Winner Pro+ 1KVA-10KVA
The best pricing Online UPS
Winner Pro+ is the high density version of Winner Pro series of double-conversion online UPS with a output power factor 0.9. It’s designed in small cabinet with microprocessor controller. Winner Pro+ also have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relate contact cards.
Rack Tower/ Rackmount is also available for an alternative form factor and more information can be found in Downloads .


Main Features
- True double-conversion
- Microprocessor control optimizes reliability
- Input power factor correction
- Output power factor 0.9
- Wide input voltage
- Converter mode available
- ECO mode for energy saving only available for 1-3KVA models
- Adjustable battery numbers
- Generator compatible
- Smart SNMP works well with either USB or RS-232 together
- Comprehensive display allows easy monitoring and access of UPS status
MODEL | Winner Pro+ 1K | Winner Pro+ 2K | Winner Pro+ 3K | Winner Pro+ 6K | Winner Pro+ 10K | |
CAPACITY | 1000 VA / 900 W | 2000 VA / 1800 W | 3000 VA / 2700 W | 6000 VA / 5400 W | 10000 VA / 9000 W | |
PHASE | Single phase with ground | Single phase with ground | Single phase with ground | Single phase with ground | Single phase with ground | |
INPUT | ||||||
Voltage Range | 60-145 VAC or 120-300 VAC (Based on load at 50%); 90-145 VAC or 180-280 VAC (Based on load at 100%) | 60-145 VAC or 120-300 VAC (Based on load at 50%); 90-145 VAC or 180-280 VAC (Based on load at 100%) | 60-145 VAC or 120-300 VAC (Based on load at 50%); 90-145 VAC or 180-280 VAC (Based on load at 100%) | 110-300 VAC (Based on load at 50%); 176-300 VAC (Based on load at 100%) | 110-300 VAC (Based on load at 50%); 176-300 VAC (Based on load at 100%) | |
Nominal Voltage | 110/115/120/127 VAC or 200/208/220/230/240 VAC | 110/115/120/127 VAC or 200/208/220/230/240 VAC | 110/115/120/127 VAC or 200/208/220/230/240 VAC | 208/220/230/240 VAC | 208/220/230/240 VAC | |
Frequency Range | 40Hz ~70 Hz | 40Hz ~70 Hz | 40Hz ~70 Hz | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz | |
Power Factor | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | |
OUTPUT | ||||||
Voltage Regulation | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | |
Output Voltage | 110/115/120/127 VAC or 200/208/220/230/240 VAC | 110/115/120/127 VAC or 200/208/220/230/240 VAC | 110/115/120/127 VAC or 200/208/220/230/240 VAC | 208/220/230/240 VAC | 208/220/230/240 VAC | |
Frequency Range (Batt. Mode) | 50 Hz or 60 Hz ± 0.5% | 50 Hz or 60 Hz ± 0.5% | 50 Hz or 60 Hz ± 0.5% | 50 Hz or 60 Hz ± 0.1Hz | 50 Hz or 60 Hz ± 0.1Hz | |
Transfer Time | AC Mode to Battery Mode | Zero | Zero | Zero | Zero | Zero |
Transfer Time | Inverter to Bypass | 4 ms (Typical) | 4 ms (Typical) | 4 ms (Typical) | Zero | Zero |
Waveform (Batt. Mode) | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | |
Current Crest Ratio | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 | |
Harmonic Distortion | ≦ 3% THD (Linear Load); ≦ 6% THD (Non-linear Load) | ≦ 3% THD (Linear Load); ≦ 6% THD (Non-linear Load) | ≦ 3% THD (Linear Load); ≦ 6% THD (Non-linear Load) | ≦ 3% THD (Linear Load); ≦ 5% THD (Non-linear Load) | ≦ 3% THD (Linear Load); ≦ 5% THD (Non-linear Load) | |
