Galleon II 3P/3P RT 10K-60K
PF 1.0 high frequency UPS
Galleon II 33 Rack/Tower 10K-60K is a high-frequency UPS with a superior output power factor at 1.0 offering high performance and efficiency for critical application. It provides an affordable solution for your mission-critical load and can be paralleled up to three units. Its adjustable current charger (Max. to 18A) makes your power deployment more flexible.
Main Features
  • True double-conversion
  • LCD screen auto-rotation with Rack position (only for 10K-40K models)
  • DSP technology guarantees high performance
  • Output power factor 1
  • Active power factor correction in all phases
  • 50Hz/60Hz frequency converter mode
  • ECO mode operation for energy saving (ECO)
  • Emergency power off function (EPO)
  • Generator compatible
  • Supports dual AC inputs
  • Adjustable battery numbers
  • Parallel operation with commom battery
General
CAPACITY
Galleon II 3P/3P Rack Tower 10K (L)10KVA /10KW
Galleon II 3P/3P Rack Tower 15K (L)15KVA /15KW
Galleon II 3P/3P Rack Tower 20K (L)20KVA /20KW
Galleon II 3P/3P Rack Tower 30K (L)30KVA/30KW
Galleon II 3P/3P Rack Tower 40K (L)40KVA/40KW
Galleon II 3P/3P Rack Tower 60K (L)60KVA/60KW
PHASE
Galleon II 3P/3P Rack Tower 10K (L)3-phase in / 3-phase out
Galleon II 3P/3P Rack Tower 15K (L)3-phase in / 3-phase out
Galleon II 3P/3P Rack Tower 20K (L)3-phase in / 3-phase out
Galleon II 3P/3P Rack Tower 30K (L)3-phase in / 3-phase out
Galleon II 3P/3P Rack Tower 40K (L)3-phase in / 3-phase out
Galleon II 3P/3P Rack Tower 60K (L)3-phase in / 3-phase out
Parallel Capability
Galleon II 3P/3P Rack Tower 10K (L)4
Galleon II 3P/3P Rack Tower 15K (L)4
Galleon II 3P/3P Rack Tower 20K (L)4
Galleon II 3P/3P Rack Tower 30K (L)4
Galleon II 3P/3P Rack Tower 40K (L)4
Galleon II 3P/3P Rack Tower 60K (L)4
INPUT
Voltage Range
Galleon II 3P/3P Rack Tower 10K (L)190-520 VAC (3-phase) @50% load ; 305-478 VAC (3-phase)@ 100% load
Galleon II 3P/3P Rack Tower 15K (L)190-520 VAC (3-phase) @50% load ; 305-478 VAC (3-phase)@ 100% load
Galleon II 3P/3P Rack Tower 20K (L)190-520 VAC (3-phase) @50% load ; 305-478 VAC (3-phase)@ 100% load
Galleon II 3P/3P Rack Tower 30K (L)190-520 VAC (3-phase) @50% load ; 305-478 VAC (3-phase)@ 100% load
Galleon II 3P/3P Rack Tower 40K (L)190-520 VAC (3-phase) @50% load ; 305-478 VAC (3-phase)@ 100% load
Galleon II 3P/3P Rack Tower 60K (L)190-520 VAC (3-phase) @50% load ; 305-478 VAC (3-phase)@ 100% load
Nominal Voltage
Galleon II 3P/3P Rack Tower 10K (L)3 x 400 VAC (3Ph+N) or 208*/220/230/240 VAC (Ph-N)
Galleon II 3P/3P Rack Tower 15K (L)3 x 400 VAC (3Ph+N) or 208*/220/230/240 VAC (Ph-N)
Galleon II 3P/3P Rack Tower 20K (L)3 x 400 VAC (3Ph+N) or 208*/220/230/240 VAC (Ph-N)
Galleon II 3P/3P Rack Tower 30K (L)3 x 400 VAC (3Ph+N) or 208*/220/230/240 VAC (Ph-N)
Galleon II 3P/3P Rack Tower 40K (L)3 x 400 VAC (3Ph+N) or 208*/220/230/240 VAC (Ph-N)
Galleon II 3P/3P Rack Tower 60K (L)3 x 400 VAC (3Ph+N) or 208*/220/230/240 VAC (Ph-N)
Frequency Range
