CFL UPS
40W DC Standby UPS
The CFL UPS is specifically designed for lighting purposes. It features an on-box lamp holder that allows you to directly plug in an energy-saving bulb, providing 360-degree illumination. Additionally, it includes three sockets that serve as extensions, enabling you to connect to three CFL lights at the same time. This makes it an ideal option for emergency lighting, home lighting, camping, street vending, or street lighting in remote villages.
Main Features
- 40W DC UPS
- Features a lamp holder compatible with energy-saving bulbs
- Includes three DC-powered outlets designed for energy-saving bulbs
- Supports charging while in off mode
- Provides overload protection during battery operation and short circuit protection
- Equipped with three indicator lights
- Utilizes a three-step charging system to enhance battery longevity
| MODEL | CFL UPS | |
| CAPACITY | 50 VA/40 W | |
| INPUT | ||
| Voltage | 230 VAC | |
| Voltage Range | 100 VAC-300 VAC | |
| OUTPUT | ||
| Output Voltage (AC Mode) | 100 VDC-300 VDC | |
| Waveform | DC Output | |
| Output Voltage (Batt. Mode) | 160-230 VDC ± 10% | |
| BATTERY & CHARGER | ||
| Battery Type & Number | 12V 7Ah x 1 | |
| Typical Charging Time | 6 hours recover to 90% capacity | |
| Floating Charge Voltage | 13.7 VDC ± 1.5% | |
| Charging Current | 1 A | |
| Bulk charging voltage | 14.5 VDC ± 1.5% | |
| Battery Voltage | 12 VDC | |
| INDICATORS | ||
| Low Battery (Batt. Mode) | Yellow flashing every second | |
| Normal battery voltage at Battery Mode | Yellow lighting | |
| Output short-circuited | Red lighting | |
| Overcharge | Red LED staying on for one second and off for 4 seconds | |
| Overload | Red flashing rapidly every 0.5 second | |
| Charging battery at Line Mode | Green flashing every 2 seconds | |
| Full battery at Line Mode | Green lighting | |
| PHYSICAL | ||
| Dimension, D X W X H (mm) | 209 x 87 x 200 | |
| Net Weight (kgs) | 2.7 | |
| OPERATING ENVIRONMENT | ||
| Operating Humidity | 0~90% RH @ 0- 40°C (non-condensing) | |
| Noise Level | Less than 40dB | |
General
CAPACITY
| CFL UPS | 50 VA/40 W |
|---|
INPUT
Voltage
| CFL UPS | 230 VAC |
|---|
Voltage Range
| CFL UPS | 100 VAC-300 VAC |
|---|
OUTPUT
Output Voltage (AC Mode)
| CFL UPS | 100 VDC-300 VDC |
|---|
Waveform
| CFL UPS | DC Output |
|---|
Output Voltage (Batt. Mode)
| CFL UPS | 160-230 VDC ± 10% |
|---|
BATTERY & CHARGER
Battery Type & Number
| CFL UPS | 12V 7Ah x 1 |
|---|
Typical Charging Time
| CFL UPS | 6 hours recover to 90% capacity |
|---|
Floating Charge Voltage
| CFL UPS | 13.7 VDC ± 1.5% |
|---|
Charging Current
| CFL UPS | 1 A |
|---|
Bulk charging voltage
| CFL UPS | 14.5 VDC ± 1.5% |
|---|
Battery Voltage
| CFL UPS | 12 VDC |
|---|
INDICATORS
Low Battery (Batt. Mode)
| CFL UPS | Yellow flashing every second |
|---|
Normal battery voltage at Battery Mode
| CFL UPS | Yellow lighting |
|---|
Output short-circuited
| CFL UPS | Red lighting |
|---|
Overcharge
| CFL UPS | Red LED staying on for one second and off for 4 seconds |
|---|
Overload
| CFL UPS | Red flashing rapidly every 0.5 second |
|---|
Charging battery at Line Mode
| CFL UPS | Green flashing every 2 seconds |
|---|
Full battery at Line Mode
| CFL UPS | Green lighting |
|---|
PHYSICAL
Dimension, D X W X H (mm)
| CFL UPS | 209 x 87 x 200 |
|---|
Net Weight (kgs)
| CFL UPS | 2.7 |
|---|
OPERATING ENVIRONMENT
Operating Humidity
| CFL UPS | 0~90% RH @ 0- 40°C (non-condensing) |
|---|
Noise Level
| CFL UPS | Less than 40dB |
|---|
| Brochure | CFL UPS_Brochure | |
| Manual | CFL UPS_Manual |