Frequency Range (Synchronized Range) | 47~53 Hz or 57~63 Hz | 47~53 Hz or 57~63 Hz | 47~53 Hz or 57~63 Hz | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz | |
EFFICIENCY | ||||||
Battery Mode | 83% | 87% | 88% | 90% | 91% | |
AC Mode | 88% | 89% | 90% | 92% | 93% | |
BATTERY | ||||||
Long-run Model | Battery Type | Dependeing on applications | Dependeing on applications | Dependeing on applications | Dependeing on applications | Dependeing on applications |
Long-run Model | Charging Current (max.) | 1A/ 2A/ 4A/ 6A | 1A/ 2A/ 4A/ 6A | 1A/ 2A/ 4A/ 6A | 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) | 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) |
Long-run Model | Charging Voltage | 41.0 VDC ± 1% | 82.1 VDC ± 1% | 82.1 VDC ± 1% | 273 VDC ± 1% (Based on 20pcs bateries) | 273 VDC ± 1% (Based on 20pcs bateries) |
Long-run Model | Numbers | 3 | 6 | 6 | 16~20 (Adjustable) | 16~20 (Adjustable) |
Standard Model | Battery Type | 12 V / 9 AH | 12 V / 9 AH | 12 V / 9 AH | 12 V / 9 AH | 12 V / 9 AH |
Standard Model | Charging Current (max.) | 1A | 1A | 1A | 1A/2A | 1A/2A |
Standard Model | Charging Voltage | 27.4 VDC ± 1% or 41.0 VDC ± 1% | 54.7 VDC ± 1% or 82.1 VDC ± 1% | 82.1 VDC ± 1% | 218.4 VDC ± 1% or 273 VDC ± 1% | 218.4 VDC ± 1% or 273 VDC ± 1% |
Standard Model | Numbers | 2 or 3 | 4 or 6 | 6 | 16 or 20 | 16 or 20 |
Standard Model | Typical Recharge Time | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 9 hours recover to 90% capacity | 9 hours recover to 90% capacity |
INDICATORS | ||||||
LCD | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators | |
ALARM | ||||||
Battery Mode | Sounding every 4 seconds | Sounding every 4 seconds | Sounding every 4 seconds | Sounding every 4 seconds | Sounding every 4 seconds | |
Low Battery | Sounding every second | Sounding every second | Sounding every second | Sounding every second | Sounding every second | |
Overload | Sounding twice every second | Sounding twice every second | Sounding twice every second | Sounding twice every second | Sounding twice every second | |
Fault | Continuously sounding | Continuously sounding | Continuously sounding | Continuously sounding | Continuously sounding | |
ENVIRONMENT | ||||||
Operating Humidity | 20~90% RH @ 0- 40°C (non-condensing) | 20~90% RH @ 0- 40°C (non-condensing) | 20~90% RH @ 0- 40°C (non-condensing) | 0~95% RH @ 0- 50°C (non-condensing) | 0~95% RH @ 0-40°C (non-condensing) | |
Noise Level | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | Less than 55dB @ 1 Meter | Less than 58dB @ 1 Meter | |
PHYSICAL | ||||||
Standard Model | Dimension, D x W x H (mm) | 282 x 145 x 220 or 397 x 145 x 220 | 397 x 145 x 220 or 421 x 190 x 318 | 421 x 190 x 318 | 369 x 190 x 688 or 442 x 190 x 688 | 442 x 190 x 688 |
Standard Model | Net Weight (kgs) | 9.8 or 11.4 | 17 or 26.2 | 27.6 | 61 or 74 | 66 or76 |
Long-run Model | Dimension, D x W x H (mm) | 282 x 145 x 220 | 397 x 145 x 220 | 397 x 145 x 220 | 369 x 190 x 318 | 442 x 190 x 318 |
Long-run Model | Net Weight (kgs) | 4.4 | 6.8 | 7.6 | 12 | 16 |
MANAGEMENT | ||||||
Optional SNMP | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | |
Smart RS-232 / USB | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC |
General
CAPACITY
Winner Pro+ 1K | 1000 VA / 900 W |
---|---|
Winner Pro+ 2K | 2000 VA / 1800 W |
