264
ATP 6507W/6511W/6521W
7kw-21kw AC EV charger with an IP54 protection rating
The EV charger series features Voltronic’s fully self-developed CCS controller and OCPP protocol to guarantee product reliability and minimize maintenance risks. It includes a patented ECO Energy Saving Mode that reduces power consumption. After a vehicle finishes charging, the station enters sleep mode, consuming only 12W, even if the charging nozzle remains connected. The charger will automatically resume charging when the nozzle is connected to a different vehicle. Additionally, the patented modular design of the charging module simplifies replacement and helps reduce maintenance expenses.
Main Features
- In-house developed OPCC controller
- Successfully passed stringent environmental and thermal shock tests ranging from -35°C to 55°C to guarantee system reliability
- Each charging mode features a dedicated LED status indicator for a simple and intuitive charging experience
- Incorporates the OCPP network security protocol to enable the OTA (Over-The-Air) update feature
- Passed cloud network protocol testing and received verification from OCTT
- Runs on Linux 5.10 OS and CPU that comply with cybersecurity standards
- Certified by third parties with CE EN61851, RCD EN62955, and MID EN50470 certifications
| MODEL | ATP 6507W_EU | ATP 6511W_EU | ATP 6521W_EU | ATP 6507W-US | ATP 6511W-US | ATP 6521W-US | |
| Charging Type | Charging Mode 3 Case C | Charging Mode 3 Case C | Charging Mode 3 Case C | Charging Mode 3 Case C, level 2 | Charging Mode 3 Case C, level 2 | Charging Mode 3 Case C, level 2 | |
| Connector Type | 1P + N + PE | 3P + N + PE | 3P + N + PE | L1 + L2 + PE | L1 + L2 + PE | L1 + L2 + PE | |
| Outlet Options | AC Type 2 (IEC 62196-2) | AC Type 2 (IEC 62196-2) | AC Type 2 (IEC 62196-2) | AC Type 1 (SAE J1772) | AC Type 1 (SAE J1772) | AC Type 1 (SAE J1772) | |
| Overvoltage Category | Type III | Type III | Type III | Type III | Type III | Type III | |
| Cellular Communication | GSM, 4G, LTE | GSM, 4G, LTE | GSM, 4G, LTE | GSM, 4G, LTE | GSM, 4G, LTE | GSM, 4G, LTE | |
| Input/Ouput voltage | 220-240 VAC | 380-415 VAC | 380-415 VAC | 208~240 VAC | 208~240 VAC | 208~240 VAC | |
| Input Frequency | 50 Hz or 60 Hz | 50 Hz or 60 Hz | 50 Hz or 60 Hz | 50 Hz or 60 Hz | 50 Hz or 60 Hz | 50 Hz or 60 Hz | |
| Number of EV Served | Up to 1 | Up to 1 | Up to 1 | Up to 1 | Up to 1 | Up to 1 | |
| Cable Length | 5.0 m, Optional: 7.6 m | 5.0 m, Optional: 7.6 m | 5.0 m, Optional: 7.6 m | 5.0 m, Optional: 7.6 m | 5.0 m, Optional: 7.6 m | 5.0 m, Optional: 7.6 m | |
| Distribution Systems | TT, TN , Split-phase | TT, TN , Split-phase | TT, TN , Split-phase | TT, TN | TT, TN | TT, TN | |
| Protection | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection | |
| Energy Metering | Revenue grade energy meter | Revenue grade energy meter | Revenue grade energy meter | Revenue grade energy meter | Revenue grade energy meter | Revenue grade energy meter | |
| Input/Output Current rating | 32A, single phase | 16A, three phase | 32A, three phase | 32A, single phase | 48A, single phase | 80A, single phase | |
| Input/Output Power rating | Up to 7.4 kW | Up to 11 kW | Up to 23 kW | 7.7 kW | 11.5 kW | 19.2 kW | |
| USER INTERFACE | |||||||
