Galleon III RT 1K-3K PF1
PF1 Online UPS with wide input voltage range
Galleon III offers a better output power factor up to 1.0, providing higher performance and efficiency for a variety of precision equipment. In comparison with our previous model of Galleon One, Galleon III has increased 3% efficiency with better performance. It is also more compact with size reduction, which saves space.


Main Features
- True double-conversion
- Microprocessor control optimizes reliability
- Input power factor correction 0.99
- Output power factor 1.0
- 50/60 Hz Frequency Converter Mode
- Wide input voltage (110 V – 300 V)
- ECO mode for energy saving
- Smart battery charger design to optimize battery performance
- Comprehensive display allows easy monitoring and access of UPS status
- SNMP/USB/RS-232 multiple communications
- Generator compatible
MODEL | Galleon III 1K-2B(L) | Galleon III 1K-3B(L) | Galleon III 1.5K(L) | Galleon III 2K-4B(L) | Galleon III 2K-6B(L) | Galleon III 3K(L) | |
CAPACITY | 1000 VA / 1000 W | 1000 VA / 1000 W | 1500 VA / 1500 W | 2000 VA / 2000 W | 2000 VA / 2000 W | 3000 VA / 3000 W | |
PHASE | Single phase with ground | Single phase with ground | Single phase with ground | Single phase with ground | Single phase with ground | Single phase with ground | |
INPUT | |||||||
Voltage Range | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) | |
Nominal Voltage | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | |
Frequency Range | 40 Hz~70 Hz | 40 Hz~70 Hz | 40 Hz~70 Hz | 40 Hz~70 Hz | 40 Hz~70 Hz | 40 Hz~70 Hz | |
Power Factor | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | |
Harmonic Distortion (THDi) | ≦ 5% @ nominal voltage (100% load) | ≦ 5% @ nominal voltage (100% load) | ≦ 5% @ nominal voltage (100% load) | ≦ 5% @ nominal voltage (100% load) | ≦ 5% @ nominal voltage (100% load) | ≦ 5% @ nominal voltage (100% load) | |
OUTPUT | |||||||
Output Voltage | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | |
AC Voltage Regulation (Batt. Mode) | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | |
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |
Transfer Time | AC Mode to Battery Mode | Zero | Zero | Zero | Zero | Zero | Zero |
Transfer Time | ECO to Battery mode | 8 ms (Typical), 10 ms(max) | 8 ms (Typical), 10 ms(max) | 8 ms (Typical), 10 ms(max) | 8 ms (Typical), 10 ms(max) | 8 ms (Typical), 10 ms(max) | 8 ms (Typical), 10 ms(max) |
Transfer Time | Inverter to Bypass | 4 ms (Typical) | 4 ms (Typical) | 4 ms (Typical) | 4 ms (Typical) | 4 ms (Typical) | 4 ms (Typical) |
Waveform (Batt. Mode) | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | |
Current Crest Ratio | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 | |
Harmonic Distortion | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) | |
Frequency Range (Synchronized Range) | 47~53 Hz or 57~63 Hz | 47~53 Hz or 57~63 Hz | 47~53 Hz or 57~63 Hz | 47~53 Hz or 57~63 Hz | 47~53 Hz or 57~63 Hz | 47~53 Hz or 57~63 Hz | |
