Galleon X9 II 1K-3KVA Rack/Tower
User-friendly and easy-shift LCD display
Ideal for medium-density power protection demand, Galleon X9 series provides Rack/Tower form factor to fit diverse environment. Despite its compact footprint, this UPS incorporates internal battery packs which can be accessed via the front panel for maintenance checks and replacement without removing the UPS from its rack mounting. The LCD display panel can be easily shifted by pressing buttons to suit the installation format, vertically stand or flatly rack mount. Besides, IT personnel can manage equipment well from learning remaining backup time information via LCD display.
Main Features
- True double-conversion online UPS
- Output power factor 0.9
- User-friendly and easy-shift LCD display
- Rack/Tower design
- Programmable power management outlets
- 50/60 Hz frequency converter mode
- ECO and advanced ECO mode for energy saving
- Emergency Power Off Function (EPO)
- Hot-swappable battery design for 1-3K models only
- DSP technology applied for 6K and up models
- Active input power factor correction 0.99 for 6K and up models
- N+X parallel redundancy available for 6K and up models
MODEL | Galleon X9 II 1K | Galleon X9 II 1.5K | Galleon X9 II 2K | Galleon X9 II 3K | |
CAPACITY | 1000 VA / 900 W | 1500 VA / 1350 W | 2000 VA / 1800 W | 3000 VA / 2700 W | |
PHASE | Single phase with ground | Single phase with ground | Single phase with ground | Single phase with ground | |
INPUT | |||||
Voltage Range | 55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load | 55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load | 55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load | 55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load | |
Nominal Voltage | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC | |
Frequency Range | 40Hz~70Hz | 40Hz~70Hz | 40Hz~70Hz | 40Hz~70Hz | |
Power Factor | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ Nominal Voltage (100% load) | |
Harmonic Distortion (THDi) | ≦ 5% @ nominal input voltage | ≦ 5% @ nominal input voltage | ≦ 5% @ nominal input voltage | ≦ 5% @ nominal input voltage | |
OUTPUT | |||||
Output Voltage | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC | |
AC Voltage Regulation (Batt. Mode) | ± 1% | ± 1% | ± 1% | ± 1% | |
Frequency Range (Batt. Mode) | 50 Hz or 60 Hz ± 0.1 Hz | 50 Hz or 60 Hz ± 0.1 Hz | 50 Hz or 60 Hz ± 0.1 Hz | 50 Hz or 60 Hz ± 0.1 Hz | |
Transfer Time | Zero | Zero | Zero | Zero | |
Waveform (Batt. Mode) | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | |
Current Crest Ratio | 3:1 (max.) | 3:1 (max.) | 3:1 (max.) | 3:1 (max.) | |
Harmonic Distortion | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear load) | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear load) | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear load) | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear load) | |
Frequency Range (Synchronized Range) | 57~63 Hz or 47~53 Hz or | 57~63 Hz or 47~53 Hz or | 57~63 Hz or 47~53 Hz or | 57~63 Hz or 47~53 Hz or | |
EFFICIENCY | |||||
Battery Mode | 88%, 89% | 89% | 88%, 89% | 90% | |
ECO Mode | 97% | 97% | 97% | 97% | |
AC Mode | 90% | 90% | 91% | 91% | |
BATTERY | |||||
Long-run Model | Battery Type | Depending on the capacity of external batteries | Depending on the capacity of external batteries | Depending on the capacity of external batteries | Depending on the capacity of external batteries |
Long-run Model | Charging Current (max.) | 1A / 2A / 4A / 8A | 1A / 2A / 4A / 8A | 1A / 2A / 4A / 8A | 1A / 2A / 4A / 8A |
