Galleon X9 II 1K-3KVA Rack/Tower
User-friendly and easy-shift LCD display
Ideal for medium-density power protection demand, Galleon X9 series provides Rack/Tower form factor to fit diverse environment. Despite its compact footprint, this UPS incorporates internal battery packs which can be accessed via the front panel for maintenance checks and replacement without removing the UPS from its rack mounting. The LCD display panel can be easily shifted by pressing buttons to suit the installation format, vertically stand or flatly rack mount. Besides, IT personnel can manage equipment well from learning remaining backup time information via LCD display.
Main Features
  • True double-conversion online UPS
  • Output power factor 0.9
  • User-friendly and easy-shift LCD display
  • Rack/Tower design
  • Programmable power management outlets
  • 50/60 Hz frequency converter mode
  • ECO and advanced ECO mode for energy saving
  • Emergency Power Off Function (EPO)
  • Hot-swappable battery design for 1-3K models only
  • DSP technology applied for 6K and up models
  • Active input power factor correction 0.99 for 6K and up models
  • N+X parallel redundancy available for 6K and up models
General
CAPACITY
Galleon X9 II 1K1000 VA / 900 W
Galleon X9 II 1.5K1500 VA / 1350 W
Galleon X9 II 2K2000 VA / 1800 W
Galleon X9 II 3K3000 VA / 2700 W
PHASE
Galleon X9 II 1KSingle phase with ground
Galleon X9 II 1.5KSingle phase with ground
Galleon X9 II 2KSingle phase with ground
Galleon X9 II 3KSingle phase with ground
INPUT
Voltage Range
Galleon X9 II 1K55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load
Galleon X9 II 1.5K55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load
Galleon X9 II 2K55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load
Galleon X9 II 3K55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load
Nominal Voltage
Galleon X9 II 1K100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC
Galleon X9 II 1.5K100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC
Galleon X9 II 2K100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC
Galleon X9 II 3K100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC
Frequency Range
Galleon X9 II 1K40Hz~70Hz
Galleon X9 II 1.5K40Hz~70Hz
Galleon X9 II 2K40Hz~70Hz
Galleon X9 II 3K40Hz~70Hz
Power Factor
Galleon X9 II 1K≧ 0.99 @ Nominal Voltage (100% load)
Galleon X9 II 1.5K≧ 0.99 @ Nominal Voltage (100% load)
Galleon X9 II 2K≧ 0.99 @ Nominal Voltage (100% load)
Galleon X9 II 3K≧ 0.99 @ Nominal Voltage (100% load)
Harmonic Distortion (THDi)
Galleon X9 II 1K≦ 5% @ nominal input voltage
Galleon X9 II 1.5K≦ 5% @ nominal input voltage
Galleon X9 II 2K≦ 5% @ nominal input voltage
Galleon X9 II 3K≦ 5% @ nominal input voltage
OUTPUT
Output Voltage
Galleon X9 II 1K100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC
Galleon X9 II 1.5K100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC
Galleon X9 II 2K100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC
Galleon X9 II 3K100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode)
Galleon X9 II 1K± 1%
Galleon X9 II 1.5K± 1%
Galleon X9 II 2K± 1%
Galleon X9 II 3K± 1%
Frequency Range (Batt. Mode)
Galleon X9 II 1K50 Hz or 60 Hz ± 0.1 Hz
Galleon X9 II 1.5K50 Hz or 60 Hz ± 0.1 Hz
Galleon X9 II 2K50 Hz or 60 Hz ± 0.1 Hz
Galleon X9 II 3K50 Hz or 60 Hz ± 0.1 Hz
Transfer Time
Galleon X9 II 1KZero
Galleon X9 II 1.5KZero
Galleon X9 II 2KZero
Galleon X9 II 3KZero
Waveform (Batt. Mode)
Galleon X9 II 1KPure Sine Wave
Galleon X9 II 1.5KPure Sine Wave
Galleon X9 II 2KPure Sine Wave
Galleon X9 II 3KPure Sine Wave
Current Crest Ratio
Galleon X9 II 1K3:1 (max.)
Galleon X9 II 1.5K3:1 (max.)
Galleon X9 II 2K3:1 (max.)
Galleon X9 II 3K3:1 (max.)
Harmonic Distortion
Galleon X9 II 1K≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear load)
Galleon X9 II 1.5K≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear load)
Galleon X9 II 2K≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear load)
Galleon X9 II 3K≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear load)
Frequency Range (Synchronized Range)
Galleon X9 II 1K57~63 Hz or 47~53 Hz or
Galleon X9 II 1.5K57~63 Hz or 47~53 Hz or
Galleon X9 II 2K57~63 Hz or 47~53 Hz or
Galleon X9 II 3K57~63 Hz or 47~53 Hz or
EFFICIENCY
Battery Mode
Galleon X9 II 1K88%, 89%
Galleon X9 II 1.5K89%
Galleon X9 II 2K88%, 89%
Galleon X9 II 3K90%
ECO Mode
Galleon X9 II 1K97%
Galleon X9 II 1.5K97%
Galleon X9 II 2K97%
Galleon X9 II 3K97%
AC Mode
Galleon X9 II 1K90%
Galleon X9 II 1.5K90%
Galleon X9 II 2K91%
Galleon X9 II 3K91%
BATTERY
Long-run Model Battery Type
Galleon X9 II 1KDepending on the capacity of external batteries
Galleon X9 II 1.5KDepending on the capacity of external batteries
Galleon X9 II 2KDepending on the capacity of external batteries
Galleon X9 II 3KDepending on the capacity of external batteries
Long-run Model Charging Current (max.)