EFFICIENCY | |||||||
Battery Mode | 96% | 96% | 97% | 97% | 97% | 97% | |
ECO Mode | 92% | 92% | 92% | 93% | 93% | 94% | |
AC Mode | 86% | 89% | 89% | 88% | 89% | 91% | |
BATTERY | |||||||
Long-run Model | Battery Type and Numbers | 12V x 2 pcs | 12V x 3 pcs | 12V x 3 pcs | 12V x 4 pcs | 12V x 6 pcs | 12V x 6 pcs |
Long-run Model | Charging Current (max.) | 8A(1A/2A/4A/6A/8A adjustable through LCD) | 8A(1A/2A/4A/6A/8A adjustable through LCD) | 8A(1A/2A/4A/6A/8A adjustable through LCD) | 8A(1A/2A/4A/6A/8A adjustable through LCD) | 8A(1A/2A/4A/6A/8A adjustable through LCD) | 8A(1A/2A/4A/6A/8A adjustable through LCD) |
Long-run Model | Charging Voltage | 27.4VDC ± 1% | 41.0 VDC ± 1% | 41.0 VDC ± 1% | 54.8VDC ± 1% | 82.2 VDC ± 1% | 82.2 VDC ± 1% |
Standard Model | Battery Type | 12 V / 9 Ah | 12 V / 7 Ah | 12 V / 9 Ah | 12 V / 9 Ah | 12 V / 7 Ah | 12 V / 9 Ah |
Standard Model | Charging Current (max.) | 1.5 A | 1.5 A | 1.5 A | 1.5 A | 1.5 A | 1.5 A |
Standard Model | Charging Voltage | 27.4VDC ± 1% | 41.0 VDC ± 1% | 41.0 VDC ± 1% | 54.8VDC ± 1% | 82.1 VDC ± 1% | 82.1 VDC ± 1% |
Standard Model | Numbers | 2 | 3 | 3 | 4 | 6 | 6 |
Standard Model | Typical Recharge Time | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity |
INDICATORS | |||||||
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | |
ENVIRONMENT | |||||||
Operating Humidity | 20~95% RH @ 0- 50°C (non-condensing) | 20~95% RH @ 0- 50°C (non-condensing) | 20~95% RH @ 0- 50°C (non-condensing) | 20~95% RH @ 0- 50°C (non-condensing) | 20~95% RH @ 0- 50°C (non-condensing) | 20~95% RH @ 0- 50°C (non-condensing) | |
Noise Level | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | |
PHYSICAL | |||||||
Standard Model | Dimension, D X W X H (mm) | 310 x 438 x 88 | 410 x 438 x 88 | 410 x 438 x 88 | 510 x 438 x 88 | 550 x 438 x 88 | 550 x 438 x 88 |
Standard Model | Net Weight (kgs) | 11 | 13.5 | 14.7 | 19 | 23 | 26.7 |
Long-run Model | Dimension, D X W X H (mm) | 310 x 438 x 88 | 310 x 438 x 88 | 310 x 438 x 88 | 310 x 438 x 88 | 310 x 438 x 88 | 310 x 438 x 88 |
Long-run Model | Net Weight (kgs) | 5.2 | 5.2 | 6.7 | 6.7 | 6.7 | 7.4 |
MANAGEMENT | |||||||
Optional external Slot (for SNMP, Dry contact, …) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | |
Smart RS-232 / USB | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | |
STANDARD | |||||||
EMC/Safety | CE (EMC: EN62040-2 C2) | CE (EMC: EN62040-2 C2) | CE (EMC: EN62040-2 C2) | CE (EMC: EN62040-2 C2) | CE (EMC: EN62040-2 C2) | CE (EMC: EN62040-2 C2) |
General
CAPACITY
Galleon III 1K-2B(L) | 1000 VA / 1000 W |
---|---|
Galleon III 1K-3B(L) | 1000 VA / 1000 W |
Galleon III 1.5K(L) | 1500 VA / 1500 W |
Galleon III 2K-4B(L) | 2000 VA / 2000 W |
Galleon III 2K-6B(L) | 2000 VA / 2000 W |
Galleon III 3K(L) | 3000 VA / 3000 W |
PHASE
Galleon III 1K-2B(L) | Single phase with ground |
---|---|
Galleon III 1K-3B(L) | Single phase with ground |
Galleon III 1.5K(L) | Single phase with ground |
Galleon III 2K-4B(L) | Single phase with ground |