| RFID Reader | ISO/IEC 14443 A/B Mifare RFID reader | ISO/IEC 14443 A/B Mifare RFID reader | ISO/IEC 14443 A/B Mifare RFID reader | ISO/IEC 14443 A/B Mifare RFID reader | ISO/IEC 14443 A/B Mifare RFID reader | ISO/IEC 14443 A/B Mifare RFID reader | |
| User Authentication | RFID, QR code | RFID, QR code | RFID, QR code | RFID (Optional) | RFID (Optional) | RFID (Optional) | |
| Emergency Button | Yes | Yes | Yes | Yes | Yes | Yes | |
| Connectivity | Ethernet (RJ45), Optional: 4G / 3G or WiFi | Ethernet (RJ45), Optional: 4G / 3G or WiFi | Ethernet (RJ45), Optional: 4G / 3G or WiFi | Ethernet (RJ45), Optional: 4G / 3G or WiFi | Ethernet (RJ45), Optional: 4G / 3G or WiFi | Ethernet (RJ45), Optional: 4G / 3G or WiFi | |
| Communiation Protocols | Proprietary and OCPP 1.6J (Optional) | Proprietary and OCPP 1.6J (Optional) | Proprietary and OCPP 1.6J (Optional) | Colored indicator for status | Colored indicator for status | Colored indicator for status | |
| GENERAL CHARACTERISTICS | |||||||
| Mounting | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) | |
| Humidity | < 95%, non-condensing | < 95%, non-condensing | < 95%, non-condensing | < 95%, non-condensing | < 95%, non-condensing | < 95%, non-condensing | |
| Protection Rating | IP65 and IK10 | IP65 and IK10 | IP65 and IK10 | IP65 and IK10 | IP65 and IK10 | IP65 and IK10 | |
| Operating Temperature | -35 °C to +55 °C | -35 °C to +55 °C | -35 °C to +55 °C | -35 °C to +55 °C | -35 °C to +55 °C | -35 °C to +55 °C | |
| Net Weight (kgs) | 7 | 7 | 7 | 7 | 7 | 7 | |
| Housing Material | Standard: SGCC | Standard: SGCC | Standard: SGCC | Standard: SGCC | Standard: SGCC | Standard: SGCC | |
| Dimensions (D x W x H) mm | 110 x 282 x 407 | 110 x 282 x 407 | 110 x 282 x 407 | 110 x 282 x 407 | 110 x 282 x 407 | 110 x 282 x 407 | |
| Operational Altitude | Up to 2000 m | Up to 2000 m | Up to 2000 m | Up to 2000 m | Up to 2000 m | Up to 2000 m | |
| Starage Temperature | -40 °C to +80 °C | -40 °C to +80 °C | -40 °C to +80 °C | -40 °C to +80 °C | -40 °C to +80 °C | -40 °C to +80 °C | |
| CONFIGURATION | |||||||
| Language System | English, Chinese | English, Chinese | English, Chinese | English, Chinese | English, Chinese | English, Chinese | |
| Software Upgrade | OTA (Over the air) | OTA (Over the air) | OTA (Over the air) | OTA (Over the air) | OTA (Over the air) | OTA (Over the air) | |
| COMPLIANCE STANDARDS | |||||||
| Safety standards | IEC/EN 61851-1, EN 62311, EN 62479, IEC/EN 62955 | IEC/EN 61851-1, EN 62311, EN 62479, IEC/EN 62955 | IEC/EN 61851-1, EN 62311, EN 62479, IEC/EN 62955 | UL 2594, UL 2231-1, UL 2231-2, UL 1998, UL 991, CSA C22.2 No. 280-16, CSA C22.2 No. 281.1-12, CSA C22.2 No. 281.2-12 | UL 2594, UL 2231-1, UL 2231-2, UL 1998, UL 991, CSA C22.2 No. 280-16, CSA C22.2 No. 281.1-12, CSA C22.2 No. 281.2-12 | UL 2594, UL 2231-1, UL 2231-2, UL 1998, UL 991, CSA C22.2 No. 280-16, CSA C22.2 No. 281.1-12, CSA C22.2 No. 281.2-12 | |
