APlus
The Highest Power Density 3-phase Modular Online UPS
APlus is the modular online UPS that provides high-efficiency value with a compact footprint and a flexible and scalable architecture, able to reach up to 600kW with only 10 modules. Hot-swappable modular design and built-in maintenance bypass switch enabling the system to be upgraded or repaired without powering down a mission-critical connected load.

Main Features
- 60KW single power module in 3U
- N+1 or N+X parallel redundancy for power guarantee
- Horizontal expansion by 1+1 cabinet parallel operation, up to 1.2MW
- Hot-swappable modular design decreases MTTR
- High scalability
- Built-in maintenance bypass switch for easy maintenance without interruptible
- High efficiency double conversion online UPS
- Flexible battery configuration and adjustable charging current
- High overload capability
- Power walk-in function
- Built-in dynamic password protection
- Built-in ultra communication slot
MODEL | A+ 30U-120 | A+ 30U-180 | A+ 42U-300 | A+ 42U-420 | A+ 42U-480 | A+ 42U-600 | |
CABINET CAPACITY | 120KW | 180KW | 300KW | 420KW | 480KW | 600KW | |
PHASE | 3-phase in/3-phase out | 3-phase in/3-phase out | 3-phase in/3-phase out | 3-phase in/3-phase out | 3-phase in/3-phase out | 3-phase in/3-phase out | |
BATTERY TYPE | External Battery | External Battery | External Battery | External Battery | External Battery | External Battery | |
One Power Module Capacity | 60KVA/60KW | 60KVA/60KW | 60KVA/60KW | 60KVA/60KW | 60KVA/60KW | 60KVA/60KW | |
Max. Power Module No. | 2 | 3 | 5 | 7 | 8 | 10 | |
INPUT | |||||||
Voltage Range | -30% ~ +20% | -30% ~ +20% | -30% ~ +20% | -30% ~ +20% | -30% ~ +20% | -30% ~ +20% | |
Nominal Voltage | 3 x 380/400/415 VAC (3Ph+N) | 3 x 380/400/415 VAC (3Ph+N) | 3 x 380/400/415 VAC (3Ph+N) | 3 x 380/400/415 VAC (3Ph+N) | 3 x 380/400/415 VAC (3Ph+N) | 3 x 380/400/415 VAC (3Ph+N) | |
Frequency Range | 40Hz ~70Hz | 40Hz ~70Hz | 40Hz ~70Hz | 40Hz ~70Hz | 40Hz ~70Hz | 40Hz ~70Hz | |
Nominal Frequency | 50/60Hz (Auto sensing) | 50/60Hz (Auto sensing) | 50/60Hz (Auto sensing) | 50/60Hz (Auto sensing) | 50/60Hz (Auto sensing) | 50/60Hz (Auto sensing) | |
Power Factor | > 0.99 at 100% load, >0.98 at 50% load | > 0.99 at 100% load, >0.98 at 50% load | > 0.99 at 100% load, >0.98 at 50% load | > 0.99 at 100% load, >0.98 at 50% load | > 0.99 at 100% load, >0.98 at 50% load | > 0.99 at 100% load, >0.98 at 50% load | |
Harmonic Distortion (THDi) | < 3% @ 100% load | < 3% @ 100% load | < 3% @ 100% load | < 3% @ 100% load | < 3% @ 100% load | < 3% @ 100% load | |
OUTPUT | |||||||
Nominal Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | |
Overload Capability | 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150% | 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150% | 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150% | 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150% | 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150% | 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150% | |
Voltage Regulation (Steady state) | ≦± 1% Typical (balanced load) ; ≦± 2% Typical (unbalanced load) | ≦± 1% Typical (balanced load) ; ≦± 2% Typical (unbalanced load) | ≦± 1% Typical (balanced load) ; ≦± 2% Typical (unbalanced load) | ≦± 1% Typical (balanced load) ; ≦± 2% Typical (unbalanced load) | ≦± 1% Typical (balanced load) ; ≦± 2% Typical (unbalanced load) | ≦± 1% Typical (balanced load) ; ≦± 2% Typical (unbalanced load) | |
Nominal Voltage | 3 x 380/400/415 VAC (3Ph+N) | 3 x 380/400/415 VAC (3Ph+N) | 3 x 380/400/415 VAC (3Ph+N) | 3 x 380/400/415 VAC (3Ph+N) | 3 x 380/400/415 VAC (3Ph+N) | 3 x 380/400/415 VAC (3Ph+N) | |
Efficiency | 0.96 | 0.96 | 0.96 | 0.96 | 0.96 | 0.96 | |
Harmonic Distortion | ≦2% THD (Linear Load) ; ≦4% THD (Non-linear Load) | ≦2% THD (Linear Load) ; ≦4% THD (Non-linear Load) | ≦2% THD (Linear Load) ; ≦4% THD (Non-linear Load) | ≦2% THD (Linear Load) ; ≦4% THD (Non-linear Load) | ≦2% THD (Linear Load) ; ≦4% THD (Non-linear Load) | ≦2% THD (Linear Load) ; ≦4% THD (Non-linear Load) | |
Frequency Range (Synchronized range) | 46Hz ~ 54Hz or 56Hz ~ 64Hz | 46Hz ~ 54Hz or 56Hz ~ 64Hz | 46Hz ~ 54Hz or 56Hz ~ 64Hz | 46Hz ~ 54Hz or 56Hz ~ 64Hz | 46Hz ~ 54Hz or 56Hz ~ 64Hz | 46Hz ~ 54Hz or 56Hz ~ 64Hz | |
ENVIRONMENT | |||||||
Altitude | <1000m for Nominal power | <1000m for Nominal power | <1000m for Nominal power | <1000m for Nominal power | <1000m for Nominal power | <1000m for Nominal power | |
IP Class | IP 20 | IP 20 | IP 20 | IP 20 | IP 20 | IP 20 | |
Operation Temperature | 0 ~ 40℃ | 0 ~ 40℃ | 0 ~ 40℃ | 0 ~ 40℃ | 0 ~ 40℃ | 0 ~ 40℃ | |
Relative Humidity | 0 ~ 95% non-condensing | 0 ~ 95% non-condensing | 0 ~ 95% non-condensing | 0 ~ 95% non-condensing | 0 ~ 95% non-condensing | 0 ~ 95% non-condensing | |
PHYSICAL | |||||||
Net Weight (kgs) | 308 | 352 | 516 | 654 | 932 | 1020 | |
Cabinet Dimension (D x W x H) mm | 1100 x 600 x 1475 | 1100 x 600 x 1475 | 1100 x 600 x 2010 | 1100 x 600 x 2010 | 1100 x 1200 x 2000 | 1100 x 1200 x 2000 | |
MANAGEMENT | |||||||
Optional SNMP | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | |
Smart RS-232 / USB | Supports Windows® Family, Linux and MAC | Supports Windows® Family, Linux and MAC | Supports Windows® Family, Linux and MAC | Supports Windows® Family, Linux and MAC | Supports Windows® Family, Linux and MAC | Supports Windows® Family, Linux and MAC | |
