3
Apex 400VA-2KVA
Line-Interactive UPS for computer protection
The Apex UPS is a compact and affordable "Lite" UPS designed to safeguard the power supply for personal computers. It delivers thorough protection in a small, cost-effective unit. In addition to offering enhanced protection against power surges and spikes, it supplies pure voltage through a built-in AVR stabilizer. The UPS ensures a continuous supply of clean and stable power to connected devices, while its integrated microprocessor controller ensures high reliability, making it ideal for home or small office use.
Main Features
- Available in capacities of 400VA/600VA/800VA/1KVA/1.5KVA/2KVA
- Optional touch screen LCD that cyclically displays UPS information
- Compact design
- Boost and buck AVR for voltage regulation
- Automatic restart when AC power is restored
- Charging available in off mode
- Cold start capability
- Optional generator compatibility
- Automatic shutdown when no load is detected in battery mode for models 800VA and below
- Optional USB port with HID Power Device support
| MODEL | Apex 400 | Apex 600 | Apex 800 | Apex 1K | Apex 1.5K | Apex 2K | |
| CAPACITY | 400 VA / 240 W | 600 VA / 360 W | 800 VA / 480 W | 1000 VA / 600 W | 1500 VA / 900 W | 2000 VA / 1200 W | |
| INPUT | |||||||
| Voltage | 110/120 VAC or 220/230/240 VAC | 110/120 VAC or 220/230/240 VAC | 110/120 VAC or 220/230/240 VAC | 110/120 VAC or 220/230/240 VAC | 110/120 VAC or 220/230/240 VAC | 110/120 VAC or 220/230/240 VAC | |
| Voltage Range | 81-145 VAC / 162-290 VAC | 81-145 VAC / 162-290 VAC | 81-145 VAC / 162-290 VAC | 81-145 VAC / 162-290 VAC | 81-145 VAC / 162-290 VAC | 81-145 VAC / 162-290 VAC | |
| Frequency Range | 60/50 Hz (auto sensing) | 60/50 Hz (auto sensing) | 60/50 Hz (auto sensing) | 60/50 Hz (auto sensing) | 60/50 Hz (auto sensing) | 60/50 Hz (auto sensing) | |
| OUTPUT | |||||||
| Output Voltage | 110/120 VAC or 220/230/240 VAC | 110/120 VAC or 220/230/240 VAC | 110/120 VAC or 220/230/240 VAC | 110/120 VAC or 220/230/240 VAC | 110/120 VAC or 220/230/240 VAC | 110/120 VAC or 220/230/240 VAC | |
| AC Voltage Regulation (Batt. Mode) | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
| Frequency Range (Batt. Mode) | 60 Hz or 50 Hz ±1 Hz | 60 Hz or 50 Hz ±1 Hz | 60 Hz or 50 Hz ±1 Hz | 60 Hz or 50 Hz ±1 Hz | 60 Hz or 50 Hz ±1 Hz | 60 Hz or 50 Hz ±1 Hz | |
| Transfer Time | Typical 2-6 ms | Typical 2-6 ms | Typical 2-6 ms | Typical 2-6 ms | Typical 2-6 ms | Typical 2-6 ms | |
| Waveform (Batt. Mode) | Simulated Sinewave | Simulated Sinewave | Simulated Sinewave | Simulated Sinewave | Simulated Sinewave | Simulated Sinewave | |
| BATTERY | |||||||
| Battery Type & Number | 12 V/4.5 Ah x 1 | 12 V/7 Ah x 1 | 12 V/9 Ah x 1 | 12 V/7 Ah x 2 | 12 V/9 Ah x 2 | 12 V/9 Ah x 2 | |
| Typical Charging Time | 4-6 hours recover to 90% capacity | 4-6 hours recover to 90% capacity | 4-6 hours recover to 90% capacity | 4-6 hours recover to 90% capacity | 4-6 hours recover to 90% capacity | 4-6 hours recover to 90% capacity | |
| PROTECTION | |||||||
| Full Protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection | |
| INDICATORS | |||||||
| LED Display | AC Mode | Green lighting | Green lighting | Green lighting | Green lighting | Green lighting | Green lighting |
| LED Display | Battery Mode | Green flashing | Green flashing | Green flashing | Green flashing | Yellow flashing | Yellow flashing |
| LED Display | Fault | N/A | N/A | N/A | N/A | Red lighting | Red lighting |
| LCD Model | Input voltage, output voltage, battery capacity, load level and UPS status | Input voltage, output voltage, battery capacity, load level and UPS status | Input voltage, output voltage, battery capacity, load level and UPS status | Input voltage, output voltage, battery capacity, load level and UPS status | Input voltage, output voltage, battery capacity, load level and UPS status | Input voltage, output voltage, battery capacity, load level and UPS status | |
| ALARM | |||||||
| Battery Mode | Sounding every 10 seconds | Sounding every 10 seconds | Sounding every 10 seconds | Sounding every 10 seconds | Sounding every 10 seconds | Sounding every 10 seconds | |
| Low Battery | Sounding every second | Sounding every second | Sounding every second | Sounding every second | Sounding every second | Sounding every second | |
| Overload | Sounding every 0.5 second | Sounding every 0.5 second | Sounding every 0.5 second | Sounding every 0.5 second | Sounding every 0.5 second | Sounding every 0.5 second | |
| Fault | Continuously sounding | Continuously sounding | Continuously sounding | Continuously sounding | Continuously sounding | Continuously sounding | |
| PHYSICAL | |||||||
| LCD Model | Dimension, D X W X H (mm) | 300 x 101 x 142 | 300 x 101 x 142 | 300 x 101 x 142 | 320 x 130 x 182 | 320 x 130 x 182 | 320 x 130 x 182 |
| LCD Model | Net Weight (kgs) | 3.7 | 4.4 | 5 | 7.8 | 10.4 | 10.6 |
| LED Model | Dimension, D X W X H (mm) | 279 x 101 x 142 | 279 x 101 x 142 | 279 x 101 x 142 | 320 x 130 x 182 | 320 x 130 x 182 | 320 x 130 x 182 |
| LED Model | Net Weight (kgs) | 3.55 | 4.2 | 4.9 | 8.2 | 10.4 | 11 |
| OPERATING ENVIRONMENT | |||||||
| Operating Humidity | 0-90 % RH @ 0- 40°C (non-condensing) | 0-90 % RH @ 0- 40°C (non-condensing) | 0-90 % RH @ 0- 40°C (non-condensing) | 0-90 % RH @ 0- 40°C (non-condensing) | 0-90 % RH @ 0- 40°C (non-condensing) | 0-90 % RH @ 0- 40°C (non-condensing) | |
| Noise Level | Less than 40dB | Less than 40dB | Less than 40dB | Less than 40dB | Less than 40dB | Less than 40dB | |
General
CAPACITY
| Apex 400 | 400 VA / 240 W |
|---|---|
| Apex 600 | 600 VA / 360 W |
| Apex 800 | 800 VA / 480 W |
| Apex 1K | 1000 VA / 600 W |
| Apex 1.5K | 1500 VA / 900 W |
| Apex 2K | 2000 VA / 1200 W |
INPUT
Voltage
| Apex 400 | 110/120 VAC or 220/230/240 VAC |
|---|---|
| Apex 600 | 110/120 VAC or 220/230/240 VAC |
| Apex 800 | 110/120 VAC or 220/230/240 VAC |
| Apex 1K | 110/120 VAC or 220/230/240 VAC |
| Apex 1.5K | 110/120 VAC or 220/230/240 VAC |
| Apex 2K | 110/120 VAC or 220/230/240 VAC |
Voltage Range
| Apex 400 | 81-145 VAC / 162-290 VAC |
|---|---|
| Apex 600 | 81-145 VAC / 162-290 VAC |
| Apex 800 | 81-145 VAC / 162-290 VAC |
| Apex 1K | 81-145 VAC / 162-290 VAC |
