- Select Capacity
- EVA 5460S
- EVA 5490S
- EVA 54120S
- EVA 54180S
- Select Capacity
- EVA 5460S
- EVA 5490S
- EVA 54120S
- EVA 54180S
235
EVA 5460S-EVA 5490S-EVA 54120S-EVA 54180S
IP54, 60kw-180kw DC EV charger
EV charger series occupied with Voltronic’s fully self-developed CCS controller and OCPP to ensure product stability and avoid maintenance risks. Patent ECO Energy Saving Mode to reduce energy consumption. Once vehicle charging is complete, the charging station will go into sleep mode (consumption 12W) even with the nozzle connected. The charging station will resume charging if the nozzle is connected to another vehicle. Moreover, the patent modularized the design of the charging module will facilitate replacement and lower maintenance costs.

Main Features
- Patent ECO energy saving mode: Once vehicle charging is complete, the charging station will go into sleep mode (consumption 12W ) even with nozzle connected. The charging station will resume charging if the nozzle is connected to another vehicle
- Patent full-modularized design including control system, power source system, distributed power system, power factor system
- In-house developed controllers, CCS and OCPP charging modules
- Supports multiple charging standards: GB, CCS1, CCS2 and CHAdeMO
- The charger had successfully passed 33 sets of rigorous environmental and thermal shock tests from -35°C to 55°to ensure the system reliability
- The DC power module is equipped with UL approved epoxy resin automatic injection to sustain the dusty and salty air tests to improve environmental adaptability
- IP54 protection, IK10 for cabinet and IK08 for touch screen
- Each charging mode with dedicated LED status indicator light (easy and intuitive charging experience)
- Multilingual support for 7 colored touch LCD
- Maximum efficiency up to 95%
- Input power factor 0.99
- THDi 5% at full load
- Built-in RFID card reader
- Supports OCPP 1.6 JSON network and 3G/4G
- Adapting OCPP network security protocol to implement the OTA feature
- The charger had successfully passed cloud network protocol test and was verified by OCTT
- The charger had passed vehicle end protocol DIN 70121, ISO15118, and was verified by TUV
- The Linux 5.10 OS and CPU conformed with cybersecurity standards
- Third-party certified CE EN61851
MODEL | EVA 5460S | EVA 5490S | EVA 54120S | EVA 54180S | |
Charging Type | DC fast charging | DC fast charging | DC fast charging | DC fast charging | |
Connector Type | 3P + N + PE | 3P + N + PE | 3P + N + PE | 3P + N + PE | |
Outlet Options | C: CCS2 cable, A: CCS1 cable, J:CHAdeMO cable, G: GBT cable | C: CCS2 cable, A: CCS1 cable, J:CHAdeMO cable, G: GBT cable | C: CCS2 cable, A: CCS1 cable, J:CHAdeMO cable, G: GBT cable | C: CCS2 cable, A: CCS1 cable, J:CHAdeMO cable, G: GBT cable | |
Overvoltage Category | Type II | Type II | Type II | Type II | |
