EVA 5460S-EVA 5490S-EVA 54120S-EVA 54180S
IP54, 60kw-180kw DC EV charger
EV charger series occupied with Voltronic’s fully self-developed CCS controller and OCPP to ensure product stability and avoid maintenance risks. Patent ECO Energy Saving Mode to reduce energy consumption. Once vehicle charging is complete, the charging station will go into sleep mode (consumption 12W) even with the nozzle connected. The charging station will resume charging if the nozzle is connected to another vehicle. Moreover, the patent modularized the design of the charging module will facilitate replacement and lower maintenance costs.
Main Features
  • Patent ECO energy saving mode: Once vehicle charging is complete, the charging station will go into sleep mode (consumption 12W ) even with nozzle connected. The charging station will resume charging if the nozzle is connected to another vehicle
  • Patent full-modularized design including control system, power source system, distributed power system, power factor system
  • In-house developed controllers, CCS and OCPP charging modules
  • Supports multiple charging standards: GB, CCS1, CCS2 and CHAdeMO
  • The charger had successfully passed 33 sets of rigorous environmental and thermal shock tests from -35°C to 55°to ensure the system reliability
  • The DC power module is equipped with UL approved epoxy resin automatic injection to sustain the dusty and salty air tests to improve environmental adaptability
  • IP54 protection, IK10 for cabinet and IK08 for touch screen
  • Each charging mode with dedicated LED status indicator light (easy and intuitive charging experience)
  • Multilingual support for 7 colored touch LCD
  • Maximum efficiency up to 95%
  • Input power factor 0.99
  • THDi 5% at full load
  • Built-in RFID card reader
  • Supports OCPP 1.6 JSON network and 3G/4G
  • Adapting OCPP network security protocol to implement the OTA feature
  • The charger had successfully passed cloud network protocol test and was verified by OCTT
  • The charger had passed vehicle end protocol DIN 70121, ISO15118, and was verified by TUV
  • The Linux 5.10 OS and CPU conformed with cybersecurity standards
  • Third-party certified CE EN61851
General
Charging Type
EVA 5460SDC fast charging
EVA 5490SDC fast charging
EVA 54120SDC fast charging
EVA 54180SDC fast charging
Connector Type
EVA 5460S3P + N + PE
EVA 5490S3P + N + PE
EVA 54120S3P + N + PE
EVA 54180S3P + N + PE
Outlet Options
EVA 5460SC: CCS2 cable, A: CCS1 cable, J:CHAdeMO cable, G: GBT cable
EVA 5490SC: CCS2 cable, A: CCS1 cable, J:CHAdeMO cable, G: GBT cable
EVA 54120SC: CCS2 cable, A: CCS1 cable, J:CHAdeMO cable, G: GBT cable
EVA 54180SC: CCS2 cable, A: CCS1 cable, J:CHAdeMO cable, G: GBT cable
Overvoltage Category
EVA 5460SType II
EVA 5490SType II
EVA 54120SType II
EVA 54180SType II
AC Input/output Power Rating
EVA 5460S93 A, 64 kVA @ 400V 50 Hz
EVA 5490S139 A, 96 kVA @ 400V 50 Hz
EVA 54120S185 A, 128 kVA @ 400V 50Hz
EVA 54180S278 A, 192 kVA @ 400V 50Hz
Cellular Communication
EVA 5460SGSM, 4G, LTE
EVA 5490SGSM, 4G, LTE
EVA 54120SGSM, 4G, LTE
EVA 54180SGSM, 4G, LTE
Input/ouput voltage
EVA 5460S400 VAC or 380 VAC ± 10%
EVA 5490S400 VAC or 380 VAC ± 10%