Galleon II 3P/3P Rack Tower 10K (L)46 Hz~54 Hz or 56~64Hz
Galleon II 3P/3P Rack Tower 15K (L)46 Hz~54 Hz or 56~64Hz
Galleon II 3P/3P Rack Tower 20K (L)46 Hz~54 Hz or 56~64Hz
Galleon II 3P/3P Rack Tower 30K (L)46 Hz~54 Hz or 56~64Hz
Galleon II 3P/3P Rack Tower 40K (L)46 Hz~54 Hz or 56~64Hz
Galleon II 3P/3P Rack Tower 60K (L)46 Hz~54 Hz or 56~64Hz
Power Factor
Galleon II 3P/3P Rack Tower 10K (L)≧ 0.99 @ 100% load
Galleon II 3P/3P Rack Tower 15K (L)≧ 0.99 @ 100% load
Galleon II 3P/3P Rack Tower 20K (L)≧ 0.99 @ 100% load
Galleon II 3P/3P Rack Tower 30K (L)≧ 0.99 @ 100% load
Galleon II 3P/3P Rack Tower 40K (L)≧ 0.99 @ 100% load
Galleon II 3P/3P Rack Tower 60K (L)≧ 0.99 @ 100% load
OUTPUT
Output Voltage
Galleon II 3P/3P Rack Tower 10K (L)3 x 360*/380/400/415 VAC (3Ph+N) or 208*/220/230/240 VAC (Ph-N)
Galleon II 3P/3P Rack Tower 15K (L)3 x 360*/380/400/415 VAC (3Ph+N) or 208*/220/230/240 VAC (Ph-N)
Galleon II 3P/3P Rack Tower 20K (L)3 x 360*/380/400/415 VAC (3Ph+N) or 208*/220/230/240 VAC (Ph-N)
Galleon II 3P/3P Rack Tower 30K (L)3 x 360*/380/400/415 VAC (3Ph+N) or 208*/220/230/240 VAC (Ph-N)
Galleon II 3P/3P Rack Tower 40K (L)3 x 360*/380/400/415 VAC (3Ph+N)
Galleon II 3P/3P Rack Tower 60K (L)3 x 360*/380/400/415 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode)
Galleon II 3P/3P Rack Tower 10K (L)± 1%
Galleon II 3P/3P Rack Tower 15K (L)± 1%
Galleon II 3P/3P Rack Tower 20K (L)± 1%
Galleon II 3P/3P Rack Tower 30K (L)± 1%
Galleon II 3P/3P Rack Tower 40K (L)± 1%
Galleon II 3P/3P Rack Tower 60K (L)± 1%
Frequency Range (Batt. Mode)
Galleon II 3P/3P Rack Tower 10K (L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon II 3P/3P Rack Tower 15K (L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon II 3P/3P Rack Tower 20K (L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon II 3P/3P Rack Tower 30K (L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon II 3P/3P Rack Tower 40K (L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Galleon II 3P/3P Rack Tower 60K (L)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Transfer Time AC Mode to Battery Mode
Galleon II 3P/3P Rack Tower 10K (L)Zero
Galleon II 3P/3P Rack Tower 15K (L)Zero
Galleon II 3P/3P Rack Tower 20K (L)Zero
Galleon II 3P/3P Rack Tower 30K (L)Zero
Galleon II 3P/3P Rack Tower 40K (L)Zero
Galleon II 3P/3P Rack Tower 60K (L)Zero
Transfer Time Inverter to Bypass
Galleon II 3P/3P Rack Tower 10K (L)Zero
Galleon II 3P/3P Rack Tower 15K (L)Zero
Galleon II 3P/3P Rack Tower 20K (L)Zero
Galleon II 3P/3P Rack Tower 30K (L)Zero
Galleon II 3P/3P Rack Tower 40K (L)Zero
Galleon II 3P/3P Rack Tower 60K (L)Zero
Waveform (Batt. Mode)
Galleon II 3P/3P Rack Tower 10K (L)Pure Sine Wave
Galleon II 3P/3P Rack Tower 15K (L)Pure Sine Wave
Galleon II 3P/3P Rack Tower 20K (L)Pure Sine Wave
Galleon II 3P/3P Rack Tower 30K (L)Pure Sine Wave
Galleon II 3P/3P Rack Tower 40K (L)Pure Sine Wave
Galleon II 3P/3P Rack Tower 60K (L)Pure Sine Wave
Current Crest Ratio
Galleon II 3P/3P Rack Tower 10K (L)3:1 (max.)
