- Select Capacity
- ATM 6507W-EU
- ATM 6511W-EU
- ATM 6521W-EU
- ATM 6507W-US
- ATM 6511W-US
- ATM 6521W-US
- Select Capacity
- ATM 6507W-EU
- ATM 6511W-EU
- ATM 6521W-EU
- ATM 6507W-US
- ATM 6511W-US
- ATM 6521W-US
254
ATM 6507W/6511W/6521W
IP65, 7kw-21kw AC EV charger
EV charger series occupied with Voltronic’s fully self-developed CCS controller and OCPP to ensure product stability and avoid maintenance risks. Patent ECO Energy Saving Mode to reduce energy consumption. Once vehicle charging is complete, the charging station will go into sleep mode (consumption 12W) even with the nozzle connected. The charging station will resume charging if the nozzle is connected to another vehicle. Moreover, the patent modularized the design of the charging module will facilitate replacement and lower maintenance costs.

Main Features
- In-house developed controllers, CCS and OCPP
- Passed rigorous environmental and thermal shock tests from -35°C to 55°to ensure the system reliability
- Each charging mode with dedicated LED status indicator light (easy and intuitive charging experience)
- Multilingual support for 4.3 colored touch LCD
- Adapting OCPP network security protocol to implement the OTA feature
- Passed cloud network protocol test and was verified by OCTT
- The Linux 5.10 OS and CPU conformed with cybersecurity standards
- Third-party certificated CE EN61851, RCD EN62955 and MID EN50470 certification
MODEL | ATM 6507W-EU | ATM 6511W-EU | ATM 6521W-EU | ATM 6507W-US | ATM 6511W-US | ATM 6521W-US | |
Charging Type | Charging Mode 3 Case C, Optional: Case B | Charging Mode 3 Case C, Optional: Case B | Charging Mode 3 Case C, Optional: Case B | Charging Mode 3 Case C, level 2 | Charging Mode 3 Case C, level 2 | Charging Mode 3 Case C, level 2 | |
Connector Type | 1P + N + PE | 3P + N + PE | 3P + N + PE | L1 + L2 + PE | L1 + L2 + PE | L1 + L2 + PE | |
Outlet Options | AC Type 2 (IEC 62196-2) | AC Type 2 (IEC 62196-2) | AC Type 2 (IEC 62196-2) | AC Type 1 (SAE J1772) | AC Type 1 (SAE J1772) | AC Type 1 (SAE J1772) | |
Overvoltage Category | Type III | Type III | Type III | Type III | Type III | Type III | |
Cellular Communication | GSM, 4G, LTE | GSM, 4G, LTE | GSM, 4G, LTE | GSM, 4G, LTE | GSM, 4G, LTE | GSM, 4G, LTE | |
Input/Ouput voltage | 220/230/240 VAC | 380/400/415 VAC | 380/400/415 VAC | 208~240 VAC | 208~240 VAC | 208~240 VAC | |
Input Frequency | 50 Hz or 60 Hz | 50 Hz or 60 Hz | 50 Hz or 60 Hz | 50 Hz or 60 Hz | 50 Hz or 60 Hz | 50 Hz or 60 Hz | |
Number of EV Served | 1 | 1 | 1 | 1 | 1 | 1 | |
Cable Length | 5.0 m, Optional: 7.6 m | 5.0 m, Optional: 7.6 m | 5.0 m, Optional: 7.6 m | 5.0 m, Optional: 7.6 m | 5.0 m, Optional: 7.6 m | 5.0 m, Optional: 7.6 m | |
Distribution Systems | TT, TN , Split-phase | TT, TN , Split-phase | TT, TN , Split-phase | TT, TN | TT, TN | TT, TN | |
Protection | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection | |
Energy Metering | Revenue grade energy meter | Revenue grade energy meter | Revenue grade energy meter | Revenue grade energy meter | Revenue grade energy meter | Revenue grade energy meter | |
Input/Output Current rating | 32A, single phase | 16A, three phase | 32A, three phase | 32A, single phase | 48A, single phase | 80A, single phase | |
Input/Output Power rating | Up to 7.4 kW | Up to 11 kW | Up to 23 kW | 7.7 kW | 11.5 kW | 19.2 kW | |
USER INTERFACE | |||||||
RFID Reader | ISO/IEC 14443 A/B Mifare RFID reader | ISO/IEC 14443 A/B Mifare RFID reader | ISO/IEC 14443 A/B Mifare RFID reader | ISO/IEC 14443 A/B Mifare RFID reader | ISO/IEC 14443 A/B Mifare RFID reader | ISO/IEC 14443 A/B Mifare RFID reader | |
User Authentication | RFID (Optional) | RFID (Optional) | RFID (Optional) | RFID (Optional) | RFID (Optional) | RFID (Optional) | |
Status Indication | 3 indicators | 3 indicators | 3 indicators | 3 indicators | 3 indicators | 3 indicators | |
Emergency Button | Yes | Yes | Yes | Yes | Yes | Yes | |
Connectivity | Ethernet (RJ45), Optional: 4G / 3G or WiFi | Ethernet (RJ45), Optional: 4G / 3G or WiFi | Ethernet (RJ45), Optional: 4G / 3G or WiFi | Ethernet (RJ45), Optional: 4G / 3G or WiFi | Ethernet (RJ45), Optional: 4G / 3G or WiFi | Ethernet (RJ45), Optional: 4G / 3G or WiFi | |
User Interface | 4.3" touchscreen LCD, Optional 5" touchscreen | 4.3" touchscreen LCD, Optional 5" touchscreen | 4.3" touchscreen LCD, Optional 5" touchscreen | 4.3" touchscreen LCD, Optional 5" touchscreen | 4.3" touchscreen LCD, Optional 5" touchscreen | 4.3" touchscreen LCD, Optional 5" touchscreen | |
Communiation Protocols | Proprietary and OCPP 1.6J (Optional) | Proprietary and OCPP 1.6J (Optional) | Proprietary and OCPP 1.6J (Optional) | Proprietary and OCPP 1.6J (Optional) | Proprietary and OCPP 1.6J (Optional) | Proprietary and OCPP 1.6J (Optional) | |
GENERAL CHARACTERISTICS | |||||||
Mounting | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) | |
Humidity | < 95%, non-condensing | < 95%, non-condensing | < 95%, non-condensing | < 95%, non-condensing | < 95%, non-condensing | < 95%, non-condensing | |
Protection Rating | IP65 and IK10 (cabinet) / IK8 (touchscreen) | IP65 and IK10 (cabinet) / IK8 (touchscreen) | IP65 and IK10 (cabinet) / IK8 (touchscreen) | IP65 and IK10 (cabinet) / IK8 (touchscreen) | IP65 and IK10 (cabinet) / IK8 (touchscreen) | IP65 and IK10 (cabinet) / IK8 (touchscreen) | |
Operating Temperature | -35 °C to +55 °C | -35 °C to +55 °C | -35 °C to +55 °C | -35 °C to +55 °C | -35 °C to +55 °C | -35 °C to +55 °C | |
Net Weight (kgs) | 12.5 | 33 | 45 | 12.5 | 33 | 45 | |
Housing Material | Standard: SGCC, Optional: SUS430 | Standard: SGCC, Optional: SUS430 | Standard: SGCC, Optional: SUS430 | Standard: SGCC, Optional: SUS430 | Standard: SGCC, Optional: SUS430 | Standard: SGCC, Optional: SUS430 | |
Dimensions (D x W x H) mm | 150 x 280 x 400 | 240 x 360 x 600 | 240 x 360 x 600 | 150 x 280 x 400 | 240 x 360 x 600 | 240 x 360 x 600 | |
Operational Altitude | Up to 2000 m | Up to 2000 m | Up to 2000 m | Up to 2000 m | Up to 2000 m | Up to 2000 m | |