EVA 54120S400 VAC or 380 VAC ± 10%
EVA 54180S400 VAC or 380 VAC ± 10%
Input Frequency
EVA 5460S50 Hz or 60 Hz
EVA 5490S50 Hz or 60 Hz
EVA 54120S50 Hz or 60 Hz
EVA 54180S50 Hz or 60 Hz
Number of EV Served
EVA 5460SUp to 2 (CC, AA, JC, JJ ,GG models) Up to 1 (C, A, G models)
EVA 5490SUp to 2 (CC, AA, JC, JJ ,GG models) Up to 1 (C, A, G models)
EVA 54120SUp to 2 (CC, AA, JC, JJ ,GG models) Up to 1 (C, A, G models)
EVA 54180SUp to 2 (CC, AA, JC, JJ ,GG models) Up to 1 (C, A, G models)
Cable Length
EVA 5460S5 m default, optional 6.0 m/ 7.0 m
EVA 5490S5 m default, optional 6.0 m/ 7.0 m
EVA 54120S5 m default, optional 6.0 m/ 7.0 m
EVA 54180S5 m default, optional 6.0 m/ 7.0 m
Maximum Current CCS Cables
EVA 5460S150 A
EVA 5490S150 A, Optional: 200A
EVA 54120S200 A
EVA 54180S200 A, Optional: 300 A
Maximum Current CHAdeMO Cables
EVA 5460S125 A
EVA 5490S125 A
EVA 54120S125 A, Optional: 200 A
EVA 54180S125 A, Optional: 200 A
Maximum Current GBT Cables
EVA 5460S150 A
EVA 5490S150 A
EVA 54120S250 A
EVA 54180S250 A
Electro-Magnetic Compatibility
EVA 5460SClass A (optional Class B) according to EN 61000-6-3:2007
EVA 5490SClass A (optional Class B) according to EN 61000-6-3:2007
EVA 54120SClass A (optional Class B) according to EN 61000-6-3:2007
EVA 54180SClass A (optional Class B) according to EN 61000-6-3:2007
Distribution Systems
EVA 5460STN-S. TN-C, TN-C-S, TT (required external RCD)
EVA 5490STN-S. TN-C, TN-C-S, TT (required external RCD)
EVA 54120STN-S. TN-C, TN-C-S, TT (required external RCD)
EVA 54180STN-S. TN-C, TN-C-S, TT (required external RCD)
Protection
EVA 5460SOvercurrent, overvoltage, undervoltage, integrated surge protection, grounding fault including DC leakage protection, door opening protection
EVA 5490SOvercurrent, overvoltage, undervoltage, integrated surge protection, grounding fault including DC leakage protection, door opening protection
EVA 54120SOvercurrent, overvoltage, undervoltage, integrated surge protection, grounding fault including DC leakage protection, door opening protection
EVA 54180SOvercurrent, overvoltage, undervoltage, integrated surge protection, grounding fault including DC leakage protection, door opening protection
Energy Metering
EVA 5460SStandard: Meter for DC outlet, Optional: AC inlet
EVA 5490SStandard: Meter for DC outlet, Optional: AC inlet
EVA 54120SStandard: Meter for DC outlet, Optional: AC inlet
EVA 54180SStandard: Meter for DC outlet, Optional: AC inlet
DC Output Power Rating(MAX)
EVA 5460S60 kW
EVA 5490S90 kW
EVA 54120S120 kW
EVA 54180S180 kW
Power Factor (Full Load)
EVA 5460S≥ 0.99
EVA 5490S≥ 0.99
EVA 54120S≥ 0.99
EVA 54180S≥ 0.99
THDi
EVA 5460S≤ 5%
EVA 5490S≤ 5%
EVA 54120S≤ 5%
EVA 54180S≤ 5%
Efficiency
EVA 5460S94% (peak)
EVA 5490S94% (peak)
EVA 54120S94% (peak)
EVA 54180S95% (peak)
Standby Power
EVA 5460S< 35 W
EVA 5490S< 35 W
EVA 54120S< 35 W
EVA 54180S< 35 W
Short Circuit Current
EVA 5460S10 kA
EVA 5490S10 kA
EVA 54120S10 kA
EVA 54180S10 kA
Pre-charge Current
EVA 5460S< 1 A
EVA 5490S< 1 A
EVA 54120S< 1 A
EVA 54180S< 1 A
Inrush Current
EVA 5460S< 100 A
EVA 5490S< 100 A
EVA 54120S< 100 A
EVA 54180S< 100 A
Leakage Current
EVA 5460S0.8 mA
EVA 5490S0.8 mA
EVA 54120S0.8 mA
EVA 54180S0.8 mA
USER INTERFACE
RFID Reader