AC Input/output Power Rating | 93 A, 64 kVA @ 400V 50 Hz | 139 A, 96 kVA @ 400V 50 Hz | 185 A, 128 kVA @ 400V 50Hz | 278 A, 192 kVA @ 400V 50Hz | |
Cellular Communication | GSM, 4G, LTE | GSM, 4G, LTE | GSM, 4G, LTE | GSM, 4G, LTE | |
Input/ouput voltage | 400 VAC or 380 VAC ± 10% | 400 VAC or 380 VAC ± 10% | 400 VAC or 380 VAC ± 10% | 400 VAC or 380 VAC ± 10% | |
Input Frequency | 50 Hz or 60 Hz | 50 Hz or 60 Hz | 50 Hz or 60 Hz | 50 Hz or 60 Hz | |
Number of EV Served | Up to 2 (CC, AA, JC, JJ ,GG models) Up to 1 (C, A, G models) | Up to 2 (CC, AA, JC, JJ ,GG models) Up to 1 (C, A, G models) | Up to 2 (CC, AA, JC, JJ ,GG models) Up to 1 (C, A, G models) | Up to 2 (CC, AA, JC, JJ ,GG models) Up to 1 (C, A, G models) | |
Cable Length | 5 m default, optional 6.0 m/ 7.0 m | 5 m default, optional 6.0 m/ 7.0 m | 5 m default, optional 6.0 m/ 7.0 m | 5 m default, optional 6.0 m/ 7.0 m | |
Maximum Current | CCS Cables | 150 A | 150 A, Optional: 200A | 200 A | 200 A, Optional: 300 A |
Maximum Current | CHAdeMO Cables | 125 A | 125 A | 125 A, Optional: 200 A | 125 A, Optional: 200 A |
Maximum Current | GBT Cables | 150 A | 150 A | 250 A | 250 A |
Electro-Magnetic Compatibility | Class A (optional Class B) according to EN 61000-6-3:2007 | Class A (optional Class B) according to EN 61000-6-3:2007 | Class A (optional Class B) according to EN 61000-6-3:2007 | Class A (optional Class B) according to EN 61000-6-3:2007 | |
Distribution Systems | TN-S. TN-C, TN-C-S, TT (required external RCD) | TN-S. TN-C, TN-C-S, TT (required external RCD) | TN-S. TN-C, TN-C-S, TT (required external RCD) | TN-S. TN-C, TN-C-S, TT (required external RCD) | |
Protection | Overcurrent, overvoltage, undervoltage, integrated surge protection, grounding fault including DC leakage protection, door opening protection | Overcurrent, overvoltage, undervoltage, integrated surge protection, grounding fault including DC leakage protection, door opening protection | Overcurrent, overvoltage, undervoltage, integrated surge protection, grounding fault including DC leakage protection, door opening protection | Overcurrent, overvoltage, undervoltage, integrated surge protection, grounding fault including DC leakage protection, door opening protection | |
Energy Metering | Standard: Meter for DC outlet, Optional: AC inlet | Standard: Meter for DC outlet, Optional: AC inlet | Standard: Meter for DC outlet, Optional: AC inlet | Standard: Meter for DC outlet, Optional: AC inlet | |
DC Output Power Rating(MAX) | 60 kW | 90 kW | 120 kW | 180 kW | |
Power Factor (Full Load) | ≥ 0.99 | ≥ 0.99 | ≥ 0.99 | ≥ 0.99 | |
THDi | ≤ 5% | ≤ 5% | ≤ 5% | ≤ 5% | |
Efficiency | 94% (peak) | 94% (peak) | 94% (peak) | 95% (peak) | |
Standby Power | < 35 W | < 35 W | < 35 W | < 35 W | |
Short Circuit Current | 10 kA | 10 kA | 10 kA | 10 kA | |
Pre-charge Current | < 1 A | < 1 A | < 1 A | < 1 A | |
Inrush Current | < 100 A | < 100 A | < 100 A | < 100 A | |
