253
Axpert King II TWIN 6KW/6.2KW
Dual outputs for smart load management
Axpert King II TWIN is designed with zero transfer time which is perfect for critical devices such as servers and ATMs. It’s equipped with a powerful 120A solar charger and 120A AC charger. The detachable LCD control module allows users to monitor this inverter remotely. It can also expand power capacity to 54KW/55.8KW with 9 units in parallel operation. Axpert King II TWIN is occupied with two outputs. The second output can be scheduled on/off, setting cut-off voltage or SOC and discharging time via LCD setting.


Main Features
- Dual outputs, for smart load management
- Maximum PV input current increases to 27A
- Zero (0ms) transfer time to protect mission-critical loads such as servers and ATMs
- High PV input voltage range
- Detachable LCD control module with multiple communications
- Selectable high power charging current
- Built-in Wi-Fi for mobile monitoring (App is available)
- Configurable AC/Solar input priority via LCD setting
- Reserved communication port for BMS (RS485 or CAN-BUS)
- USB On-the-Go function
- Parallel operation up to 9 units
MODEL | Axpert KING II TWIN 6K | Axpert KING II TWIN 6.2K | |
Rated Power | 6000VA/6000W | 6200VA/6200W | |
Parallel Capability | Up to 9 units | Up to 9 units | |
INPUT | |||
Voltage | 230 VAC | 230 VAC | |
Voltage Range | 110-280 VAC | 110-280 VAC | |
Frequency Range | 50 Hz/60 Hz (Auto sensing) ± 4Hz | 50 Hz/60 Hz (Auto sensing) ± 4Hz | |
Power Factor | ≧ 0.98 @ Nominal Voltage (100% Load) | ≧ 0.98 @ Nominal Voltage (100% Load) | |
THDi | ≦ 10% | ≦ 10% | |
OUTPUT | |||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz | |
Waveform | Pure sine wave | Pure sine wave | |
Harmonic Distortion | ≦3 % THD (Linear Load); ≦ 5 % THD (Non-linear Load) | ≦3 % THD (Linear Load); ≦ 5 % THD (Non-linear Load) | |
Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz | |
AC Voltage Regulation (Line&Batt. Mode) | 230VAC ± 5% | 230VAC ± 5% | |
Transfer Time (AC Mode to Batt. Mode) | 0ms | 0ms | |
Transfer Time (Inverter to Bypass) | 4 ms (Typical) | 4 ms (Typical) | |
EFFICIENCY | |||
Battery Mode | 92% | 92% | |
ECO Mode | 98% | 98% | |
Line Mode | 94% | 94% | |
BATTERY | |||
Battery Voltage | 40~66 VDC | 40~66 VDC | |
Floating Charge Voltage | 54 VDC | 54 VDC | |
Overcharge Protection | 66 VDC | 66 VDC | |
PHYSICAL | |||
Dimension, D X W X H (mm) | 140 x 295 x 468 | 140 x 295 x 468 | |
Net Weight (kgs) | 12 | 12 | |
Communication Port | USB/RS232/RS485/WI-FI/Dry-contact | USB/RS232/RS485/WI-FI/Dry-contact | |
OPERATING ENVIRONMENT | |||
Operating Humidity | 5% to 95% Relative Humidity(Non-condensing) | 5% to 95% Relative Humidity(Non-condensing) | |
Operating Temperature | -10°C to 50°C | -10°C to 50°C | |
Storage Temperature | -15°C to 60°C | -15°C to 60°C | |
SOLAR INPUT | |||
Solar Charger type | MPPT | MPPT | |
Maximum PV Array Power | 6000 W | 6000 W | |
MPPT Range @ Operating Voltage | 120 ~ 430 VDC | 120 ~ 430 VDC | |
Maximum PV Array Open Circuit Voltage | 500 VDC | 500 VDC | |
Maxmum Solar Charge Current | 120A | 120A | |
Maximum AC Charge Current | 120A | 120A |
General
Rated Power
Axpert KING II TWIN 6K | 6000VA/6000W |
---|---|
Axpert KING II TWIN 6.2K | 6200VA/6200W |
Parallel Capability
Axpert KING II TWIN 6K | Up to 9 units |
---|---|
Axpert KING II TWIN 6.2K | Up to 9 units |
INPUT
Voltage
Axpert KING II TWIN 6K | 230 VAC |
---|---|
Axpert KING II TWIN 6.2K | 230 VAC |
Voltage Range
Axpert KING II TWIN 6K | 110-280 VAC |
