Galleon III 1K-3K PF1
PF1 Online UPS with wide input voltage range
Galleon III offers a better output power factor up to 1.0, providing higher performance and efficiency for a variety of precision equipment. In comparison with our previous model of Galleon One, Galleon III has increased 3% efficiency with better performance. It is also more compact with size reduction, which saves space.


Main Features
- True double-conversion
- Microprocessor control optimizes reliability
- Input power factor correction 0.99
- Output power factor 1.0
- 50/60 Hz Frequency Converter Mode
- Wide input voltage (110 V – 300 V)
- ECO mode for energy saving
- Smart battery charger design to optimize battery performance
- Comprehensive display allows easy monitoring and access of UPS status
- SNMP/USB/RS-232 multiple communications
- Generator compatible
MODEL | Galleon III 1K-2B | Galleon III 1K-3B | Galleon III 1.5K | Galleon III 2K-4B | Galleon III 2K-6B | Galleon III 3K | |
CAPACITY | 1000 VA / 1000 W | 1000 VA / 1000 W | 1500 VA / 1500 W | 2000 VA / 2000 W | 2000 VA / 2000 W | 3000 VA / 3000 W | |
PHASE | Single phase with ground | Single phase with ground | Single phase with ground | Single phase with ground | Single phase with ground | Single phase with ground | |
INPUT | |||||||
Voltage Range | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) | |
Nominal Voltage | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | |
Frequency Range | 40 Hz~70 Hz | 40 Hz~70 Hz | 40 Hz~70 Hz | 40 Hz~70 Hz | 40 Hz~70 Hz | 40 Hz~70 Hz | |
Power Factor | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | |
Harmonic Distortion (THDi) | ≦ 5% @ nominal voltage (100% load) | ≦ 5% @ nominal voltage (100% load) | ≦ 5% @ nominal voltage (100% load) | ≦ 5% @ nominal voltage (100% load) | ≦ 5% @ nominal voltage (100% load) | ≦ 5% @ nominal voltage (100% load) | |
OUTPUT | |||||||
Output Voltage | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | 200*/208*/220/230/240 VAC | |
AC Voltage Regulation (Batt. Mode) | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | |
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |
Transfer Time | AC Mode to Battery Mode | Zero | Zero | Zero | Zero | Zero | Zero |
Transfer Time | ECO to Battery mode | 8 ms (Typical), 10 ms(max) | 8 ms (Typical), 10 ms(max) | 8 ms (Typical), 10 ms(max) | 8 ms (Typical), 10 ms(max) | 8 ms (Typical), 10 ms(max) | 8 ms (Typical), 10 ms(max) |
Transfer Time | Inverter to Bypass | 4 ms (Typical) | 4 ms (Typical) | 4 ms (Typical) | 4 ms (Typical) | 4 ms (Typical) | 4 ms (Typical) |
Waveform (Batt. Mode) | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | |
Current Crest Ratio | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 | |
Harmonic Distortion | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) | |
Frequency Range (Synchronized Range) | 47~53 Hz or 57~63 Hz | 47~53 Hz or 57~63 Hz | 47~53 Hz or 57~63 Hz | 47~53 Hz or 57~63 Hz | 47~53 Hz or 57~63 Hz | 47~53 Hz or 57~63 Hz | |
EFFICIENCY | |||||||
Battery Mode | 96% | 96% | 97% | 97% | 97% | 97% | |
ECO Mode | 92% | 92% | 92% | 93% | 93% | 94% | |
AC Mode | 86% | 89% | 89% | 88% | 89% | 91% | |
BATTERY | |||||||
Standard Model | Battery Type | 12 V / 9 Ah | 12 V / 7 Ah | 12 V / 9 Ah | 12 V / 9 Ah | 12 V / 7 Ah | 12 V / 9 Ah |
Standard Model | Charging Current (max.) | 1.5 A | 1.5 A | 1.5 A | 1.5 A | 1.5 A | 1.5 A |
Standard Model | Charging Voltage | 27.4VDC ± 1% | 41.0 VDC ± 1% | 41.0 VDC ± 1% | 54.8VDC ± 1% | 82.2 VDC ± 1% | 82.2 VDC ± 1% |
Standard Model | Numbers | 2 | 3 | 3 | 4 | 6 | 6 |