Galleon III 2K-6B(L) | Single phase with ground |
Galleon III 3K(L) | Single phase with ground |
INPUT
Voltage Range
Galleon III 1K-2B(L) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) |
---|---|
Galleon III 1K-3B(L) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) |
Galleon III 1.5K(L) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) |
Galleon III 2K-4B(L) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) |
Galleon III 2K-6B(L) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) |
Galleon III 3K(L) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) |
Nominal Voltage
Galleon III 1K-2B(L) | 200*/208*/220/230/240 VAC |
---|---|
Galleon III 1K-3B(L) | 200*/208*/220/230/240 VAC |
Galleon III 1.5K(L) | 200*/208*/220/230/240 VAC |
Galleon III 2K-4B(L) | 200*/208*/220/230/240 VAC |
Galleon III 2K-6B(L) | 200*/208*/220/230/240 VAC |
Galleon III 3K(L) | 200*/208*/220/230/240 VAC |
Frequency Range
Galleon III 1K-2B(L) | 40 Hz~70 Hz |
---|---|
Galleon III 1K-3B(L) | 40 Hz~70 Hz |
Galleon III 1.5K(L) | 40 Hz~70 Hz |
Galleon III 2K-4B(L) | 40 Hz~70 Hz |
Galleon III 2K-6B(L) | 40 Hz~70 Hz |
Galleon III 3K(L) | 40 Hz~70 Hz |
Power Factor
Galleon III 1K-2B(L) | ≧ 0.99 @ Nominal Voltage (100% load) |
---|---|
Galleon III 1K-3B(L) | ≧ 0.99 @ Nominal Voltage (100% load) |
Galleon III 1.5K(L) | ≧ 0.99 @ Nominal Voltage (100% load) |
Galleon III 2K-4B(L) | ≧ 0.99 @ Nominal Voltage (100% load) |
Galleon III 2K-6B(L) | ≧ 0.99 @ Nominal Voltage (100% load) |
Galleon III 3K(L) | ≧ 0.99 @ Nominal Voltage (100% load) |
Harmonic Distortion (THDi)
Galleon III 1K-2B(L) | ≦ 5% @ nominal voltage (100% load) |
---|---|
Galleon III 1K-3B(L) | ≦ 5% @ nominal voltage (100% load) |
Galleon III 1.5K(L) | ≦ 5% @ nominal voltage (100% load) |
Galleon III 2K-4B(L) | ≦ 5% @ nominal voltage (100% load) |
Galleon III 2K-6B(L) | ≦ 5% @ nominal voltage (100% load) |
Galleon III 3K(L) | ≦ 5% @ nominal voltage (100% load) |
OUTPUT
Output Voltage
Galleon III 1K-2B(L) | 200*/208*/220/230/240 VAC |
---|---|
Galleon III 1K-3B(L) | 200*/208*/220/230/240 VAC |
Galleon III 1.5K(L) | 200*/208*/220/230/240 VAC |
Galleon III 2K-4B(L) | 200*/208*/220/230/240 VAC |
Galleon III 2K-6B(L) | 200*/208*/220/230/240 VAC |
Galleon III 3K(L) | 200*/208*/220/230/240 VAC |
AC Voltage Regulation (Batt. Mode)
Galleon III 1K-2B(L) | ± 1% |
---|---|
Galleon III 1K-3B(L) | ± 1% |
Galleon III 1.5K(L) | ± 1% |
Galleon III 2K-4B(L) | ± 1% |
Galleon III 2K-6B(L) | ± 1% |
Galleon III 3K(L) | ± 1% |
Frequency Range (Batt. Mode)
Galleon III 1K-2B(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
---|---|
Galleon III 1K-3B(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon III 1.5K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon III 2K-4B(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon III 2K-6B(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon III 3K(L) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Transfer Time AC Mode to Battery Mode