Starage Temperature | -40 °C to +80 °C | -40 °C to +80 °C | -40 °C to +80 °C | -40 °C to +80 °C | -40 °C to +80 °C | -40 °C to +80 °C | |
CONFIGURATION | |||||||
Language System | English, Chinese | English, Chinese | English, Chinese | English, Chinese | English, Chinese | English, Chinese | |
Software Upgrade | OTA (Over the air) | OTA (Over the air) | OTA (Over the air) | OTA (Over the air) | OTA (Over the air) | OTA (Over the air) | |
COMPLIANCE STANDARDS | |||||||
Safety standards | IEC/EN 61851-1, EN 62311, EN 62479, IEC/EN 62955 | IEC/EN 61851-1, EN 62311, EN 62479, IEC/EN 62955 | IEC/EN 61851-1, EN 62311, EN 62479, IEC/EN 62955 | UL 2594, UL 2231-1, UL 2231-2, UL 1998, UL 991, CSA C22.2 No. 280-16, CSA C22.2 No. 281.1-12, CSA C22.2 No. 281.2-12 | UL 2594, UL 2231-1, UL 2231-2, UL 1998, UL 991, CSA C22.2 No. 280-16, CSA C22.2 No. 281.1-12, CSA C22.2 No. 281.2-12 | UL 2594, UL 2231-1, UL 2231-2, UL 1998, UL 991, CSA C22.2 No. 280-16, CSA C22.2 No. 281.1-12, CSA C22.2 No. 281.2-12 | |
Codes and Standards | IEC 61851-21-2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, IEC 61008-1, IEC 61008-2-1, EN 62423, IEC 62196-1, IEC 62196-2 | IEC 61851-21-2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, IEC 61008-1, IEC 61008-2-1, EN 62423, IEC 62196-1, IEC 62196-2 | IEC 61851-21-2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, IEC 61008-1, IEC 61008-2-1, EN 62423, IEC 62196-1, IEC 62196-2 | IEC 60068-2-11, NEMA 3R, AC156, ISTA-3A and ISTA-3B, FCC Part 15 Class B, ENERGY STAR | IEC 60068-2-11, NEMA 3R, AC156, ISTA-3A and ISTA-3B, FCC Part 15 Class B, ENERGY STAR | IEC 60068-2-11, NEMA 3R, AC156, ISTA-3A and ISTA-3B, FCC Part 15 Class B, ENERGY STAR |
General
Charging Type
ATM 6507W-EU | Charging Mode 3 Case C, Optional: Case B |
---|---|
ATM 6511W-EU | Charging Mode 3 Case C, Optional: Case B |
ATM 6521W-EU | Charging Mode 3 Case C, Optional: Case B |
ATM 6507W-US | Charging Mode 3 Case C, level 2 |
ATM 6511W-US | Charging Mode 3 Case C, level 2 |
ATM 6521W-US | Charging Mode 3 Case C, level 2 |
Connector Type
ATM 6507W-EU | 1P + N + PE |
---|---|
ATM 6511W-EU | 3P + N + PE |
ATM 6521W-EU | 3P + N + PE |
ATM 6507W-US | L1 + L2 + PE |
ATM 6511W-US | L1 + L2 + PE |
ATM 6521W-US | L1 + L2 + PE |
Outlet Options
ATM 6507W-EU | AC Type 2 (IEC 62196-2) |
---|---|
ATM 6511W-EU | AC Type 2 (IEC 62196-2) |
ATM 6521W-EU | AC Type 2 (IEC 62196-2) |
ATM 6507W-US | AC Type 1 (SAE J1772) |
ATM 6511W-US | AC Type 1 (SAE J1772) |
ATM 6521W-US | AC Type 1 (SAE J1772) |
Overvoltage Category
ATM 6507W-EU | Type III |
---|---|
ATM 6511W-EU | Type III |
ATM 6521W-EU | Type III |
ATM 6507W-US | Type III |
ATM 6511W-US | Type III |
ATM 6521W-US | Type III |
Cellular Communication
ATM 6507W-EU | GSM, 4G, LTE |
---|---|
ATM 6511W-EU | GSM, 4G, LTE |
ATM 6521W-EU | GSM, 4G, LTE |
ATM 6507W-US | GSM, 4G, LTE |
ATM 6511W-US | GSM, 4G, LTE |
ATM 6521W-US | GSM, 4G, LTE |
Input/Ouput voltage
ATM 6507W-EU | 220/230/240 VAC |