---|---|
Axpert KING II TWIN 6.2K | 110-280 VAC |
Frequency Range
Axpert KING II TWIN 6K | 50 Hz/60 Hz (Auto sensing) ± 4Hz |
---|---|
Axpert KING II TWIN 6.2K | 50 Hz/60 Hz (Auto sensing) ± 4Hz |
Power Factor
Axpert KING II TWIN 6K | ≧ 0.98 @ Nominal Voltage (100% Load) |
---|---|
Axpert KING II TWIN 6.2K | ≧ 0.98 @ Nominal Voltage (100% Load) |
THDi
Axpert KING II TWIN 6K | ≦ 10% |
---|---|
Axpert KING II TWIN 6.2K | ≦ 10% |
OUTPUT
Frequency Range (Batt. Mode)
Axpert KING II TWIN 6K | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz |
---|---|
Axpert KING II TWIN 6.2K | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz |
Waveform
Axpert KING II TWIN 6K | Pure sine wave |
---|---|
Axpert KING II TWIN 6.2K | Pure sine wave |
Harmonic Distortion
Axpert KING II TWIN 6K | ≦3 % THD (Linear Load); ≦ 5 % THD (Non-linear Load) |
---|---|
Axpert KING II TWIN 6.2K | ≦3 % THD (Linear Load); ≦ 5 % THD (Non-linear Load) |
Frequency Range (Synchronized Range)
Axpert KING II TWIN 6K | 46~54 Hz or 56~64 Hz |
---|---|
Axpert KING II TWIN 6.2K | 46~54 Hz or 56~64 Hz |
AC Voltage Regulation (Line&Batt. Mode)
Axpert KING II TWIN 6K | 230VAC ± 5% |
---|---|
Axpert KING II TWIN 6.2K | 230VAC ± 5% |
Transfer Time (AC Mode to Batt. Mode)
Axpert KING II TWIN 6K | 0ms |
---|---|
Axpert KING II TWIN 6.2K | 0ms |
Transfer Time (Inverter to Bypass)
Axpert KING II TWIN 6K | 4 ms (Typical) |
---|---|
Axpert KING II TWIN 6.2K | 4 ms (Typical) |
EFFICIENCY
Battery Mode
Axpert KING II TWIN 6K | 92% |
---|---|
Axpert KING II TWIN 6.2K | 92% |
ECO Mode
Axpert KING II TWIN 6K | 98% |
---|---|
Axpert KING II TWIN 6.2K | 98% |
Line Mode
Axpert KING II TWIN 6K | 94% |
---|---|
Axpert KING II TWIN 6.2K | 94% |
BATTERY
Battery Voltage
Axpert KING II TWIN 6K | 40~66 VDC |
---|---|
Axpert KING II TWIN 6.2K | 40~66 VDC |
Floating Charge Voltage
Axpert KING II TWIN 6K | 54 VDC |
---|---|
Axpert KING II TWIN 6.2K | 54 VDC |
Overcharge Protection
Axpert KING II TWIN 6K | 66 VDC |
---|---|
Axpert KING II TWIN 6.2K | 66 VDC |
PHYSICAL
Dimension, D X W X H (mm)
Axpert KING II TWIN 6K | 140 x 295 x 468 |
---|---|
Axpert KING II TWIN 6.2K | 140 x 295 x 468 |
Net Weight (kgs)
Axpert KING II TWIN 6K | 12 |
---|---|
Axpert KING II TWIN 6.2K | 12 |
Communication Port
Axpert KING II TWIN 6K | USB/RS232/RS485/WI-FI/Dry-contact |
---|---|
Axpert KING II TWIN 6.2K | USB/RS232/RS485/WI-FI/Dry-contact |
OPERATING ENVIRONMENT
Operating Humidity
Axpert KING II TWIN 6K | 5% to 95% Relative Humidity(Non-condensing) |
---|---|
Axpert KING II TWIN 6.2K | 5% to 95% Relative Humidity(Non-condensing) |
Operating Temperature
Axpert KING II TWIN 6K | -10°C to 50°C |
---|---|
Axpert KING II TWIN 6.2K | -10°C to 50°C |
Storage Temperature
Axpert KING II TWIN 6K | -15°C to 60°C |
---|---|
Axpert KING II TWIN 6.2K | -15°C to 60°C |
SOLAR INPUT
Solar Charger type
Axpert KING II TWIN 6K | MPPT |
---|---|
Axpert KING II TWIN 6.2K | MPPT |
Maximum PV Array Power
Axpert KING II TWIN 6K | 6000 W |
---|---|
Axpert KING II TWIN 6.2K | 6000 W |
MPPT Range @ Operating Voltage
Axpert KING II TWIN 6K | 120 ~ 430 VDC |
---|---|
Axpert KING II TWIN 6.2K | 120 ~ 430 VDC |
Maximum PV Array Open Circuit Voltage
Axpert KING II TWIN 6K | 500 VDC |
---|---|
Axpert KING II TWIN 6.2K | 500 VDC |
Maxmum Solar Charge Current
Axpert KING II TWIN 6K | 120A |
---|---|
Axpert KING II TWIN 6.2K | 120A |
Maximum AC Charge Current
Axpert KING II TWIN 6K | 120A |
---|---|
Axpert KING II TWIN 6.2K | 120A |
![]() |
Brochure | Axpert King II TWIN |
![]() |