Galleon III 1K-2B(L) | Zero |
---|---|
Galleon III 1K-3B(L) | Zero |
Galleon III 1.5K(L) | Zero |
Galleon III 2K-4B(L) | Zero |
Galleon III 2K-6B(L) | Zero |
Galleon III 3K(L) | Zero |
Transfer Time ECO to Battery mode
Galleon III 1K-2B(L) | 8 ms (Typical), 10 ms(max) |
---|---|
Galleon III 1K-3B(L) | 8 ms (Typical), 10 ms(max) |
Galleon III 1.5K(L) | 8 ms (Typical), 10 ms(max) |
Galleon III 2K-4B(L) | 8 ms (Typical), 10 ms(max) |
Galleon III 2K-6B(L) | 8 ms (Typical), 10 ms(max) |
Galleon III 3K(L) | 8 ms (Typical), 10 ms(max) |
Transfer Time Inverter to Bypass
Galleon III 1K-2B(L) | 4 ms (Typical) |
---|---|
Galleon III 1K-3B(L) | 4 ms (Typical) |
Galleon III 1.5K(L) | 4 ms (Typical) |
Galleon III 2K-4B(L) | 4 ms (Typical) |
Galleon III 2K-6B(L) | 4 ms (Typical) |
Galleon III 3K(L) | 4 ms (Typical) |
Waveform (Batt. Mode)
Galleon III 1K-2B(L) | Pure Sine Wave |
---|---|
Galleon III 1K-3B(L) | Pure Sine Wave |
Galleon III 1.5K(L) | Pure Sine Wave |
Galleon III 2K-4B(L) | Pure Sine Wave |
Galleon III 2K-6B(L) | Pure Sine Wave |
Galleon III 3K(L) | Pure Sine Wave |
Current Crest Ratio
Galleon III 1K-2B(L) | 3:1 |
---|---|
Galleon III 1K-3B(L) | 3:1 |
Galleon III 1.5K(L) | 3:1 |
Galleon III 2K-4B(L) | 3:1 |
Galleon III 2K-6B(L) | 3:1 |
Galleon III 3K(L) | 3:1 |
Harmonic Distortion
Galleon III 1K-2B(L) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) |
---|---|
Galleon III 1K-3B(L) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) |
Galleon III 1.5K(L) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) |
Galleon III 2K-4B(L) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) |
Galleon III 2K-6B(L) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) |
Galleon III 3K(L) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) |
Frequency Range (Synchronized Range)
Galleon III 1K-2B(L) | 47~53 Hz or 57~63 Hz |
---|---|
Galleon III 1K-3B(L) | 47~53 Hz or 57~63 Hz |
Galleon III 1.5K(L) | 47~53 Hz or 57~63 Hz |
Galleon III 2K-4B(L) | 47~53 Hz or 57~63 Hz |
Galleon III 2K-6B(L) | 47~53 Hz or 57~63 Hz |
Galleon III 3K(L) | 47~53 Hz or 57~63 Hz |
EFFICIENCY
Battery Mode
Galleon III 1K-2B(L) | 96% |
---|---|
Galleon III 1K-3B(L) | 96% |
Galleon III 1.5K(L) | 97% |
Galleon III 2K-4B(L) | 97% |
Galleon III 2K-6B(L) | 97% |
Galleon III 3K(L) | 97% |
ECO Mode
Galleon III 1K-2B(L) | 92% |
---|---|
Galleon III 1K-3B(L) | 92% |
Galleon III 1.5K(L) | 92% |
Galleon III 2K-4B(L) | 93% |
Galleon III 2K-6B(L) | 93% |
Galleon III 3K(L) | 94% |
AC Mode
Galleon III 1K-2B(L) | 86% |
---|---|
Galleon III 1K-3B(L) | 89% |
Galleon III 1.5K(L) | 89% |
Galleon III 2K-4B(L) | 88% |
Galleon III 2K-6B(L) | 89% |
Galleon III 3K(L) | 91% |
BATTERY
Long-run Model Battery Type and Numbers
Galleon III 1K-2B(L) | 12V x 2 pcs |
---|---|
Galleon III 1K-3B(L) | 12V x 3 pcs |
Galleon III 1.5K(L) | 12V x 3 pcs |
Galleon III 2K-4B(L) | 12V x 4 pcs |
Galleon III 2K-6B(L) | 12V x 6 pcs |
Galleon III 3K(L) | 12V x 6 pcs |
Long-run Model Charging Current (max.)
