88
EPS
24/7 Backup for Commercial and Industrial Use
The highly efficient Emergency Power System (EPS) is designed for commercial, banking, and industrial uses, including ATMs, CCTV, elevators, and large cooling systems. Each 5KW module features a powerful 60A charger. The system can be expanded up to 30KW by combining six modules, allowing a total current of 360A per system and reducing charging time while providing over 24 hours of backup power. The EPS supports both single-phase and three-phase configurations to accommodate various requirements.
Main Features
- Pure sine wave inverter
- Integrated AC charger with up to 60A capacity
- Adjustable charging current to suit different applications
- Configurable settings through an LCD
- Compatible with both mains power and generator power
- Automatic restart when AC power is restored
- Protection against overload and short circuits
- Intelligent battery charger design for enhanced battery performance
- Selectable input voltage range for use with home appliances and personal computers
- Cold start capability
- Supports parallel operation with up to 9 units
- Optional MPPT or PWM solar charger available
| MODEL | EPS 5KW | |
| Rated Power | 5000 VA / 5000 W | |
| INPUT | ||
| Voltage | 220/230/240 VAC | |
| Voltage Range | 170-255 VAC | |
| Frequency Range | 50 Hz/60 Hz (Auto sensing) | |
| AC CHARGER | ||
| Charging modes | 3 steps for CC, CF and Floating | |
| Maximum AC Charge Current (Adjustable) | 2.5~60 A | |
| OUTPUT | ||
| AC Voltage Regulation (Batt. Mode) | 220/230/240 VAC ± 5% | |
| Surge Power for 5 seconds | 10000 VA | |
| Efficiency (Peak) | 93% | |
| Transfer Time | <10 ms | |
| Waveform | Pure Sine Wave | |
| BATTERY | ||
| Battery Voltage | 48 VDC | |
| Floating Charge Voltage | 53.6 VDC | |
| Overcharge Protection | 60 VDC | |
| CC/CV Charge Voltage | 56.4 VDC | |
| SOLAR CHARGER (option) | ||
| Maximum PV Array Open Circuit Voltage | 145 VDC | |
| Maximum PV Array Power | 4000W | |
| Maximum Solar Charge Current | 80 A | |
| MPPT Range @ Operating Voltage | 60 VDC~115 VDC | |
| PARALLEL | ||
| Maximum Parallel units | Up to 9 units | |
| Parallel Type | Single Phase or Three Phase | |
| Transfer Time in Parallel Mode | <40ms | |
| PHYSICAL | ||
| Dimension, D X W X H (mm) | 400 x 438 x 88 (2U) | |
| Net Weight (kgs) | 9.1 | |
| INTERFACE | ||
| Communication Port | Modbus RS-485 | |
| Dry Contacts | Deliver signal to external device such as generator | |
| OPERATING ENVIRONMENT | ||
| Operating Humidity | 5% to 95% Relative Humidity(Non-condensing) | |
| Operating Temperature | 0℃ to 40℃ | |
| Storage Temperature | -15℃ to 60℃ | |
General
Rated Power
| EPS 5KW | 5000 VA / 5000 W |
|---|
INPUT
Voltage
| EPS 5KW | 220/230/240 VAC |
|---|
Voltage Range
| EPS 5KW | 170-255 VAC |
|---|
Frequency Range
| EPS 5KW | 50 Hz/60 Hz (Auto sensing) |
|---|
AC CHARGER
Charging modes
| EPS 5KW | 3 steps for CC, CF and Floating |
|---|
Maximum AC Charge Current (Adjustable)
| EPS 5KW | 2.5~60 A |
|---|
OUTPUT
AC Voltage Regulation (Batt. Mode)
| EPS 5KW | 220/230/240 VAC ± 5% |
|---|
Surge Power for 5 seconds
| EPS 5KW | 10000 VA |
|---|
Efficiency (Peak)
| EPS 5KW | 93% |
|---|
Transfer Time
| EPS 5KW | <10 ms |
|---|
Waveform
| EPS 5KW | Pure Sine Wave |
|---|
BATTERY
Battery Voltage
| EPS 5KW | 48 VDC |
|---|
Floating Charge Voltage
| EPS 5KW | 53.6 VDC |
|---|
Overcharge Protection
| EPS 5KW | 60 VDC |
|---|
CC/CV Charge Voltage
| EPS 5KW | 56.4 VDC |
|---|
SOLAR CHARGER (option)
Maximum PV Array Open Circuit Voltage
| EPS 5KW | 145 VDC |
|---|
Maximum PV Array Power
| EPS 5KW | 4000W |
|---|
Maximum Solar Charge Current
| EPS 5KW | 80 A |
|---|
MPPT Range @ Operating Voltage
| EPS 5KW | 60 VDC~115 VDC |
|---|
PARALLEL
Maximum Parallel units
| EPS 5KW | Up to 9 units |
|---|
Parallel Type
| EPS 5KW | Single Phase or Three Phase |
|---|
Transfer Time in Parallel Mode
| EPS 5KW | <40ms |
|---|
PHYSICAL
Dimension, D X W X H (mm)
| EPS 5KW | 400 x 438 x 88 (2U) |
|---|
Net Weight (kgs)
| EPS 5KW | 9.1 |
|---|
INTERFACE
Communication Port
| EPS 5KW | Modbus RS-485 |
|---|
Dry Contacts
| EPS 5KW | Deliver signal to external device such as generator |
|---|
OPERATING ENVIRONMENT
Operating Humidity
| EPS 5KW | 5% to 95% Relative Humidity(Non-condensing) |
|---|
Operating Temperature
| EPS 5KW | 0℃ to 40℃ |
|---|
Storage Temperature
| EPS 5KW | -15℃ to 60℃ |
|---|