EVA 5460SISO/IEC 14443 A/B Mifare RFID reader
EVA 5490SISO/IEC 14443 A/B Mifare RFID reader
EVA 54120SISO/IEC 14443 A/B Mifare RFID reader
EVA 54180SISO/IEC 14443 A/B Mifare RFID reader
User Authentication
EVA 5460SRFID, QR code
EVA 5490SRFID, QR code
EVA 54120SRFID, QR code
EVA 54180SRFID, QR code
Emergency Button
EVA 5460SYes
EVA 5490SYes
EVA 54120SYes
EVA 54180SYes
Connectivity
EVA 5460SInternet access via 4G/3G/Ethernet (RJ45)
EVA 5490SInternet access via 4G/3G/Ethernet (RJ45)
EVA 54120SInternet access via 4G/3G/Ethernet (RJ45)
EVA 54180SInternet access via 4G/3G/Ethernet (RJ45)
User Interface
EVA 5460S7" LCD high-contrast touchscreen
EVA 5490S7" LCD high-contrast touchscreen
EVA 54120S7" LCD high-contrast touchscreen
EVA 54180S7" LCD high-contrast touchscreen
Communiation Protocols
EVA 5460SProprietary and OCPP 1.6J
EVA 5490SProprietary and OCPP 1.6J
EVA 54120SProprietary and OCPP 1.6J
EVA 54180SProprietary and OCPP 1.6J
GENERAL CHARACTERISTICS
Mounting
EVA 5460SFree-standing cabinet
EVA 5490SFree-standing cabinet
EVA 54120SFree-standing cabinet
EVA 54180SFree-standing cabinet
Operating Altitude
EVA 5460SUp to 2000m
EVA 5490SUp to 2000m
EVA 54120SUp to 2000m
EVA 54180SUp to 2000m
Humidity
EVA 5460S< 95%, non-condensing
EVA 5490S< 95%, non-condensing
EVA 54120S< 95%, non-condensing
EVA 54180S< 95%, non-condensing
Protection Rating
EVA 5460SIP54 and IK10 (cabinet) / IK8 (touchscreen)
EVA 5490SIP54 and IK10 (cabinet) / IK8 (touchscreen)
EVA 54120SIP54 and IK10 (cabinet) / IK8 (touchscreen)
EVA 54180SIP54 and IK10 (cabinet) / IK8 (touchscreen)
Operating Temperature
EVA 5460S-35 °C to 55 °C
EVA 5490S-35 °C to 55 °C
EVA 54120S-35 °C to 55 °C
EVA 54180S-35 °C to 55 °C
Net Weight (kgs)
EVA 5460S295
EVA 5490S335
EVA 54120S355
EVA 54180S395
Housing Material
EVA 5460SSGCC, Optional: SUS430
EVA 5490SSGCC, Optional: SUS430
EVA 54120SSGCC, Optional: SUS430
EVA 54180SSGCC, Optional: SUS430
Storage Temperature
EVA 5460S-40 °C to 70 °C
EVA 5490S-40 °C to 70 °C
EVA 54120S-40 °C to 70 °C
EVA 54180S-40 °C to 70 °C
Dimensions (D x W x H) mm
EVA 5460S750 x 740 x 1830
EVA 5490S750 x 740 x 1830
EVA 54120S750 x 740 x 1830
EVA 54180S750 x 740 x 1830
COMPLIANCE STANDARDS
Safety Standards
EVA 5460SDIN 70121, ISO/IEC 15118 ed 1, CHAdeMO 1.2, GBT27930, GBT 34657
EVA 5490SDIN 70121, ISO/IEC 15118 ed 1, CHAdeMO 1.2, GBT27930, GBT 34657
EVA 54120SDIN 70121, ISO/IEC 15118 ed 1, CHAdeMO 1.2, GBT27930, GBT 34657
EVA 54180SDIN 70121, ISO/IEC 15118 ed 1, CHAdeMO 1.2, GBT27930, GBT 34657
Charging System
EVA 5460SIEC 61851-1 ed 3, IEC 61851-21-2 ed 1, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-2, IEC 62196-3, IEC 61000,GBT18487, GBT20234
EVA 5490SIEC 61851-1 ed 3, IEC 61851-21-2 ed 1, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-2, IEC 62196-3, IEC 61000,GBT18487, GBT20234
EVA 54120SIEC 61851-1 ed 3, IEC 61851-21-2 ed 1, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-2, IEC 62196-3, IEC 61000,GBT18487, GBT20234
EVA 54180SIEC 61851-1 ed 3, IEC 61851-21-2 ed 1, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-2, IEC 62196-3, IEC 61000,GBT18487, GBT20234
Brochure EVA 5460S-EVA 5490S-EVA 54120S-EVA 54180S Brochure
Manual EVA 5460S-5490S-54120S-54180S_manual
Related Products