| Codes and Standards | IEC 61851-21-2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, IEC 61008-1, IEC 61008-2-1, EN 62423, IEC 62196-1, IEC 62196-2 | IEC 61851-21-2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, IEC 61008-1, IEC 61008-2-1, EN 62423, IEC 62196-1, IEC 62196-2 | IEC 61851-21-2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, IEC 61008-1, IEC 61008-2-1, EN 62423, IEC 62196-1, IEC 62196-2 | IEC 60068-2-11, NEMA 3R, AC156, ISTA-3A and ISTA-3B FCC Part 15 Class B, ENERGY STAR | IEC 60068-2-11, NEMA 3R, AC156, ISTA-3A and ISTA-3B FCC Part 15 Class B, ENERGY STAR | IEC 60068-2-11, NEMA 3R, AC156, ISTA-3A and ISTA-3B FCC Part 15 Class B, ENERGY STAR | |
General
Charging Type
| ATP 6507W_EU | Charging Mode 3 Case C |
|---|---|
| ATP 6511W_EU | Charging Mode 3 Case C |
| ATP 6521W_EU | Charging Mode 3 Case C |
| ATP 6507W-US | Charging Mode 3 Case C, level 2 |
| ATP 6511W-US | Charging Mode 3 Case C, level 2 |
| ATP 6521W-US | Charging Mode 3 Case C, level 2 |
Connector Type
| ATP 6507W_EU | 1P + N + PE |
|---|---|
| ATP 6511W_EU | 3P + N + PE |
| ATP 6521W_EU | 3P + N + PE |
| ATP 6507W-US | L1 + L2 + PE |
| ATP 6511W-US | L1 + L2 + PE |
| ATP 6521W-US | L1 + L2 + PE |
Outlet Options
| ATP 6507W_EU | AC Type 2 (IEC 62196-2) |
|---|---|
| ATP 6511W_EU | AC Type 2 (IEC 62196-2) |
| ATP 6521W_EU | AC Type 2 (IEC 62196-2) |
| ATP 6507W-US | AC Type 1 (SAE J1772) |
| ATP 6511W-US | AC Type 1 (SAE J1772) |
| ATP 6521W-US | AC Type 1 (SAE J1772) |
Overvoltage Category
| ATP 6507W_EU | Type III |
|---|---|
| ATP 6511W_EU | Type III |
| ATP 6521W_EU | Type III |
| ATP 6507W-US | Type III |
| ATP 6511W-US | Type III |
| ATP 6521W-US | Type III |
Cellular Communication
| ATP 6507W_EU | GSM, 4G, LTE |
|---|---|
| ATP 6511W_EU | GSM, 4G, LTE |
| ATP 6521W_EU | GSM, 4G, LTE |
| ATP 6507W-US | GSM, 4G, LTE |
| ATP 6511W-US | GSM, 4G, LTE |
| ATP 6521W-US | GSM, 4G, LTE |
Input/Ouput voltage
| ATP 6507W_EU | 220-240 VAC |
|---|---|
| ATP 6511W_EU | 380-415 VAC |
| ATP 6521W_EU | 380-415 VAC |
| ATP 6507W-US | 208~240 VAC |
| ATP 6511W-US | 208~240 VAC |
| ATP 6521W-US | 208~240 VAC |
Input Frequency
| ATP 6507W_EU | 50 Hz or 60 Hz |
|---|---|
| ATP 6511W_EU | 50 Hz or 60 Hz |
| ATP 6521W_EU | 50 Hz or 60 Hz |
| ATP 6507W-US | 50 Hz or 60 Hz |
| ATP 6511W-US | 50 Hz or 60 Hz |
| ATP 6521W-US | 50 Hz or 60 Hz |
Number of EV Served
| ATP 6507W_EU | Up to 1 |
|---|---|
| ATP 6511W_EU | Up to 1 |
| ATP 6521W_EU | Up to 1 |
| ATP 6507W-US | Up to 1 |
| ATP 6511W-US | Up to 1 |
| ATP 6521W-US | Up to 1 |
Cable Length
| ATP 6507W_EU | 5.0 m, Optional: 7.6 m |
|---|---|
| ATP 6511W_EU | 5.0 m, Optional: 7.6 m |
| ATP 6521W_EU | 5.0 m, Optional: 7.6 m |
| ATP 6507W-US | 5.0 m, Optional: 7.6 m |
| ATP 6511W-US | 5.0 m, Optional: 7.6 m |
| ATP 6521W-US | 5.0 m, Optional: 7.6 m |
Distribution Systems
| ATP 6507W_EU | TT, TN , Split-phase |
|---|---|
| ATP 6511W_EU | TT, TN , Split-phase |
| ATP 6521W_EU | TT, TN , Split-phase |
| ATP 6507W-US | TT, TN |
| ATP 6511W-US | TT, TN |
| ATP 6521W-US | TT, TN |
Protection
| ATP 6507W_EU | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection |
|---|---|
| ATP 6511W_EU | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection |
| ATP 6521W_EU | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection |
| ATP 6507W-US | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection |
| ATP 6511W-US | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection |
| ATP 6521W-US | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection |
Energy Metering