---|---|
ATM 6511W-EU | 380/400/415 VAC |
ATM 6521W-EU | 380/400/415 VAC |
ATM 6507W-US | 208~240 VAC |
ATM 6511W-US | 208~240 VAC |
ATM 6521W-US | 208~240 VAC |
Input Frequency
ATM 6507W-EU | 50 Hz or 60 Hz |
---|---|
ATM 6511W-EU | 50 Hz or 60 Hz |
ATM 6521W-EU | 50 Hz or 60 Hz |
ATM 6507W-US | 50 Hz or 60 Hz |
ATM 6511W-US | 50 Hz or 60 Hz |
ATM 6521W-US | 50 Hz or 60 Hz |
Number of EV Served
ATM 6507W-EU | 1 |
---|---|
ATM 6511W-EU | 1 |
ATM 6521W-EU | 1 |
ATM 6507W-US | 1 |
ATM 6511W-US | 1 |
ATM 6521W-US | 1 |
Cable Length
ATM 6507W-EU | 5.0 m, Optional: 7.6 m |
---|---|
ATM 6511W-EU | 5.0 m, Optional: 7.6 m |
ATM 6521W-EU | 5.0 m, Optional: 7.6 m |
ATM 6507W-US | 5.0 m, Optional: 7.6 m |
ATM 6511W-US | 5.0 m, Optional: 7.6 m |
ATM 6521W-US | 5.0 m, Optional: 7.6 m |
Distribution Systems
ATM 6507W-EU | TT, TN , Split-phase |
---|---|
ATM 6511W-EU | TT, TN , Split-phase |
ATM 6521W-EU | TT, TN , Split-phase |
ATM 6507W-US | TT, TN |
ATM 6511W-US | TT, TN |
ATM 6521W-US | TT, TN |
Protection
ATM 6507W-EU | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection |
---|---|
ATM 6511W-EU | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection |
ATM 6521W-EU | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection |
ATM 6507W-US | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection |
ATM 6511W-US | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection |
ATM 6521W-US | Overcurrent, overvoltage, undervoltage, ground fault, integrated surge protection |
Energy Metering
ATM 6507W-EU | Revenue grade energy meter |
---|---|
ATM 6511W-EU | Revenue grade energy meter |
ATM 6521W-EU | Revenue grade energy meter |
ATM 6507W-US | Revenue grade energy meter |
ATM 6511W-US | Revenue grade energy meter |
ATM 6521W-US | Revenue grade energy meter |
Input/Output Current rating
ATM 6507W-EU | 32A, single phase |
---|---|
ATM 6511W-EU | 16A, three phase |
ATM 6521W-EU | 32A, three phase |
ATM 6507W-US | 32A, single phase |
ATM 6511W-US | 48A, single phase |
ATM 6521W-US | 80A, single phase |
Input/Output Power rating
ATM 6507W-EU | Up to 7.4 kW |
---|---|
ATM 6511W-EU | Up to 11 kW |
ATM 6521W-EU | Up to 23 kW |
ATM 6507W-US | 7.7 kW |
ATM 6511W-US | 11.5 kW |
ATM 6521W-US | 19.2 kW |
USER INTERFACE
RFID Reader
ATM 6507W-EU | ISO/IEC 14443 A/B Mifare RFID reader |
---|---|
ATM 6511W-EU | ISO/IEC 14443 A/B Mifare RFID reader |
ATM 6521W-EU | ISO/IEC 14443 A/B Mifare RFID reader |
ATM 6507W-US | ISO/IEC 14443 A/B Mifare RFID reader |
ATM 6511W-US | ISO/IEC 14443 A/B Mifare RFID reader |
ATM 6521W-US | ISO/IEC 14443 A/B Mifare RFID reader |
User Authentication
ATM 6507W-EU | RFID (Optional) |
---|---|
ATM 6511W-EU | RFID (Optional) |
ATM 6521W-EU | RFID (Optional) |
ATM 6507W-US | RFID (Optional) |
ATM 6511W-US | RFID (Optional) |
ATM 6521W-US | RFID (Optional) |
Status Indication
ATM 6507W-EU | 3 indicators |
---|---|
ATM 6511W-EU | 3 indicators |
ATM 6521W-EU | 3 indicators |
ATM 6507W-US | 3 indicators |