STANDARDS | |||||||
Safety | IEC/EN 62040-1 | IEC/EN 62040-1 | IEC/EN 62040-1 | IEC/EN 62040-1 | IEC/EN 62040-1 | IEC/EN 62040-1 | |
EMC | IEC/EN 62040-2 Category C3 | IEC/EN 62040-2 Category C3 | IEC/EN 62040-2 Category C3 | IEC/EN 62040-2 Category C3 | IEC/EN 62040-2 Category C3 | IEC/EN 62040-2 Category C3 | |
BATTERY / CHARGER | |||||||
Nominal Voltage | +/- 192V ~ +/- 240V (Selectable) | +/- 192V ~ +/- 240V (Selectable) | +/- 192V ~ +/- 240V (Selectable) | +/- 192V ~ +/- 240V (Selectable) | +/- 192V ~ +/- 240V (Selectable) | +/- 192V ~ +/- 240V (Selectable) | |
Maximum Voltage | +/- 240V (12V x 40 Pcs) | +/- 240V (12V x 40 Pcs) | +/- 240V (12V x 40 Pcs) | +/- 240V (12V x 40 Pcs) | +/- 240V (12V x 40 Pcs) | +/- 240V (12V x 40 Pcs) | |
Minimum Voltage | +/- 192V (12V x 32 Pcs) | +/- 192V (12V x 32 Pcs) | +/- 192V (12V x 32 Pcs) | +/- 192V (12V x 32 Pcs) | +/- 192V (12V x 32 Pcs) | +/- 192V (12V x 32 Pcs) | |
Floating Charge Voltage | 2.28V / Cell (2.25 ~2.33 Selectable) | 2.28V / Cell (2.25 ~2.33 Selectable) | 2.28V / Cell (2.25 ~2.33 Selectable) | 2.28V / Cell (2.25 ~2.33 Selectable) | 2.28V / Cell (2.25 ~2.33 Selectable) | 2.28V / Cell (2.25 ~2.33 Selectable) | |
Boost Charging Voltage | 2.35V/Cell | 2.35V/Cell | 2.35V/Cell | 2.35V/Cell | 2.35V/Cell | 2.35V/Cell | |
Temperature Compensation | Yes | Yes | Yes | Yes | Yes | Yes | |
Maximum Charging Current (Per Power Module) | 18A (Adjustable) | 18A (Adjustable) | 18A (Adjustable) | 18A (Adjustable) | 18A (Adjustable) | 18A (Adjustable) |
General
CABINET CAPACITY
A+ 30U-120 | 120KW |
---|---|
A+ 30U-180 | 180KW |
A+ 42U-300 | 300KW |
A+ 42U-420 | 420KW |
A+ 42U-480 | 480KW |
A+ 42U-600 | 600KW |
PHASE
A+ 30U-120 | 3-phase in/3-phase out |
---|---|
A+ 30U-180 | 3-phase in/3-phase out |
A+ 42U-300 | 3-phase in/3-phase out |
A+ 42U-420 | 3-phase in/3-phase out |
A+ 42U-480 | 3-phase in/3-phase out |
A+ 42U-600 | 3-phase in/3-phase out |
BATTERY TYPE
A+ 30U-120 | External Battery |
---|---|
A+ 30U-180 | External Battery |
A+ 42U-300 | External Battery |
A+ 42U-420 | External Battery |
A+ 42U-480 | External Battery |
A+ 42U-600 | External Battery |
One Power Module Capacity
A+ 30U-120 | 60KVA/60KW |
---|---|
A+ 30U-180 | 60KVA/60KW |
A+ 42U-300 | 60KVA/60KW |
A+ 42U-420 | 60KVA/60KW |
A+ 42U-480 | 60KVA/60KW |
A+ 42U-600 | 60KVA/60KW |
Max. Power Module No.
A+ 30U-120 | 2 |
---|---|
A+ 30U-180 | 3 |
A+ 42U-300 | 5 |
A+ 42U-420 | 7 |
A+ 42U-480 | 8 |
A+ 42U-600 | 10 |
INPUT
Voltage Range
A+ 30U-120 | -30% ~ +20% |
---|---|
A+ 30U-180 | -30% ~ +20% |