Long-run Model | Charging Voltage | 27.4 VDC ± 1%, 41.1 VDC ± 1% | 41.1 VDC ± 1% | 54.8 VDC ± 1%, 82.1 VDC ± 1% | 82.1 VDC ± 1% |
Long-run Model | Numbers | 2,3 | 3 | 4, 6 | 6 |
Standard Model | Battery Type | 12 V / 9 AH, 12 V / 7 AH | 12 V / 9 AH | 12 V / 9 AH, 12 V / 7 AH | 12 V / 9 AH |
Standard Model | Charging Current (max.) | 1.5 A | 1.5 A | 1.5 A | 1.5 A |
Standard Model | Charging Voltage | 27.4 VDC ± 1%, 41.1 VDC ± 1% | 41.1 VDC ± 1% | 54.8 VDC ± 1%, 82.1 VDC ± 1% | 82.1 VDC ± 1% |
Standard Model | Numbers | 2, 3 | 3 | 4, 6 | 6 |
Standard Model | Typical Recharge Time | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity |
INDICATORS | |||||
LCD Display | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators | |
ALARM | |||||
Battery Mode | Sounding every 5 seconds | Sounding every 5 seconds | Sounding every 5 seconds | Sounding every 5 seconds | |
Low Battery | Sounding every 2 seconds | Sounding every 2 seconds | Sounding every 2 seconds | Sounding every 2 seconds | |
Overload | Sounding every second | Sounding every second | Sounding every second | Sounding every second | |
Fault | Continuously sounding | Continuously sounding | Continuously sounding | Continuously sounding | |
ENVIRONMENT | |||||
Operating Humidity | 20~90% RH @ 0- 40°C (non-condensing) | 20~90% RH @ 0- 40°C (non-condensing) | 20~90% RH @ 0- 40°C (non-condensing) | 20~90% RH @ 0- 40°C (non-condensing) | |
Noise Level | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | |
PHYSICAL | |||||
Standard Model | Dimension, D X W X H (mm) | 410 x 438 x 88 [2U] | 410 x 438 x 88 [2U] | 510 x 438 x 88 [2U], 630 x 438 x 88 [2U] | 630 x 438 x 88 [2U] |
Standard Model | Net Weight (kgs) | 11.6, 14.2 | 14.5 | 19.5, 26.5 | 27.4, 10.5 |
Long-run Model | Dimension, D X W X H (mm) | 410 x 438 x 88 [2U] | 410 x 438 x 88 [2U] | 410 x 438 x 88 [2U] | 510 x 438 x 88 [2U] |
Long-run Model | Net Weight (kgs) | 6.4 | 6.5 | 6.5 | 10.5 |
MANAGEMENT | |||||
Optional SNMP | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | Power management from SNMP manager and web browser | |
Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
General
CAPACITY
Galleon X9 II 1K | 1000 VA / 900 W |
---|---|
Galleon X9 II 1.5K | 1500 VA / 1350 W |
Galleon X9 II 2K | 2000 VA / 1800 W |
Galleon X9 II 3K | 3000 VA / 2700 W |
PHASE
Galleon X9 II 1K | Single phase with ground |
---|---|
Galleon X9 II 1.5K | Single phase with ground |
Galleon X9 II 2K | Single phase with ground |
Galleon X9 II 3K | Single phase with ground |
INPUT
Voltage Range
Galleon X9 II 1K | 55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load |
---|---|
Galleon X9 II 1.5K | 55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load |
Galleon X9 II 2K | 55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load |
Galleon X9 II 3K | 55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load |
Nominal Voltage
Galleon X9 II 1K | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC |
---|---|
Galleon X9 II 1.5K | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC |
Galleon X9 II 2K | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC |
Galleon X9 II 3K | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC |
Frequency Range
Galleon X9 II 1K | 40Hz~70Hz |
---|---|
Galleon X9 II 1.5K | 40Hz~70Hz |
Galleon X9 II 2K | 40Hz~70Hz |
Galleon X9 II 3K | 40Hz~70Hz |
Power Factor
Galleon X9 II 1K | ≧ 0.99 @ Nominal Voltage (100% load) |
---|---|
Galleon X9 II 1.5K | ≧ 0.99 @ Nominal Voltage (100% load) |
Galleon X9 II 2K | ≧ 0.99 @ Nominal Voltage (100% load) |