| Apex 1.5K | 81-145 VAC / 162-290 VAC |
| Apex 2K | 81-145 VAC / 162-290 VAC |
Frequency Range
| Apex 400 | 60/50 Hz (auto sensing) |
|---|---|
| Apex 600 | 60/50 Hz (auto sensing) |
| Apex 800 | 60/50 Hz (auto sensing) |
| Apex 1K | 60/50 Hz (auto sensing) |
| Apex 1.5K | 60/50 Hz (auto sensing) |
| Apex 2K | 60/50 Hz (auto sensing) |
OUTPUT
Output Voltage
| Apex 400 | 110/120 VAC or 220/230/240 VAC |
|---|---|
| Apex 600 | 110/120 VAC or 220/230/240 VAC |
| Apex 800 | 110/120 VAC or 220/230/240 VAC |
| Apex 1K | 110/120 VAC or 220/230/240 VAC |
| Apex 1.5K | 110/120 VAC or 220/230/240 VAC |
| Apex 2K | 110/120 VAC or 220/230/240 VAC |
AC Voltage Regulation (Batt. Mode)
| Apex 400 | ±10% |
|---|---|
| Apex 600 | ±10% |
| Apex 800 | ±10% |
| Apex 1K | ±10% |
| Apex 1.5K | ±10% |
| Apex 2K | ±10% |
Frequency Range (Batt. Mode)
| Apex 400 | 60 Hz or 50 Hz ±1 Hz |
|---|---|
| Apex 600 | 60 Hz or 50 Hz ±1 Hz |
| Apex 800 | 60 Hz or 50 Hz ±1 Hz |
| Apex 1K | 60 Hz or 50 Hz ±1 Hz |
| Apex 1.5K | 60 Hz or 50 Hz ±1 Hz |
| Apex 2K | 60 Hz or 50 Hz ±1 Hz |
Transfer Time
| Apex 400 | Typical 2-6 ms |
|---|---|
| Apex 600 | Typical 2-6 ms |
| Apex 800 | Typical 2-6 ms |
| Apex 1K | Typical 2-6 ms |
| Apex 1.5K | Typical 2-6 ms |
| Apex 2K | Typical 2-6 ms |
Waveform (Batt. Mode)
| Apex 400 | Simulated Sinewave |
|---|---|
| Apex 600 | Simulated Sinewave |
| Apex 800 | Simulated Sinewave |
| Apex 1K | Simulated Sinewave |
| Apex 1.5K | Simulated Sinewave |
| Apex 2K | Simulated Sinewave |
BATTERY
Battery Type & Number
| Apex 400 | 12 V/4.5 Ah x 1 |
|---|---|
| Apex 600 | 12 V/7 Ah x 1 |
| Apex 800 | 12 V/9 Ah x 1 |
| Apex 1K | 12 V/7 Ah x 2 |
| Apex 1.5K | 12 V/9 Ah x 2 |
| Apex 2K | 12 V/9 Ah x 2 |
Typical Charging Time
| Apex 400 | 4-6 hours recover to 90% capacity |
|---|---|
| Apex 600 | 4-6 hours recover to 90% capacity |
| Apex 800 | 4-6 hours recover to 90% capacity |
| Apex 1K | 4-6 hours recover to 90% capacity |
| Apex 1.5K | 4-6 hours recover to 90% capacity |
| Apex 2K | 4-6 hours recover to 90% capacity |
PROTECTION
Full Protection
| Apex 400 | Overload, discharge, and overcharge protection |
|---|---|
| Apex 600 | Overload, discharge, and overcharge protection |
| Apex 800 | Overload, discharge, and overcharge protection |
| Apex 1K | Overload, discharge, and overcharge protection |
| Apex 1.5K | Overload, discharge, and overcharge protection |
| Apex 2K | Overload, discharge, and overcharge protection |
INDICATORS
LED Display AC Mode
| Apex 400 | Green lighting |
|---|---|
| Apex 600 | Green lighting |
| Apex 800 | Green lighting |
| Apex 1K | Green lighting |
| Apex 1.5K | Green lighting |
| Apex 2K | Green lighting |
LED Display Battery Mode
| Apex 400 | Green flashing |
|---|---|
| Apex 600 | Green flashing |
| Apex 800 | Green flashing |
| Apex 1K | Green flashing |
| Apex 1.5K | Yellow flashing |
| Apex 2K | Yellow flashing |
LED Display Fault
| Apex 400 | N/A |
|---|---|
| Apex 600 | N/A |
| Apex 800 | N/A |
| Apex 1K | N/A |
| Apex 1.5K | Red lighting |
| Apex 2K | Red lighting |
LCD Model