Galleon II 3P/3P Rack Tower 15K (L)3:1 (max.)
Galleon II 3P/3P Rack Tower 20K (L)3:1 (max.)
Galleon II 3P/3P Rack Tower 30K (L)3:1 (max.)
Galleon II 3P/3P Rack Tower 40K (L)3:1 (max.)
Galleon II 3P/3P Rack Tower 60K (L)3:1 (max.)
Harmonic Distortion
Galleon II 3P/3P Rack Tower 10K (L)≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load)
Galleon II 3P/3P Rack Tower 15K (L)≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load)
Galleon II 3P/3P Rack Tower 20K (L)≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load)
Galleon II 3P/3P Rack Tower 30K (L)≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load)
Galleon II 3P/3P Rack Tower 40K (L)≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load)
Galleon II 3P/3P Rack Tower 60K (L)≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load)
Frequency Range (Synchronized Range)
Galleon II 3P/3P Rack Tower 10K (L)46~54 Hz or 56~64 Hz
Galleon II 3P/3P Rack Tower 15K (L)46~54 Hz or 56~64 Hz
Galleon II 3P/3P Rack Tower 20K (L)46~54 Hz or 56~64 Hz
Galleon II 3P/3P Rack Tower 30K (L)46~54 Hz or 56~64 Hz
Galleon II 3P/3P Rack Tower 40K (L)46~54 Hz or 56~64 Hz
Galleon II 3P/3P Rack Tower 60K (L)46~54 Hz or 56~64 Hz
Overload AC Mode
Galleon II 3P/3P Rack Tower 10K (L)100- 110% for 60 min, 110- 125% for 10 min, 125%~150% for 1 min; >150% immediately
Galleon II 3P/3P Rack Tower 15K (L)100- 110% for 60 min, 110- 125% for 10 min, 125%~150% for 1 min; >150% immediately
Galleon II 3P/3P Rack Tower 20K (L)100- 110% for 60 min, 110- 125% for 10 min, 125%~150% for 1 min; >150% immediately
Galleon II 3P/3P Rack Tower 30K (L)100- 110% for 60 min, 110- 125% for 10 min, 125%~150% for 1 min; >150% immediately
Galleon II 3P/3P Rack Tower 40K (L)100- 110% for 60 min, 110- 125% for 10 min, 125%~150% for 1 min; >150% immediately
Galleon II 3P/3P Rack Tower 60K (L)100- 110% for 60 min, 110- 125% for 10 min, 125%~150% for 1 min; >150% immediately
Overload Battery Mode
Galleon II 3P/3P Rack Tower 10K (L)100- 110% for 60 min, 110- 125% for 10 min, 125%~150% for 1 min; >150% immediately
Galleon II 3P/3P Rack Tower 15K (L)100- 110% for 60 min, 110- 125% for 10 min, 125%~150% for 1 min; >150% immediately
Galleon II 3P/3P Rack Tower 20K (L)100- 110% for 60 min, 110- 125% for 10 min, 125%~150% for 1 min; >150% immediately
Galleon II 3P/3P Rack Tower 30K (L)100- 110% for 60 min, 110- 125% for 10 min, 125%~150% for 1 min; >150% immediately
Galleon II 3P/3P Rack Tower 40K (L)100- 110% for 60 min, 110- 125% for 10 min, 125%~150% for 1 min; >150% immediately