Standard Model | Typical Recharge Time | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity |
INDICATORS | |||||||
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | |
ENVIRONMENT | |||||||
Operating Humidity | 20~95% RH @ 0- 50°C (non-condensing) | 20~95% RH @ 0- 50°C (non-condensing) | 20~95% RH @ 0- 50°C (non-condensing) | 20~95% RH @ 0- 50°C (non-condensing) | 20~95% RH @ 0- 50°C (non-condensing) | 20~95% RH @ 0- 50°C (non-condensing) | |
Noise Level | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | |
PHYSICAL | |||||||
Standard Model | Dimension, D X W X H (mm) | 282 X 145 X 220 | 397 X 145 X 220 | 397 X 145 X 220 | 397 X 145 X 220 | 421 X 190 X 318 | 421 X 190 X 318 |
Standard Model | Net Weight (kgs) | 9.8 | 11.4 | 13.8 | 17 | 22.5 | 26.2 |
MANAGEMENT | |||||||
Optional external Slot (for SNMP, Dry contact, …) | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | |
Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | |
STANDARD | |||||||
EMC/Safety | CE (EMC: EN62040-2 C2) | CE (EMC: EN62040-2 C2) | CE (EMC: EN62040-2 C2) | CE (EMC: EN62040-2 C2) | CE (EMC: EN62040-2 C2) | CE (EMC: EN62040-2 C2) |
General
CAPACITY
Galleon III 1K-2B | 1000 VA / 1000 W |
---|---|
Galleon III 1K-3B | 1000 VA / 1000 W |
Galleon III 1.5K | 1500 VA / 1500 W |
Galleon III 2K-4B | 2000 VA / 2000 W |
Galleon III 2K-6B | 2000 VA / 2000 W |
Galleon III 3K | 3000 VA / 3000 W |
PHASE
Galleon III 1K-2B | Single phase with ground |
---|---|
Galleon III 1K-3B | Single phase with ground |
Galleon III 1.5K | Single phase with ground |
Galleon III 2K-4B | Single phase with ground |
Galleon III 2K-6B | Single phase with ground |
Galleon III 3K | Single phase with ground |
INPUT
Voltage Range
Galleon III 1K-2B | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) |
---|---|
Galleon III 1K-3B | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) |
Galleon III 1.5K | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) |
Galleon III 2K-4B | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) |
Galleon III 2K-6B | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) |
Galleon III 3K | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) |
Nominal Voltage
Galleon III 1K-2B | 200*/208*/220/230/240 VAC |
---|---|
Galleon III 1K-3B | 200*/208*/220/230/240 VAC |
Galleon III 1.5K | 200*/208*/220/230/240 VAC |
Galleon III 2K-4B | 200*/208*/220/230/240 VAC |
Galleon III 2K-6B | 200*/208*/220/230/240 VAC |
Galleon III 3K | 200*/208*/220/230/240 VAC |
Frequency Range
Galleon III 1K-2B | 40 Hz~70 Hz |
---|---|
Galleon III 1K-3B | 40 Hz~70 Hz |
Galleon III 1.5K | 40 Hz~70 Hz |
Galleon III 2K-4B | 40 Hz~70 Hz |
Galleon III 2K-6B | 40 Hz~70 Hz |
Galleon III 3K | 40 Hz~70 Hz |
Power Factor
Galleon III 1K-2B | ≧ 0.99 @ Nominal Voltage (100% load) |
---|---|
Galleon III 1K-3B | ≧ 0.99 @ Nominal Voltage (100% load) |
Galleon III 1.5K | ≧ 0.99 @ Nominal Voltage (100% load) |
Galleon III 2K-4B | ≧ 0.99 @ Nominal Voltage (100% load) |
Galleon III 2K-6B | ≧ 0.99 @ Nominal Voltage (100% load) |
Galleon III 3K | ≧ 0.99 @ Nominal Voltage (100% load) |
Harmonic Distortion (THDi)
Galleon III 1K-2B | ≦ 5% @ nominal voltage (100% load) |
---|---|
Galleon III 1K-3B | ≦ 5% @ nominal voltage (100% load) |
Galleon III 1.5K | ≦ 5% @ nominal voltage (100% load) |
Galleon III 2K-4B | ≦ 5% @ nominal voltage (100% load) |
Galleon III 2K-6B | ≦ 5% @ nominal voltage (100% load) |
Galleon III 3K | ≦ 5% @ nominal voltage (100% load) |
OUTPUT
Output Voltage
Galleon III 1K-2B | 200*/208*/220/230/240 VAC |
---|---|
Galleon III 1K-3B | 200*/208*/220/230/240 VAC |
Galleon III 1.5K | 200*/208*/220/230/240 VAC |