A+ 42U-300 | -30% ~ +20% |
A+ 42U-420 | -30% ~ +20% |
A+ 42U-480 | -30% ~ +20% |
A+ 42U-600 | -30% ~ +20% |
Nominal Voltage
A+ 30U-120 | 3 x 380/400/415 VAC (3Ph+N) |
---|---|
A+ 30U-180 | 3 x 380/400/415 VAC (3Ph+N) |
A+ 42U-300 | 3 x 380/400/415 VAC (3Ph+N) |
A+ 42U-420 | 3 x 380/400/415 VAC (3Ph+N) |
A+ 42U-480 | 3 x 380/400/415 VAC (3Ph+N) |
A+ 42U-600 | 3 x 380/400/415 VAC (3Ph+N) |
Frequency Range
A+ 30U-120 | 40Hz ~70Hz |
---|---|
A+ 30U-180 | 40Hz ~70Hz |
A+ 42U-300 | 40Hz ~70Hz |
A+ 42U-420 | 40Hz ~70Hz |
A+ 42U-480 | 40Hz ~70Hz |
A+ 42U-600 | 40Hz ~70Hz |
Nominal Frequency
A+ 30U-120 | 50/60Hz (Auto sensing) |
---|---|
A+ 30U-180 | 50/60Hz (Auto sensing) |
A+ 42U-300 | 50/60Hz (Auto sensing) |
A+ 42U-420 | 50/60Hz (Auto sensing) |
A+ 42U-480 | 50/60Hz (Auto sensing) |
A+ 42U-600 | 50/60Hz (Auto sensing) |
Power Factor
A+ 30U-120 | > 0.99 at 100% load, >0.98 at 50% load |
---|---|
A+ 30U-180 | > 0.99 at 100% load, >0.98 at 50% load |
A+ 42U-300 | > 0.99 at 100% load, >0.98 at 50% load |
A+ 42U-420 | > 0.99 at 100% load, >0.98 at 50% load |
A+ 42U-480 | > 0.99 at 100% load, >0.98 at 50% load |
A+ 42U-600 | > 0.99 at 100% load, >0.98 at 50% load |
Harmonic Distortion (THDi)
A+ 30U-120 | < 3% @ 100% load |
---|---|
A+ 30U-180 | < 3% @ 100% load |
A+ 42U-300 | < 3% @ 100% load |
A+ 42U-420 | < 3% @ 100% load |
A+ 42U-480 | < 3% @ 100% load |
A+ 42U-600 | < 3% @ 100% load |
OUTPUT
Nominal Frequency
A+ 30U-120 | 50/60Hz |
---|---|
A+ 30U-180 | 50/60Hz |
A+ 42U-300 | 50/60Hz |
A+ 42U-420 | 50/60Hz |
A+ 42U-480 | 50/60Hz |
A+ 42U-600 | 50/60Hz |
Overload Capability
A+ 30U-120 | 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150% |
---|---|
A+ 30U-180 | 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150% |
A+ 42U-300 | 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150% |
A+ 42U-420 | 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150% |
A+ 42U-480 | 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150% |
A+ 42U-600 | 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150% |
Voltage Regulation (Steady state)
A+ 30U-120 | ≦± 1% Typical (balanced load) ; ≦± 2% Typical (unbalanced load) |
---|---|
A+ 30U-180 | ≦± 1% Typical (balanced load) ; ≦± 2% Typical (unbalanced load) |
A+ 42U-300 | ≦± 1% Typical (balanced load) ; ≦± 2% Typical (unbalanced load) |
A+ 42U-420 | ≦± 1% Typical (balanced load) ; ≦± 2% Typical (unbalanced load) |
A+ 42U-480 | ≦± 1% Typical (balanced load) ; ≦± 2% Typical (unbalanced load) |
A+ 42U-600 | ≦± 1% Typical (balanced load) ; ≦± 2% Typical (unbalanced load) |
Nominal Voltage
A+ 30U-120 | 3 x 380/400/415 VAC (3Ph+N) |
---|---|
A+ 30U-180 | 3 x 380/400/415 VAC (3Ph+N) |
