Axpert King II TWIN 6KVA/6.2KVA
Dual outputs for smart load management
Axpert King II TWIN is designed with zero transfer time which is perfect for critical devices such as servers and ATMs. It’s equipped with a powerful 120A solar charger and 120A AC charger. The detachable LCD control module allows users to monitor this inverter remotely. It can also expand power capacity to 54KW/55.8KW with 9 units in parallel operation. Axpert King II TWIN is occupied with two outputs. The second output can be scheduled on/off, setting cut-off voltage or SOC and discharging time via LCD setting.
Main Features
  • Dual outputs, for smart load management
  • Maximum PV input current increases to 27A
  • Zero (0ms) transfer time to protect mission-critical loads such as servers and ATMs
  • High PV input voltage range
  • Detachable LCD control module with multiple communications
  • Selectable high power charging current
  • Built-in Wi-Fi for mobile monitoring (App is available)
  • Configurable AC/Solar input priority via LCD setting
  • Reserved communication port for BMS (RS485 or CAN-BUS)
  • USB On-the-Go function
  • Parallel operation up to 9 units
General
Rated Power
Axpert KING II TWIN 6K6000VA/6000W
Axpert KING II TWIN 6.2K6200VA/6200W
Parallel Capability
Axpert KING II TWIN 6KUp to 9 units
Axpert KING II TWIN 6.2KUp to 9 units
INPUT
Voltage
Axpert KING II TWIN 6K230 VAC
Axpert KING II TWIN 6.2K230 VAC
Voltage Range
Axpert KING II TWIN 6K110-280 VAC
Axpert KING II TWIN 6.2K110-280 VAC
Frequency Range
Axpert KING II TWIN 6K50 Hz/60 Hz (Auto sensing) ± 4Hz
Axpert KING II TWIN 6.2K50 Hz/60 Hz (Auto sensing) ± 4Hz
Power Factor
Axpert KING II TWIN 6K≧ 0.98 @ Nominal Voltage (100% Load)
Axpert KING II TWIN 6.2K≧ 0.98 @ Nominal Voltage (100% Load)
THDi
Axpert KING II TWIN 6K≦ 10%
Axpert KING II TWIN 6.2K≦ 10%
OUTPUT
Frequency Range (Batt. Mode)
Axpert KING II TWIN 6K50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Axpert KING II TWIN 6.2K50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Waveform
Axpert KING II TWIN 6KPure sine wave
Axpert KING II TWIN 6.2KPure sine wave
Harmonic Distortion
Axpert KING II TWIN 6K≦3 % THD (Linear Load); ≦ 5 % THD (Non-linear Load)
Axpert KING II TWIN 6.2K≦3 % THD (Linear Load); ≦ 5 % THD (Non-linear Load)
Frequency Range (Synchronized Range)
Axpert KING II TWIN 6K46~54 Hz or 56~64 Hz
Axpert KING II TWIN 6.2K46~54 Hz or 56~64 Hz
AC Voltage Regulation (Line&Batt. Mode)
Axpert KING II TWIN 6K230VAC ± 5%
Axpert KING II TWIN 6.2K230VAC ± 5%
Transfer Time (AC Mode to Batt. Mode)
Axpert KING II TWIN 6K0ms
Axpert KING II TWIN 6.2K0ms
Transfer Time (Inverter to Bypass)
Axpert KING II TWIN 6K4 ms (Typical)
Axpert KING II TWIN 6.2K4 ms (Typical)
EFFICIENCY
Battery Mode
Axpert KING II TWIN 6K92%
Axpert KING II TWIN 6.2K92%
ECO Mode
Axpert KING II TWIN 6K98%
Axpert KING II TWIN 6.2K98%
Line Mode
Axpert KING II TWIN 6K94%
Axpert KING II TWIN 6.2K94%
BATTERY
Battery Voltage
Axpert KING II TWIN 6K40~66 VDC
Axpert KING II TWIN 6.2K40~66 VDC
Floating Charge Voltage
Axpert KING II TWIN 6K54 VDC
Axpert KING II TWIN 6.2K54 VDC
Overcharge Protection
Axpert KING II TWIN 6K66 VDC
Axpert KING II TWIN 6.2K66 VDC
PHYSICAL
Dimension, D X W X H (mm)
Axpert KING II TWIN 6K140 x 295 x 468
Axpert KING II TWIN 6.2K140 x 295 x 468
Net Weight (kgs)
Axpert KING II TWIN 6K12
Axpert KING II TWIN 6.2K12
Communication Port
Axpert KING II TWIN 6KUSB/RS232/RS485/WI-FI/Dry-contact
Axpert KING II TWIN 6.2KUSB/RS232/RS485/WI-FI/Dry-contact
OPERATING ENVIRONMENT
Operating Humidity
Axpert KING II TWIN 6K5% to 95% Relative Humidity(Non-condensing)
Axpert KING II TWIN 6.2K5% to 95% Relative Humidity(Non-condensing)
Operating Temperature
Axpert KING II TWIN 6K-10°C to 50°C
Axpert KING II TWIN 6.2K-10°C to 50°C
Storage Temperature
Axpert KING II TWIN 6K-15°C to 60°C
Axpert KING II TWIN 6.2K-15°C to 60°C
SOLAR INPUT
Solar Charger type
Axpert KING II TWIN 6KMPPT
Axpert KING II TWIN 6.2KMPPT
Maximum PV Array Power
Axpert KING II TWIN 6K6000 W
Axpert KING II TWIN 6.2K6000 W
MPPT Range @ Operating Voltage
Axpert KING II TWIN 6K120 ~ 430 VDC
Axpert KING II TWIN 6.2K120 ~ 430 VDC
Maximum PV Array Open Circuit Voltage
Axpert KING II TWIN 6K500 VDC
Axpert KING II TWIN 6.2K500 VDC
Maxmum Solar Charge Current
Axpert KING II TWIN 6K120A
Axpert KING II TWIN 6.2K120A
Maximum AC Charge Current
Axpert KING II TWIN 6K120A
Axpert KING II TWIN 6.2K120A
Brochure Axpert King II TWIN
Manual Axpert-KING II TWIN-manual-20220915
Related Products