- Select Capacity
- VM II-4000 TWIN-PV 5600
- VM II-6000 TWIN-PV 8000
- Select Capacity
- VM II-4000 TWIN-PV 5600
- VM II-6000 TWIN-PV 8000
201
Axpert VM II-4K/6K TWIN-PV 5600/8000 (Single-Phase)
Built-in a 120A MPPT solar charger with a maximum PV input current of 40A
The Axpert VM II TWIN is a flexible solar power system engineered for effective energy management. It offers a high photovoltaic input capacity of up to 8000W, dual output channels for intelligent load balancing, integrated WiFi for remote monitoring and convenient updates, and BMS communication to support battery integration. Its design allows for battery-independent operation, enabling versatile system setups. Additionally, it features meter calibration to enhance performance and an anti-dust kit to improve durability. Overall, it is a robust and adaptable option for solar energy applications.
Main Features
- Enhanced PV power capacity to 5600W and 8000W depending on the model
- Maximum PV input current of 40A
- Dual outputs for intelligent load management
- Integrated Wi-Fi for mobile monitoring and over-the-air firmware updates; supports USB On-the-Go functionality
- Includes built-in BMS communication port
- Equipped with built-in meter calibration to optimize system performance
- Designed to operate independently of the battery
- Features a built-in anti-dust kit
| MODEL | VM II-4000 TWIN-PV 5600 | VM II-6000 TWIN-PV 8000 | |
| Rated Power | 4000VA/4000W | 6000VA/6000W | |
| INPUT | |||
| Voltage | 230 VAC | 230 VAC | |
| Selectable Voltage Range | 170-280 VAC (For Personal Computers); 90-280 VAC (For Home Appliances) | 170-280 VAC (For Personal Computers); 90-280 VAC (For Home Appliances) | |
| Frequency Range | 50 Hz/60 Hz (Auto sensing) | 50 Hz/60 Hz (Auto sensing) | |
| OUTPUT | |||
| AC Voltage Regulation (Batt. Mode) | 230 VAC ± 5% | 230 VAC ± 5% | |
| Surge Power | 93% | 93% | |
| Efficiency (Peak) | 10 ms (For Personal Computers); 20 ms (For Home Appliances) | 10 ms (For Personal Computers); 20 ms (For Home Appliances) | |
| Transfer Time | Pure Sine Wave | Pure Sine Wave | |
| Waveform | 8000VA | 12000VA | |
| Dual Outputs | Yes | Yes | |
| BATTERY | |||
| Battery Voltage | 24 VDC | 48 VDC | |
| Floating Charge Voltage | 27 VDC | 54 VDC | |
| Overcharge Protection | 33 VDC | 63 VDC | |
| SOLAR CHARGER & AC CHARGER | |||
| Solar Charger Type | MPPT | MPPT | |
| Maximum PV Array Open Circuit Voltage | 500 VDC | 500 VDC | |
| Maximum PV Array Power | 5600W | 8000W | |
| MPPT Range @ Operating Voltage | 60-450 VDC | 60-450 VDC | |
| Maximum Solar Charge Current | 120A | 120A | |
| Maximum AC Charge Current | 100A | 100A | |
| Maximum Charging Current | 120A | 120A | |
| Maximum PV Input Current | 122 x 322.7 x 420.3 | 122 x 322.7 x 420.3 | |
| PHYSICAL | |||
| Dimension, D X W X H (mm) | 9.5 | 10.5 | |
| Net Weight (kgs) | USB/RS232/RS485/Wi-Fi | USB/RS232/RS485/Wi-Fi | |
| Communication Port | 5% to 95% Relative Humidity(Non-condensing) | 5% to 95% Relative Humidity(Non-condensing) | |
| OPERATING ENVIRONMENT | |||
| Operating Humidity | -10℃ to 50℃ | -10℃ to 50℃ | |
| Operating Temperature | -15℃ to 60℃ | -15℃ to 60℃ | |
| Storage Temperature | -15℃ to 60℃ | -15℃ to 60℃ | |
General
Rated Power
| VM II-4000 TWIN-PV 5600 | 4000VA/4000W |
|---|---|
| VM II-6000 TWIN-PV 8000 | 6000VA/6000W |
INPUT
Voltage
| VM II-4000 TWIN-PV 5600 | 230 VAC |
|---|---|
| VM II-6000 TWIN-PV 8000 | 230 VAC |
Selectable Voltage Range