ATM 6511W-US | 3 indicators |
ATM 6521W-US | 3 indicators |
Emergency Button
ATM 6507W-EU | Yes |
---|---|
ATM 6511W-EU | Yes |
ATM 6521W-EU | Yes |
ATM 6507W-US | Yes |
ATM 6511W-US | Yes |
ATM 6521W-US | Yes |
Connectivity
ATM 6507W-EU | Ethernet (RJ45), Optional: 4G / 3G or WiFi |
---|---|
ATM 6511W-EU | Ethernet (RJ45), Optional: 4G / 3G or WiFi |
ATM 6521W-EU | Ethernet (RJ45), Optional: 4G / 3G or WiFi |
ATM 6507W-US | Ethernet (RJ45), Optional: 4G / 3G or WiFi |
ATM 6511W-US | Ethernet (RJ45), Optional: 4G / 3G or WiFi |
ATM 6521W-US | Ethernet (RJ45), Optional: 4G / 3G or WiFi |
User Interface
ATM 6507W-EU | 4.3" touchscreen LCD, Optional 5" touchscreen |
---|---|
ATM 6511W-EU | 4.3" touchscreen LCD, Optional 5" touchscreen |
ATM 6521W-EU | 4.3" touchscreen LCD, Optional 5" touchscreen |
ATM 6507W-US | 4.3" touchscreen LCD, Optional 5" touchscreen |
ATM 6511W-US | 4.3" touchscreen LCD, Optional 5" touchscreen |
ATM 6521W-US | 4.3" touchscreen LCD, Optional 5" touchscreen |
Communiation Protocols
ATM 6507W-EU | Proprietary and OCPP 1.6J (Optional) |
---|---|
ATM 6511W-EU | Proprietary and OCPP 1.6J (Optional) |
ATM 6521W-EU | Proprietary and OCPP 1.6J (Optional) |
ATM 6507W-US | Proprietary and OCPP 1.6J (Optional) |
ATM 6511W-US | Proprietary and OCPP 1.6J (Optional) |
ATM 6521W-US | Proprietary and OCPP 1.6J (Optional) |
GENERAL CHARACTERISTICS
Mounting
ATM 6507W-EU | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) |
---|---|
ATM 6511W-EU | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) |
ATM 6521W-EU | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) |
ATM 6507W-US | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) |
ATM 6511W-US | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) |
ATM 6521W-US | Wall-mount or pedestal stand (Cable can be wrapped around the hanger) |
Humidity
ATM 6507W-EU | < 95%, non-condensing |
---|---|
ATM 6511W-EU | < 95%, non-condensing |
ATM 6521W-EU | < 95%, non-condensing |
ATM 6507W-US | < 95%, non-condensing |
ATM 6511W-US | < 95%, non-condensing |
ATM 6521W-US | < 95%, non-condensing |
Protection Rating
ATM 6507W-EU | IP65 and IK10 (cabinet) / IK8 (touchscreen) |
---|---|
ATM 6511W-EU | IP65 and IK10 (cabinet) / IK8 (touchscreen) |
ATM 6521W-EU | IP65 and IK10 (cabinet) / IK8 (touchscreen) |
ATM 6507W-US | IP65 and IK10 (cabinet) / IK8 (touchscreen) |
ATM 6511W-US | IP65 and IK10 (cabinet) / IK8 (touchscreen) |
ATM 6521W-US | IP65 and IK10 (cabinet) / IK8 (touchscreen) |
Operating Temperature
ATM 6507W-EU | -35 °C to +55 °C |
---|---|
ATM 6511W-EU | -35 °C to +55 °C |
ATM 6521W-EU | -35 °C to +55 °C |
ATM 6507W-US | -35 °C to +55 °C |
ATM 6511W-US | -35 °C to +55 °C |
ATM 6521W-US | -35 °C to +55 °C |
Net Weight (kgs)
ATM 6507W-EU | 12.5 |
---|---|
ATM 6511W-EU | 33 |
ATM 6521W-EU | 45 |
ATM 6507W-US | 12.5 |
ATM 6511W-US | 33 |
ATM 6521W-US | 45 |
Housing Material
ATM 6507W-EU | Standard: SGCC, Optional: SUS430 |
---|---|
ATM 6511W-EU | Standard: SGCC, Optional: SUS430 |