Winner Pro+ 3K | 3000 VA / 2700 W |
Winner Pro+ 6K | 6000 VA / 5400 W |
Winner Pro+ 10K | 10000 VA / 9000 W |
PHASE
Winner Pro+ 1K | Single phase with ground |
---|---|
Winner Pro+ 2K | Single phase with ground |
Winner Pro+ 3K | Single phase with ground |
Winner Pro+ 6K | Single phase with ground |
Winner Pro+ 10K | Single phase with ground |
INPUT
Voltage Range
Winner Pro+ 1K | 60-145 VAC or 120-300 VAC (Based on load at 50%); 90-145 VAC or 180-280 VAC (Based on load at 100%) |
---|---|
Winner Pro+ 2K | 60-145 VAC or 120-300 VAC (Based on load at 50%); 90-145 VAC or 180-280 VAC (Based on load at 100%) |
Winner Pro+ 3K | 60-145 VAC or 120-300 VAC (Based on load at 50%); 90-145 VAC or 180-280 VAC (Based on load at 100%) |
Winner Pro+ 6K | 110-300 VAC (Based on load at 50%); 176-300 VAC (Based on load at 100%) |
Winner Pro+ 10K | 110-300 VAC (Based on load at 50%); 176-300 VAC (Based on load at 100%) |
Nominal Voltage
Winner Pro+ 1K | 110/115/120/127 VAC or 200/208/220/230/240 VAC |
---|---|
Winner Pro+ 2K | 110/115/120/127 VAC or 200/208/220/230/240 VAC |
Winner Pro+ 3K | 110/115/120/127 VAC or 200/208/220/230/240 VAC |
Winner Pro+ 6K | 208/220/230/240 VAC |
Winner Pro+ 10K | 208/220/230/240 VAC |
Frequency Range
Winner Pro+ 1K | 40Hz ~70 Hz |
---|---|
Winner Pro+ 2K | 40Hz ~70 Hz |
Winner Pro+ 3K | 40Hz ~70 Hz |
Winner Pro+ 6K | 46~54 Hz or 56~64 Hz |
Winner Pro+ 10K | 46~54 Hz or 56~64 Hz |
Power Factor
Winner Pro+ 1K | ≧ 0.99 @ Nominal Voltage (100% load) |
---|---|
Winner Pro+ 2K | ≧ 0.99 @ Nominal Voltage (100% load) |
Winner Pro+ 3K | ≧ 0.99 @ Nominal Voltage (100% load) |
Winner Pro+ 6K | ≧ 0.99 @ Nominal Voltage (100% load) |
Winner Pro+ 10K | ≧ 0.99 @ Nominal Voltage (100% load) |
OUTPUT
Voltage Regulation
Winner Pro+ 1K | ± 1% |
---|---|
Winner Pro+ 2K | ± 1% |
Winner Pro+ 3K | ± 1% |
Winner Pro+ 6K | ± 1% |
Winner Pro+ 10K | ± 1% |
Output Voltage
Winner Pro+ 1K | 110/115/120/127 VAC or 200/208/220/230/240 VAC |
---|---|
Winner Pro+ 2K | 110/115/120/127 VAC or 200/208/220/230/240 VAC |
Winner Pro+ 3K | 110/115/120/127 VAC or 200/208/220/230/240 VAC |
Winner Pro+ 6K | 208/220/230/240 VAC |
Winner Pro+ 10K | 208/220/230/240 VAC |
Frequency Range (Batt. Mode)
Winner Pro+ 1K | 50 Hz or 60 Hz ± 0.5% |
---|---|
Winner Pro+ 2K | 50 Hz or 60 Hz ± 0.5% |
Winner Pro+ 3K | 50 Hz or 60 Hz ± 0.5% |
Winner Pro+ 6K | 50 Hz or 60 Hz ± 0.1Hz |
Winner Pro+ 10K | 50 Hz or 60 Hz ± 0.1Hz |
Transfer Time AC Mode to Battery Mode
Winner Pro+ 1K | Zero |
---|---|
Winner Pro+ 2K | Zero |
Winner Pro+ 3K | Zero |
Winner Pro+ 6K | Zero |
Winner Pro+ 10K | Zero |
Transfer Time Inverter to Bypass
Winner Pro+ 1K | 4 ms (Typical) |
---|---|
Winner Pro+ 2K | 4 ms (Typical) |
Winner Pro+ 3K | 4 ms (Typical) |
Winner Pro+ 6K | Zero |
Winner Pro+ 10K | Zero |
Waveform (Batt. Mode)
Winner Pro+ 1K | Pure Sine Wave |
---|---|
Winner Pro+ 2K | Pure Sine Wave |
Winner Pro+ 3K | Pure Sine Wave |
Winner Pro+ 6K | Pure Sine Wave |
Winner Pro+ 10K | Pure Sine Wave |
Current Crest Ratio
Winner Pro+ 1K | 3:1 |
---|---|
Winner Pro+ 2K | 3:1 |
Winner Pro+ 3K | 3:1 |
Winner Pro+ 6K | 3:1 |
Winner Pro+ 10K | 3:1 |
Harmonic Distortion
Winner Pro+ 1K | ≦ 3% THD (Linear Load); ≦ 6% THD (Non-linear Load) |
---|---|
Winner Pro+ 2K | ≦ 3% THD (Linear Load); ≦ 6% THD (Non-linear Load) |