Leakage Current | 0.8 mA | 0.8 mA | 0.8 mA | 0.8 mA | |
USER INTERFACE | |||||
RFID Reader | ISO/IEC 14443 A/B Mifare RFID reader | ISO/IEC 14443 A/B Mifare RFID reader | ISO/IEC 14443 A/B Mifare RFID reader | ISO/IEC 14443 A/B Mifare RFID reader | |
User Authentication | RFID, QR code | RFID, QR code | RFID, QR code | RFID, QR code | |
Emergency Button | Yes | Yes | Yes | Yes | |
Connectivity | Internet access via 4G/3G/Ethernet (RJ45) | Internet access via 4G/3G/Ethernet (RJ45) | Internet access via 4G/3G/Ethernet (RJ45) | Internet access via 4G/3G/Ethernet (RJ45) | |
User Interface | 7" LCD high-contrast touchscreen | 7" LCD high-contrast touchscreen | 7" LCD high-contrast touchscreen | 7" LCD high-contrast touchscreen | |
Communiation Protocols | Proprietary and OCPP 1.6J | Proprietary and OCPP 1.6J | Proprietary and OCPP 1.6J | Proprietary and OCPP 1.6J | |
GENERAL CHARACTERISTICS | |||||
Mounting | Free-standing cabinet | Free-standing cabinet | Free-standing cabinet | Free-standing cabinet | |
Operating Altitude | Up to 2000m | Up to 2000m | Up to 2000m | Up to 2000m | |
Humidity | < 95%, non-condensing | < 95%, non-condensing | < 95%, non-condensing | < 95%, non-condensing | |
Protection Rating | IP54 and IK10 (cabinet) / IK8 (touchscreen) | IP54 and IK10 (cabinet) / IK8 (touchscreen) | IP54 and IK10 (cabinet) / IK8 (touchscreen) | IP54 and IK10 (cabinet) / IK8 (touchscreen) | |
Operating Temperature | -35 °C to 55 °C | -35 °C to 55 °C | -35 °C to 55 °C | -35 °C to 55 °C | |
Net Weight (kgs) | 295 | 335 | 355 | 395 | |
Housing Material | SGCC, Optional: SUS430 | SGCC, Optional: SUS430 | SGCC, Optional: SUS430 | SGCC, Optional: SUS430 | |
Storage Temperature | -40 °C to 70 °C | -40 °C to 70 °C | -40 °C to 70 °C | -40 °C to 70 °C | |
Dimensions (D x W x H) mm | 750 x 740 x 1830 | 750 x 740 x 1830 | 750 x 740 x 1830 | 750 x 740 x 1830 | |
COMPLIANCE STANDARDS | |||||
Safety Standards | DIN 70121, ISO/IEC 15118 ed 1, CHAdeMO 1.2, GBT27930, GBT 34657 | DIN 70121, ISO/IEC 15118 ed 1, CHAdeMO 1.2, GBT27930, GBT 34657 | DIN 70121, ISO/IEC 15118 ed 1, CHAdeMO 1.2, GBT27930, GBT 34657 | DIN 70121, ISO/IEC 15118 ed 1, CHAdeMO 1.2, GBT27930, GBT 34657 | |
Charging System | IEC 61851-1 ed 3, IEC 61851-21-2 ed 1, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-2, IEC 62196-3, IEC 61000,GBT18487, GBT20234 | IEC 61851-1 ed 3, IEC 61851-21-2 ed 1, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-2, IEC 62196-3, IEC 61000,GBT18487, GBT20234 | IEC 61851-1 ed 3, IEC 61851-21-2 ed 1, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-2, IEC 62196-3, IEC 61000,GBT18487, GBT20234 | IEC 61851-1 ed 3, IEC 61851-21-2 ed 1, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-2, IEC 62196-3, IEC 61000,GBT18487, GBT20234 |
General
Charging Type
EVA 5460S | DC fast charging |
---|---|
EVA 5490S | DC fast charging |
EVA 54120S | DC fast charging |
EVA 54180S | DC fast charging |
Connector Type