| VM II-4000 TWIN-PV 5600 | 170-280 VAC (For Personal Computers); 90-280 VAC (For Home Appliances) |
|---|---|
| VM II-6000 TWIN-PV 8000 | 170-280 VAC (For Personal Computers); 90-280 VAC (For Home Appliances) |
Frequency Range
| VM II-4000 TWIN-PV 5600 | 50 Hz/60 Hz (Auto sensing) |
|---|---|
| VM II-6000 TWIN-PV 8000 | 50 Hz/60 Hz (Auto sensing) |
OUTPUT
AC Voltage Regulation (Batt. Mode)
| VM II-4000 TWIN-PV 5600 | 230 VAC ± 5% |
|---|---|
| VM II-6000 TWIN-PV 8000 | 230 VAC ± 5% |
Surge Power
| VM II-4000 TWIN-PV 5600 | 93% |
|---|---|
| VM II-6000 TWIN-PV 8000 | 93% |
Efficiency (Peak)
| VM II-4000 TWIN-PV 5600 | 10 ms (For Personal Computers); 20 ms (For Home Appliances) |
|---|---|
| VM II-6000 TWIN-PV 8000 | 10 ms (For Personal Computers); 20 ms (For Home Appliances) |
Transfer Time
| VM II-4000 TWIN-PV 5600 | Pure Sine Wave |
|---|---|
| VM II-6000 TWIN-PV 8000 | Pure Sine Wave |
Waveform
| VM II-4000 TWIN-PV 5600 | 8000VA |
|---|---|
| VM II-6000 TWIN-PV 8000 | 12000VA |
Dual Outputs
| VM II-4000 TWIN-PV 5600 | Yes |
|---|---|
| VM II-6000 TWIN-PV 8000 | Yes |
BATTERY
Battery Voltage
| VM II-4000 TWIN-PV 5600 | 24 VDC |
|---|---|
| VM II-6000 TWIN-PV 8000 | 48 VDC |
Floating Charge Voltage
| VM II-4000 TWIN-PV 5600 | 27 VDC |
|---|---|
| VM II-6000 TWIN-PV 8000 | 54 VDC |
Overcharge Protection
| VM II-4000 TWIN-PV 5600 | 33 VDC |
|---|---|
| VM II-6000 TWIN-PV 8000 | 63 VDC |
SOLAR CHARGER & AC CHARGER
Solar Charger Type
| VM II-4000 TWIN-PV 5600 | MPPT |
|---|---|
| VM II-6000 TWIN-PV 8000 | MPPT |
Maximum PV Array Open Circuit Voltage
| VM II-4000 TWIN-PV 5600 | 500 VDC |
|---|---|
| VM II-6000 TWIN-PV 8000 | 500 VDC |
Maximum PV Array Power
| VM II-4000 TWIN-PV 5600 | 5600W |
|---|---|
| VM II-6000 TWIN-PV 8000 | 8000W |
MPPT Range @ Operating Voltage
| VM II-4000 TWIN-PV 5600 | 60-450 VDC |
|---|---|
| VM II-6000 TWIN-PV 8000 | 60-450 VDC |
Maximum Solar Charge Current
| VM II-4000 TWIN-PV 5600 | 120A |
|---|---|
| VM II-6000 TWIN-PV 8000 | 120A |
Maximum AC Charge Current
| VM II-4000 TWIN-PV 5600 | 100A |
|---|---|
| VM II-6000 TWIN-PV 8000 | 100A |
Maximum Charging Current
| VM II-4000 TWIN-PV 5600 | 120A |
|---|---|
| VM II-6000 TWIN-PV 8000 | 120A |
Maximum PV Input Current
| VM II-4000 TWIN-PV 5600 | 122 x 322.7 x 420.3 |
|---|---|
| VM II-6000 TWIN-PV 8000 | 122 x 322.7 x 420.3 |
PHYSICAL
Dimension, D X W X H (mm)
| VM II-4000 TWIN-PV 5600 | 9.5 |
|---|---|
| VM II-6000 TWIN-PV 8000 | 10.5 |
Net Weight (kgs)
| VM II-4000 TWIN-PV 5600 | USB/RS232/RS485/Wi-Fi |
|---|---|
| VM II-6000 TWIN-PV 8000 | USB/RS232/RS485/Wi-Fi |
Communication Port
| VM II-4000 TWIN-PV 5600 | 5% to 95% Relative Humidity(Non-condensing) |
|---|---|
| VM II-6000 TWIN-PV 8000 | 5% to 95% Relative Humidity(Non-condensing) |
OPERATING ENVIRONMENT
Operating Humidity
| VM II-4000 TWIN-PV 5600 | -10℃ to 50℃ |
|---|---|
| VM II-6000 TWIN-PV 8000 | -10℃ to 50℃ |
Operating Temperature
| VM II-4000 TWIN-PV 5600 | -15℃ to 60℃ |
|---|---|
| VM II-6000 TWIN-PV 8000 | -15℃ to 60℃ |
Storage Temperature
| VM II-4000 TWIN-PV 5600 | -15℃ to 60℃ |
|---|---|
| VM II-6000 TWIN-PV 8000 | -15℃ to 60℃ |
| Brochure | Axpert VM II TWIN | |
| Manual | Axpert VM II TWIN (40A) |
Off-Grid Inverter Axpert VM II-4K/6K TWIN-PV 5600/8000 (Single-Phase) Built-in a 120A MPPT solar charger with a maximum PV input current of 40A
Related Products
We have received your membership application and will reply as soon as within 24 hours, before that, please browse our website, thank you.