Winner Pro+ 3K | ≦ 3% THD (Linear Load); ≦ 6% THD (Non-linear Load) |
Winner Pro+ 6K | ≦ 3% THD (Linear Load); ≦ 5% THD (Non-linear Load) |
Winner Pro+ 10K | ≦ 3% THD (Linear Load); ≦ 5% THD (Non-linear Load) |
Frequency Range (Synchronized Range)
Winner Pro+ 1K | 47~53 Hz or 57~63 Hz |
---|---|
Winner Pro+ 2K | 47~53 Hz or 57~63 Hz |
Winner Pro+ 3K | 47~53 Hz or 57~63 Hz |
Winner Pro+ 6K | 46~54 Hz or 56~64 Hz |
Winner Pro+ 10K | 46~54 Hz or 56~64 Hz |
EFFICIENCY
Battery Mode
Winner Pro+ 1K | 83% |
---|---|
Winner Pro+ 2K | 87% |
Winner Pro+ 3K | 88% |
Winner Pro+ 6K | 90% |
Winner Pro+ 10K | 91% |
AC Mode
Winner Pro+ 1K | 88% |
---|---|
Winner Pro+ 2K | 89% |
Winner Pro+ 3K | 90% |
Winner Pro+ 6K | 92% |
Winner Pro+ 10K | 93% |
BATTERY
Long-run Model Battery Type
Winner Pro+ 1K | Dependeing on applications |
---|---|
Winner Pro+ 2K | Dependeing on applications |
Winner Pro+ 3K | Dependeing on applications |
Winner Pro+ 6K | Dependeing on applications |
Winner Pro+ 10K | Dependeing on applications |
Long-run Model Charging Current (max.)
Winner Pro+ 1K | 1A/ 2A/ 4A/ 6A |
---|---|
Winner Pro+ 2K | 1A/ 2A/ 4A/ 6A |
Winner Pro+ 3K | 1A/ 2A/ 4A/ 6A |
Winner Pro+ 6K | 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) |
Winner Pro+ 10K | 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) |
Long-run Model Charging Voltage
Winner Pro+ 1K | 41.0 VDC ± 1% |
---|---|
Winner Pro+ 2K | 82.1 VDC ± 1% |
Winner Pro+ 3K | 82.1 VDC ± 1% |
Winner Pro+ 6K | 273 VDC ± 1% (Based on 20pcs bateries) |
Winner Pro+ 10K | 273 VDC ± 1% (Based on 20pcs bateries) |
Long-run Model Numbers
Winner Pro+ 1K | 3 |
---|---|
Winner Pro+ 2K | 6 |
Winner Pro+ 3K | 6 |
Winner Pro+ 6K | 16~20 (Adjustable) |
Winner Pro+ 10K | 16~20 (Adjustable) |
Standard Model Battery Type
Winner Pro+ 1K | 12 V / 9 AH |
---|---|
Winner Pro+ 2K | 12 V / 9 AH |
Winner Pro+ 3K | 12 V / 9 AH |
Winner Pro+ 6K | 12 V / 9 AH |
Winner Pro+ 10K | 12 V / 9 AH |
Standard Model Charging Current (max.)
Winner Pro+ 1K | 1A |
---|---|
Winner Pro+ 2K | 1A |
Winner Pro+ 3K | 1A |
Winner Pro+ 6K | 1A/2A |
Winner Pro+ 10K | 1A/2A |
Standard Model Charging Voltage
Winner Pro+ 1K | 27.4 VDC ± 1% or 41.0 VDC ± 1% |
---|---|
Winner Pro+ 2K | 54.7 VDC ± 1% or 82.1 VDC ± 1% |
Winner Pro+ 3K | 82.1 VDC ± 1% |
Winner Pro+ 6K | 218.4 VDC ± 1% or 273 VDC ± 1% |
Winner Pro+ 10K | 218.4 VDC ± 1% or 273 VDC ± 1% |
Standard Model Numbers
Winner Pro+ 1K | 2 or 3 |
---|---|
Winner Pro+ 2K | 4 or 6 |
Winner Pro+ 3K | 6 |
Winner Pro+ 6K | 16 or 20 |
Winner Pro+ 10K | 16 or 20 |
Standard Model Typical Recharge Time
Winner Pro+ 1K | 4 hours recover to 90% capacity |
---|---|
Winner Pro+ 2K | 4 hours recover to 90% capacity |
Winner Pro+ 3K | 4 hours recover to 90% capacity |
Winner Pro+ 6K | 9 hours recover to 90% capacity |
Winner Pro+ 10K | 9 hours recover to 90% capacity |
INDICATORS
LCD
Winner Pro+ 1K | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
---|---|
Winner Pro+ 2K | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
Winner Pro+ 3K | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
Winner Pro+ 6K | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
Winner Pro+ 10K | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
ALARM
Battery Mode