Galleon II 3P/3P Rack Tower 60K (L)100- 110% for 60 min, 110- 125% for 10 min, 125%~150% for 1 min; >150% immediately
EFFICIENCY
Battery Mode
Galleon II 3P/3P Rack Tower 10K (L)94.5%
Galleon II 3P/3P Rack Tower 15K (L)94.5%
Galleon II 3P/3P Rack Tower 20K (L)94.5%
Galleon II 3P/3P Rack Tower 30K (L)94.5%
Galleon II 3P/3P Rack Tower 40K (L)94.5%
Galleon II 3P/3P Rack Tower 60K (L)94.5%
ECO Mode
Galleon II 3P/3P Rack Tower 10K (L)98.5%
Galleon II 3P/3P Rack Tower 15K (L)98.5%
Galleon II 3P/3P Rack Tower 20K (L)98.5%
Galleon II 3P/3P Rack Tower 30K (L)98.5%
Galleon II 3P/3P Rack Tower 40K (L)98.5%
Galleon II 3P/3P Rack Tower 60K (L)98.5%
AC Mode
Galleon II 3P/3P Rack Tower 10K (L)95.5
Galleon II 3P/3P Rack Tower 15K (L)95.5
Galleon II 3P/3P Rack Tower 20K (L)95.5
Galleon II 3P/3P Rack Tower 30K (L)95.5
Galleon II 3P/3P Rack Tower 40K (L)95.5
Galleon II 3P/3P Rack Tower 60K (L)95.5
BATTERY
Battery Type
Galleon II 3P/3P Rack Tower 10K (L)Depending on the applications
Galleon II 3P/3P Rack Tower 15K (L)Depending on the applications
Galleon II 3P/3P Rack Tower 20K (L)Depending on the applications
Galleon II 3P/3P Rack Tower 30K (L)Depending on the applications
Galleon II 3P/3P Rack Tower 40K (L)Depending on the applications
Galleon II 3P/3P Rack Tower 60K (L)Depending on the applications
Charging Voltage
Galleon II 3P/3P Rack Tower 10K (L) +/-13.65VDC ± 10
Galleon II 3P/3P Rack Tower 15K (L) +/-13.65V*N (N=16~20)
Galleon II 3P/3P Rack Tower 20K (L) +/-13.65V*N (N=16~20)
Galleon II 3P/3P Rack Tower 30K (L) +/-13.65V*N (N=16~20)
Galleon II 3P/3P Rack Tower 40K (L) +/-13.65V*N (N=16~20)
Galleon II 3P/3P Rack Tower 60K (L) +/-13.65V*N (N=16~20)
Charging Current (max.)
Galleon II 3P/3P Rack Tower 10K (L)1A~12A (Adjustable)
Galleon II 3P/3P Rack Tower 15K (L)1A~12A (Adjustable)
Galleon II 3P/3P Rack Tower 20K (L)1A~12A (Adjustable)
Galleon II 3P/3P Rack Tower 30K (L)1A~12A (Adjustable)
Galleon II 3P/3P Rack Tower 40K (L)1A ~ 16A (Adjustable)
Galleon II 3P/3P Rack Tower 60K (L)1A ~ 18A (Adjustable)
Battery Numers
Galleon II 3P/3P Rack Tower 10K (L)20 pcs (Adjustable)
Galleon II 3P/3P Rack Tower 15K (L)32-40 pcs (Adjustable)
Galleon II 3P/3P Rack Tower 20K (L)32-40 pcs (Adjustable)
Galleon II 3P/3P Rack Tower 30K (L)32-40 pcs (Adjustable)
Galleon II 3P/3P Rack Tower 40K (L)32-40 pcs (Adjustable)
Galleon II 3P/3P Rack Tower 60K (L)32-40 pcs (Adjustable)
ENVIRONMENT
Operating Temperature
Galleon II 3P/3P Rack Tower 10K (L)0- 40°C
Galleon II 3P/3P Rack Tower 15K (L)0- 40°C
Galleon II 3P/3P Rack Tower 20K (L)0- 40°C
Galleon II 3P/3P Rack Tower 30K (L)0- 40°C