| Apex 400 | Input voltage, output voltage, battery capacity, load level and UPS status |
|---|---|
| Apex 600 | Input voltage, output voltage, battery capacity, load level and UPS status |
| Apex 800 | Input voltage, output voltage, battery capacity, load level and UPS status |
| Apex 1K | Input voltage, output voltage, battery capacity, load level and UPS status |
| Apex 1.5K | Input voltage, output voltage, battery capacity, load level and UPS status |
| Apex 2K | Input voltage, output voltage, battery capacity, load level and UPS status |
ALARM
Battery Mode
| Apex 400 | Sounding every 10 seconds |
|---|---|
| Apex 600 | Sounding every 10 seconds |
| Apex 800 | Sounding every 10 seconds |
| Apex 1K | Sounding every 10 seconds |
| Apex 1.5K | Sounding every 10 seconds |
| Apex 2K | Sounding every 10 seconds |
Low Battery
| Apex 400 | Sounding every second |
|---|---|
| Apex 600 | Sounding every second |
| Apex 800 | Sounding every second |
| Apex 1K | Sounding every second |
| Apex 1.5K | Sounding every second |
| Apex 2K | Sounding every second |
Overload
| Apex 400 | Sounding every 0.5 second |
|---|---|
| Apex 600 | Sounding every 0.5 second |
| Apex 800 | Sounding every 0.5 second |
| Apex 1K | Sounding every 0.5 second |
| Apex 1.5K | Sounding every 0.5 second |
| Apex 2K | Sounding every 0.5 second |
Fault
| Apex 400 | Continuously sounding |
|---|---|
| Apex 600 | Continuously sounding |
| Apex 800 | Continuously sounding |
| Apex 1K | Continuously sounding |
| Apex 1.5K | Continuously sounding |
| Apex 2K | Continuously sounding |
PHYSICAL
LCD Model Dimension, D X W X H (mm)
| Apex 400 | 300 x 101 x 142 |
|---|---|
| Apex 600 | 300 x 101 x 142 |
| Apex 800 | 300 x 101 x 142 |
| Apex 1K | 320 x 130 x 182 |
| Apex 1.5K | 320 x 130 x 182 |
| Apex 2K | 320 x 130 x 182 |
LCD Model Net Weight (kgs)
| Apex 400 | 3.7 |
|---|---|
| Apex 600 | 4.4 |
| Apex 800 | 5 |
| Apex 1K | 7.8 |
| Apex 1.5K | 10.4 |
| Apex 2K | 10.6 |
LED Model Dimension, D X W X H (mm)
| Apex 400 | 279 x 101 x 142 |
|---|---|
| Apex 600 | 279 x 101 x 142 |
| Apex 800 | 279 x 101 x 142 |
| Apex 1K | 320 x 130 x 182 |
| Apex 1.5K | 320 x 130 x 182 |
| Apex 2K | 320 x 130 x 182 |
LED Model Net Weight (kgs)
| Apex 400 | 3.55 |
|---|---|
| Apex 600 | 4.2 |
| Apex 800 | 4.9 |
| Apex 1K | 8.2 |
| Apex 1.5K | 10.4 |
| Apex 2K | 11 |
OPERATING ENVIRONMENT
Operating Humidity
| Apex 400 | 0-90 % RH @ 0- 40°C (non-condensing) |
|---|---|
| Apex 600 | 0-90 % RH @ 0- 40°C (non-condensing) |
| Apex 800 | 0-90 % RH @ 0- 40°C (non-condensing) |
| Apex 1K | 0-90 % RH @ 0- 40°C (non-condensing) |
| Apex 1.5K | 0-90 % RH @ 0- 40°C (non-condensing) |
| Apex 2K | 0-90 % RH @ 0- 40°C (non-condensing) |
Noise Level
| Apex 400 | Less than 40dB |
|---|---|
| Apex 600 | Less than 40dB |
| Apex 800 | Less than 40dB |
| Apex 1K | Less than 40dB |
| Apex 1.5K | Less than 40dB |
| Apex 2K | Less than 40dB |
| Brochure | Apex_Brochure | |
| Manual | Apex 400VA-2KVA Line Interactive UPS (LCD) | |
| Manual | Apex 400VA-2KVA Line Interactive UPS (LED) |
Line Interactive UPS Apex 400VA-2KVA Line-Interactive UPS for computer protection
Related Products