EVA 5460S | 3P + N + PE |
---|---|
EVA 5490S | 3P + N + PE |
EVA 54120S | 3P + N + PE |
EVA 54180S | 3P + N + PE |
Outlet Options
EVA 5460S | C: CCS2 cable, A: CCS1 cable, J:CHAdeMO cable, G: GBT cable |
---|---|
EVA 5490S | C: CCS2 cable, A: CCS1 cable, J:CHAdeMO cable, G: GBT cable |
EVA 54120S | C: CCS2 cable, A: CCS1 cable, J:CHAdeMO cable, G: GBT cable |
EVA 54180S | C: CCS2 cable, A: CCS1 cable, J:CHAdeMO cable, G: GBT cable |
Overvoltage Category
EVA 5460S | Type II |
---|---|
EVA 5490S | Type II |
EVA 54120S | Type II |
EVA 54180S | Type II |
AC Input/output Power Rating
EVA 5460S | 93 A, 64 kVA @ 400V 50 Hz |
---|---|
EVA 5490S | 139 A, 96 kVA @ 400V 50 Hz |
EVA 54120S | 185 A, 128 kVA @ 400V 50Hz |
EVA 54180S | 278 A, 192 kVA @ 400V 50Hz |
Cellular Communication
EVA 5460S | GSM, 4G, LTE |
---|---|
EVA 5490S | GSM, 4G, LTE |
EVA 54120S | GSM, 4G, LTE |
EVA 54180S | GSM, 4G, LTE |
Input/ouput voltage
EVA 5460S | 400 VAC or 380 VAC ± 10% |
---|---|
EVA 5490S | 400 VAC or 380 VAC ± 10% |
EVA 54120S | 400 VAC or 380 VAC ± 10% |
EVA 54180S | 400 VAC or 380 VAC ± 10% |
Input Frequency
EVA 5460S | 50 Hz or 60 Hz |
---|---|
EVA 5490S | 50 Hz or 60 Hz |
EVA 54120S | 50 Hz or 60 Hz |
EVA 54180S | 50 Hz or 60 Hz |
Number of EV Served
EVA 5460S | Up to 2 (CC, AA, JC, JJ ,GG models) Up to 1 (C, A, G models) |
---|---|
EVA 5490S | Up to 2 (CC, AA, JC, JJ ,GG models) Up to 1 (C, A, G models) |
EVA 54120S | Up to 2 (CC, AA, JC, JJ ,GG models) Up to 1 (C, A, G models) |
EVA 54180S | Up to 2 (CC, AA, JC, JJ ,GG models) Up to 1 (C, A, G models) |
Cable Length
EVA 5460S | 5 m default, optional 6.0 m/ 7.0 m |
---|---|
EVA 5490S | 5 m default, optional 6.0 m/ 7.0 m |
EVA 54120S | 5 m default, optional 6.0 m/ 7.0 m |
EVA 54180S | 5 m default, optional 6.0 m/ 7.0 m |
Maximum Current CCS Cables
EVA 5460S | 150 A |
---|---|
EVA 5490S | 150 A, Optional: 200A |
EVA 54120S | 200 A |
EVA 54180S | 200 A, Optional: 300 A |
Maximum Current CHAdeMO Cables
EVA 5460S | 125 A |
---|---|
EVA 5490S | 125 A |
EVA 54120S | 125 A, Optional: 200 A |
EVA 54180S | 125 A, Optional: 200 A |
Maximum Current GBT Cables
EVA 5460S | 150 A |
---|---|
EVA 5490S | 150 A |
EVA 54120S | 250 A |
EVA 54180S | 250 A |
Electro-Magnetic Compatibility
EVA 5460S | Class A (optional Class B) according to EN 61000-6-3:2007 |
---|---|
EVA 5490S | Class A (optional Class B) according to EN 61000-6-3:2007 |
EVA 54120S | Class A (optional Class B) according to EN 61000-6-3:2007 |
EVA 54180S | Class A (optional Class B) according to EN 61000-6-3:2007 |
Distribution Systems
EVA 5460S | TN-S. TN-C, TN-C-S, TT (required external RCD) |
---|---|
EVA 5490S | TN-S. TN-C, TN-C-S, TT (required external RCD) |
EVA 54120S | TN-S. TN-C, TN-C-S, TT (required external RCD) |
EVA 54180S | TN-S. TN-C, TN-C-S, TT (required external RCD) |
Protection
EVA 5460S | Overcurrent, overvoltage, undervoltage, integrated surge protection, grounding fault including DC leakage protection, door opening protection |
