42
ATS
Provides seamless power switch for IT equipment
This ATS product is designed with two independent power inlets to supply power to the load from a primary power source. Should primary power source fail, the secondary will automatically back up the connected equipment without any interruption. The transfer time from one line to another is seamless to the connected equipment. After switching to a secondary power source, the ATS can also switch power back to the primary input when power to the primary input is restored.

Main Features
- 16A, 30A max. input current
- Powered by two separately independent power sources
- Dual power supply for redundancy
- Provides seamless power switch for IT equipment
- Preferred source selection on front panel
- Highly reliability 19" rack design (1U) to fit into a diverse working environment
- Built-in USB and RS-232 communications
MODEL | ATS-16A | ATS-30A | |
TOPOLOGY | Relay | Relay+SCR | |
INPUT | |||
Input Frequency | 50 Hz/60 Hz | 50 Hz/60 Hz | |
Input Voltage | 220/230/240 VAC | 220/230/240 VAC | |
Maximum Input Current | 16 A | 30A | |
Acceptable Input Voltage Range | 180-258 VAC | 180-258 VAC | |
OUTPUT | |||
Output Voltage | 220/230/240 VAC | 220/230/240 VAC | |
Maximum Output Current | 10 A for IEC-C13 outlets, 16A for IEC-C19 outlet | 10 A for IEC-C13 outlets, 16A for IEC-C19 outlet, 30A for cable gland | |
ENVIRONMENT | |||
Operating Humidity | 0~95% RH @ -5°C- 45°C (non-condensing) | 0~95% RH @ -5°C- 45°C (non-condensing) | |
PHYSICAL | |||
Dimension, D X W X H (mm) | 330 x 430 x 44 | 330 x 430 x 44 | |
Net Weight (kgs) | 5 | 4.5 | |
Net Weight (including accessories) (kgs) | 8 | 7.5 | |
CONNECTION | |||
Communication | USB, RS-232 | USB, RS-232 | |
Input | 2 x IEC-C20 inlets | 2 x cable gland | |
Output | 8 x IEC-C13, 1 x IEC-C19 | 8 x IEC-C13, 1 x IEC-C19, 1 x cable gland | |
Transfer Time | 9-12ms (Typical), 16ms max. | 6-8ms (Typical), 10ms max. |
General
TOPOLOGY
ATS-16A | Relay |
---|---|
ATS-30A | Relay+SCR |
INPUT
Input Frequency
ATS-16A | 50 Hz/60 Hz |
---|---|
ATS-30A | 50 Hz/60 Hz |
Input Voltage
ATS-16A | 220/230/240 VAC |
---|---|
ATS-30A | 220/230/240 VAC |
Maximum Input Current
ATS-16A | 16 A |
---|---|
ATS-30A | 30A |
Acceptable Input Voltage Range
ATS-16A | 180-258 VAC |
---|---|
ATS-30A | 180-258 VAC |
OUTPUT
Output Voltage
ATS-16A | 220/230/240 VAC |
---|---|
ATS-30A | 220/230/240 VAC |
Maximum Output Current
ATS-16A | 10 A for IEC-C13 outlets, 16A for IEC-C19 outlet |
---|---|
ATS-30A | 10 A for IEC-C13 outlets, 16A for IEC-C19 outlet, 30A for cable gland |
ENVIRONMENT
Operating Humidity
ATS-16A | 0~95% RH @ -5°C- 45°C (non-condensing) |
---|---|
ATS-30A | 0~95% RH @ -5°C- 45°C (non-condensing) |
PHYSICAL
Dimension, D X W X H (mm)
ATS-16A | 330 x 430 x 44 |
---|---|
ATS-30A | 330 x 430 x 44 |
Net Weight (kgs)
ATS-16A | 5 |
---|---|
ATS-30A | 4.5 |
Net Weight (including accessories) (kgs)
ATS-16A | 8 |
---|---|
ATS-30A | 7.5 |
CONNECTION
Communication
ATS-16A | USB, RS-232 |
---|---|
ATS-30A | USB, RS-232 |
Input
ATS-16A | 2 x IEC-C20 inlets |
---|---|
ATS-30A | 2 x cable gland |
Output
ATS-16A | 8 x IEC-C13, 1 x IEC-C19 |
---|---|
ATS-30A | 8 x IEC-C13, 1 x IEC-C19, 1 x cable gland |
Transfer Time
ATS-16A | 9-12ms (Typical), 16ms max. |
---|---|
ATS-30A | 6-8ms (Typical), 10ms max. |
![]() |
Brochure | Automatic Transfer Switch (ATS)_Brochure |
![]() |
Manual | Automatic Transfer Switch (ATS)_16A_Manual |
![]() |
Manual | Automatic Transfer Switch (ATS)_30A_Manual |
Accessory ATS Provides seamless power switch for IT equipment