Galleon III 1K-2B(L) | 8A(1A/2A/4A/6A/8A adjustable through LCD) |
---|---|
Galleon III 1K-3B(L) | 8A(1A/2A/4A/6A/8A adjustable through LCD) |
Galleon III 1.5K(L) | 8A(1A/2A/4A/6A/8A adjustable through LCD) |
Galleon III 2K-4B(L) | 8A(1A/2A/4A/6A/8A adjustable through LCD) |
Galleon III 2K-6B(L) | 8A(1A/2A/4A/6A/8A adjustable through LCD) |
Galleon III 3K(L) | 8A(1A/2A/4A/6A/8A adjustable through LCD) |
Long-run Model Charging Voltage
Galleon III 1K-2B(L) | 27.4VDC ± 1% |
---|---|
Galleon III 1K-3B(L) | 41.0 VDC ± 1% |
Galleon III 1.5K(L) | 41.0 VDC ± 1% |
Galleon III 2K-4B(L) | 54.8VDC ± 1% |
Galleon III 2K-6B(L) | 82.2 VDC ± 1% |
Galleon III 3K(L) | 82.2 VDC ± 1% |
Standard Model Battery Type
Galleon III 1K-2B(L) | 12 V / 9 Ah |
---|---|
Galleon III 1K-3B(L) | 12 V / 7 Ah |
Galleon III 1.5K(L) | 12 V / 9 Ah |
Galleon III 2K-4B(L) | 12 V / 9 Ah |
Galleon III 2K-6B(L) | 12 V / 7 Ah |
Galleon III 3K(L) | 12 V / 9 Ah |
Standard Model Charging Current (max.)
Galleon III 1K-2B(L) | 1.5 A |
---|---|
Galleon III 1K-3B(L) | 1.5 A |
Galleon III 1.5K(L) | 1.5 A |
Galleon III 2K-4B(L) | 1.5 A |
Galleon III 2K-6B(L) | 1.5 A |
Galleon III 3K(L) | 1.5 A |
Standard Model Charging Voltage
Galleon III 1K-2B(L) | 27.4VDC ± 1% |
---|---|
Galleon III 1K-3B(L) | 41.0 VDC ± 1% |
Galleon III 1.5K(L) | 41.0 VDC ± 1% |
Galleon III 2K-4B(L) | 54.8VDC ± 1% |
Galleon III 2K-6B(L) | 82.1 VDC ± 1% |
Galleon III 3K(L) | 82.1 VDC ± 1% |
Standard Model Numbers
Galleon III 1K-2B(L) | 2 |
---|---|
Galleon III 1K-3B(L) | 3 |
Galleon III 1.5K(L) | 3 |
Galleon III 2K-4B(L) | 4 |
Galleon III 2K-6B(L) | 6 |
Galleon III 3K(L) | 6 |
Standard Model Typical Recharge Time
Galleon III 1K-2B(L) | 4 hours recover to 90% capacity |
---|---|
Galleon III 1K-3B(L) | 4 hours recover to 90% capacity |
Galleon III 1.5K(L) | 4 hours recover to 90% capacity |
Galleon III 2K-4B(L) | 4 hours recover to 90% capacity |
Galleon III 2K-6B(L) | 4 hours recover to 90% capacity |
Galleon III 3K(L) | 4 hours recover to 90% capacity |
INDICATORS
LCD Panel
Galleon III 1K-2B(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
---|---|
Galleon III 1K-3B(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon III 1.5K(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon III 2K-4B(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon III 2K-6B(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon III 3K(L) | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
ENVIRONMENT
Operating Humidity
Galleon III 1K-2B(L) | 20~95% RH @ 0- 50°C (non-condensing) |
---|---|
Galleon III 1K-3B(L) | 20~95% RH @ 0- 50°C (non-condensing) |
Galleon III 1.5K(L) | 20~95% RH @ 0- 50°C (non-condensing) |
Galleon III 2K-4B(L) | 20~95% RH @ 0- 50°C (non-condensing) |
Galleon III 2K-6B(L) | 20~95% RH @ 0- 50°C (non-condensing) |