---|---|
EVA 5490S | Overcurrent, overvoltage, undervoltage, integrated surge protection, grounding fault including DC leakage protection, door opening protection |
EVA 54120S | Overcurrent, overvoltage, undervoltage, integrated surge protection, grounding fault including DC leakage protection, door opening protection |
EVA 54180S | Overcurrent, overvoltage, undervoltage, integrated surge protection, grounding fault including DC leakage protection, door opening protection |
Energy Metering
EVA 5460S | Standard: Meter for DC outlet, Optional: AC inlet |
---|---|
EVA 5490S | Standard: Meter for DC outlet, Optional: AC inlet |
EVA 54120S | Standard: Meter for DC outlet, Optional: AC inlet |
EVA 54180S | Standard: Meter for DC outlet, Optional: AC inlet |
DC Output Power Rating(MAX)
EVA 5460S | 60 kW |
---|---|
EVA 5490S | 90 kW |
EVA 54120S | 120 kW |
EVA 54180S | 180 kW |
Power Factor (Full Load)
EVA 5460S | ≥ 0.99 |
---|---|
EVA 5490S | ≥ 0.99 |
EVA 54120S | ≥ 0.99 |
EVA 54180S | ≥ 0.99 |
THDi
EVA 5460S | ≤ 5% |
---|---|
EVA 5490S | ≤ 5% |
EVA 54120S | ≤ 5% |
EVA 54180S | ≤ 5% |
Efficiency
EVA 5460S | 94% (peak) |
---|---|
EVA 5490S | 94% (peak) |
EVA 54120S | 94% (peak) |
EVA 54180S | 95% (peak) |
Standby Power
EVA 5460S | < 35 W |
---|---|
EVA 5490S | < 35 W |
EVA 54120S | < 35 W |
EVA 54180S | < 35 W |
Short Circuit Current
EVA 5460S | 10 kA |
---|---|
EVA 5490S | 10 kA |
EVA 54120S | 10 kA |
EVA 54180S | 10 kA |
Pre-charge Current
EVA 5460S | < 1 A |
---|---|
EVA 5490S | < 1 A |
EVA 54120S | < 1 A |
EVA 54180S | < 1 A |
Inrush Current
EVA 5460S | < 100 A |
---|---|
EVA 5490S | < 100 A |
EVA 54120S | < 100 A |
EVA 54180S | < 100 A |
Leakage Current
EVA 5460S | 0.8 mA |
---|---|
EVA 5490S | 0.8 mA |
EVA 54120S | 0.8 mA |
EVA 54180S | 0.8 mA |
USER INTERFACE
RFID Reader
EVA 5460S | ISO/IEC 14443 A/B Mifare RFID reader |
---|---|
EVA 5490S | ISO/IEC 14443 A/B Mifare RFID reader |
EVA 54120S | ISO/IEC 14443 A/B Mifare RFID reader |
EVA 54180S | ISO/IEC 14443 A/B Mifare RFID reader |
User Authentication
EVA 5460S | RFID, QR code |
---|---|
EVA 5490S | RFID, QR code |
EVA 54120S | RFID, QR code |
EVA 54180S | RFID, QR code |
Emergency Button
EVA 5460S | Yes |
---|---|
EVA 5490S | Yes |
EVA 54120S | Yes |
EVA 54180S | Yes |
Connectivity
EVA 5460S | Internet access via 4G/3G/Ethernet (RJ45) |
---|---|
EVA 5490S | Internet access via 4G/3G/Ethernet (RJ45) |
EVA 54120S | Internet access via 4G/3G/Ethernet (RJ45) |
EVA 54180S | Internet access via 4G/3G/Ethernet (RJ45) |
User Interface
EVA 5460S | 7" LCD high-contrast touchscreen |
---|---|
EVA 5490S | 7" LCD high-contrast touchscreen |
EVA 54120S | 7" LCD high-contrast touchscreen |
EVA 54180S | 7" LCD high-contrast touchscreen |
Communiation Protocols
EVA 5460S | Proprietary and OCPP 1.6J |
---|---|
EVA 5490S | Proprietary and OCPP 1.6J |