| ATP 6507W_EU | Revenue grade energy meter |
|---|---|
| ATP 6511W_EU | Revenue grade energy meter |
| ATP 6521W_EU | Revenue grade energy meter |
| ATP 6507W-US | Revenue grade energy meter |
| ATP 6511W-US | Revenue grade energy meter |
| ATP 6521W-US | Revenue grade energy meter |
Input/Output Current rating
| ATP 6507W_EU | 32A, single phase |
|---|---|
| ATP 6511W_EU | 16A, three phase |
| ATP 6521W_EU | 32A, three phase |
| ATP 6507W-US | 32A, single phase |
| ATP 6511W-US | 48A, single phase |
| ATP 6521W-US | 80A, single phase |
Input/Output Power rating
| ATP 6507W_EU | Up to 7.4 kW |
|---|---|
| ATP 6511W_EU | Up to 11 kW |
| ATP 6521W_EU | Up to 23 kW |
| ATP 6507W-US | 7.7 kW |
| ATP 6511W-US | 11.5 kW |
| ATP 6521W-US | 19.2 kW |
USER INTERFACE
RFID Reader
| ATP 6507W_EU | ISO/IEC 14443 A/B Mifare RFID reader |
|---|---|
| ATP 6511W_EU | ISO/IEC 14443 A/B Mifare RFID reader |
| ATP 6521W_EU | ISO/IEC 14443 A/B Mifare RFID reader |
| ATP 6507W-US | ISO/IEC 14443 A/B Mifare RFID reader |
| ATP 6511W-US | ISO/IEC 14443 A/B Mifare RFID reader |
| ATP 6521W-US | ISO/IEC 14443 A/B Mifare RFID reader |
User Authentication
| ATP 6507W_EU | RFID, QR code |
|---|---|
| ATP 6511W_EU | RFID, QR code |
| ATP 6521W_EU | RFID, QR code |
| ATP 6507W-US | RFID (Optional) |
| ATP 6511W-US | RFID (Optional) |
| ATP 6521W-US | RFID (Optional) |
Emergency Button
| ATP 6507W_EU | Yes |
|---|---|
| ATP 6511W_EU | Yes |
| ATP 6521W_EU | Yes |
| ATP 6507W-US | Yes |
| ATP 6511W-US | Yes |
| ATP 6521W-US | Yes |
Connectivity
| ATP 6507W_EU | Ethernet (RJ45), Optional: 4G / 3G or WiFi |
|---|---|
| ATP 6511W_EU | Ethernet (RJ45), Optional: 4G / 3G or WiFi |
| ATP 6521W_EU | Ethernet (RJ45), Optional: 4G / 3G or WiFi |
| ATP 6507W-US | Ethernet (RJ45), Optional: 4G / 3G or WiFi |
| ATP 6511W-US | Ethernet (RJ45), Optional: 4G / 3G or WiFi |
| ATP 6521W-US | Ethernet (RJ45), Optional: 4G / 3G or WiFi |
Communiation Protocols
| ATP 6507W_EU | Proprietary and OCPP 1.6J (Optional) |
|---|---|
| ATP 6511W_EU | Proprietary and OCPP 1.6J (Optional) |
| ATP 6521W_EU | Proprietary and OCPP 1.6J (Optional) |
| ATP 6507W-US | Colored indicator for status |
| ATP 6511W-US | Colored indicator for status |
| ATP 6521W-US | Colored indicator for status |
GENERAL CHARACTERISTICS
Mounting
| ATP 6507W_EU | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) |
|---|---|
| ATP 6511W_EU | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) |
| ATP 6521W_EU | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) |
| ATP 6507W-US | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) |
| ATP 6511W-US | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) |
| ATP 6521W-US | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) |
Humidity
| ATP 6507W_EU | < 95%, non-condensing |
|---|---|
| ATP 6511W_EU | < 95%, non-condensing |
| ATP 6521W_EU | < 95%, non-condensing |
| ATP 6507W-US | < 95%, non-condensing |
| ATP 6511W-US | < 95%, non-condensing |
| ATP 6521W-US | < 95%, non-condensing |
Protection Rating
| ATP 6507W_EU | IP65 and IK10 |
|---|---|
| ATP 6511W_EU | IP65 and IK10 |
| ATP 6521W_EU | IP65 and IK10 |
| ATP 6507W-US | IP65 and IK10 |
| ATP 6511W-US | IP65 and IK10 |
| ATP 6521W-US | IP65 and IK10 |
Operating Temperature
| ATP 6507W_EU | -35 °C to +55 °C |