A+ 42U-300 | 3 x 380/400/415 VAC (3Ph+N) |
A+ 42U-420 | 3 x 380/400/415 VAC (3Ph+N) |
A+ 42U-480 | 3 x 380/400/415 VAC (3Ph+N) |
A+ 42U-600 | 3 x 380/400/415 VAC (3Ph+N) |
Efficiency
A+ 30U-120 | 0.96 |
---|---|
A+ 30U-180 | 0.96 |
A+ 42U-300 | 0.96 |
A+ 42U-420 | 0.96 |
A+ 42U-480 | 0.96 |
A+ 42U-600 | 0.96 |
Harmonic Distortion
A+ 30U-120 | ≦2% THD (Linear Load) ; ≦4% THD (Non-linear Load) |
---|---|
A+ 30U-180 | ≦2% THD (Linear Load) ; ≦4% THD (Non-linear Load) |
A+ 42U-300 | ≦2% THD (Linear Load) ; ≦4% THD (Non-linear Load) |
A+ 42U-420 | ≦2% THD (Linear Load) ; ≦4% THD (Non-linear Load) |
A+ 42U-480 | ≦2% THD (Linear Load) ; ≦4% THD (Non-linear Load) |
A+ 42U-600 | ≦2% THD (Linear Load) ; ≦4% THD (Non-linear Load) |
Frequency Range (Synchronized range)
A+ 30U-120 | 46Hz ~ 54Hz or 56Hz ~ 64Hz |
---|---|
A+ 30U-180 | 46Hz ~ 54Hz or 56Hz ~ 64Hz |
A+ 42U-300 | 46Hz ~ 54Hz or 56Hz ~ 64Hz |
A+ 42U-420 | 46Hz ~ 54Hz or 56Hz ~ 64Hz |
A+ 42U-480 | 46Hz ~ 54Hz or 56Hz ~ 64Hz |
A+ 42U-600 | 46Hz ~ 54Hz or 56Hz ~ 64Hz |
ENVIRONMENT
Altitude
A+ 30U-120 | <1000m for Nominal power |
---|---|
A+ 30U-180 | <1000m for Nominal power |
A+ 42U-300 | <1000m for Nominal power |
A+ 42U-420 | <1000m for Nominal power |
A+ 42U-480 | <1000m for Nominal power |
A+ 42U-600 | <1000m for Nominal power |
IP Class
A+ 30U-120 | IP 20 |
---|---|
A+ 30U-180 | IP 20 |
A+ 42U-300 | IP 20 |
A+ 42U-420 | IP 20 |
A+ 42U-480 | IP 20 |
A+ 42U-600 | IP 20 |
Operation Temperature
A+ 30U-120 | 0 ~ 40℃ |
---|---|
A+ 30U-180 | 0 ~ 40℃ |
A+ 42U-300 | 0 ~ 40℃ |
A+ 42U-420 | 0 ~ 40℃ |
A+ 42U-480 | 0 ~ 40℃ |
A+ 42U-600 | 0 ~ 40℃ |
Relative Humidity
A+ 30U-120 | 0 ~ 95% non-condensing |
---|---|
A+ 30U-180 | 0 ~ 95% non-condensing |
A+ 42U-300 | 0 ~ 95% non-condensing |
A+ 42U-420 | 0 ~ 95% non-condensing |
A+ 42U-480 | 0 ~ 95% non-condensing |
A+ 42U-600 | 0 ~ 95% non-condensing |
PHYSICAL
Net Weight (kgs)
A+ 30U-120 | 308 |
---|---|
A+ 30U-180 | 352 |
A+ 42U-300 | 516 |
A+ 42U-420 | 654 |
A+ 42U-480 | 932 |
A+ 42U-600 | 1020 |
Cabinet Dimension
(D x W x H) mm
A+ 30U-120 | 1100 x 600 x 1475 |
---|---|
A+ 30U-180 | 1100 x 600 x 1475 |
A+ 42U-300 | 1100 x 600 x 2010 |
A+ 42U-420 | 1100 x 600 x 2010 |
A+ 42U-480 | 1100 x 1200 x 2000 |
A+ 42U-600 | 1100 x 1200 x 2000 |
MANAGEMENT
Optional SNMP
A+ 30U-120 | Power management from SNMP manager and web browser |
---|---|
A+ 30U-180 | Power management from SNMP manager and web browser |
A+ 42U-300 | Power management from SNMP manager and web browser |
A+ 42U-420 | Power management from SNMP manager and web browser |
A+ 42U-480 | Power management from SNMP manager and web browser |