Galleon X9 II 3K | ≧ 0.99 @ Nominal Voltage (100% load) |
Harmonic Distortion (THDi)
Galleon X9 II 1K | ≦ 5% @ nominal input voltage |
---|---|
Galleon X9 II 1.5K | ≦ 5% @ nominal input voltage |
Galleon X9 II 2K | ≦ 5% @ nominal input voltage |
Galleon X9 II 3K | ≦ 5% @ nominal input voltage |
OUTPUT
Output Voltage
Galleon X9 II 1K | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC |
---|---|
Galleon X9 II 1.5K | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC |
Galleon X9 II 2K | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC |
Galleon X9 II 3K | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC |
AC Voltage Regulation (Batt. Mode)
Galleon X9 II 1K | ± 1% |
---|---|
Galleon X9 II 1.5K | ± 1% |
Galleon X9 II 2K | ± 1% |
Galleon X9 II 3K | ± 1% |
Frequency Range (Batt. Mode)
Galleon X9 II 1K | 50 Hz or 60 Hz ± 0.1 Hz |
---|---|
Galleon X9 II 1.5K | 50 Hz or 60 Hz ± 0.1 Hz |
Galleon X9 II 2K | 50 Hz or 60 Hz ± 0.1 Hz |
Galleon X9 II 3K | 50 Hz or 60 Hz ± 0.1 Hz |
Transfer Time
Galleon X9 II 1K | Zero |
---|---|
Galleon X9 II 1.5K | Zero |
Galleon X9 II 2K | Zero |
Galleon X9 II 3K | Zero |
Waveform (Batt. Mode)
Galleon X9 II 1K | Pure Sine Wave |
---|---|
Galleon X9 II 1.5K | Pure Sine Wave |
Galleon X9 II 2K | Pure Sine Wave |
Galleon X9 II 3K | Pure Sine Wave |
Current Crest Ratio
Galleon X9 II 1K | 3:1 (max.) |
---|---|
Galleon X9 II 1.5K | 3:1 (max.) |
Galleon X9 II 2K | 3:1 (max.) |
Galleon X9 II 3K | 3:1 (max.) |
Harmonic Distortion
Galleon X9 II 1K | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear load) |
---|---|
Galleon X9 II 1.5K | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear load) |
Galleon X9 II 2K | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear load) |
Galleon X9 II 3K | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear load) |
Frequency Range (Synchronized Range)
Galleon X9 II 1K | 57~63 Hz or 47~53 Hz or |
---|---|
Galleon X9 II 1.5K | 57~63 Hz or 47~53 Hz or |
Galleon X9 II 2K | 57~63 Hz or 47~53 Hz or |
Galleon X9 II 3K | 57~63 Hz or 47~53 Hz or |
EFFICIENCY
Battery Mode
Galleon X9 II 1K | 88%, 89% |
---|---|
Galleon X9 II 1.5K | 89% |
Galleon X9 II 2K | 88%, 89% |
Galleon X9 II 3K | 90% |
ECO Mode
Galleon X9 II 1K | 97% |
---|---|
Galleon X9 II 1.5K | 97% |
Galleon X9 II 2K | 97% |
Galleon X9 II 3K | 97% |
AC Mode
Galleon X9 II 1K | 90% |
---|---|
Galleon X9 II 1.5K | 90% |
Galleon X9 II 2K | 91% |
Galleon X9 II 3K | 91% |
BATTERY
Long-run Model Battery Type
Galleon X9 II 1K | Depending on the capacity of external batteries |
---|---|
Galleon X9 II 1.5K | Depending on the capacity of external batteries |
Galleon X9 II 2K | Depending on the capacity of external batteries |
Galleon X9 II 3K | Depending on the capacity of external batteries |
Long-run Model Charging Current (max.)
Galleon X9 II 1K | 1A / 2A / 4A / 8A |
---|---|
Galleon X9 II 1.5K | 1A / 2A / 4A / 8A |
Galleon X9 II 2K | 1A / 2A / 4A / 8A |
Galleon X9 II 3K | 1A / 2A / 4A / 8A |
Long-run Model Charging Voltage
Galleon X9 II 1K | 27.4 VDC ± 1%, 41.1 VDC ± 1% |
---|---|
Galleon X9 II 1.5K | 41.1 VDC ± 1% |
Galleon X9 II 2K | 54.8 VDC ± 1%, 82.1 VDC ± 1% |
Galleon X9 II 3K | 82.1 VDC ± 1% |
Long-run Model Numbers
Galleon X9 II 1K | 2,3 |
---|---|
Galleon X9 II 1.5K | 3 |
Galleon X9 II 2K | 4, 6 |
Galleon X9 II 3K | 6 |
Standard Model Battery Type
Galleon X9 II 1K | 12 V / 9 AH, 12 V / 7 AH |
---|---|
Galleon X9 II 1.5K | 12 V / 9 AH |
Galleon X9 II 2K | 12 V / 9 AH, 12 V / 7 AH |
Galleon X9 II 3K | 12 V / 9 AH |
Standard Model Charging Current (max.)