Galleon III 2K-4B | 200*/208*/220/230/240 VAC |
Galleon III 2K-6B | 200*/208*/220/230/240 VAC |
Galleon III 3K | 200*/208*/220/230/240 VAC |
AC Voltage Regulation (Batt. Mode)
Galleon III 1K-2B | ± 1% |
---|---|
Galleon III 1K-3B | ± 1% |
Galleon III 1.5K | ± 1% |
Galleon III 2K-4B | ± 1% |
Galleon III 2K-6B | ± 1% |
Galleon III 3K | ± 1% |
Frequency Range (Batt. Mode)
Galleon III 1K-2B | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
---|---|
Galleon III 1K-3B | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon III 1.5K | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon III 2K-4B | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon III 2K-6B | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Galleon III 3K | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Transfer Time AC Mode to Battery Mode
Galleon III 1K-2B | Zero |
---|---|
Galleon III 1K-3B | Zero |
Galleon III 1.5K | Zero |
Galleon III 2K-4B | Zero |
Galleon III 2K-6B | Zero |
Galleon III 3K | Zero |
Transfer Time ECO to Battery mode
Galleon III 1K-2B | 8 ms (Typical), 10 ms(max) |
---|---|
Galleon III 1K-3B | 8 ms (Typical), 10 ms(max) |
Galleon III 1.5K | 8 ms (Typical), 10 ms(max) |
Galleon III 2K-4B | 8 ms (Typical), 10 ms(max) |
Galleon III 2K-6B | 8 ms (Typical), 10 ms(max) |
Galleon III 3K | 8 ms (Typical), 10 ms(max) |
Transfer Time Inverter to Bypass
Galleon III 1K-2B | 4 ms (Typical) |
---|---|
Galleon III 1K-3B | 4 ms (Typical) |
Galleon III 1.5K | 4 ms (Typical) |
Galleon III 2K-4B | 4 ms (Typical) |
Galleon III 2K-6B | 4 ms (Typical) |
Galleon III 3K | 4 ms (Typical) |
Waveform (Batt. Mode)
Galleon III 1K-2B | Pure Sine Wave |
---|---|
Galleon III 1K-3B | Pure Sine Wave |
Galleon III 1.5K | Pure Sine Wave |
Galleon III 2K-4B | Pure Sine Wave |
Galleon III 2K-6B | Pure Sine Wave |
Galleon III 3K | Pure Sine Wave |
Current Crest Ratio
Galleon III 1K-2B | 3:1 |
---|---|
Galleon III 1K-3B | 3:1 |
Galleon III 1.5K | 3:1 |
Galleon III 2K-4B | 3:1 |
Galleon III 2K-6B | 3:1 |
Galleon III 3K | 3:1 |
Harmonic Distortion
Galleon III 1K-2B | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) |
---|---|
Galleon III 1K-3B | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) |
Galleon III 1.5K | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) |
Galleon III 2K-4B | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) |
Galleon III 2K-6B | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) |
Galleon III 3K | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) |
Frequency Range (Synchronized Range)
Galleon III 1K-2B | 47~53 Hz or 57~63 Hz |
---|---|
Galleon III 1K-3B | 47~53 Hz or 57~63 Hz |
Galleon III 1.5K | 47~53 Hz or 57~63 Hz |
Galleon III 2K-4B | 47~53 Hz or 57~63 Hz |
Galleon III 2K-6B | 47~53 Hz or 57~63 Hz |
Galleon III 3K | 47~53 Hz or 57~63 Hz |
EFFICIENCY
Battery Mode
Galleon III 1K-2B | 96% |
---|---|
Galleon III 1K-3B | 96% |
Galleon III 1.5K | 97% |
Galleon III 2K-4B | 97% |
Galleon III 2K-6B | 97% |
Galleon III 3K | 97% |
ECO Mode
Galleon III 1K-2B | 92% |
---|---|
Galleon III 1K-3B | 92% |
Galleon III 1.5K | 92% |
Galleon III 2K-4B | 93% |
Galleon III 2K-6B | 93% |
Galleon III 3K | 94% |
AC Mode
Galleon III 1K-2B | 86% |
---|---|
Galleon III 1K-3B | 89% |
Galleon III 1.5K | 89% |
Galleon III 2K-4B | 88% |
Galleon III 2K-6B | 89% |
Galleon III 3K | 91% |
BATTERY
Standard Model Battery Type
Galleon III 1K-2B | 12 V / 9 Ah |
---|---|
Galleon III 1K-3B | 12 V / 7 Ah |
Galleon III 1.5K | 12 V / 9 Ah |
Galleon III 2K-4B | 12 V / 9 Ah |
Galleon III 2K-6B | 12 V / 7 Ah |
Galleon III 3K | 12 V / 9 Ah |
Standard Model Charging Current (max.)