A+ 42U-600 | Power management from SNMP manager and web browser |
Smart RS-232 / USB
A+ 30U-120 | Supports Windows® Family, Linux and MAC |
---|---|
A+ 30U-180 | Supports Windows® Family, Linux and MAC |
A+ 42U-300 | Supports Windows® Family, Linux and MAC |
A+ 42U-420 | Supports Windows® Family, Linux and MAC |
A+ 42U-480 | Supports Windows® Family, Linux and MAC |
A+ 42U-600 | Supports Windows® Family, Linux and MAC |
STANDARDS
Safety
A+ 30U-120 | IEC/EN 62040-1 |
---|---|
A+ 30U-180 | IEC/EN 62040-1 |
A+ 42U-300 | IEC/EN 62040-1 |
A+ 42U-420 | IEC/EN 62040-1 |
A+ 42U-480 | IEC/EN 62040-1 |
A+ 42U-600 | IEC/EN 62040-1 |
EMC
A+ 30U-120 | IEC/EN 62040-2 Category C3 |
---|---|
A+ 30U-180 | IEC/EN 62040-2 Category C3 |
A+ 42U-300 | IEC/EN 62040-2 Category C3 |
A+ 42U-420 | IEC/EN 62040-2 Category C3 |
A+ 42U-480 | IEC/EN 62040-2 Category C3 |
A+ 42U-600 | IEC/EN 62040-2 Category C3 |
BATTERY / CHARGER
Nominal Voltage
A+ 30U-120 | +/- 192V ~ +/- 240V (Selectable) |
---|---|
A+ 30U-180 | +/- 192V ~ +/- 240V (Selectable) |
A+ 42U-300 | +/- 192V ~ +/- 240V (Selectable) |
A+ 42U-420 | +/- 192V ~ +/- 240V (Selectable) |
A+ 42U-480 | +/- 192V ~ +/- 240V (Selectable) |
A+ 42U-600 | +/- 192V ~ +/- 240V (Selectable) |
Maximum Voltage
A+ 30U-120 | +/- 240V (12V x 40 Pcs) |
---|---|
A+ 30U-180 | +/- 240V (12V x 40 Pcs) |
A+ 42U-300 | +/- 240V (12V x 40 Pcs) |
A+ 42U-420 | +/- 240V (12V x 40 Pcs) |
A+ 42U-480 | +/- 240V (12V x 40 Pcs) |
A+ 42U-600 | +/- 240V (12V x 40 Pcs) |
Minimum Voltage
A+ 30U-120 | +/- 192V (12V x 32 Pcs) |
---|---|
A+ 30U-180 | +/- 192V (12V x 32 Pcs) |
A+ 42U-300 | +/- 192V (12V x 32 Pcs) |
A+ 42U-420 | +/- 192V (12V x 32 Pcs) |
A+ 42U-480 | +/- 192V (12V x 32 Pcs) |
A+ 42U-600 | +/- 192V (12V x 32 Pcs) |
Floating Charge Voltage
A+ 30U-120 | 2.28V / Cell (2.25 ~2.33 Selectable) |
---|---|
A+ 30U-180 | 2.28V / Cell (2.25 ~2.33 Selectable) |
A+ 42U-300 | 2.28V / Cell (2.25 ~2.33 Selectable) |
A+ 42U-420 | 2.28V / Cell (2.25 ~2.33 Selectable) |
A+ 42U-480 | 2.28V / Cell (2.25 ~2.33 Selectable) |
A+ 42U-600 | 2.28V / Cell (2.25 ~2.33 Selectable) |
Boost Charging Voltage
A+ 30U-120 | 2.35V/Cell |
---|---|
A+ 30U-180 | 2.35V/Cell |
A+ 42U-300 | 2.35V/Cell |
A+ 42U-420 | 2.35V/Cell |
A+ 42U-480 | 2.35V/Cell |
A+ 42U-600 | 2.35V/Cell |
Temperature Compensation
A+ 30U-120 | Yes |
---|---|
A+ 30U-180 | Yes |
A+ 42U-300 | Yes |
A+ 42U-420 | Yes |
A+ 42U-480 | Yes |
A+ 42U-600 | Yes |
Maximum Charging Current (Per Power Module)
A+ 30U-120 | 18A (Adjustable) |
---|---|
A+ 30U-180 | 18A (Adjustable) |
A+ 42U-300 | 18A (Adjustable) |
A+ 42U-420 | 18A (Adjustable) |
A+ 42U-480 | 18A (Adjustable) |
A+ 42U-600 | 18A (Adjustable) |
![]() |