Galleon X9 II 1K1A / 2A / 4A / 8A
Galleon X9 II 1.5K1A / 2A / 4A / 8A
Galleon X9 II 2K1A / 2A / 4A / 8A
Galleon X9 II 3K1A / 2A / 4A / 8A
Long-run Model Charging Voltage
Galleon X9 II 1K27.4 VDC ± 1%, 41.1 VDC ± 1%
Galleon X9 II 1.5K41.1 VDC ± 1%
Galleon X9 II 2K54.8 VDC ± 1%, 82.1 VDC ± 1%
Galleon X9 II 3K82.1 VDC ± 1%
Long-run Model Numbers
Galleon X9 II 1K2,3
Galleon X9 II 1.5K3
Galleon X9 II 2K4, 6
Galleon X9 II 3K6
Standard Model Battery Type
Galleon X9 II 1K12 V / 9 AH, 12 V / 7 AH
Galleon X9 II 1.5K12 V / 9 AH
Galleon X9 II 2K12 V / 9 AH, 12 V / 7 AH
Galleon X9 II 3K12 V / 9 AH
Standard Model Charging Current (max.)
Galleon X9 II 1K1.5 A
Galleon X9 II 1.5K1.5 A
Galleon X9 II 2K1.5 A
Galleon X9 II 3K1.5 A
Standard Model Charging Voltage
Galleon X9 II 1K27.4 VDC ± 1%, 41.1 VDC ± 1%
Galleon X9 II 1.5K41.1 VDC ± 1%
Galleon X9 II 2K54.8 VDC ± 1%, 82.1 VDC ± 1%
Galleon X9 II 3K82.1 VDC ± 1%
Standard Model Numbers
Galleon X9 II 1K2, 3
Galleon X9 II 1.5K3
Galleon X9 II 2K4, 6
Galleon X9 II 3K6
Standard Model Typical Recharge Time
Galleon X9 II 1K4 hours recover to 90% capacity
Galleon X9 II 1.5K4 hours recover to 90% capacity
Galleon X9 II 2K4 hours recover to 90% capacity
Galleon X9 II 3K4 hours recover to 90% capacity
INDICATORS
LCD Display
Galleon X9 II 1KLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
Galleon X9 II 1.5KLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
Galleon X9 II 2KLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
Galleon X9 II 3KLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
Battery Mode
Galleon X9 II 1KSounding every 5 seconds
Galleon X9 II 1.5KSounding every 5 seconds
Galleon X9 II 2KSounding every 5 seconds
Galleon X9 II 3KSounding every 5 seconds
Low Battery
Galleon X9 II 1KSounding every 2 seconds
Galleon X9 II 1.5KSounding every 2 seconds
Galleon X9 II 2KSounding every 2 seconds
Galleon X9 II 3KSounding every 2 seconds
Overload
Galleon X9 II 1KSounding every second
Galleon X9 II 1.5KSounding every second
Galleon X9 II 2KSounding every second
Galleon X9 II 3KSounding every second
Fault
Galleon X9 II 1KContinuously sounding
Galleon X9 II 1.5KContinuously sounding
Galleon X9 II 2KContinuously sounding
Galleon X9 II 3KContinuously sounding
ENVIRONMENT
Operating Humidity
Galleon X9 II 1K20~90% RH @ 0- 40°C (non-condensing)
Galleon X9 II 1.5K20~90% RH @ 0- 40°C (non-condensing)
Galleon X9 II 2K20~90% RH @ 0- 40°C (non-condensing)
Galleon X9 II 3K20~90% RH @ 0- 40°C (non-condensing)
Noise Level
Galleon X9 II 1KLess than 50dB @ 1 Meter
Galleon X9 II 1.5KLess than 50dB @ 1 Meter
Galleon X9 II 2KLess than 50dB @ 1 Meter
Galleon X9 II 3KLess than 50dB @ 1 Meter
PHYSICAL
Standard Model Dimension, D X W X H (mm)
Galleon X9 II 1K410 x 438 x 88 [2U]
Galleon X9 II 1.5K410 x 438 x 88 [2U]
Galleon X9 II 2K510 x 438 x 88 [2U], 630 x 438 x 88 [2U]
Galleon X9 II 3K630 x 438 x 88 [2U]
Standard Model Net Weight (kgs)
Galleon X9 II 1K11.6, 14.2
Galleon X9 II 1.5K14.5
Galleon X9 II 2K19.5, 26.5
Galleon X9 II 3K27.4, 10.5
Long-run Model Dimension, D X W X H (mm)
Galleon X9 II 1K410 x 438 x 88 [2U]
Galleon X9 II 1.5K410 x 438 x 88 [2U]
Galleon X9 II 2K410 x 438 x 88 [2U]
Galleon X9 II 3K510 x 438 x 88 [2U]
Long-run Model Net Weight (kgs)
Galleon X9 II 1K6.4
Galleon X9 II 1.5K6.5
Galleon X9 II 2K6.5
Galleon X9 II 3K10.5
MANAGEMENT
Optional SNMP
Galleon X9 II 1KPower management from SNMP manager and web browser
Galleon X9 II 1.5KPower management from SNMP manager and web browser
Galleon X9 II 2KPower management from SNMP manager and web browser
Galleon X9 II 3KPower management from SNMP manager and web browser
Smart RS-232/USB
Galleon X9 II 1KSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon X9 II 1.5KSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon X9 II 2KSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Galleon X9 II 3KSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
Brochure Galleon X9 II 1K-3KVA Rack/Tower _Brochure
Manual Galleon X9 II 1K-3KVA Rack/Tower_Manual
Related Products