Galleon X9 II 1K | 1.5 A |
---|---|
Galleon X9 II 1.5K | 1.5 A |
Galleon X9 II 2K | 1.5 A |
Galleon X9 II 3K | 1.5 A |
Standard Model Charging Voltage
Galleon X9 II 1K | 27.4 VDC ± 1%, 41.1 VDC ± 1% |
---|---|
Galleon X9 II 1.5K | 41.1 VDC ± 1% |
Galleon X9 II 2K | 54.8 VDC ± 1%, 82.1 VDC ± 1% |
Galleon X9 II 3K | 82.1 VDC ± 1% |
Standard Model Numbers
Galleon X9 II 1K | 2, 3 |
---|---|
Galleon X9 II 1.5K | 3 |
Galleon X9 II 2K | 4, 6 |
Galleon X9 II 3K | 6 |
Standard Model Typical Recharge Time
Galleon X9 II 1K | 4 hours recover to 90% capacity |
---|---|
Galleon X9 II 1.5K | 4 hours recover to 90% capacity |
Galleon X9 II 2K | 4 hours recover to 90% capacity |
Galleon X9 II 3K | 4 hours recover to 90% capacity |
INDICATORS
LCD Display
Galleon X9 II 1K | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
---|---|
Galleon X9 II 1.5K | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
Galleon X9 II 2K | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
Galleon X9 II 3K | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
ALARM
Battery Mode
Galleon X9 II 1K | Sounding every 5 seconds |
---|---|
Galleon X9 II 1.5K | Sounding every 5 seconds |
Galleon X9 II 2K | Sounding every 5 seconds |
Galleon X9 II 3K | Sounding every 5 seconds |
Low Battery
Galleon X9 II 1K | Sounding every 2 seconds |
---|---|
Galleon X9 II 1.5K | Sounding every 2 seconds |
Galleon X9 II 2K | Sounding every 2 seconds |
Galleon X9 II 3K | Sounding every 2 seconds |
Overload
Galleon X9 II 1K | Sounding every second |
---|---|
Galleon X9 II 1.5K | Sounding every second |
Galleon X9 II 2K | Sounding every second |
Galleon X9 II 3K | Sounding every second |
Fault
Galleon X9 II 1K | Continuously sounding |
---|---|
Galleon X9 II 1.5K | Continuously sounding |
Galleon X9 II 2K | Continuously sounding |
Galleon X9 II 3K | Continuously sounding |
ENVIRONMENT
Operating Humidity
Galleon X9 II 1K | 20~90% RH @ 0- 40°C (non-condensing) |
---|---|
Galleon X9 II 1.5K | 20~90% RH @ 0- 40°C (non-condensing) |
Galleon X9 II 2K | 20~90% RH @ 0- 40°C (non-condensing) |
Galleon X9 II 3K | 20~90% RH @ 0- 40°C (non-condensing) |
Noise Level
Galleon X9 II 1K | Less than 50dB @ 1 Meter |
---|---|
Galleon X9 II 1.5K | Less than 50dB @ 1 Meter |
Galleon X9 II 2K | Less than 50dB @ 1 Meter |
Galleon X9 II 3K | Less than 50dB @ 1 Meter |
PHYSICAL
Standard Model Dimension, D X W X H (mm)
Galleon X9 II 1K | 410 x 438 x 88 [2U] |
---|---|
Galleon X9 II 1.5K | 410 x 438 x 88 [2U] |
Galleon X9 II 2K | 510 x 438 x 88 [2U], 630 x 438 x 88 [2U] |
Galleon X9 II 3K | 630 x 438 x 88 [2U] |
Standard Model Net Weight (kgs)
Galleon X9 II 1K | 11.6, 14.2 |
---|---|
Galleon X9 II 1.5K | 14.5 |
Galleon X9 II 2K | 19.5, 26.5 |
Galleon X9 II 3K | 27.4, 10.5 |
Long-run Model Dimension, D X W X H (mm)
Galleon X9 II 1K | 410 x 438 x 88 [2U] |
---|---|
Galleon X9 II 1.5K | 410 x 438 x 88 [2U] |
Galleon X9 II 2K | 410 x 438 x 88 [2U] |
Galleon X9 II 3K | 510 x 438 x 88 [2U] |
Long-run Model Net Weight (kgs)
Galleon X9 II 1K | 6.4 |
---|---|
Galleon X9 II 1.5K | 6.5 |
Galleon X9 II 2K | 6.5 |
Galleon X9 II 3K | 10.5 |
MANAGEMENT
Optional SNMP
Galleon X9 II 1K | Power management from SNMP manager and web browser |
---|---|
Galleon X9 II 1.5K | Power management from SNMP manager and web browser |
Galleon X9 II 2K | Power management from SNMP manager and web browser |
Galleon X9 II 3K | Power management from SNMP manager and web browser |
Smart RS-232/USB
Galleon X9 II 1K | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
---|---|
Galleon X9 II 1.5K | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon X9 II 2K | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Galleon X9 II 3K | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |
Brochure | Galleon X9 II 1K-3KVA Rack/Tower _Brochure | |
Manual | Galleon X9 II 1K-3KVA Rack/Tower_Manual |
Single phase - Online UPS Galleon X9 II 1K-3KVA Rack/Tower User-friendly and easy-shift LCD display
We have received your membership application and will reply as soon as within 24 hours, before that, please browse our website, thank you.