Galleon III 3K(L) | 20~95% RH @ 0- 50°C (non-condensing) |
Noise Level
Galleon III 1K-2B(L) | Less than 50dB @ 1 Meter |
---|---|
Galleon III 1K-3B(L) | Less than 50dB @ 1 Meter |
Galleon III 1.5K(L) | Less than 50dB @ 1 Meter |
Galleon III 2K-4B(L) | Less than 50dB @ 1 Meter |
Galleon III 2K-6B(L) | Less than 50dB @ 1 Meter |
Galleon III 3K(L) | Less than 50dB @ 1 Meter |
PHYSICAL
Standard Model Dimension, D X W X H (mm)
Galleon III 1K-2B(L) | 310 x 438 x 88 |
---|---|
Galleon III 1K-3B(L) | 410 x 438 x 88 |
Galleon III 1.5K(L) | 410 x 438 x 88 |
Galleon III 2K-4B(L) | 510 x 438 x 88 |
Galleon III 2K-6B(L) | 550 x 438 x 88 |
Galleon III 3K(L) | 550 x 438 x 88 |
Standard Model Net Weight (kgs)
Galleon III 1K-2B(L) | 11 |
---|---|
Galleon III 1K-3B(L) | 13.5 |
Galleon III 1.5K(L) | 14.7 |
Galleon III 2K-4B(L) | 19 |
Galleon III 2K-6B(L) | 23 |
Galleon III 3K(L) | 26.7 |
Long-run Model Dimension, D X W X H (mm)
Galleon III 1K-2B(L) | 310 x 438 x 88 |
---|---|
Galleon III 1K-3B(L) | 310 x 438 x 88 |
Galleon III 1.5K(L) | 310 x 438 x 88 |
Galleon III 2K-4B(L) | 310 x 438 x 88 |
Galleon III 2K-6B(L) | 310 x 438 x 88 |
Galleon III 3K(L) | 310 x 438 x 88 |
Long-run Model Net Weight (kgs)
Galleon III 1K-2B(L) | 5.2 |
---|---|
Galleon III 1K-3B(L) | 5.2 |
Galleon III 1.5K(L) | 6.7 |
Galleon III 2K-4B(L) | 6.7 |
Galleon III 2K-6B(L) | 6.7 |
Galleon III 3K(L) | 7.4 |
MANAGEMENT
Optional external Slot (for SNMP, Dry contact, …)
Galleon III 1K-2B(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
---|---|
Galleon III 1K-3B(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon III 1.5K(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon III 2K-4B(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon III 2K-6B(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon III 3K(L) | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Smart RS-232 / USB
Galleon III 1K-2B(L) | Power management from SNMP manager and web browser |
---|---|
Galleon III 1K-3B(L) | Power management from SNMP manager and web browser |
Galleon III 1.5K(L) | Power management from SNMP manager and web browser |
Galleon III 2K-4B(L) | Power management from SNMP manager and web browser |
Galleon III 2K-6B(L) | Power management from SNMP manager and web browser |
Galleon III 3K(L) | Power management from SNMP manager and web browser |
STANDARD
EMC/Safety
Galleon III 1K-2B(L) | CE (EMC: EN62040-2 C2) |
---|---|
Galleon III 1K-3B(L) | CE (EMC: EN62040-2 C2) |
Galleon III 1.5K(L) | CE (EMC: EN62040-2 C2) |
Galleon III 2K-4B(L) | CE (EMC: EN62040-2 C2) |
Galleon III 2K-6B(L) | CE (EMC: EN62040-2 C2) |
Galleon III 3K(L) | CE (EMC: EN62040-2 C2) |
![]() |
Brochure | Galleon III-TOWER-RT-1-3K manual |
![]() |
Brochure | Galleon_III-1K-3K_Rack(PF1) |
Single phase - Online UPS Galleon III RT 1K-3K PF1 PF1 Online UPS with wide input voltage range