EVA 54120S | Proprietary and OCPP 1.6J |
EVA 54180S | Proprietary and OCPP 1.6J |
GENERAL CHARACTERISTICS
Mounting
EVA 5460S | Free-standing cabinet |
---|---|
EVA 5490S | Free-standing cabinet |
EVA 54120S | Free-standing cabinet |
EVA 54180S | Free-standing cabinet |
Operating Altitude
EVA 5460S | Up to 2000m |
---|---|
EVA 5490S | Up to 2000m |
EVA 54120S | Up to 2000m |
EVA 54180S | Up to 2000m |
Humidity
EVA 5460S | < 95%, non-condensing |
---|---|
EVA 5490S | < 95%, non-condensing |
EVA 54120S | < 95%, non-condensing |
EVA 54180S | < 95%, non-condensing |
Protection Rating
EVA 5460S | IP54 and IK10 (cabinet) / IK8 (touchscreen) |
---|---|
EVA 5490S | IP54 and IK10 (cabinet) / IK8 (touchscreen) |
EVA 54120S | IP54 and IK10 (cabinet) / IK8 (touchscreen) |
EVA 54180S | IP54 and IK10 (cabinet) / IK8 (touchscreen) |
Operating Temperature
EVA 5460S | -35 °C to 55 °C |
---|---|
EVA 5490S | -35 °C to 55 °C |
EVA 54120S | -35 °C to 55 °C |
EVA 54180S | -35 °C to 55 °C |
Net Weight (kgs)
EVA 5460S | 295 |
---|---|
EVA 5490S | 335 |
EVA 54120S | 355 |
EVA 54180S | 395 |
Housing Material
EVA 5460S | SGCC, Optional: SUS430 |
---|---|
EVA 5490S | SGCC, Optional: SUS430 |
EVA 54120S | SGCC, Optional: SUS430 |
EVA 54180S | SGCC, Optional: SUS430 |
Storage Temperature
EVA 5460S | -40 °C to 70 °C |
---|---|
EVA 5490S | -40 °C to 70 °C |
EVA 54120S | -40 °C to 70 °C |
EVA 54180S | -40 °C to 70 °C |
Dimensions (D x W x H) mm
EVA 5460S | 750 x 740 x 1830 |
---|---|
EVA 5490S | 750 x 740 x 1830 |
EVA 54120S | 750 x 740 x 1830 |
EVA 54180S | 750 x 740 x 1830 |
COMPLIANCE STANDARDS
Safety Standards
EVA 5460S | DIN 70121, ISO/IEC 15118 ed 1, CHAdeMO 1.2, GBT27930, GBT 34657 |
---|---|
EVA 5490S | DIN 70121, ISO/IEC 15118 ed 1, CHAdeMO 1.2, GBT27930, GBT 34657 |
EVA 54120S | DIN 70121, ISO/IEC 15118 ed 1, CHAdeMO 1.2, GBT27930, GBT 34657 |
EVA 54180S | DIN 70121, ISO/IEC 15118 ed 1, CHAdeMO 1.2, GBT27930, GBT 34657 |
Charging System
EVA 5460S | IEC 61851-1 ed 3, IEC 61851-21-2 ed 1, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-2, IEC 62196-3, IEC 61000,GBT18487, GBT20234 |
---|---|
EVA 5490S | IEC 61851-1 ed 3, IEC 61851-21-2 ed 1, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-2, IEC 62196-3, IEC 61000,GBT18487, GBT20234 |
EVA 54120S | IEC 61851-1 ed 3, IEC 61851-21-2 ed 1, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-2, IEC 62196-3, IEC 61000,GBT18487, GBT20234 |
EVA 54180S | IEC 61851-1 ed 3, IEC 61851-21-2 ed 1, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-2, IEC 62196-3, IEC 61000,GBT18487, GBT20234 |
![]() |
Brochure | EVA 5460S-EVA 5490S-EVA 54120S-EVA 54180S Brochure |
![]() |
Manual | EVA 5460S-5490S-54120S-54180S_manual |
DC EV Charger EVA 5460S-EVA 5490S-EVA 54120S-EVA 54180S IP54, 60kw-180kw DC EV charger
Related Products
We have received your membership application and will reply as soon as within 24 hours, before that, please browse our website, thank you.