ATM 6521W-EU | Standard: SGCC, Optional: SUS430 |
ATM 6507W-US | Standard: SGCC, Optional: SUS430 |
ATM 6511W-US | Standard: SGCC, Optional: SUS430 |
ATM 6521W-US | Standard: SGCC, Optional: SUS430 |
Dimensions (D x W x H) mm
ATM 6507W-EU | 150 x 280 x 400 |
---|---|
ATM 6511W-EU | 240 x 360 x 600 |
ATM 6521W-EU | 240 x 360 x 600 |
ATM 6507W-US | 150 x 280 x 400 |
ATM 6511W-US | 240 x 360 x 600 |
ATM 6521W-US | 240 x 360 x 600 |
Operational Altitude
ATM 6507W-EU | Up to 2000 m |
---|---|
ATM 6511W-EU | Up to 2000 m |
ATM 6521W-EU | Up to 2000 m |
ATM 6507W-US | Up to 2000 m |
ATM 6511W-US | Up to 2000 m |
ATM 6521W-US | Up to 2000 m |
Starage Temperature
ATM 6507W-EU | -40 °C to +80 °C |
---|---|
ATM 6511W-EU | -40 °C to +80 °C |
ATM 6521W-EU | -40 °C to +80 °C |
ATM 6507W-US | -40 °C to +80 °C |
ATM 6511W-US | -40 °C to +80 °C |
ATM 6521W-US | -40 °C to +80 °C |
CONFIGURATION
Language System
ATM 6507W-EU | English, Chinese |
---|---|
ATM 6511W-EU | English, Chinese |
ATM 6521W-EU | English, Chinese |
ATM 6507W-US | English, Chinese |
ATM 6511W-US | English, Chinese |
ATM 6521W-US | English, Chinese |
Software Upgrade
ATM 6507W-EU | OTA (Over the air) |
---|---|
ATM 6511W-EU | OTA (Over the air) |
ATM 6521W-EU | OTA (Over the air) |
ATM 6507W-US | OTA (Over the air) |
ATM 6511W-US | OTA (Over the air) |
ATM 6521W-US | OTA (Over the air) |
COMPLIANCE STANDARDS
Safety standards
ATM 6507W-EU | IEC/EN 61851-1, EN 62311, EN 62479, IEC/EN 62955 |
---|---|
ATM 6511W-EU | IEC/EN 61851-1, EN 62311, EN 62479, IEC/EN 62955 |
ATM 6521W-EU | IEC/EN 61851-1, EN 62311, EN 62479, IEC/EN 62955 |
ATM 6507W-US | UL 2594, UL 2231-1, UL 2231-2, UL 1998, UL 991, CSA C22.2 No. 280-16, CSA C22.2 No. 281.1-12, CSA C22.2 No. 281.2-12 |
ATM 6511W-US | UL 2594, UL 2231-1, UL 2231-2, UL 1998, UL 991, CSA C22.2 No. 280-16, CSA C22.2 No. 281.1-12, CSA C22.2 No. 281.2-12 |
ATM 6521W-US | UL 2594, UL 2231-1, UL 2231-2, UL 1998, UL 991, CSA C22.2 No. 280-16, CSA C22.2 No. 281.1-12, CSA C22.2 No. 281.2-12 |
Codes and Standards
ATM 6507W-EU | IEC 61851-21-2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, IEC 61008-1, IEC 61008-2-1, EN 62423, IEC 62196-1, IEC 62196-2 |
---|---|
ATM 6511W-EU | IEC 61851-21-2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, IEC 61008-1, IEC 61008-2-1, EN 62423, IEC 62196-1, IEC 62196-2 |
ATM 6521W-EU | IEC 61851-21-2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, IEC 61008-1, IEC 61008-2-1, EN 62423, IEC 62196-1, IEC 62196-2 |
ATM 6507W-US | IEC 60068-2-11, NEMA 3R, AC156, ISTA-3A and ISTA-3B, FCC Part 15 Class B, ENERGY STAR |
ATM 6511W-US | IEC 60068-2-11, NEMA 3R, AC156, ISTA-3A and ISTA-3B, FCC Part 15 Class B, ENERGY STAR |
ATM 6521W-US | IEC 60068-2-11, NEMA 3R, AC156, ISTA-3A and ISTA-3B, FCC Part 15 Class B, ENERGY STAR |
![]() |
Brochure | ATM 6507W_ATM 6511W_ATM 6521W_DS |
![]() |
Manual | AC EV Charger_ATM 6507W_ ATM6511W_ATM6521W_user_ma |
AC EV Charger ATM 6507W/6511W/6521W IP65, 7kw-21kw AC EV charger
Related Products