-III-33-10K-40K |
Three phase - Online UPS Galleon II/III 10K-40K PF1, three-level inverter, common battery