Galleon II 3P/3P Rack Tower 40K (L)0- 40°C
Galleon II 3P/3P Rack Tower 60K (L)0- 40°C
Operating Humidity
Galleon II 3P/3P Rack Tower 10K (L) < 95% and non-condensing
Galleon II 3P/3P Rack Tower 15K (L) < 95% and non-condensing
Galleon II 3P/3P Rack Tower 20K (L) < 95% and non-condensing
Galleon II 3P/3P Rack Tower 30K (L) < 95% and non-condensing
Galleon II 3P/3P Rack Tower 40K (L) < 95% and non-condensing
Galleon II 3P/3P Rack Tower 60K (L) < 95% and non-condensing
Noise Level
Galleon II 3P/3P Rack Tower 10K (L)Less than 62dB @ 1 Meter
Galleon II 3P/3P Rack Tower 15K (L)Less than 65dB @ 1 Meter
Galleon II 3P/3P Rack Tower 20K (L)Less than 65dB @ 1 Meter
Galleon II 3P/3P Rack Tower 30K (L)Less than 65dB @ 1 Meter
Galleon II 3P/3P Rack Tower 40K (L)Less than 70dB @ 1 Meter
Galleon II 3P/3P Rack Tower 60K (L)Less than 70dB @ 1 Meter
PHYSICAL
Dimension, D X W X H (mm)
Galleon II 3P/3P Rack Tower 10K (L)680 X 438 X 133 (3U)
Galleon II 3P/3P Rack Tower 15K (L)680 X 438 X 133 (3U)
Galleon II 3P/3P Rack Tower 20K (L)680 X 438 X 133 (3U)
Galleon II 3P/3P Rack Tower 30K (L)680 X 438 X 133 (3U)
Galleon II 3P/3P Rack Tower 40K (L)797 X 438 X 176 (4U)
Galleon II 3P/3P Rack Tower 60K (L)797 X 438 X 176 (4U)
Net Weight (kgs)
Galleon II 3P/3P Rack Tower 10K (L)27
Galleon II 3P/3P Rack Tower 15K (L)30
Galleon II 3P/3P Rack Tower 20K (L)30
Galleon II 3P/3P Rack Tower 30K (L)32
Galleon II 3P/3P Rack Tower 40K (L)34
Galleon II 3P/3P Rack Tower 60K (L)45
MANAGEMENT
Optional SNMP
Galleon II 3P/3P Rack Tower 10K (L)Power management from SNMP manager and web browser
Galleon II 3P/3P Rack Tower 15K (L)Power management from SNMP manager and web browser
Galleon II 3P/3P Rack Tower 20K (L)Power management from SNMP manager and web browser
Galleon II 3P/3P Rack Tower 30K (L)Power management from SNMP manager and web browser
Galleon II 3P/3P Rack Tower 40K (L)Power management from SNMP manager and web browser
Galleon II 3P/3P Rack Tower 60K (L)Power management from SNMP manager and web browser
Smart RS-232 / USB
Galleon II 3P/3P Rack Tower 10K (L)Supports Windows® family, Linux and MAC
Galleon II 3P/3P Rack Tower 15K (L)Supports Windows® family, Linux and MAC
Galleon II 3P/3P Rack Tower 20K (L)Supports Windows® family, Linux and MAC
Galleon II 3P/3P Rack Tower 30K (L)Supports Windows® family, Linux and MAC
Galleon II 3P/3P Rack Tower 40K (L)Supports Windows® family, Linux and MAC
Galleon II 3P/3P Rack Tower 60K (L)Supports Windows® family, Linux and MAC
Brochure Galleon_II-33-10K-60K-Rack
Manual Galleon_II-33-10K-60K-Rack
Related Products