Galleon III 1K-2B | 1.5 A |
---|---|
Galleon III 1K-3B | 1.5 A |
Galleon III 1.5K | 1.5 A |
Galleon III 2K-4B | 1.5 A |
Galleon III 2K-6B | 1.5 A |
Galleon III 3K | 1.5 A |
Standard Model Charging Voltage
Galleon III 1K-2B | 27.4VDC ± 1% |
---|---|
Galleon III 1K-3B | 41.0 VDC ± 1% |
Galleon III 1.5K | 41.0 VDC ± 1% |
Galleon III 2K-4B | 54.8VDC ± 1% |
Galleon III 2K-6B | 82.2 VDC ± 1% |
Galleon III 3K | 82.2 VDC ± 1% |
Standard Model Numbers
Galleon III 1K-2B | 2 |
---|---|
Galleon III 1K-3B | 3 |
Galleon III 1.5K | 3 |
Galleon III 2K-4B | 4 |
Galleon III 2K-6B | 6 |
Galleon III 3K | 6 |
Standard Model Typical Recharge Time
Galleon III 1K-2B | 4 hours recover to 90% capacity |
---|---|
Galleon III 1K-3B | 4 hours recover to 90% capacity |
Galleon III 1.5K | 4 hours recover to 90% capacity |
Galleon III 2K-4B | 4 hours recover to 90% capacity |
Galleon III 2K-6B | 4 hours recover to 90% capacity |
Galleon III 3K | 4 hours recover to 90% capacity |
INDICATORS
LCD Panel
Galleon III 1K-2B | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
---|---|
Galleon III 1K-3B | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon III 1.5K | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon III 2K-4B | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon III 2K-6B | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Galleon III 3K | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
ENVIRONMENT
Operating Humidity
Galleon III 1K-2B | 20~95% RH @ 0- 50°C (non-condensing) |
---|---|
Galleon III 1K-3B | 20~95% RH @ 0- 50°C (non-condensing) |
Galleon III 1.5K | 20~95% RH @ 0- 50°C (non-condensing) |
Galleon III 2K-4B | 20~95% RH @ 0- 50°C (non-condensing) |
Galleon III 2K-6B | 20~95% RH @ 0- 50°C (non-condensing) |
Galleon III 3K | 20~95% RH @ 0- 50°C (non-condensing) |
Noise Level
Galleon III 1K-2B | Less than 50dB @ 1 Meter |
---|---|
Galleon III 1K-3B | Less than 50dB @ 1 Meter |
Galleon III 1.5K | Less than 50dB @ 1 Meter |
Galleon III 2K-4B | Less than 50dB @ 1 Meter |
Galleon III 2K-6B | Less than 50dB @ 1 Meter |
Galleon III 3K | Less than 50dB @ 1 Meter |
PHYSICAL
Standard Model Dimension, D X W X H (mm)
Galleon III 1K-2B | 282 X 145 X 220 |
---|---|
Galleon III 1K-3B | 397 X 145 X 220 |
Galleon III 1.5K | 397 X 145 X 220 |
Galleon III 2K-4B | 397 X 145 X 220 |
Galleon III 2K-6B | 421 X 190 X 318 |
Galleon III 3K | 421 X 190 X 318 |
Standard Model Net Weight (kgs)
Galleon III 1K-2B | 9.8 |
---|---|
Galleon III 1K-3B | 11.4 |
Galleon III 1.5K | 13.8 |
Galleon III 2K-4B | 17 |
Galleon III 2K-6B | 22.5 |
Galleon III 3K | 26.2 |
MANAGEMENT
Optional external Slot (for SNMP, Dry contact, …)
Galleon III 1K-2B | Power management from SNMP manager and web browser |
---|---|
Galleon III 1K-3B | Power management from SNMP manager and web browser |
Galleon III 1.5K | Power management from SNMP manager and web browser |
Galleon III 2K-4B | Power management from SNMP manager and web browser |
Galleon III 2K-6B | Power management from SNMP manager and web browser |
Galleon III 3K | Power management from SNMP manager and web browser |
Smart RS-232 / USB
Galleon III 1K-2B | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
---|---|
Galleon III 1K-3B | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon III 1.5K | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon III 2K-4B | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon III 2K-6B | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon III 3K | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
STANDARD
EMC/Safety
Galleon III 1K-2B | CE (EMC: EN62040-2 C2) |
---|---|
Galleon III 1K-3B | CE (EMC: EN62040-2 C2) |
Galleon III 1.5K | CE (EMC: EN62040-2 C2) |
Galleon III 2K-4B | CE (EMC: EN62040-2 C2) |
Galleon III 2K-6B | CE (EMC: EN62040-2 C2) |
Galleon III 3K | CE (EMC: EN62040-2 C2) |
![]() |
Brochure | Galleon_III-1K-3K_Rack(PF1) |
![]() |
Brochure | Galleon_III-1K-3K_Tower |
![]() |
Manual | Galleon III-Tower-Rack-1-3K manual |