Winner Pro+ 1K | Sounding every 4 seconds |
---|---|
Winner Pro+ 2K | Sounding every 4 seconds |
Winner Pro+ 3K | Sounding every 4 seconds |
Winner Pro+ 6K | Sounding every 4 seconds |
Winner Pro+ 10K | Sounding every 4 seconds |
Low Battery
Winner Pro+ 1K | Sounding every second |
---|---|
Winner Pro+ 2K | Sounding every second |
Winner Pro+ 3K | Sounding every second |
Winner Pro+ 6K | Sounding every second |
Winner Pro+ 10K | Sounding every second |
Overload
Winner Pro+ 1K | Sounding twice every second |
---|---|
Winner Pro+ 2K | Sounding twice every second |
Winner Pro+ 3K | Sounding twice every second |
Winner Pro+ 6K | Sounding twice every second |
Winner Pro+ 10K | Sounding twice every second |
Fault
Winner Pro+ 1K | Continuously sounding |
---|---|
Winner Pro+ 2K | Continuously sounding |
Winner Pro+ 3K | Continuously sounding |
Winner Pro+ 6K | Continuously sounding |
Winner Pro+ 10K | Continuously sounding |
ENVIRONMENT
Operating Humidity
Winner Pro+ 1K | 20~90% RH @ 0- 40°C (non-condensing) |
---|---|
Winner Pro+ 2K | 20~90% RH @ 0- 40°C (non-condensing) |
Winner Pro+ 3K | 20~90% RH @ 0- 40°C (non-condensing) |
Winner Pro+ 6K | 0~95% RH @ 0- 50°C (non-condensing) |
Winner Pro+ 10K | 0~95% RH @ 0-40°C (non-condensing) |
Noise Level
Winner Pro+ 1K | Less than 50dB @ 1 Meter |
---|---|
Winner Pro+ 2K | Less than 50dB @ 1 Meter |
Winner Pro+ 3K | Less than 50dB @ 1 Meter |
Winner Pro+ 6K | Less than 55dB @ 1 Meter |
Winner Pro+ 10K | Less than 58dB @ 1 Meter |
PHYSICAL
Standard Model Dimension, D x W x H (mm)
Winner Pro+ 1K | 282 x 145 x 220 or 397 x 145 x 220 |
---|---|
Winner Pro+ 2K | 397 x 145 x 220 or 421 x 190 x 318 |
Winner Pro+ 3K | 421 x 190 x 318 |
Winner Pro+ 6K | 369 x 190 x 688 or 442 x 190 x 688 |
Winner Pro+ 10K | 442 x 190 x 688 |
Standard Model Net Weight (kgs)
Winner Pro+ 1K | 9.8 or 11.4 |
---|---|
Winner Pro+ 2K | 17 or 26.2 |
Winner Pro+ 3K | 27.6 |
Winner Pro+ 6K | 61 or 74 |
Winner Pro+ 10K | 66 or76 |
Long-run Model Dimension, D x W x H (mm)
Winner Pro+ 1K | 282 x 145 x 220 |
---|---|
Winner Pro+ 2K | 397 x 145 x 220 |
Winner Pro+ 3K | 397 x 145 x 220 |
Winner Pro+ 6K | 369 x 190 x 318 |
Winner Pro+ 10K | 442 x 190 x 318 |
Long-run Model Net Weight (kgs)
Winner Pro+ 1K | 4.4 |
---|---|
Winner Pro+ 2K | 6.8 |
Winner Pro+ 3K | 7.6 |
Winner Pro+ 6K | 12 |
Winner Pro+ 10K | 16 |
MANAGEMENT
Optional SNMP
Winner Pro+ 1K | Power management from SNMP manager and web browser |
---|---|
Winner Pro+ 2K | Power management from SNMP manager and web browser |
Winner Pro+ 3K | Power management from SNMP manager and web browser |
Winner Pro+ 6K | Power management from SNMP manager and web browser |
Winner Pro+ 10K | Power management from SNMP manager and web browser |
Smart RS-232 / USB
Winner Pro+ 1K | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC |
---|---|
Winner Pro+ 2K | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC |
Winner Pro+ 3K | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC |
Winner Pro+ 6K | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC |
Winner Pro+ 10K | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC |
![]() |
Brochure | WinnerProPlus_DS |
![]() |
Manual | Winner Pro-Plus_6-10KVA_Tower-Rack_Manual |
![]() |
Manual | WinnerProPlus-1-3K-Tower-Rack_manual |