|---|---|
| ATP 6511W_EU | -35 °C to +55 °C |
| ATP 6521W_EU | -35 °C to +55 °C |
| ATP 6507W-US | -35 °C to +55 °C |
| ATP 6511W-US | -35 °C to +55 °C |
| ATP 6521W-US | -35 °C to +55 °C |
Net Weight (kgs)
| ATP 6507W_EU | 7 |
|---|---|
| ATP 6511W_EU | 7 |
| ATP 6521W_EU | 7 |
| ATP 6507W-US | 7 |
| ATP 6511W-US | 7 |
| ATP 6521W-US | 7 |
Housing Material
| ATP 6507W_EU | Standard: SGCC |
|---|---|
| ATP 6511W_EU | Standard: SGCC |
| ATP 6521W_EU | Standard: SGCC |
| ATP 6507W-US | Standard: SGCC |
| ATP 6511W-US | Standard: SGCC |
| ATP 6521W-US | Standard: SGCC |
Dimensions (D x W x H) mm
| ATP 6507W_EU | 110 x 282 x 407 |
|---|---|
| ATP 6511W_EU | 110 x 282 x 407 |
| ATP 6521W_EU | 110 x 282 x 407 |
| ATP 6507W-US | 110 x 282 x 407 |
| ATP 6511W-US | 110 x 282 x 407 |
| ATP 6521W-US | 110 x 282 x 407 |
Operational Altitude
| ATP 6507W_EU | Up to 2000 m |
|---|---|
| ATP 6511W_EU | Up to 2000 m |
| ATP 6521W_EU | Up to 2000 m |
| ATP 6507W-US | Up to 2000 m |
| ATP 6511W-US | Up to 2000 m |
| ATP 6521W-US | Up to 2000 m |
Starage Temperature
| ATP 6507W_EU | -40 °C to +80 °C |
|---|---|
| ATP 6511W_EU | -40 °C to +80 °C |
| ATP 6521W_EU | -40 °C to +80 °C |
| ATP 6507W-US | -40 °C to +80 °C |
| ATP 6511W-US | -40 °C to +80 °C |
| ATP 6521W-US | -40 °C to +80 °C |
CONFIGURATION
Language System
| ATP 6507W_EU | English, Chinese |
|---|---|
| ATP 6511W_EU | English, Chinese |
| ATP 6521W_EU | English, Chinese |
| ATP 6507W-US | English, Chinese |
| ATP 6511W-US | English, Chinese |
| ATP 6521W-US | English, Chinese |
Software Upgrade
| ATP 6507W_EU | OTA (Over the air) |
|---|---|
| ATP 6511W_EU | OTA (Over the air) |
| ATP 6521W_EU | OTA (Over the air) |
| ATP 6507W-US | OTA (Over the air) |
| ATP 6511W-US | OTA (Over the air) |
| ATP 6521W-US | OTA (Over the air) |
COMPLIANCE STANDARDS
Safety standards
| ATP 6507W_EU | IEC/EN 61851-1, EN 62311, EN 62479, IEC/EN 62955 |
|---|---|
| ATP 6511W_EU | IEC/EN 61851-1, EN 62311, EN 62479, IEC/EN 62955 |
| ATP 6521W_EU | IEC/EN 61851-1, EN 62311, EN 62479, IEC/EN 62955 |
| ATP 6507W-US | UL 2594, UL 2231-1, UL 2231-2, UL 1998, UL 991, CSA C22.2 No. 280-16, CSA C22.2 No. 281.1-12, CSA C22.2 No. 281.2-12 |
| ATP 6511W-US | UL 2594, UL 2231-1, UL 2231-2, UL 1998, UL 991, CSA C22.2 No. 280-16, CSA C22.2 No. 281.1-12, CSA C22.2 No. 281.2-12 |
| ATP 6521W-US | UL 2594, UL 2231-1, UL 2231-2, UL 1998, UL 991, CSA C22.2 No. 280-16, CSA C22.2 No. 281.1-12, CSA C22.2 No. 281.2-12 |
Codes and Standards
| ATP 6507W_EU | IEC 61851-21-2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, IEC 61008-1, IEC 61008-2-1, EN 62423, IEC 62196-1, IEC 62196-2 |
|---|---|
| ATP 6511W_EU | IEC 61851-21-2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, IEC 61008-1, IEC 61008-2-1, EN 62423, IEC 62196-1, IEC 62196-2 |
| ATP 6521W_EU | IEC 61851-21-2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, IEC 61008-1, IEC 61008-2-1, EN 62423, IEC 62196-1, IEC 62196-2 |
| ATP 6507W-US | IEC 60068-2-11, NEMA 3R, AC156, ISTA-3A and ISTA-3B FCC Part 15 Class B, ENERGY STAR |
| ATP 6511W-US | IEC 60068-2-11, NEMA 3R, AC156, ISTA-3A and ISTA-3B FCC Part 15 Class B, ENERGY STAR |
| ATP 6521W-US | IEC 60068-2-11, NEMA 3R, AC156, ISTA-3A and ISTA-3B FCC Part 15 Class B, ENERGY STAR |